Search NASA⌕ Search

SEARCH · Search NASA

Results for “THERMOCOUPLE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Electromagnetic Thermocouple (TC) Anomaly Mechanisms During Atmospheric Entry

Thermocouples (TCs) are a critical diagnostic sensor for high enthalpy environments including Thermal Protection Systems (TPS) for atmospheric entry, hypersonic wind tunnels, and arc jet test facilities. They are used for both evaluating facility environmental conditions (enthalpy, and heat flux) as well as for measuring in-situ material thermal response under test conditions (thermal conductivity, heat capacity, etc.). Consequently, accurate TC measurements are fundamental for both material and facility Verification and Validation (V&V). However, a number of electromagnetic TC anomalies have been observed in both ground tests and flight instrumentations. These anomalies are caused via various coupling mechanisms: surface voltage coupling, Hall effect currents, and RF rectification. All of these mechanisms can, if unaddressed, result in obviously compromised results or worse, non-physical measurements which appear reasonable. This talk will provide an overview of each of these anomaly mechanisms and discuss ongoing efforts to quantify and mitigate them.

Magnus Haw↗

Error Sources and Mitigation Strategies for Thermocouples Integrated in Flexible Thermal Protection System Materials

Brief Presenter Biography:Ruth Miller is an aer-ospace systems engineer in the Entry Systems and Ve-hicle Development Branch at NASA Ames Research Center.Introduction:The flexible thermal protection sys-tem (FTPS) on NASA’s Low-Earth Orbit Flight Test of an Inflatable Decelerator (LOFTID) vehicle will be in-strumented with thermocouples (TCs) to measure the in-depth thermal response during entry into Earth’s atmos-phere[1, 2]. Accurate flight temperature measurements are critical for verifying vehicle performance during the flight test and reducing uncertainties in the thermal models.However,the deployable nature of inflatable decelerator technology presents challengesfor integrat-ing TCs, specifically the TCsneed to be compactableand cannot damage the FTPSnor the inflatable structure(IS).Unlike traditional rigid aeroshells, routing TCsthrough the thickness of the FTPS could cause signifi-cant damage during packing of the deployable aeroshellbecause the different layers may shift small amounts in relation to each other imparting strain on the TCsand FTPS materials. The LOFTID TCleads are routed from the measurement location back to the data acquisition system in the vehicle centerbody within the same FTPS layer that they are monitoring the temperature. This ap-proach eliminates the need to put holes in the FTPS lay-ers,butas a consequence,the insulated TCleads travel for an appreciable distance through a region that will expose them to high temperaturesand large thermal gra-dients.LOFTID’s TCswere baselined to be commercially available Type K TCswith a binder impregnated glass braid insulation. These TCswere chosen because they had been used successfully on IRVE-3 and in ground-based arc jet testing. Additionally, these TCsdid notdamage the FTPS nor IS during packing and deploy-ment testing. However, the glass braid insulation is only rated to a maximum continuous use temperature of 482ºC. For reference, the duration of the heat pulse on the LOFTID vehicle is on the order of minutes and themaximum predicted temperaturebeneaththe outermost FTPS layersis 1350ºC.Ground-based testing in a tube furnace at NASA Ames Research Centerwas conducted to determine if the baseline TCsrouted through FTPS samples would survive and provide accurate temperature measure-mentsat LOFTID flight-relevant temperatures[3].The test results showed large measurement errors occurred beginning at approximately 400°C due to conductive deposits on the TCinsulation electrically shorting the TCleads.The conductive deposits and thus electrical shorting weredetermined to be caused by twoerror sources:1.The organic binder on the TCinsulation carbon-izingin a high temperature, low oxygen envi-ronment2.Decomposition products from the FTPSperme-atingthe braided TC insulationFurther testing in the tube furnace demonstrated that heat cleaning the TCinsulation effectivelyremovedthe organic binder andeliminatedthe first error source.The second error sourcewas shown to be mitigated by the addition of amica wraparound each individual TCleadtoact as an impermeable barrier.To understand the applicability of theground-based tube furnace test results to flight,anarc jet testseriesat Boeing’s Large Core Arc Tunnel (LCAT) facilitywas conducted[4].The error sourcesand mitigation strate-giesidentified in the tube furnace testing were substan-tiatedin the arc jet testing.However, the arc jet testing also revealed three new error sources:1.Glass TCinsulation meltingwhich resultsin electrical shorting of the TCeither through di-rect contact between the two leads or through the electrically conductive FTPS materials2.TCwire meltingwhich results in a noisy and/or open-loop TCresponse3.Type K TCwire green-rotwhich results in large calibration errors Scope of the Presentation:This presentation will include a brief discussion onthe effect of electrical shorting on the output of a TC(i.e. how to identify elec-trical shorting in TCdataand what the associated erroris).The tube furnace and arc jet test resultswill be dis-cussedand the solutions LOFTID is implementing to mitigate the error sourcesidentified in the tube furnace and arc jet testingwill be presented.Additionally, futureresearch and development work to eliminateTCerror sourcesfor future missionswill be recommended.

R A Miller↗

Error Sources and Mitigation Strategies for Thermocouples Integrated in Flexible Thermal Protection System Materials

• The flexible thermal protection system (FTPS) on NASA’s Low-Earth Orbit Flight Test of an Inflatable Decelerator (LOFTID) vehicle will be instrumented with thermocouples (TCs) to measure the in-depth thermal response during entry into Earth’s atmosphere. Accurate flight temperature measurements are critical for verifying vehicle performance and reducing thermal model uncertainties. • The TC leads are routed from the measurement location to the data acquisition system within the same FTPS layer that they are monitoring the temperature. This approach eliminates the need to put holes in the FTPS layers. However, the insulated TC leads are exposed to high temperatures and large thermal gradients. • The baseline TCs were commercially available 30 AWG Type K TCs with a binder impregnated glass braid insulation. The glass braid is rated to a maximum continuous use temperature of 482°C. LOFTID’s heat pulse will be on the order of minutes and the maximum predicted temperature beneath the outermost FTPS layers is 1350°C.

R. A. Miller↗

Evaluation of the LOFTID Flight Thermocouple Measurements

The Flexible Thermal Protection System (FTPS) on NASA’s Low-Earth Orbit Flight Test of an Inflatable Decelerator (LOFTID) vehicle was instrumented with thermocouples (TC) to measure the in-depth thermal response during entry into Earth’s atmosphere. Accurate flight temperature measurements are critical for verifying vehicle performance during the flight test and reducing uncertainties in the thermal models. The deployable nature of inflatable decelerator technology presents challenges, namely the TCs need to be compactable, cannot damage the FTPS nor the inflatable structure, and need to be able to withstand high temperatures and large thermal gradients over significant running lengths. As previously reported, an extensive ground-test campaign was conducted prior to flight to inform the selection of the LOFTID FTPS TCs which minimized all known potential error sources. Overall, the resulting flight FTPS TC measurements were exceptionally clean throughout the atmospheric entry heat pulse. However, a few of the FTPS TCs still exhibited electrical shorting or other anomalous behavior. This paper presents the flight measurements made by the LOFTID FTPS TCs, identifies anomalous behavior, and discusses potential explanations for the causes of the anomalous behavior. Lastly, recommendations to further mitigate TC measurement error on future Hypersonic Inflatable Aerodynamic Decelerator (HIAD) missions are provided.

Ruth A Miller↗

Correlation of Mixture Temperature Data Obtained from Bare Intake-manifold Thermocouples

A relatively simple equation has been found to express with fair accuracy, variation in manifold-charge temperature with charge in engine operating conditions. This equation and associated curves have been checked by multi cylinder-engine data, both test stand and flight, over a wide range of operating conditions. Average mixture temperatures, predicted by the equations of this report, agree reasonably well with results within the same range of carburetor-air temperatures from laboratories and test stands other than the NACA.

ENGINES-PRATT & WHITNEY R-1830-75 (AMER )↗

TRUST Sensors in Environments: Thermocouples (SE-TC) Report Release FY24

The objective of the Delivery Environments (DE) Testbeds to Reduce Uncertainty in Simulations and Tests (TRUST) project is to quantify and help increase confidence in specific areas of computational and experimental capabilities that are applicable to the development, on-target assessment, and qualification of current and future delivery environments. More complete quantification of confidence in experimental and computational capabilities and the sufficient increase of confidence in those capabilities is critical to improving weapons engineering design, qualification, and assessment efforts that are critical to the current and future stockpile. This work uses and provides feedback on analysis tools and experimental results databases for efficient and responsive engineering which are currently under development.

42 ENGINEERING↗

One-wire thermocouple

Nickel alloy/constantan device accurately measures surface temperature at precise locations. Device is moderate in cost and simplifies fabrication of highly-instrumented seamless-surface heat-transfer models. Device also applies to metal surfaces if constantan wire has insulative coat.

Goodrich, W. D.↗