In-pile thermal conductivity of uranium dioxide at low burnup

In-pile thermal conductivity of uranium dioxide (UO 2 ) was investigated at low burnup levels (<0.2 kWd/kg-UO 2 ) to elucidate the concurrent effects of the fission damage and the thermal recovery. In-pile experiments were performed in the Halden reactor. The fuel centerline and the cladding temperatures were measured during the experiments, and the power level of specially designed test rodlets were also monitored. The uncertainty of the pellet-cladding gap's thermal resistivity was minimized with a liquid-metal bond, while comparable measurements were made in reference test rodlets without liquid metal bonding. The experimental data were analyzed using the inverse heat transfer approach. The heat conduction equation was solved by applying the measured temperature of the cladding as a boundary condition, and the calculated fuel centerline temperature was compared with the measured fuel centerline temperature to determine the relative matrix resistivity. Results showed that the in-pile matrix resistivity, the phonon-lattice interaction terms of the thermal conductivity, was ~1.5–2.5 times higher than its unirradiated value due to fission-induced damage. Finally, the in-pile annealing caused a significant recovery of the matrix resistivity, and the amount of recovery increased from ~20 to ~33%, while the annealing temperature increased from 700 to 1,000 °C.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Cross-Linker Selection Controls Glass Transition Elevation or Reduction in Dynamic Covalently Bonded Polymer Networks

Introducing cross-links is a powerful approach to improve polymeric material performance relevant to controlling viscoelasticity, thermal and creep resistance, degradability, and efficient membrane separations. The chemically specific glass transition temperature T g is of fundamental importance in determining the time scales of key dynamical processes and physical state of the material in such applications. Here, we study experimentally how the introduction of relatively large cross-linking molecules in slowly exchanging dynamic bond-forming polymers (vitrimers) impacts vitrification for diverse polymer chemistries and a wide range of cross-link fractions. We find T g can increase, decrease, or even remain essentially unchanged, in qualitative contrast to the generic elevation of T g in traditional permanent polymer networks. We formulate an effective terpolymer network model to understand this rich behavior, which emerges as a consequence of a competition between pure cross-linking and generalized plasticization effects. The latter is associated with the tunable cross-linker size and intrinsic dynamic mobility that can offset slowing down due to traditional permanent cross-linking constraints. Here, a new strategy for functional polymer network design is suggested based on adjusting the relative importance of the two competing physical effects, which potentially can significantly enhance energy savings in applications while retaining other intrinsic properties germane to advanced materials performance.

Copolymers↗

Microstructure & Mechanical Properties of Scaled Thermally Aged LPBF 316H SS Builds

As part of the US Department of Energy’s Advanced Materials and Manufacturing Technologies program’s mission to accelerate qualification of advanced manufacturing pathways for nuclear applications, laser powder bed fusion (LPBF) 316H stainless steel (SS) has been selected as a model system to develop a rapid code case framework. This effort directly addresses the grand challenges of (1)expanding the limited portfolio of materials currently codified for elevated-temperature nuclear structural service under Section III, Division 5of the American Society of Mechanical Engineers’ Boiler and Pressure Vessel Code; and (2) significantly reducing qualification timelines that traditionally exceed a decade. The strategic importance of LPBF 316H lies in its immediate industrial relevance, existing data foundation from wrought 316H, and alignment with ongoing code case development for LPBF 316L.Prior work revealed accelerated precipitation of deleterious secondary phases and reduced creep ductility in as-printed LPBF 316H. Building on that prior research, FY2025activities focused on establishing an understanding of the key failure mechanisms of crept 316H specimens to aid in code case development and on evaluating stress relief (SR) parameters on the high-temperature performance and thermal aging-induced degradation of tensile and fracture behavior in LPBF316H.

36 MATERIALS SCIENCE↗

Experimental Aging and Lifetime Prediction in Grid Applications for Large-Format Commercial Li-Ion Batteries

Due to the growth of electric vehicle and stationary energy storage markets, the production and use of lithium-ion batteries has grown exponentially in recent years. For many of these applications, large-format lithium-ion batteries are being utilized, as large cells have less inactive material relative to their energy capacity and require fewer electrical connections to assemble into packs. And especially for stationary energy storage systems, where energy delivered is the only revenue source, the economics of these battery systems is highly dependent on cell lifetime. However, testing of large-format lithium-ion batteries is time consuming and requires high current channels and large testing chambers, making information on the performance of commercial, large-format lithium-ion batteries hard to come by. Here, accelerated aging test data from four commercial large-format lithium-ion batteries is reported. These batteries span both NMC-Gr and LFP-Gr cell chemistries, pouch and prismatic formats, and a range of cell designs with varying power capabilities. Accelerated aging test results are analyzed to examine both cell performance, in terms of efficiency and thermal response under load, as well as cell lifetime. Cell thermal response is characterized by measuring temperature during cycle aging, which is used to calculated a normalized thermal resistance value that may help estimate both cell cooling needs or to help extrapolate aging test results to different thermal environments. Cell lifetime is evaluated qualitatively, considering simply the average calendar and cycle life across a range of conditions, as well as quantitatively, using statistical modeling and machine-learning methods to identify predictive aging models from the accelerated aging data. These predictive aging models are then used to investigate cell sensitivities to stressors, such as cycling temperature, voltage window, and C-rate, as well as to predict cell lifetime in various stationary storage applications. Results from this work show that cell lifetime and sensitivity to aging conditions varies substantially across commercial cells, necessitating testing for specific cell formats to make quantitative lifetime predictions. That being said, all commercial cells tested here are predicted to reach at least 10-year lifetimes for stationary storage applications. Based on the aging test results and modeling, some cells are expected to be relatively insensitive to temperature and use-case, making them suited for simple use cases with little or no thermal management and simple controls, while the lifetime of other cells could be extended to 20+ years if operated with thermal management and degradation-aware controls.

battery↗

Quantification of the importance of the modeling fidelity in the Best Estimate Plus Uncertainty analysis

In this work, the multi-physics coupling of CTF-PARCS for both steady-state and transient simulations is evaluated focusing on the quantification of the importance of the modeling fidelity when applied to the Best Estimate Plus Uncertainty safety analysis. For the steady-state, a Picard iteration approach is adopted in the coupled code while for the transient an explicit approach has been developed as a first step. The CTF-PARCS coupling is applied to the REA at HFP BOC scenario proposed in the exercise I-2c of LWR-UAM benchmark Phase III. Two different modeling choices are investigated for the nominal calculations. The first consists of including the 3D burnup information in CTF, and the second of modeling the spacers grids in both PARCS and CTF. It is observed that due to the degradation of the fuel thermal conductivity, the 3D burnup inclusion in CTF leads to significant higher centerline temperatures than the base case, with a difference up to 300 K. The spacer grids modeling shows the expected power and temperature decrease in the axial positions of the spacer grids. For the uncertainty quantification study, the multi-physics modeling including the burnup information in CTF is used. The results show that the inserted reactivity has a relative standard deviation of 13.6% mainly attributed to the nuclear data. The maximum linear power has a relative standard deviation of 16.2% due to the nuclear data as well, while the maximum centerline temperature has a relative standard deviation of 3.5% primarily caused by the fuel thermal conductivity. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Pool Boiling Reliability Tests and Degradation Mechanisms of Microporous Copper Inverse Opal (CuIOs) Structures

The rising power density in electronic systems requires thermal management solutions that are both high-performing and reliable. Porous materials such as Copper Inverse Opal (CuIOs) have unique structural features, including high permeability and high thermal conductivity, to enhance pool boiling performance. However, there is little understanding of the degradation mechanism of such porous materials under pool boiling conditions. In this study, samples of 10 ..mu..m thick CuIOs with 4.8 ..mu..m diameter, covering silicon substrate of area 11 mm x 11 mm, with various heated areas ranging from 2.5 mm x 2.5 mm to 10 mm x 10 mm, were tested in 100 degrees C deionized water at a constant heat flux of 110 Wcm -2 for 3-to-7 days. The combined effect of erosion and corrosion caused structural degradation of the CuIOs. The directly heated area had the most severe degradation while the edge of the heater and the unheated area showed progressively less degradation, maintaining some CuIOs structure even after the 7-day reliability test. Among all the tested samples with various heater sizes, the 2.5 mm x 2.5 mm heater sample - in which the heater size was designed to be comparable to the water bubble characteristic length - had the largest critical heat flux (CHF) up to 300 Wcm -2 with a superheat ~ 13 degrees C. Additionally, CuIOs with a smaller heated area performed better in terms of reliability. This study offers preliminary insights into CuIOs degradation mechanisms, contributing to the development of more robust thermal management solutions. We expect that electroless plating of CuIOs with gold (Au), nickel (Ni), and atomic layer deposition (ALD) aluminum oxide (Al 2 O 3 ) in combination with appropriate application-specific coolants will further improve the reliability and lifetime of the CuIOs.

boiling-induced degradation↗

Responses of Boreal Forest Ecosystems and Permafrost to Climate Change and Disturbances: A Modeling Perspective

The north circumpolar region contains a large amount of carbon. This carbon storage is vulnerable due to permafrost degradation and wildfire disturbances under ongoing and projected climate change. Climate warming and wildfires change soil organic horizons gradually or abruptly, and modify permafrost thermal-hydrology and biogeochemistry, ecosystem structures, functions, and capability of sequestrating rising atmospheric CO2. Land models do not fully take accounts of these interactions and its complexity in the high latitude. This chapter describes a terrestrial ecosystem model with dynamic organic soil module (DOS-TEM) and its unique freezing-thawing algorithm, and presents key results of its applications mainly in boreal forests of Alaska. The DOS-TEM explicitly considers interactions of soil thermal and hydrological processes, permafrost degradation and the direct and indirect effects of wildfire disturbances, in addition to soil–plant C and N cycles. We first introduce four modules of DOS-TEM, focusing on its disturbance module and coupling with a dynamic organic soil module. Then we describe and validate DOS-TEM’s freezing-thawing algorithm and development based on two-directional Stefan algorithm (TDSA). Finally, we apply the DOS-TEM at site and region scales, with a focus on model ability to dynamically simulate soil organic thickness under warming and wildfires, and consequent impacts on permafrost in the Yukon River Basin. We conclude that land surface model development is urgently needed to include other critical landscape processes, such as thermalkarst and other disturbances, to synchronize thermal-hydrological-biogeochemical processes, and to incorporate an advanced understanding of biospheric feedbacks to atmosphere and ecosystems. Such a complexity of modeling scope is plausible with advancement of high performance computing.

Yi, Shuhua↗

Pool Boiling Reliability Tests and Degradation Mechanisms of Microporous Copper Inverse Opal (CuIOs) Structures: Preprint

The rising power density in electronic systems requires thermal management solutions that are both high-performing and reliable. Porous materials such as Copper Inverse Opals (CuIOs) have unique structural features, including high permeability and high thermal conductivity, to enhance pool boiling performance. However, there is little understanding of the degradation mechanism of such porous materials under pool boiling conditions. In this study, samples of 10-micrometer-thick CuIOs with 4.8-micrometer diameter, covering silicon substrate of area 11-mm by 11-mm, with various heated areas ranging from 2.5-mm by 2.5-mm to 10-mm by 10-mm, were tested in 100 degrees C deionized water at a constant heat flux of 110 watts per square cm for 3-7 days. The combined effect of erosion and corrosion caused structural degradation of the CuIOs. The directly heated area had the most severe degradation while the edge of the heater and the unheated area showed progressively less degradation, maintaining some CuIOs structure even after the 7-day reliability test. Among all the tested samples with various heater sizes, the 2.5-mm by 2.5-mm heater sample - in which the heater size was designed to be comparable to the water bubble characteristic length - had the largest critical heat flux (CHF) up to 300 watts per square cm with a superheat of approximately 13 degrees C. Additionally, CuIOs with a smaller heated area performed better in terms of reliability. This study offers preliminary insights into CuIOs degradation mechanisms, contributing to the development of more robust thermal management solutions. We expect that electroless plating of CuIOs with gold (Au), nickel (Ni), and atomic layer deposition of aluminum oxide in combination with appropriate application-specific coolants will further improve the reliability and lifetime of the CuIOs.

boiling-induced degradation↗

Gaining insight into lithium-ion battery degradation by a calorimetric approach

With the growing demand for lithium-ion batteries (LIBs) in transportation and renewable energy sectors, ensuring reliability and mitigating degradation are crucial challenges for their widespread deployment. Here this study investigates the relationship between thermal characteristics and degradation/reliability by developing an in-situ heat measurement methodology for LIBs operating under grid services. Using adiabatic mode-based calorimetry, we examine the thermal behavior of two commercial cells with different cathode chemistries (Ni-rich layered oxide and olivine) before and after two years of grid service (peak shaving) and demonstrate a strong correlation between thermal characteristics and electrochemical performance and its degradation. By further analyzing the heat sources separation (differentiating between irreversible and reversible heat), we disclose the underlying degradation mechanisms of LIBs. These findings emphasize the critical role of thermal characteristics in determining LIB reliability and deterioration, while the obtained heat data can aid in the development and calibration of LIB state-of-health models for grid applications.

25 ENERGY STORAGE↗

Degradation and Accelerated Recovery of Surface Passivation in n+, p+, and Intrinsic Poly-Si/SiOx Passivating Contacts for Silicon Solar Cells

We report on the degradation and recovery of surface passivation of fired poly-Si/SiOx passivating contacts with hydrogen containing Al2O3 during annealing in the dark and under illumination. Upon firing to a peak temperature of 670 degrees C, the iVoc for symmetric test structures with n+, p+, and intrinsic poly-Si/SiOx contacts decreases due to a loss of surface passivation. Upon further annealing over the temperature range of 200-350 degrees C in the dark, depending on the type of doping, the surface passivation either shows further degradation followed by recovery, or direct recovery to the initial iVoc. Annealing at higher temperatures and/or higher illumination intensities accelerates the kinetics for both degradation and recovery processes. We show that the degradation and recovery processes are thermally activated and proceed identically in subsequent firing and annealing steps showing their cyclic nature. We present a series reaction model to explain the kinetics of degradation and recovery processes for n+ and intrinsic poly-Si/SiOx contacts. By fitting the model's rate expressions to the data, the determined effective activation energy barriers for degradation and recovery for n+ poly-Si/SiOx contacts in the dark are 1.24 and 1.51 eV, which are lowered under 7.5 Suns illumination to 0.76 and 1.15 eV, respectively.

14 SOLAR ENERGY↗

Iso-cost-performance of thermal energy storage

As thermal energy storage (TES) systems gain increasing recognition as next-generation energy storage solutions, evaluating their techno-economic performance is crucial. This perspective analyzes the cost-performance of latent heat-based TES systems and introduces the concept of iso-cost-performance—maintaining a constant cost per unit energy ($\$$/kWh) despite material degradation. Using an empirical degradation model, we show that after 1200 thermal cycles, the thermal conductivity and volumetric energy density of a paraffin-based phase change material (PCM) decreased by 36.0% and 26.1%, respectively, resulting in a 31.2% reduction in the figure of merit (FOM) and, consequently, the system cost-performance. However, by introducing thermally conductive additives to enhance effective thermal conductivity, the TES system can recover its initial FOM, achieving iso-cost-performance operation. This framework quantitatively demonstrates how degradation-mitigation strategies—such as improving thermal conductivity—can offset material degradations and maintain long-term cost-effectiveness. Beyond PCM-based TES, the proposed FOM-based approach provides a generalized pathway for cost-performance optimization across various TES technologies.

25 ENERGY STORAGE↗

From Femtoseconds to Gigaseconds: The SolDeg Platform for the Performance Degradation Analysis of Silicon Heterojunction Solar Cells

Heterojunction Si solar cells exhibit notable performance degradation. Here, we modeled this degradation by electronic defects getting generated by thermal activation across energy barriers over time. To analyze the physics of this degradation, we developed the SolDeg platform to simulate the dynamics of electronic defect generation. First, femtosecond molecular dynamics simulations were performed to create a-Si/c-Si stacks, using the machine learning-based Gaussian approximation potential. Second, we created shocked clusters by a cluster blaster method. Third, the shocked clusters were analyzed to identify which of them supported electronic defects. Fourth, the distribution of energy barriers that control the generation of these electronic defects was determined. Fifth, an accelerated Monte Carlo method was developed to simulate the thermally activated time-dependent defect generation across the barriers. Our main conclusions are as follows. (1) The degradation of a-Si/c-Si heterojunction solar cells via defect generation is controlled by a broad distribution of energy barriers. (2) We developed the SolDeg platform to track the microscopic dynamics of defect generation across this wide barrier distribution and determined the time-dependent defect density N(t) from femtoseconds to gigaseconds, over 24 orders of magnitude in time. (3) We have shown that a stretched exponential analytical form can successfully describe the defect generation N(t) over at least 10 orders of magnitude in time. (4) We found that in relative terms, Voc degrades at a rate of 0.2%/year over the first year, slowing with advancing time. (5) We developed the time correspondence curve to calibrate and validate the accelerated testing of solar cells. We found a compellingly simple scaling relationship between accelerated and normal times t normal ∝ t accel T(accel)/T(normal) . (6) We also carried out experimental studies of defect generation in a-Si:H/c-Si stacks. We found a relatively high degradation rate at early times that slowed considerably at longer time scales.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Modeling Photolytic Decomposition of Energetically Functionalized Dodecanes

The photolytic stability of explosives and energetic functional groups is of importance for those who regularly handle or are exposed to explosives in typical environmental conditions. This study models the photolytic degradation of dodecane substituted with various energetic functional groups: azide, nitro, nitrate ester, and nitramine. For the studied molecules, it was found that excitons localize on the energetic functional group, no matter where they were initially formed, and thus, the predominant degradation pathway involves the degradation of the energetic functional group. The relative trends for both 4 and 8 eV excitation energies followed with what is expected from the relative stability of the energetic functional groups to thermal and sub-shock degradation. The one notable exception was the azide functional group; more work should be done to further understand the photolytic effects on the azide functional group.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Chiral-structured heterointerfaces enable durable perovskite solar cells

Mechanical failure and chemical degradation of device heterointerfaces can strongly influence the long-term stability of perovskite solar cells (PSCs) under thermal cycling and damp heat conditions. Here, we report chirality-mediated interfaces based on R-/S-methylbenzyl-ammonium between the perovskite absorber and electron-transport layer to create an elastic yet strong heterointerface with increased mechanical reliability. This interface harnesses enantiomer-controlled entropy to enhance tolerance to thermal cycling–induced fatigue and material degradation, and a heterochiral arrangement of organic cations leads to closer packing of benzene rings, which enhances chemical stability and charge transfer. The encapsulated PSCs showed retentions of 92% of power-conversion efficiency under a thermal cycling test (-40°C to 85°C; 200 cycles over 1200 hours) and 92% under a damp heat test (85% relative humidity; 85°C; 600 hours).

14 SOLAR ENERGY↗

Assessing the Impact of Effective Thermal Conductivity on Gas-cooled Reactor Transients in RELAP5-3D

In block-type high-temperature gas-cooled reactors (HTGRs), coolant holes in blocks lead to a reduction in heat transfer through conduction. In systems codes like RELAP5-3D, we must account for this degradation by using an effective thermal conductivity (ETC). This presentation discusses a few ETC relationships and demonstrates the impact of ETC for the modular High-Temperature Gas-Cooled Reactor 350 MW -- a computational benchmark for HTGR modeling -- and for the High Temperature Test Facility (HTTF) -- an HTGR thermal hydraulics test facility. We demonstrate that the use of ETC leads to temperatures that are higher than the bulk thermal conductivity of the block material would yield, but these differences have no meaningful impact on the transient performance of the reactors. The ETC also reduces the cooldown rate, leading to more time at elevated temperatures. Overall, while accounting for ETC is important in capturing the physics of the reactor, it is not expected to have a meaningful impact on transient performance.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Low temperature recovery of OFF-state stress induced degradation of AlGaN/GaN high electron mobility transistors

Thermal annealing is a widely used strategy to enhance semiconductor device performance. However, the process is complex for multi-material multi-layered semiconductor devices, where thermoelastic stresses from lattice constant and thermal expansion coefficient mismatch may create more defects than those annealed. We propose an alternate low temperature annealing technique, which utilizes the electron wind force (EWF) induced by small duty cycle high density pulsed current. To demonstrate its effectiveness, we intentionally degrade AlGaN/GaN high electron mobility transistors (HEMTs) with accelerated OFF-state stressing to increase ON-resistance ∼182.08% and reduce drain saturation current ∼85.82% of pristine condition at a gate voltage of 0 V. We then performed the EWF annealing to recover the corresponding values back to ∼122.21% and ∼93.10%, respectively. The peak transconductance, degraded to ∼76.58% of pristine at the drain voltage of 3 V, was also recovered back to ∼92.38%. This recovery of previously degraded transport properties is attributed to approximately 80% recovery of carrier mobility, which occurs during EWF annealing. We performed synchrotron differential aperture x-ray microscopy measurements to correlate these annealing effects with the lattice structural changes. We found a reduction of lattice plane spacing of (001) planes and stress within the GaN layer under the gate region after EWF annealing, suggesting a corresponding decrease in defect density. Application of this low-temperature annealing technique for in-operando recovery of degraded electronic devices is discussed.

Physics↗

Degradation of REBCO coated conductors due to a combination of epoxy impregnation, thermal cycles, and quench: Characteristics and a method of alleviation

REBa2Cu3Ox (REBCO) coated conductors are an enabling technology for >1 GHz nuclear magnetic resonance spectrometers that need >23.5 T solenoids, compact high-field fusion reactors beyond the International Thermonuclear Experimental Reactor, and 20 T class accelerator magnets. An in-depth understanding of stress and strain management is critically needed for these applications. Here, we report experimental data and an analysis of damages of REBCO-coated conductors in several scenarios relevant for their applications in high-field magnets and unique to their multi-layer thin film structure. The examined scenarios include failure induced by quench, failure induced by epoxy impregnation, and failure induced by a combination of epoxy impregnation and quench. The root cause is film blistering and peeling induced by thermally interfacial stresses characteristic of multilayered heteroepitaxial thin film structures on thick substrates utilized. The quantitative stress analysis is introduced using simple and easy to use formulas and clearly indicates how materials and structural characteristics affect the magnitude and the distribution of stresses and deflections. Finally, a simple method is introduced for removing degradation of REBCO coated conductors due to epoxy impregnation. Our data and analysis help our understanding of the practical limit of REBCO-coated conductors and can be utilized as a guidance for the physical design of REBCO coated conductors and high-current cables assembled from them and for minimizing damages.

Yin, Shijian (ORCID:0000000224312274)↗