Search NASA⌕ Search

SEARCH · Search NASA

Results for “TRUST”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Trust Your Gut: Comparing Human and Machine Inference from Noisy Visualizations

People commonly utilize visualizations not only to examine a given dataset, but also to draw generalizable conclusions about the underlying models or phenomena. Prior research has compared human visual inference to that of an optimal Bayesian agent, with deviations from rational analysis viewed as problematic. However, human reliance on non-normative heuristics may prove advantageous in certain circumstances. We investigate scenarios where human intuition might surpass idealized statistical rationality. In two experiments, we examine individuals’ accuracy in characterizing the parameters of known data-generating models from bivariate visualizations. Our findings indicate that, although participants generally exhibited lower accuracy compared to statistical models, they frequently outperformed Bayesian agents, particularly when faced with extreme samples. Participants appeared to rely on their internal models to filter out noisy visualizations, thus improving their resilience against spurious data. However, participants displayed overconfidence and struggled with uncertainty estimation. They also exhibited higher variance than statistical machines. Our findings suggest that analyst gut reactions to visualizations may provide an advantage, even when departing from rationality. These results carry implications for designing visual analytics tools, offering new perspectives on how to integrate statistical models and analyst intuition for improved inference and decision-making. The data and materials for this paper are available at https://osf.io/qmfv6

human-machine collaboration↗

SU-E-CAMPUS-T-02: Can Pre-Treatment 4DCT-Based Motion Margins Estimates Be Trusted for Proton Radiotherapy?

Purpose: Radiotherapy motion margins are generated using pre-treatment 4DCT data. The purpose of this study is to assess if pre-treatment 4DCT is sufficient in proton therapy to provide accurate estimate of motion margins. A dosimetric assessment is performed comparing pre-treatment margins with daily-customized margins. Methods: Gold fiducial markers implanted in lung tumors of patients were used to track the tumor. A spherical tumor of diameter 20 mm is inserted into a realistic digital respiratory phantom, where the tumor motion is based on real patient lung tumor trajectories recorded over multiple days. Using “Day 1” patient data, 100 ITVs were generated with 1 s interval between consecutive scan start times. Each ITV was made up by the union of 10 tumor positions obtained from 6 s scan time. Two ITV volumes were chosen for treatment planning: ITVmean-σ and ITVmean+σ. The delivered dose was computed on i) 10 phases forming the planning ITV (“10-phase” - simulating dose calculation based on 4DCT) and ii) 50 phantoms produced from 100 s of data from any other day with tumor positions sampled every 2 s (“dynamic” - simulating the dose that would actually be delivered). Results: For similar breathing patterns between “Day 1” and any other “Day N(>1)”, the 95% volume coverage (D95) for “dynamic” case was 8.13% lower than the “10-phase” case for ITVmean+σ. For breathing patterns that were very different between “Day 1” and any other “Day N(>1)”, this difference was as high as 24.5% for ITVmean-σ. Conclusion: Proton treatment planning based on pre-treatment 4DCT can lead to under-dosage of the tumor and over-dosage of the surrounding tissues, because of inadequate estimate of the range of motion of the tumor. This is due to the shift of the Bragg peak compared to photon therapy in which the tumor is surrounded by an electron bath.

60 APPLIED LIFE SCIENCES↗

SU-E-J-105: Trusting Dose Deformation and Accumulation for GYN Brachytherapy

Purpose: In brachytherapy, structures surrounding the target have the potential to move between treatments and receive unknown dose. Deformable image registration could overcome challenges through dose accumulation. This study uses two possible deformable dose summation techniques and compares the results to point dose summation currently performed in clinic. Methods: Data for ten patients treated with a Syed template was imported into the MIM software (Cleveland, OH). The deformable registration was applied to structures by masking other image data to a single intensity. The registration flow consisted of the following steps: 1) mask CTs so that each of the structures-of-interest had one unique intensity; 2) perform applicator — based rigid registration; 3) Perform deformable registration; 4) Refine registration by changing local alignments manually; 5) Repeat steps 1 to 3 until desired structure adequately deformed; 5) Transfer each deformed contours to the first CT. The deformed structure accuracy was determined by a dice similarity coefficient (DSC) comparison with the first fraction. Two dose summation techniques were investigated: a deformation and recalculation on the structure; and a dose deformation and accumulation method. Point doses were used as a comparison value. Results: The Syed deformations have DSC ranging from 0.53 to 0.97 and 0.75 and 0.95 for the bladder and rectum, respectively. For the bladder, contour deformation addition ranged from −34.8% to 0.98% and dose deformation accumulation ranged from −35% to 29.3% difference from clinical calculations. For the rectum, contour deformation addition ranged from −5.2% to 16.9% and the dose deformation accumulation ranged from −29.1% to 15.3% change. Conclusion: Deforming dose for summation leads to different volumetric doses than when dose is recalculated on deformed structures, raising concerns about the accuracy of the deformed dose. DSC alone cannot be used to establish the accuracy of a deformation for brachy dose summation purpose.

60 APPLIED LIFE SCIENCES↗

Separating Facts from Fiction: Linguistic Models to Classify Suspicious and Trusted News Posts on Twitter

Pew research polls report 62 percent of U.S. adults get news on social media (Gottfried and Shearer, 2016). In a December poll, 64 percent of U.S. adults said that “made-up news” has caused a “great deal of confusion” about the facts of current events (Barthel et al., 2016). Fabricated stories spread in social media, ranging from deliberate propaganda to hoaxes and satire, contributes to this confusion in addition to having serious effects on global stability. In this work we build predictive models to classify 130 thousand news tweets as suspicious or verified, and predict four subtypes of suspicious news – satire, hoaxes, clickbait and propaganda. We demonstrate that neural network models trained on tweet content and social network interactions outperform lexical models. Unlike previous work on deception detection, we find that adding syntax and grammar features to our models decreases performance. Incorporating linguistic features, including bias and subjectivity, improves classification results, however social interaction features are most informative for finer-grained separation between our four types of suspicious news posts.

classification↗

Trusted materials using orthogonal testing. 2015 Annual report

The purpose of this project is to prove (or disprove) that a reasonable number of simple tests can be used to provide a unique data signature for materials, changes in which could serve as a harbinger of material deviation, prompting further evaluations. The routine tests are mutually orthogonal to any currently required materials specification tests.

36 MATERIALS SCIENCE↗

TRUST-EABM Contact Thermal Conductance (CTC) Report

(U) Single Feature Testbeds to Reduce Uncertainty in Simulations and Tests [3] provided an overview for the need of experiments, with accompanying models and simulations, specifically designed to reduce uncertainties and build confidence in complex testing and analysis applications. The Contact Thermal Conductance (CTC) testbed is a joint effort between W-13 (formerly E-13) and MST-8. The objective of this study was to design a testbed, with accompanying finite element models, to quantify, reduce, and propagate measurement uncertainties in contact thermal conductance measurements between two mating components in WR-like thermal environments. The knowledge gained through this simplified experiment would educate more complex assessments and interaction conditions with WR-like materials and geometries.

42 ENGINEERING↗

Recommendations for Trust and Encryption in DER Interoperability Standards

Recently developed Distributed Energy Resource (DER) interoperability standards include communication and cyber security requirements. In 2018, the US national interconnection standard, IEEE 1547, was revised to require DER to include a Sun Spec Modbus, IEEE 2030.5 (Smart Energy Profile, SEP 2.0), or IEEE 1815 (DNP3) communication interface but does not include any normative overarching cybersecurity requirements. IEEE 2030.5 and associated implementation requirements for California, known as the California Smart Inverter Profile (CSIP), prescribe the greatest security features - including encryption, authentication, and key management requirements. Sun Spec Modbus and IEEE 1815 security requirements are not as comprehensive, leading to implementation questions throughout the industry. Further, while the security features in IEEE 2030.5 are commonly used in computing platforms, there are still questions of how well the technologies will scale in highly-distributed, computationally-limited inverter environments. In this paper, (a) the elements of IEEE 2030.5 encryption, authentication, and key management guidelines are analyzed, (b) potential scalability gaps are identified, and (c) alternative technologies are explored for possible inclusion in DER interoperability or cyber security standards.

42 ENGINEERING↗

Trust But Verify

This documentary film was made in 1989 about the methods used by each country to monitor the others weapons nuclear processes and is narrated by Charlton Heston. The DC was reviewed by Darrin Wallace (3/22/22) and confirmed unclassified to move from the red network to the yellow, but it still requires LA-UR to be assigned.

99 GENERAL AND MISCELLANEOUS↗