High-loading low-speed fan study. 4: Data and performance with redesign stator and including a rotor tip casing treatment
A single stage fan with a rotor tip speed of 1000 ft/sec(304.8 m/sec) and a hub-to-tip ratio of 0.392 was retested with a redesigned stator. Tests were conducted with uniform inlet, tip-radial, hub-radial, and circumferential inlet distortions. With uniform inlet flow, stall margin was improved 12 percentage points above that with the original stator. The fan demonstrated an efficiency of 0.883 and a stall margin of 15 percent at a pressure ratio of 1.488 and a specific flow of 41.17 lb/sec/sq ft. Tests were also made with a redesigned casing treatment consisting of skewed slots over the rotor blade tips. This casing treatment gave a 7 percentage point improvement in stall margin when tested with tip radial distortion (when the rotor tip initiated stall). Noise measurements at the fan inlet and exit indicate no effect from closing the stator 10 degrees, nor were there measurable effects from adding skewed slots over the blade tips.