Search NASA⌕ Search

SEARCH · Search NASA

Results for “Transfer functions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Calibration, modeling, parameterization, and verification of the instrument transfer function of an interferometric microscope

Interferometric microscopes are used to measure surface roughness, from which the computed power spectral density function can be used to extract bandwidth-limited values of the various surface properties, such as root-mean-square (rms) height and slope errors. Measurements with a microscope equipped with different objectives that have an overlapping spatial frequency range usually give different rms results over the common frequency bandwidth. This is a result of different instrument transfer functions (ITFs) that attenuate spatial frequencies by different amounts over the overlapping range. We report on the use of binary pseudo-random array (BPRA) standards to characterize the ITF of an interferometric microscope with the various objectives. We use a simple model of a 1D binary Results show that the spectrum for an undersampled array is a cosine function, rather than a straight line, constant white noise spectrum. We have an analytical model of the ITF that includes the effects of an obscured aperture and defocus, in addition to the usual parameters of numerical aperture, wavelength, and sampling period. In addition, the model includes the effect of aliasing of spatial frequency components beyond the Nyquist back into the sub-Nyquist region. We compare the model PSD predictions to the measurements performed with different objectives. Departures of the measured PSDs from the model predictions indicate that there are higher-order ITF corrections yet to be identified and included in the model.

Takacs, PZ↗

Pre-Launch Analysis and Test of the Ocean Color Instrument Modulation Transfer Function

Launched in February 2024, the Plankton, Aerosol, Cloud, and ocean Ecosystem (PACE) mission represents NASA’s next investment in ocean biology, clouds, and aerosol data records. The Ocean Color Instrument (OCI) is the primary instrument supporting PACE by collecting accurate radiometric data of the Earth by observing the top of atmosphere reflectance and is a combination hyperspectral (ultra-violet to near infrared) / multiband imager (shortwave infrared). An important aspect of the radiometry is the ability of OCI to resolve contrast from scene to scene to achieve data accuracy requirements. This paper reviews the analysis that was performed to verify the modulation transfer function requirement levied against the instrument and presents the supportive test data collected during pre-launch instrument testing to supplement the analysis. The requirements levied against OCI drove to a 1.2 km2 ground resolution leading to a Nyquist period of 2.4 km (0.417 cycles / km). The analysis is comprehensive with incorporation of as many contributors as practical to provide the clearest possible picture of the margin against requirements. The analysis provided input for additional design trade studies and insight into the aspects of the design that required the most attention during the implementation phase. We describe four separate MTF contributor networks based on the instrument design and mutual exclusivity of contributing factors. The various networks represent the hyperspectral and multiband detection systems separately as well as the along track and cross track imaging dimensions. Ground-test was performed against the MTF primary contributors and the results were used to validate the analysis as will be presented here.

OCI↗

Pre-Launch Analysis and Test of the Ocean Color Instrument Modulation Transfer Function

Launched in February 2024, the Plankton, Aerosol, Cloud, and ocean Ecosystem (PACE) mission represents NASA’s next investment in ocean biology, clouds, and aerosol data records. The Ocean Color Instrument (OCI) is the primary instrument supporting PACE by collecting accurate radiometric data of the Earth by observing the top of atmosphere reflectance and is a combination hyperspectral (ultra-violet to near infrared) / multiband imager (shortwave infrared). An important aspect of the radiometry is the ability of OCI to resolve contrast from scene to scene to achieve data accuracy requirements. This paper reviews the analysis that was performed to verify the modulation transfer function requirement levied against the instrument and presents the supportive test data collected during pre-launch instrument testing to supplement the analysis. The requirements levied against OCI drove to a 1.2 km2 ground resolution leading to a Nyquist period of 2.4 km (0.417 cycles / km). The analysis is comprehensive with incorporation of as many contributors as practical to provide the clearest possible picture of the margin against requirements. The analysis provided input for additional design trade studies and insight into the aspects of the design that required the most attention during the implementation phase. We describe four separate MTF contributor networks based on the instrument design and mutual exclusivity of contributing factors. The various networks represent the hyperspectral and multiband detection systems separately as well as the along track and cross track imaging dimensions. Ground-test was performed against the MTF primary contributors and the results were used to validate the analysis as will be presented here.

OCI↗

Measurement of the Landsat Thematic Mapper modulation transfer function using an array of point sources

This paper presents a method for measuring the Thematic Mapper (TM) imaging system point spread function (PSF) using TM imagery or a specially constructed target consisting of a two-dimensional array of approximate point sources of known dimensions and radiometric qualities. The target allows 16 separate point sources to be imaged simultaneously by the TM. The point sources were carefully placed on the ground so that their relative positions were known. Owing to sample-scene phasing, each imaged point source exhibits a different amount of blur in the digital image. The target pixels may then be recombined according to their known relative positions to form a single, sampled, nonaliased imaging system PSF. The modulation transfer function is then obtained as the modulus of the discrete Fourier transform of the PSF.

Rauchmiller, Robert F., Jr.↗

Perfect function transfer and interference effects in interacting boson lattices

We show how to perfectly transfer, without state initialization and remote collaboration, arbitrary functions in interacting boson lattices. We describe a possible implementation of state transfer through bosonic atoms trapped in optical lattices or polaritons in on-chip coupled cavities. Significantly, a family of Hamiltonians, both linear and nonlinear, is found which are related to the Bose-Hubbard model and that enable the perfect transfer of arbitrary functions. It is shown that the state transfer between two sites in two-dimensional lattices can result in quantum interference due to the different numbers of intermediate sites in different paths. The signature factor in nuclear physics can be useful to characterize this quantum interference.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Perfect function transfer in two and three dimensions without initialization

We find analytic models that can perfectly transfer, without state initialization or remote collaboration, arbitrary functions in two- and three-dimensional interacting bosonic and fermionic networks. This provides for the possible experimental implementation of state transfer through bosonic or fermionic atoms trapped in optical lattices. A significant finding is that the state of a spin qubit can be perfectly transferred through a fermionic system. Families of Hamiltonians are described that are related to the linear models and that enable the perfect transfer of arbitrary functions. Furthermore, we propose methods for eliminating certain types of errors.

36 MATERIALS SCIENCE↗

DGEN Aeropropulsion Research Turbofan (DART) Core/Combustor-Noise Infinite-Tube-Probe (ITP) Transfer Function

Direct measurements of turbofan engine core unsteady pressure is complicated by the extreme thermal environment within the engine, preventing currently available transducers from operating. It is necessary to use a remote measurement configuration such as an infinite-tube-probe (ITP) configuration in which the transducer is teed into a line pneumatically coupled with the location of interest and the other end of the ITP contains an "infinite" waveguide designed to prevent any reflections. This configuration has become a standard method for experiments concerning core noise. In order to relate the spectral pressure measurements obtained remotely with the ITP, a transfer (frequency response) function needs to be calculated based on a known pressure field. This is accomplished using a normal impedance tube at Glenn Research Center, where a flush-mounted microphone is used as a reference to the ITP signal in the calculation of the ITP's transfer function.

Boyle, Devin K.↗

Calculation of Transfer Functions of Multilayer Biotissues in the Problems of Correction of Their Fluorescence Spectra

A method for rapid calculation of a flux of stimulated fluorescence of a multilayer optically dense medium with inhomogeneous distribution of the fluorophore has been developed. The light field in the medium at the excitation wavelength of fluorescence is represented by a superposition of incident collimated, incident diffuse, and reflected diffuse fluxes. A two-stream approximation is used to describe the light field in the medium at the wavelength of emission of the fluorescence. Fluxes in adjacent elementary layers of the medium and on its surface are connected by simple matrix operators that are obtained using a combination of engineering approaches of radiation-transfer theory and single-scattering approximation. The calculations of fluorescence fluxes of a four-layer biotissue that are excited and recorded at 400–800 nm are compared with their Monte Carlo simulation with a discrepancy of 1%. The effect of the propagation medium on the fluorescence spectra of 5-ALA-induced protoporphyrin IX that are recorded from human skin was studied, and a technique for their correction that is based on measurements and quantitative analysis of the diffuse reflectance spectrum of skin was proposed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Utah FORGE Telluric Monitoring Experiment Transfer Functions

The Utah Frontier Observatory for Research in Geothermal Energy (FORGE) attempted a stimulation at well 16A(78)-32 during April and May 2022. We recorded telluric and magnetotelluric (MT) data before, during, and after the well stimulation experiment using the FORGE Telluric Monitoring (FTM) array to constrain transients in the Earth's electrical structure caused by the stimulation.

15 GEOTHERMAL ENERGY↗

Temperature compensated transfer function for probability of detection (POD) in high temperature ultrasonic NDE using low temperature signals - 249

Ultrasonic piezoelectric based transducers offer the potential for in-coolant NDT measurements and imaging required at high temperature for the safe operation of advanced small modular reactors (SMRs). Current work estimates a significant 97% reduction in the probability of detection (POD) for an artificial flaw size of 2{lambda} due to degradation of the transducer performance at elevated temperature. The source of variability for POD in the current work is the temperature dependence of material matrix of piezoelectric material PZT-5A used in the sensor. The physics based model developed using finite element method quantifies reduction in the scattering amplitude for the side drilled hole (SDH) from 15 C to 195 C. Using model assisted probability of detection (MAPOD) approach, sensor temperature effect on the POD is demonstrated for SDHs in the low carbon steel specimen. Scattering amplitudes for the room temperature simulated data is validated with the experimental data. A temperature correction factor and transfer factors are reported to transform the simulated temperature effect from physics based model to the experimental data for estimation of high temperature POD using low temperature ultrasonic measurements. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

NESC GN&C TDT Workshop on 2D Image Motion Optical Transfer Functions, Pointing Performance Analysis, and Requirements

This course was prepared by the author in support of the NASA GN&C Technical Discipline Team (TDT). The purpose of this two-day course is to inform practicing GN&C engineers, and other system and subsystem engineers, including payload engineers and mission analysts, of methodologies to analyze the pointing performance of spacecraft and to write unambiguous pointing requirements that are relevant to optical payload performance. It is hoped that the seminar will contribute to a best-practices manual and contribute to accepted and uniform means of requirements definition, validation, and verification. The course material is designed to address the needs of not only practicing GN&C engineers, but also system and subsystem engineers of other disciplines, payload engineers, mission analysts, and even astronomers who need to understand how they interface to a GN&C subsystem. Much revision is the direct result of active student participation during the presentations and from feedback obtained through course evaluation forms.

2D Image↗

High Precision Tune and Coupling Feedback and Beam Transfer Function Measurements in RHIC

Precision measurement and control of the betatron tunes and betatron coupling in the Relativistic Heavy Ion Collider (RHIC) are required for establishing and maintaining both good operating conditions and, particularly during the ramp to high beam energies, high proton beam polarization. While the proof-of-principle for simultaneous tune and coupling feedback was successfully demonstrated earlier, routine application of these systems has only become possible recently. Following numerous modifications for improved measurement resolution and feedback control, the time required to establish full-energy beams with the betatron tunes and coupling regulated by feedback was reduced from several weeks to a few hours. A summary of these improvements, select measurements benefitting from the improved resolution and a review of system performance are the subject of this report.

43 PARTICLE ACCELERATORS↗