Ultralight Fabric Reflux Tube (UFRT) Thermal/Vacuum Test

Spacecraft thermal control systems are essential to provide the necessary environment for the crew and equipment to function adequately on space missions. The Ultralight Fabric Reflux Tube (UFRT) was developed by Pacific Northwest Laboratory (PNL) as a lightweight radiator concept to be used on planetary-type missions (e.g., Moon, Mars). The UFRT consists of a thin-walled tube (acting as the fluid boundary), overwrapped with a low-mass ceramic fabric (acting as the primary pressure boundary). The tubes are placed in an array in the vertical position with the evaporators at the lower end. Heat is added to the evaporators, which vaporizes the working fluid. The vapor travels to the condenser end above and cools as heat is radiated to the environment. The fluid condensed on the tube wall is then returned to the evaporator by gravity. The primary objectives for the fiscal year 1994 program included the design and fabrication of prototype UFRTs and thermal/vacuum chamber testing of these test articles. Six UFRTS, with improved titanium liners, were successfully manufactured and provided to the Johnson Space Center in July 1994. Five were tested in a thermal/vacuum chamber in September 1994. Data obtained to characterize the performance of the UFRTs under simulated lunar conditions demonstrated the design concept successfully. In addition, a trade study showed that an optimized/improved UFRT could achieve as much as a 25% mass savings in the heat rejection subsystem of future planetary-type thermal control systems.

Hurlbert, K. M.↗

Hypersonic Boundary-Layer Stability Experiments on a Flared-Cone Model at Angle of Attack in a Quiet Wind Tunnel

An experimental investigation of the effects of angle of attack on hypersonic boundary-layer stability on a flared-cone model was conducted in the low-disturbance Mach-6 Nozzle-Test Chamber Facility at NASA Langley Research Center. This unique facility provided a 'quiet' flow test environment which is well suited for stability experiments because the low levels of freestream 'noise' minimize artificial stimulation of flow-disturbance growth. Surface pressure and temperature measurements documented the adverse-pressure gradient and transition-onset location. Hot-wire anemometry diagnostics were applied to identify the instability mechanisms which lead to transition. In addition, the mean flow over the flared-cone geometry was modeled by laminar Navier-Stokes computations. Results show that the boundary layer becomes more stable on the windward ray and less stable on the leeward ray relative to the zero-degree angle-of-attack case. The second-mode instability dominates the transition process at a zero-degree angle of attack, however, on the windward ray at an angle of attack this mode was completely stabilized. The less-dominant first-mode instability was slightly destabilized on the windward ray. Non-linear mechanisms such as saturation and harmonic generation are identified from the flow-disturbance bispectra.

Doggett, Glen P.↗

Verification of International Space Station Component Leak Rates by Helium Accumulation Method

Discovery of leakage on several International Space Station U.S. Laboratory Module ammonia system quick disconnects (QDs) led to the need for a process to quantify total leakage without removing the QDs from the system. An innovative solution was proposed allowing quantitative leak rate measurement at ambient external pressure without QD removal. The method utilizes a helium mass spectrometer configured in the detector probe mode to determine helium leak rates inside a containment hood installed on the test component. The method was validated through extensive developmental testing. Test results showed the method was viable, accurate and repeatable for a wide range of leak rates. The accumulation method has been accepted by NASA and is currently being used by Boeing Huntsville, Boeing Kennedy Space Center and Boeing Johnson Space Center to test welds and valves and will be used by Alenia to test the Cupola. The method has been used in place of more expensive vacuum chamber testing which requires removing the test component from the system.

Underwood, Steve D.↗

Further Characterization of an Active Clearance Control Concept

A new test chamber and precision hydraulic actuation system were incorporated into an active clearance control (ACC) test rig at NASA Glenn Research Center. Using the improved system, a fast-acting, mechanically-actuated, ACC concept was evaluated at engine simulated temperatures and pressure differentials up to 1140 F and 120 psig, on the basis of secondary seal leakage and kinematic controllability. During testing, the ACC concept tracked a simulated flight clearance transient profile at 1140 F, 120 psig, with a maximum error of only 0.0012 in. Comparison of average dynamic leakage of the system with average static leakage did not show significant differences between the two operating conditions. Calculated effective clearance values for the rig were approximately 0.0002 in. at 120 psig, well below the industry specified effective clearance threshold of 0.001 in.

Taylor, Shawn C.↗

Exploration Atmosphere Demonstration of A Multi-Functional Integrated Medical Device (Tempus Pro)

INTRODUCTION The Exploration Medical Capability (ExMC) element within the Human Research Program and the Exploration Medical Integrated Product Team (XMIPT) within the Mars Campaign Office seek to advance medical system design and risk-informed decision-making for exploration missions. This includes assessment of candidate devices and their compatibility within a variety of increasingly Earth-independent medical scenarios. The Tempus Pro (Remote Diagnostic Technologies, Ltd., Philips Corp., Farnborough, UK) is a commercial-off-the-shelf (COTS), multi-functional integrated medical device capable of vital signs monitoring, with built-in procedure support (iAssist), patient record and telemedicine communication features, and medical imaging (e.g., camera, laryngoscope, ultrasound) that meets multiple exploration medical capability needs. One of several hypobaric atmospheres being considered for exploration vehicles is 8.2 psi with 34% oxygen. To assess the useability of the Tempus Pro in such environments by individuals without formal medical training, the unit was tested in May and June of 2023 at the Johnson Space Center 20-Foot Exploration Atmosphere Chamber in conjunction with the Exploration Atmospheres-2 (EA-2) study. TECHNOLOGY DEMONSTRATION Eight subjects in the EA-2 study were assigned roles as the caregiver or patient – or both in the case of a self-exam – and caregivers were asked to place sensors for 3-Lead ECG, non-invasive blood pressure (NIBP), pulse oximetry (SpO2), and temperature using Tempus Pro’s iAssist. Depending on the procedure, additional tasks included an oropharyngeal exam of the throat with the laryngoscope and capturing ultrasound images of a cardiac subxiphoid view or of the user’s choice from a pre-specified list. Scenarios ranged from remote-guided to fully autonomous operations and surveyed the effectiveness of support, amount of support desired, and importance of support by type (e.g., written crew procedures, iAssist and device guidance, remote console guidance, etc.). Feedback from the subjects and the support personnel was also gathered to inform future designs for training and support and to determine what operations are plausible given different levels of each. An unweighted NASA task load index (TLX) was used to profile the demands of using the device, however the sample size does not support statistics. The research was exploratory in nature and qualitative information was the main goal. Calibration checks on the Tempus Pro were conducted before and after chamber testing to ensure the device was in useable condition. RESULTS All subjects performed their tasks successfully and found the Tempus Pro easy to use with the support provided. The calibration checks outside the chamber showed that the Tempus Pro remained unchanged and measurements inside the chamber were within normal values. Caregivers taking the NASA TLX reported mean scores ≤ 41/100 showing the tasks to be undemanding and less demanding with repeated use (~20/100). Novice users were able to easily connect sensors and take vital signs with the guidance from Tempus Pro’s iAssist feature. For more complex tasks, such as the oropharyngeal exam and ultrasound image acquisition, guidance beyond iAssist was needed, primarily from a supporting physician. Feedback on the importance of support types varied by person and scenario but greater than 50% of the support used by each was non-native to the device. Overall opinions were positive, but the ultrasound users expressed a lack of confidence in their results and 3 out of 4 desired more time, training, or support. Subjects found the sensors to be comfortable and comparable to prior experiences with such devices, except for the blood pressure cuff, which squeezed too tightly for uncomfortably long periods. Many observations provoked discussion, especially regarding ultrasound, that will aide decisions about future demonstrations.

R. S. Miller↗

Graphic Three-Axes Presentation of Residual Gas Analyser Data

Residual gas analyzers (RGA) are commonly used to measure the composition of residual gases in thermal-vacuum test chambers. Measurements from RGAs are often used to identify and quantify outgassing contaminants from a test article during thermal-vacuum testing. RGA data is typically displayed as snapshots in time, showing instantaneous concentrations of ions from ionized residual gas molecules at different atomic masses. A method was devised by the authors to present RGA data in a three-axis format, plotting atomic mass unit (AMU), ion concentration as a function of AMU, and time, to provide a clear graphic visualization ot trends in gas concentration changes and to initiate a valuable analytical tool to interpret test article outgassing rates during thermal-vacuum testing.

data analysis↗

NASA Glenn Propulsion Systems Lab (PSL) Icing Facility Update

The NASA Glenn Research Center Propulsion Systems Lab (PSL) was recently upgraded to perform engine inlet ice crystal testing in an altitude environment. The system installed 10 spray bars in the inlet plenum for ice crystal generation using 222 spray nozzles. As an altitude test chamber, PSL is capable of simulation of in-flight icing events in a ground test facility. The system was designed to operate at altitudes from 4,000 ft. to 40,000 ft. at Mach numbers up to 0.8M and inlet total temperatures from -60F to +15F.

Calibrating↗

Bearing Starting Torque Measurements Down to –100°C

Starting torque was measured for three different bearings from 0°C down to 90°C and 100°C. These are bearings of the type that will be used in the ice-penetrating radar instrument named Radar for Europa Assessment and Sounding: Ocean to Near-surface (REASON), which is part of the planned science instrument suite for the National Aeronautics and Space Administration (NASA) Europa Clipper mission. This space science mission to Jupiter’s moon, Europa, is being led by NASA’s Jet Propulsion Laboratory (JPL), which is administered for NASA by the California Institute of Technology (Caltech). In addition to presenting the starting torque measurements at various temperatures, this paper will describe the small test chamber and attachments that allowed the measurements to be made using an existing bearing torque testing machine.

Tao, Frank↗

Test Facilities for SHERLOC Laser Development

The Scanning Habitable Environments with Raman and Luminescence for Organics and Chemicals (SHERLOC) instrument is a deep UV laser based spectrometer that is part of NASA’s Mars Perseverance rover. The laser is a pulsed 248.6 nm NeCu hollow cathode gas discharge laser. The design, development, and testing of lasers and laser power supplies (LPS) were performed by scientists and engineers at the Jet Propulsion Laboratory (JPL) and Photon Systems Inc. (PSI). While these lasers had been used previously in extreme terrestrial environments, before they had to be qualified for operation and functionality over the expected range of environmental situations (temperature cycling, vibration, mechanical shock, low pressure corona emission testing) over the course of mission life time. The SHERLOC laser/LPS testing facilities consisted of custom-tailored environmental test chambers with metrology/control electronics. A custom LabVIEW software package was developed to autonomously operate all test facilities using a multi-threaded, object-oriented programming architecture, tasked with interfacing with many instruments simultaneously for operation and data acquisition.

Houck, Andrew↗

Development of a Weather Robust Microphone Configuration for Sonic Boom Measurements

This paper discusses ongoing development and testing of ground-based, weather-robust microphone measurement systems in conjunction with preparation for community testing of the NASA X-59 quiet supersonic aircraft. Prior efforts [Anderson et al., Proc. Mtgs. Acoust. 42, 040005 (2022)] resulted in the refinement of a ground-plate setup by investigating varied windscreen and plate diameters and thicknesses. The most recent goal has been to make the setup more compact and easier to manufacture. This paper discusses the results of additional tests performed on updated designs meant to find the balance between compactness and performance. Anechoic chamber testing was performed to examine ground plate and windscreen performance and to compare results against prior versions. Outdoor tests included measurements during different wind conditions and over different ground surfaces to examine low-frequency wind noise reduction and ground impedance effects. Results discussed during the presentation suggest the new design strikes an acceptable compromise between compactness, manufacturing ease and robustness, and performance. [Work supported by NASA Langley Research Center through Analytical Mechanics Associates]

sonic boom↗

Effects of Mild Hypobaric Hypoxia on Visual Field Impairment

INTRODUCTION: The primary objective of the Exploration Atmosphere (EA) study is to validate a new prebreathe protocol necessary before exposure to a suited hypobaric environment during extravehicular activity (EVA) from a habitat ‘exploration atmosphere’ of 56.5kPa (8.2 psia), 34% O2, 66% N2. Prebreathe protocols must be time and resource efficient while also controlling Decompression Sickness (DCS) risk to within acceptable limits. The habitat hypobaric exploration atmosphere also results in a mildly hypoxic environment (piO2 = 128mmHg). As a secondary objective of the EA study, we characterized the effects of 11-day exposure to a mild hypobaric hypoxic environment on visual performance. METHODS: Two, 11-day hypobaric chamber tests were performed (EA-1and EA-2, n=8 each) in NASA’s 20-foot chamber at Johnson Space Center where subjects lived in the exploration atmosphere. Subjects also underwent simulated 6-hour EVAs at 85% O2 and 29.6 kPa during EVA on days 3, 5, 7, 9, and 11. Visual acuity (VA), a measure of spatial resolution, and contrast sensitivity (CS), a measure of ability to distinguish ever finer increments of brightness, were assessed on non-EVA days by using gapped Landolt C testing. The luminance was controlled by using a booth, a light monitor, and a lighting rheostat. EA-1 data had revealed problems in lighting control impacting consistency of the data. Procedures were subsequently updated for the EA-2 test. RESULTS: EA-1 data revealed large variance and data recording errors and was removed from the analysis. One participant left the study at Test Day 3 during EA-2. EA-2 ANOVA results showed CS (mean change=0.010 logCSWeber) and VA (mean change, -0.016 logMAR) between pre-test and 11-day test phases; however, neither VA nor CS changes were statistically significant. There were non-statistically significant declines in VA across test phases. DISCUSSION: Overall, visual field performance did not exhibit clinically significant changes (3 lines or greater change in LogMar chart) during exposure to the mild hypoxic exploration atmosphere environment compared to pre-test baseline. The consistency and stability of VA data during EA-2 suggests that the mild hypobaric hypoxic environment did not cause clinically significant negative impacts to participants’ visual field performance.

Visual Acuity↗

Effects of Mild Hypobaric Hypoxia on Visual Field Impairment

INTRODUCTION: The primary objective of the Exploration Atmosphere (EA) study is to validate a new prebreathe protocol necessary before exposure to a suited hypobaric environment during extravehicular activity (EVA) from a habitat ‘exploration atmosphere’ of 56.5kPa (8.2 psia), 34% O2, 66% N2. Prebreathe protocols must be time and resource efficient while also controlling Decompression Sickness (DCS) risk to within acceptable limits. The habitat hypobaric exploration atmosphere also results in a mildly hypoxic environment (piO2 = 128mmHg). As a secondary objective of the EA study, we characterized the effects of 11-day exposure to a mild hypobaric hypoxic environment on visual performance. METHODS: Two, 11-day hypobaric chamber tests were performed (EA-1and EA-2, n=8 each) in NASA’s 20-foot chamber at Johnson Space Center where subjects lived in the exploration atmosphere. Subjects also underwent simulated 6-hour EVAs at 85% O2 and 29.6 kPa during EVA on days 3, 5, 7, 9, and 11. Visual acuity (VA), a measure of spatial resolution, and contrast sensitivity (CS), a measure of ability to distinguish ever finer increments of brightness, were assessed on non-EVA days by using gapped Landolt C testing. The luminance was controlled by using a booth, a light monitor, and a lighting rheostat. EA-1 data had revealed problems in lighting control impacting consistency of the data. Procedures were subsequently updated for the EA-2 test. RESULTS: EA-1 data revealed large variance and data recording errors and was removed from the analysis. One participant left the study at Test Day 3 during EA-2. EA-2 ANOVA results showed CS (mean change=0.010 logCSWeber) and VA (mean change, -0.016 logMAR) between pre-test and 11-day test phases; however, neither VA nor CS changes were statistically significant. There were non-statistically significant declines in VA across test phases. DISCUSSION: Overall, visual field performance did not exhibit clinically significant changes (3 lines or greater change in LogMar chart) during exposure to the mild hypoxic exploration atmosphere environment compared to pre-test baseline. The consistency and stability of VA data during EA-2 suggests that the mild hypobaric hypoxic environment did not cause clinically significant negative impacts to participants’ visual field performance.

Visual Acuity↗

Chemical Challenge Tests on ISS Fire Cartridges

Following a confirmed combustion event onboard the International Space Station (ISS), crewmembers will don Emergency Masks, each fitted with 2 ISS fire cartridge filters. As the crewmember breathes through the filters, combustion products in the cabin air are either filtered or catalyzed by the fire cartridge media to minimize crew exposure to harmful levels of contaminants. Rigorous certification, acceptance, and surveillance programs for the fire cartridges ensure that each lot meets stringent performance requirements during the beginning of and throughout the service life of the cartridges. In accordance with the Quality/Acceptance Test Plan, multiple fire cartridges from each lot undergo chemical challenge tests, with each test lasting 2.5 hours and involving one or more chemicals at specified concentrations. These tests are conducted at specific temperatures, humidity levels, and gas flow rates intended to mimic the worst-case conditions for fire cartridge performance. These challenge tests are conducted by the Environmental Chemistry Laboratory at the NASA Lyndon B. Johnson Space Center. The majority of the challenge tests focus on carbon monoxide (CO), but other gases include hydrogen cyanide (HCN), hydrogen chloride (HCl), cyclohexane, acrolein, and acetaldehyde. A fire cartridge is exposed to the test gas in a test chamber at the specified conditions and the outlet is monitored for breakthrough during the 2.5-hour test. This paper will briefly introduce fire cartridges and how they work, then discuss details of the challenge gas delivery and exposure system, breakthrough monitoring methods, and discussion of issues that have arisen during the course of the test program. Although the focus of this paper will be on the conduction of the challenge tests, a general summary of the performance of the fire cartridges will be provided.

Fire Cartridge↗

The Heliopause Electrostatic Rapid Transit System (HERTS) Design, Trades, and Analyses Performed in the First Year of a Two Year Investigation

The Heliopause Electrostatic Rapid Transit System (HERTS)1 was one of the seven total Phase II NASA Innovative Advanced Concepts (NIAC) that was down-selected in 2015 for continued funding and research. In Phase I we learned that a spacecraft propelled by an Electric Sail (E-Sail) can travel great astronomical distances, such as to the Heliopause region of the solar system (approx.100 to 120 AU) in approximately one quarter of the time (10 years) versus the time it took the Voyager spacecraft launched in 1977 (36 years). The current work within the Phase II NIAC effort builds upon the work that was done in the Phase I NIAC and is focused on: 1) Testing of plasma interaction with a charged wire in a unique MSFC test chamber, 2) Development of a Particle-in-Cell (PIC) models that are validated in the plasma testing and used to extrapolate to the E-Sail propulsion system design. 3) Further down select of a wire deployment and control approach from those narrowed down in the Phase I effort. This paper will document the findings to date (June, 2016) of the above focused areas.

Wiegmann, Bruce M.↗

The Heliopause Electrostatic Rapid Transit System (HERTS) Design, Trades, and Analyses Performed in a Two Year NASA Investigation of Electric Sail Propulsion Systems

The Heliopause Electrostatic Rapid Transit System (HERTS) was one of the seven total Phase II NASA Innovative Advanced Concepts (NIAC) that was down-selected in 2015 for continued funding and research. In Phase I our team learned that a spacecraft propelled by an Electric Sail (E-Sail) can travel great astronomical distances, such as to the Heliopause region of the solar system (approx. 100 to 120 AU) in approximately one quarter of the time (10 years) versus the time it took the Voyager spacecraft launched in 1977 (36 years). The completed work within the Phase II NIAC funded effort builds upon the work that was done in the Phase I NIAC and is focused on: 1) Testing of plasma interaction with a charged wire in a MSFC simulated solar environment vacuum test chamber. 2) Development of a Particle-in-Cell (PIC) models that are validated in the plasma testing and used to extrapolate to the E-Sail propulsion system design. 3) Conceptual design of a Technology Demonstration Mission (TDM) spacecraft developed to showcase E-Sail propulsion systems. 4) Down selection of both: a) Materials for a multi km length conductor and, b) Best configuration of the proposed conductor deployment subsystem. This paper will document the findings to date (June, 2017) of the above focused areas.

Wiegmann, Bruce M.↗

Space Power Facility Readiness for Space Station Power System Testing

This document provides information which shows that the NASA Lewis Research Center's Space Power Facility (SPF) will be ready to execute the Space Station electric power system thermal vacuum chamber testing. The SPF is located at LeRC West (formerly the Plum Brook Station), Sandusky, Ohio. The SPF is the largest space environmental chamber in the world, having an inside horizontal diameter of 100 ft. and an inside height at the top of the hemisphere of 122 ft. The vacuum system can achieve a pressure lower than 1 x 10(exp -5) Torr. The cryoshroud, cooled by gaseous nitrogen, can reach a temperature of -250 F, and is 80 ft. long x 40 ft. wide x 22 ft. high. There is access to the chamber through two 50 ft. x 50 ft. doors. Each door opens into an assembly area about 150 ft. long x 70 ft. wide x 80 ft. high. Other available facilities are offices, shop area, data acquisition system with 930 pairs of hard lines, 7 megawatts of power to chamber, 245K gal. liquid nitrogen storage, cooling tower, natural gas, service air, and cranes up to 25 tons.