Search NASA⌕ Search

SEARCH · Search NASA

Results for “Time Calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Time transfer using geostationary satellites: Implementation of a Kalman filter

Since 1988, various experiments have shown that the TV signals transmitted by direct TV satellites may easily be used to perform time transfers at the level of a few tens of nanoseconds, the main source of error being the uncertainty on the satellite position. We first present the two methods used in our experiment to reduce the effects of the satellite residual motion: the first one consists in estimating the longitude variations of the satellite and then using this information to improve other measurements. This allows reducing the uncertainty to values between 9 and 50 nanoseconds according to the position of the involved stations. In the second method we determine the satellite position by using the data collected by three calibrated stations. Time transfer between each of these stations and a fourth one has been shown to be achievable at the precision level of ten nanoseconds. A new approach based on the use of a Kalman filter is proposed in order to take into account the dynamics of the geostationary satellite. The precisions on orbital elements and clock differences and rates determination given by the first simulated applications of the Kalman filter are presented and compared to those obtained by the other methods.

Meyer, F.↗

A radiation tolerant light pulser for particle physics applications

A light emitting diode (LED) pulser has been developed that can be used for tests or calibration of timing and amplitude sensitivity of particle physics detectors. Here a comparative study is performed on the components and pulser output characteristics before and after application of 800 MeV protons and cobalt-60 gammas. This device is demonstrated to be tolerant to fluences up to 6.7 x 10 13 800-MeV-p/cm 2 and gamma doses up to 5 Mrad.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NASA Tech Briefs, December 2007

Topics include: Ka-Band TWT High-Efficiency Power Combiner for High-Rate Data Transmission; Reusable, Extensible High-Level Data-Distribution Concept; Processing Satellite Imagery To Detect Waste Tire Piles; Monitoring by Use of Clusters of Sensor-Data Vectors; Circuit and Method for Communication Over DC Power Line; Switched Band-Pass Filters for Adaptive Transceivers; Noncoherent DTTLs for Symbol Synchronization; High-Voltage Power Supply With Fast Rise and Fall Times; Waveguide Calibrator for Multi-Element Probe Calibration; Four-Way Ka-Band Power Combiner; Loss-of-Control-Inhibitor Systems for Aircraft; Improved Underwater Excitation-Emission Matrix Fluorometer; Metrology Camera System Using Two-Color Interferometry; Design and Fabrication of High-Efficiency CMOS/CCD Imagers; Foam Core Shielding for Spacecraft CHEM-Based Self-Deploying Planetary Storage Tanks Sequestration of Single-Walled Carbon Nanotubes in a Polymer PPC750 Performance Monitor Application-Program-Installer Builder Using Visual Odometry to Estimate Position and Attitude Design and Data Management System Simple, Script-Based Science Processing Archive Automated Rocket Propulsion Test Management Online Remote Sensing Interface Fusing Image Data for Calculating Position of an Object Implementation of a Point Algorithm for Real-Time Convex Optimization Handling Input and Output for COAMPS Modeling and Grid Generation of Iced Airfoils Automated Identification of Nucleotide Sequences Balloon Design Software Rocket Science 101 Interactive Educational Program Creep Forming of Carbon-Reinforced Ceramic-Matrix Composites Dog-Bone Horns for Piezoelectric Ultrasonic/Sonic Actuators Benchtop Detection of Proteins Recombinant Collagenlike Proteins Remote Sensing of Parasitic Nematodes in Plants Direct Coupling From WGM Resonator Disks to Photodetectors Using Digital Radiography To Image Liquid Nitrogen in Voids Multiple-Parameter, Low-False-Alarm Fire-Detection Systems Mosaic-Detector-Based Fluorescence Spectral Imager Plasmoid Thruster for High Specific-Impulse Propulsion Analysis Method for Quantifying Vehicle Design Goals Improved Tracking of Targets by Cameras on a Mars Rover Sample Caching Subsystem Multistage Passive Cooler for Spaceborne Instruments GVIPS Models and Software Stowable Energy-Absorbing Rocker-Bogie Suspensions

Source record↗

Automated intraoperative calibration for prostate cancer brachytherapy

Purpose: Prostate cancer brachytherapy relies on an accurate spatial registration between the implant needles and the TRUS image, called ''calibration''. The authors propose a new device and a fast, automatic method to calibrate the brachytherapy system in the operating room, with instant error feedback. Methods: A device was CAD-designed and precision-engineered, which mechanically couples a calibration phantom with an exact replica of the standard brachytherapy template. From real-time TRUS images acquired from the calibration device and processed by the calibration system, the coordinate transformation between the brachytherapy template and the TRUS images was computed automatically. The system instantly generated a report of the target reconstruction accuracy based on the current calibration outcome. Results: Four types of validation tests were conducted. First, 50 independent, real-time calibration trials yielded an average of 0.57 {+-} 0.13 mm line reconstruction error (LRE) relative to ground truth. Second, the averaged LRE was 0.37 {+-} 0.25 mm relative to ground truth in tests with six different commercial TRUS scanners operating at similar imaging settings. Furthermore, testing with five different commercial stepper systems yielded an average of 0.29 {+-} 0.16 mm LRE relative to ground truth. Finally, the system achieved an average of 0.56 {+-} 0.27 mm target registration error (TRE) relative to ground truth in needle insertion tests through the template in a water tank. Conclusions: The proposed automatic, intraoperative calibration system for prostate cancer brachytherapy has achieved high accuracy, precision, and robustness.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Vacuum-Compatible Wideband White Light and Laser Combiner Source System

For the Space Interferometry Mission (SIM) Spectrum Calibration Development Unit (SCDU) testbed, wideband white light is used to simulate starlight. The white light source mount requires extremely stable pointing accuracy (<3.2 microradians). To meet this and other needs, the laser light from a single-mode fiber was combined, through a beam splitter window with special coating from broadband wavelengths, with light from multimode fiber. Both lights were coupled to a photonic crystal fiber (PCF). In many optical systems, simulating a point star with broadband spectrum with stability of microradians for white light interferometry is a challenge. In this case, the cameras use the white light interference to balance two optical paths, and to maintain close tracking. In order to coarse align the optical paths, a laser light is sent into the system to allow tracking of fringes because a narrow band laser has a great range of interference. The design requirements forced the innovators to use a new type of optical fiber, and to take a large amount of care in aligning the input sources. The testbed required better than 1% throughput, or enough output power on the lowest spectrum to be detectable by the CCD camera (6 nW at camera). The system needed to be vacuum-compatible and to have the capability for combining a visible laser light at any time for calibration purposes. The red laser is a commercially produced 635-nm laser 5-mW diode, and the white light source is a commercially produced tungsten halogen lamp that gives a broad spectrum of about 525 to 800 nm full width at half maximum (FWHM), with about 1.4 mW of power at 630 nm. A custom-made beam splitter window with special coating for broadband wavelengths is used with the white light input via a 50-mm multi-mode fiber. The large mode area PCF is an LMA-8 made by Crystal Fibre (core diameter of 8.5 mm, mode field diameter of 6 mm, and numerical aperture at 625 nm of 0.083). Any science interferometer that needs a tracking laser fringe to assist in alignment can use this system.

Azizi, Alineza↗

Resolving the Heat Generated from ZrO 2 Atomic Layer Deposition Surface Reactions

Abstract In situ pyroelectric calorimetry and spectroscopic ellipsometry were used to investigate surface reactions in atomic layer deposition (ALD) of zirconium oxide (ZrO 2 ). Calibrated and time‐resolved in situ ALD calorimetry provides new insights into the thermodynamics and kinetics of saturating surface reactions for tetrakis(dimethylamino)zirconium(IV) (TDMAZr) and water. The net ALD reaction heat ranged from 0.197 mJ cm −2 at 76 °C to 0.155 mJ cm −2 at 158 °C, corresponding to an average of 4.0 eV/Zr at all temperatures. A temperature dependence for reaction kinetics was not resolved over the range investigated. The temperature dependence of net reaction heat and distribution among metalorganic and oxygen source exposure is attributed to factors including growth rate, equilibrium surface hydroxylation, and the extent of the reaction. ZrO 2 ‐forming surface reactions were investigated computationally using DFT methods to better understand the influence of surface hydration on reaction thermodynamics.

Bielinski, Ashley R.↗

Resolving the Heat Generated from ZrO 2 Atomic Layer Deposition Surface Reactions

Abstract In situ pyroelectric calorimetry and spectroscopic ellipsometry were used to investigate surface reactions in atomic layer deposition (ALD) of zirconium oxide (ZrO 2 ). Calibrated and time‐resolved in situ ALD calorimetry provides new insights into the thermodynamics and kinetics of saturating surface reactions for tetrakis(dimethylamino)zirconium(IV) (TDMAZr) and water. The net ALD reaction heat ranged from 0.197 mJ cm −2 at 76 °C to 0.155 mJ cm −2 at 158 °C, corresponding to an average of 4.0 eV/Zr at all temperatures. A temperature dependence for reaction kinetics was not resolved over the range investigated. The temperature dependence of net reaction heat and distribution among metalorganic and oxygen source exposure is attributed to factors including growth rate, equilibrium surface hydroxylation, and the extent of the reaction. ZrO 2 ‐forming surface reactions were investigated computationally using DFT methods to better understand the influence of surface hydration on reaction thermodynamics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Charged particle reconstruction in CLAS12 using Machine Learning

In this work, we present studies of track parameter reconstruction from raw information in CLAS12 detector's Drift Chambers, using Machine Learning (ML). We study the resolution of tracks reconstructed with different types of ML models/algorithms, including Multi-Layer Perceptron (MLP), Extremely Randomized Trees (ERT) and Gradient Boosting Trees (GBT) using simulated data. We find that the resulting ML model is capable of reconstructing track parameters (particle momentum, and polar and azimuthal angles) with accuracy similar to Hit Based (HB) tracking code, but $150$ times faster. Moreover, physics reactions can be identified using the particles reconstructed by the neural network in real-time (with a rate of about $34~kHz$) during experimental data collection. The developed model can be used in numerous applications, such as triggering specific physics reactions in real-time, detector performance monitoring, and real-time detector calibration.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dynamic modeling of heat pipe integrated thermal battery latent heat storage system experiment validation

A heat pipe integrated thermal battery system has been constructed to investigate a high-temperature latent heat thermal energy storage technology that takes advantage of near isothermal operation of latent heat storage and heat pipes to potentially enable high-energy isothermal heat storage. A dynamic model constructed in Modelica has been validated, showing errors between 2.5 °C–39.7 °C across 10-h to 47-h simulations against experiment results, showing good prediction capability of experiment output, especially against phase change time. Model calibrations showing vessel heat-up capability of 3 kW and heat pipes combining to provide 600 W each during experiment operation validate experiment circumstances including reduced material loading and reduced power capability. The experiment configuration uses an Al-Mg-Zn eutectic metal as the storage material, heated via heat tape wrapped around the vessel and guide tubes to bring the system to operation range (>400 °C) and to simulate charging heat exchange, respectively, with heat rejection occurring through the surfaces of the material and facilitated via guide tubes with less insulation wrapping. The model is available in the open-source repository HYBRID on Github.

25 - ENERGY STORAGE↗

First measurement of the edge charge exchange recombination spectroscopy on EAST tokamak

An edge toroidal charge exchange recombination spectroscopy (eCXRS) diagnostic, based on a heating neutral beam injection (NBI), has been deployed recently on the Experimental Advanced Superconducting Tokamak (EAST). The eCXRS, which aims to measure the plasma ion temperature and toroidal rotation velocity in the edge region simultaneously, is a complement to the exiting core CXRS (cCXRS). Two rows with 32 fiber channels each cover a radial range from ∼2.15 m to ∼2.32 m with a high spatial resolution of ∼5-7 mm. Charge exchange emission of Carbon VI CVI at 529.059 nm induced by the NBI is routinely observed, but can be tuned to any interested wavelength in the spectral range from 400 to 700 nm. Double-slit fiber bundles increase the number of channels, the fibers viewing the same radial position are binned on the CCD detector to improve the signal-to-noise ratio, enabling shorter exposure time down to 5 ms. One channel is connected to a neon lamp, which provides the real-time wavelength calibration on a shot-to-shot basis. In this paper, an overview of the eCXRS diagnostic on EAST is presented and the first results from the 2015 experimental campaign will be shown. Good agreements in ion temperature and toroidal rotation are obtained between the eCXRS and cCXRS systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibration of a neutron time-of-flight detector with a rapid instrument response function for measurements of bulk fluid motion on OMEGA

A newly developed neutron time-of-flight (nTOF) diagnostic with a fast instrument response function has been fielded on the OMEGA laser in a highly collimated line of sight. In this study, by using a small plastic scintillator volume, the detector provides a narrow instrument response of 1.7 ns full width at half maximum while maintaining a large signal-to-noise ratio for neutron yields between 10 10 and 10 14 . The OMEGA hardware timing system is used along with an optical fiducial to provide an absolute nTOF measurement to an accuracy of ~56 ps. The fast instrument response enables the accurate measurement of the primary deuterium-tritium neutron peak shape, while the optical fiducial allows for an absolute neutron energy measurement. The new detector measures the neutron mean energy with an uncertainty of ~7 keV, corresponding to a hot-spot velocity projection uncertainty of ~12 km/s. Finally, evidence of bulk fluid motion in cryogenic targets is presented with measurements of the neutron energy spectrum.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A SEARCH FOR PULSATIONS IN SHORT GAMMA-RAY BURSTS TO CONSTRAIN THEIR PROGENITORS

We searched for periodic and quasi-periodic signals in the prompt emission of a sample of 44 bright short gamma-ray bursts (GRBs) detected with Fermi/GBM, Swift/BAT, and CGRO/BATSE. The aim was to look for the observational signature of quasi-periodic jet precession, which is expected from black hole (BH)-neutron star (NS) mergers, but not from double NS systems. Thus, this kind of search holds the key to identifying the progenitor systems of short GRBs and, in the interim before gravitational wave detectors become on-lines, represents the only direct way to constrain the progenitors. We tailored our search to the nature of the expected signal by properly stretching the observed light curves by an increasing factor with time, after calibrating the technique with synthetic curves. None of our GRBs showed evidence for periodic or quasi-periodic signals. In particular, for the seven unambiguously short GRBs with the best signal-to-noise ratios, we obtained significant upper limits to the amplitude of the possible oscillations. This result suggests that BH-NS systems do not dominate the population of short GRB progenitors, as described by the kinematic model of Stone et al.

79 ASTRONOMY AND ASTROPHYSICS↗

eHXI: A permanently installed, hard x-ray imager for the National Ignition Facility

We have designed and built a multi-pinhole imaging system for high energy x-rays (≥ 50 keV) that is permanently installed in the equatorial plane outside of the target chamber at the National Ignition Facility (NIF). It records absolutely-calibrated, time-integrated x-ray images with the same line-of-sight as the multi-channel, spatially integrating hard x-ray detector FFLEX [McDonald et al., Rev. Sci. Instrum. 75 (2004) 3753], having a side view of indirect-drive inertial confinement fusion (ICF) implosion targets. The equatorial hard x-ray imager (eHXI) has recorded images on the majority of ICF implosion experiments since May 2011. Lastly, eHXI provides valuable information on hot electron distribution in hohlraum experiments, target alignment, potential hohlraum drive asymmetries and serves as a long term reference for the FFLEX diagnostics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Large-scale calculations of 𝛽-decay rates and implications for 𝑟-process nucleosynthesis

Nuclear 𝛽 decay is a key element of the astrophysical rapid neutron capture process (𝑟 process). In this work, we present state-of-the-art global 𝛽-decay calculations based on the quantified relativistic nuclear energy density functional theory and the deformed proton-neutron quasiparticle random-phase approximation. Our analysis considers contributions from allowed and first-forbidden transitions. We used two point-coupling functionals with carefully calibrated time-odd terms and isoscalar pairing strength. The new calculations display consistent results for both employed functionals, especially near the neutron drip line, suggesting slower 𝛽 decays past the 𝑁=126 neutron shell closure than in commonly used 𝛽-decay models. The new rates, along with the existing rates based on the recent nonrelativistic global calculations, are found to slow down the synthesis of heavy elements in the 𝑟 process and significantly reduce the contribution of neutron-induced fission.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Preliminary Design of Ironless Linear Induction Motors for ITER MSE Shutter Actuators

In this article, the shutters need to be closed or opened during the operation and calibration period time for the fusion diagnostic systems, such as the International Thermonuclear Experimental Reactor (ITER) motional stark effect (MSE). Standard electric motors and actuators will not work in a strong magnetic field environment due to the presence of the magnetic field of fusion reactors. The innovative linear induction motor (LIM) with an ironless feature overcomes this kind of challenge and can be used for any application that requires controlled motion with a large stroke in the magnetic field environment. It consists of a high-electrical conductivity plate like copper and three-phase motor windings with nonferrous or stainless-steel stators. The conductor plate attached with the shutter is simply driven by the underneath three-phase linear windings to achieve linear motion. The motor drive can be controlled remotely by a controller using the electrical connection, so no sensitive electronic components are located in the harsh environment where the motor itself is located. The design requirements and test facility have been described. Several 3-D transient Maxwell electromagnetic (EM) models with different locations of three-phase linear motor windings and shutter stators have been analyzed and evolved to meet any applications allowed in the harsh environment inside the vacuum vessel of fusion reactors. The preliminary design results are presented in this article.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

H3D Characterization Memo

The H3D was characterized using GADRAS 19.3.5 using data sent by the IAEA. Everything related to the measurement setup was provided by the IAEA. The sources measured were detailed and the distance from the detector was also provided. The data sheets of the sources were used to determine the source activity at the time of calibration, as needed for characterization.

97 MATHEMATICS AND COMPUTING↗