Search NASA⌕ Search

SEARCH · Search NASA

Results for “ULTRAVIOLET FILTER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Ultraviolet Imaging Telescope (UIT) observations of galaxies

Ultraviolet images of several galaxies were obtained during the ASTRO-1 shuttle mission in December, 1990. The images have a FWHM angular resolution of approximately 3 arcsecond and are of circular fields approximately 40 arcminutes in diameter. Most galaxies were observed in at least two and sometimes as many as four broad bands. A very few fields were observed with narrower band filters. The most basic result of these observations is that most systems look dramatically different in the UV from their well-known optical appearances. Preliminary results of these studies will be presented. Information will be available on fields observed by the UTI during the ASTRO 1 mission; when that data becomes public it can be obtained from the NSSDC. The ASTRO observatory is expected to fly again in 1994 with approximately half of the observing time from that mission devoted to guest observers. The Ultraviolet Imaging telescope is extremely well suited for galaxy studies, and the UIT term is interested in encouraging a wide range of scientific studies by guest observers. Ultraviolet Imaging telescope is extremely well suited for galaxy studies, and the UIT team is interested in encouraging a wide range of scientific studies by guest observers.

Neff, S. G.↗

The ferrioxalate actinometry system of the microbial response to space environment experiment (M191)

The fluid actinometry portion of the Microbial Response to Space Environment Experiment (M191) was designed for measurement of the solar energy that penetrates certain optical filter systems during exposure in space. Potassium ferrioxalate was used to measure energy at peak wavelengths of 254, 280, and 300 nanometers because of its high degree of sensitivity and its linear response to the middle ultraviolet regions.

Parson, M.↗

Experimental limits of the extreme ultraviolet background

Photometric observations of the diffuse extreme ultraviolet background with two photometers having bandpasses of 750-940 A and 1040-1080 A are reported. The payload, which was flown aboard an ARIES sounding rocket in June 1982, is described, including the electron detectors, filters, and calibration. The operation of the probe during the experiment, including its motions, are described. The primary experiment involved spectroscopic observation of the hot white dwarf HZ43. The photometer count rate is shown and the measurements of the diffuse background are compared with theoretical predictions. Despite the lower limits obtained using a narrowband detector, the measurements are not sensitive enough to draw any relevant astrophysical conclusions.

Wulf-Mathies, C.↗

Surface reflectance measurements in the ultraviolet from an airborne platform. II

The spectral and broadband reflectance of naturally occurring desert sand, black lava, gypsum sand, and snow cover is measured from a twin engine Cessna 402-series aircraft. The measurement system is computer controlled and electrically isolated from the aircraft. It consists of upward and downward looking hemispheric diffusers, filters, a rotating 90 degree mirror, a focusing lens, and a double monochromator/PMT or a UV enhanced photodiode. Measurements are made at several altitudes enabling the empirical determination of the backscatter and attenuation effects on the reflectance. These reflectance results along with those reported earlier for a pine forest, green farmland, the open ocean, and brown farmland are represented analytically.

Doda, D. D.↗

A continuously operating source of vacuum ultraviolet below 500 angstrom

Duo plasmatron type source of ultraviolet radiation operates in the wavelength region below 500 angstrom. Since the spectra produced are determined almost completely by the gas injected, and because the source operates continuously, this arrangement is beneficial in the development and calibration of filters and detectors within discrete wavelength ranges.

Source record↗

Apparatus for photocatalytic treatment of liquids

Apparatus for decontaminating a contaminated fluid by using photocatalytic particles. The apparatus includes a reactor tank for holding a slurry of the contaminated fluid and the photocatalytic particles ultraviolet light irradiates the surface of the slurry, thereby activating the photocatalytic properties of the particles. Stirring blades for continuously agitate the irradiated fluid surface maintaining the particles in a suspended state within the fluid. A cross flow filter is used for separating the fluid from the semiconductor powder after the decomposition reaction is ended. The cross flow filter is occasionally back flushed to remove any caked semiconductor powder. The semiconductor powder may be recirculated back to the tank for reuse, or may be stored for future use. A series of reactor tanks may be used to gradually decompose a chemical in the fluid. The fluid may be pretreated to remove certain metal ions which interfere with the photocatalytic process. Such pretreatment may be accomplished by dispersing semiconductor particles within the fluid, which particles adsorb ions or photodeposit the metal as the free metal or its insoluble oxide or hydroxide, and then removing the semiconductor particles together with the adsorbed metal ions/oxides/hydroxide/free metal from the fluid.

Cooper, Gerald↗

Update on Feasibility of UV LEDs in a Spacecraft Wastewater Application

As the National Aeronautics and Space Administration (NASA) expands its scope and begins to venture into long-duration, manned space flights, the function and maintenance of spacecraft water systems becomes increasingly critical and difficult. New mission requirements limit opportunities for resupply and demand extended periods of uncrewed operations. Based on lessons learned from the International Space Station (ISS), one particular challenge of future spacecraft water systems will be maintaining adequate microbial control, especially in water subsystems and component-level elements, where effective long-duration biocontrol strategies do not currently exist. To ensure the reliability and redundancy in these systems, innovative technologies will be needed to ensure mission success. After proving feasibility of commercial-off-the-shelf (COTS) devices in flow-through applications in 2018, work focused on utilizing ultraviolet (UV) light emitting diodes (LEDs) in a wastewater tank application. This paper gives an update on the tank testing that has been performed to date. Using this technology may reduce the need for consumable resupply, such as filters or biocides, and minimize crew time to make the repairs on exhausted and/or compromised systems. The ultimate rationale behind developing a UV disinfection system is to increase the stability of water systems as requirements for sterility and microbial control become more stringent for deep space missions. The resulting data from this study will be used to narrow down possible technology demonstrations for selected ISS locations to assess the use of UV technology on future exploration-class spacecraft systems.

Susan N. Gilbert↗

Transmission and reflection studies of thin films in the vacuum ultraviolet

Both the transmittance and reflectance of 2 mm thick MgF2 substrates and of thin films of BaF2, CaF2, LaF3, MgF2, Al2O3, HfO2, and SiO2 deposited on these substrates were measured for the wavelength range 120 nm to 230 nm. Results for BaF2, LaF2 and MgF2 show promise as being good materials from which interference filters can be made. The software and related hardware needed to take large amounts of data automatically in future measurements of the transmittance and reflectance was developed.

Peterson, Lennart R.↗

Intercomparison of the Nimbus 7 SBUV/TOMS total ozone data sets with Dobson and M83 results

Two years of SBUV/TOMS (Solar Backscattered Ultraviolet/Total Ozone Mapping Spectrometer) data spanning the period November 1978 to October 1980 have been processed and compared with ground-based ozone measurements made at 62 Dobson spectrophotometer and 18 M83 filter photometer ozone stations. Results show that the satellite ozone values are consistently smaller than those measured by the stations; most of this difference is probably due to an error in the currently accepted ozone absorption cross sections at ultraviolet wavelengths. Dobson-derived ozone amounts agree extremely well with those derived from each of the satellite instruments. Long-term stability of the ozone derived by the two instruments is expected to be better than 0.5 percent per year.

Bhartia, P. K.↗

An extreme ultraviolet photometer for solar observations from the Atmosphere Explorer satellites

A broadband photometer experiment is being fabricated for the Atmosphere Explorer C, D and E missions to record the solar irradiance in the 40 to 1250 A region with seven distinct passbands. The experiment consists principally of four spinal electron multipliers located behind a moving eight position filter wheel. Six metallic filters are used to spectrally isolate the solar irradiance. In addition three Al2O3 diodes, two with filters, are being used to record the solar irradiance over the range of orbital altitudes from perigee through apogee. A principal goal of the experiment will be to measure time dependence of the solar irradiance with respect to a storage ring synchrotron light source which has been calibrated in terms of the best currently available standards of irradiance.

Heath, D. F.↗

Implementation of an impurity diagnostic suite on the Pegasus-III experiment

A suite of diagnostics used to assess impurity content and dynamics has been updated, upgraded, and installed on the Pegasus-III Experiment. Typical plasma parameters during local helicity injection start-up are τ shot ~10 ms, n e ~ 1 × 10 19 m –3 , and T e ~ 50 eV. The deployed diagnostics are compatible with this modest temperature and density regime and provide species identification, source localization, and estimation of radiation losses. Impurity species are determined by recording time-evolving, single line-of-sight spectra at 1.25 kfps using a SPRED (Survey, Poor Resolution, Extended Domain) vacuum ultraviolet spectrometer. SPRED is equipped with 450 g/mm grating, giving a spectral resolution of 0.33 nm and a spectral range from ~10 to 110 nm, useful to identify light impurity species in this temperature and density range. An absolutely calibrated spectrometer that collects light from the plasma at R tan = 15.9 cm and Δt ≥ 2 ms is used as a visible survey spectrometer and for continuum measurements. The radiated power from the plasma is estimated with a photodiode-based diagnostic. Two 16-channel absolute extreme ultraviolet diode arrays are placed behind pinhole apertures, resulting in 32 lines of sight at Z = 0, with a spatial resolution of 2–3 cm and a time response of 60 kHz. A photometrically calibrated collinear D α /near infrared filtered photodiode-based system measures the D α emission and around 1040 nm. All these instruments have been designed to suppress electromagnetic interference from megawatt-class switching power supplies.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spaceborne astronomy with electro-optical image sensors

The Space Telescope, planned for orbiting in the early 1980s, is described, with emphasis on its electro-optical image sensing capability. Relative advantages of image tubes and solid state arrays as image detectors are summarized; image tube technology is well characterized, but preference may be given to a more versatile tandem solid state array consisting of one module with high silicon response covering most of the spectrum, and a second intensified array with ultraviolet sensitivity and low noise readout. The classical 'photoelectron noise limit' calculation is reviewed, and a detailed calculation of sensitivity limits adaptable to analysis of image tube or solid state array detectors is also given. In particular, characteristics of a filter to optimize the signal to noise ratio is determined. Typical sensitivity calculations for an image tube detector show that with an exposure of one orbital night (approximately 2000 seconds), 10% photometry may be done to a low limit of visual magnitude.

Bradley, W. C.↗

Characterization of dehydration-induced luminescence of kaolinite

The dehydration-induced luminescence of a colloidal kaolinite is investigated experimentally, with particular attention given to the effect of various treatments on the luminescence characteristics. It is found that the total photon count of the emitted light is linearly related to the film thickness up to a thickness of 30 microns; mechanical stress in the form of grinding increases the photon output and produces extensive changes in the emission kinetics. A direct check of the emission wavelength dependence (by using color filters) indicates that roughly 75 percent of the emission occurs in the wavelength range below 410 nm. It is also found that incorporation of fluorescent molecules into the kaolinite paste increases the photon output and may indicate the transfer of ultraviolet photons to the fluorescent probe.

Lahav, N.↗

Measuring the Stress Factors for Photovoltaic (PV) Backsheet Degradation

Back sheet failure has resulted in power loss and large-scale recall of photovoltaic modules, resulting in billions of dollars in lost revenue. The light exposure on the backside of a photovoltaic module comes primarily from reflected light which alters the distribution of natural sunlight. Because of this, modelling the backside exposure and duplicating the exposure is much more difficult than modeling the frontside exposure. This project aims to study how various back sheets and junction box materials degrade under different conditions and to develop Python code to help model and predict degradation. The stress factors for back-sheet degradation must be quantified to extrapolate accelerated stress tests to the field. Test samples were placed in the A3, A4, and A5 conditions, as defined in IEC 62788-7-2, to assess the temperature and humidity dependence of ultraviolet (UV) induced degradation. We are utilizing a custom chamber with exposure from 0.5 UV-suns to 5 UV-suns to understand the dependence of degradation on light intensity. A group of samples put in the A3 condition had glass filters with 50% UV cut-offs of 320 nm, 335 nm, and 360 nm to assess the wavelength dependence of UV degradation. All this data is necessary to assess the impact of non-standard UV light exposure. The material evaluation tests include gloss measurements, attenuated total internal reflectance Fourier transform infrared spectroscopy (ATR-FTIR), UV-visible reflectance/transmittance utilizing a Cary Ci7000 spectrophotometer, and a nano-indenter for surface hardness and modulus measurements. Alongside the experimental work, there is a computational effort using raytracing and Python open-source tools in PVDeg , PVLib, and Bifacial_Radiance. This code will create specific exposure scenarios and enable the evaluation of chamber degradation relative to field degradation. Equation 1 is a strawman equation used to model degradation on the backside of a PV module. We will create simplified code, based on the results of ray-tracing calculations, which uses a view factor approach to provide fast calculations for the most common exposure scenarios.

14 SOLAR ENERGY↗

A spectrometer to measure the diffuse, astronomical extreme ultraviolet background

The present grazing incidence spectrometer for measuring the diffuse astronomical background between 80 and 650 A uses a wire grid collimator to define a 40-arcmin by 15-deg field of view. After passing through the collimator, radiation impinges on an array of plane reflection gratings. An array of mirrors then focuses the diffracted light through a thin filter onto a microchannel plate detector. The resulting system focuses to a few arcmin and produces spectra with 10 to 20 A resolution. Performance characteristics of the spectrometer are discussed.

Labov, Simon↗

Series-Coupled Pairs of Silica Microresonators

Series-coupled pairs of whispering-gallery-mode optical microresonators have been demonstrated as prototypes of stable, narrow-band-pass photonic filters. Characteristics that are generally considered desirable in a photonic or other narrow-band-pass filter include response as nearly flat as possible across the pass band, sharp roll-off, and high rejection of signals outside the pass band. A single microresonator exhibits a Lorentzian filter function: its peak response cannot be made flatter and its roll-off cannot be made sharper. However, as a matter of basic principle applicable to resonators in general, it is possible to (1) use multiple resonators, operating in series or parallel, to obtain a roll-off sharper, and out-of-band rejection greater, relative to those of a Lorentzian filter function and (2) to make the peak response (the response within the pass band) flatter by tuning the resonators to slightly different resonance frequencies that span the pass band. The first of the two microresonators in each series-coupled pair was a microtorus made of germania-doped silica (containing about 19 mole percent germania), which is a material used for the cores of some optical fibers. The reasons for choosing this material is that exposing it to ultraviolet light causes it to undergo a chemical change that changes its index of refraction and thereby changes the resonance frequency. Hence, this material affords the means to effect the desired slight relative detuning of the two resonators. The second microresonator in each pair was a microsphere of pure silica. The advantage of making one of the resonators a torus instead of a sphere is that its spectrum of whispering-gallery-mode resonances is sparser, as needed to obtain a frequency separation of at least 100 GHz between resonances of the filter as a whole.

Savchenkov, Anatoliy↗

Characteristics of Dynamic Activity in the Dayside Aurora

Long term global monitoring of the aurora by the Ultraviolet Imager (UVI) on the Polar spacecraft has enabled observation of auroral activity under various conditions of solar wind input. UVI is particularly suited to dayside imaging, especially in sunlit conditions during the northern hemisphere summer, owing to its solar blind narrow band filters. Several types of activity have been observed in the dayside aurora when observed on a global scale: enhancement of the auroral precipitation beginning at local noon and traveling along the flanks toward midnight observed in connection with solar wind shock fronts, regions of bright arcs traveling toward midnight that may be associated with boundary waves, and'break-up' like events in the high latitude midday region sometimes concurrent with a theta aurora. We will present several examples of dayside activity and discuss the possible mechanisms for these phenomena.

Brittnacher, M. J.↗

Antimicrobial Materials for Advanced Microbial Control in Spacecraft Water Systems

Microbial detection, identification, and control are essential for the maintenance and preservation of spacecraft water systems. Requirements set by NASA put limitations on the energy, mass, materials, noise, cost, and crew time that can be devoted to microbial control. Efforts are being made to attain real-time detection and identification of microbial contamination in microgravity environments. Research for evaluating technologies for capability enhancement on-orbit is currently focused on the use of adenosine triphosphate (ATP) analysis for detection purposes and polymerase chain reaction (peR) for microbial identification. Additional research is being conducted on how to control for microbial contamination on a continual basis. Existing microbial control methods in spacecraft utilize iodine or ionic silver biocides, physical disinfection, and point-of-use sterilization filters. Although these methods are effective, they require re-dosing due to loss of efficacy, have low human toxicity thresholds, produce poor taste, and consume valuable mass and crew time. Thus, alternative methods for microbial control are needed. This project also explores ultraviolet light-emitting diodes (UV-LEDs), surface passivation methods for maintaining residual biocide levels, and several antimicrobial materials aimed at improving current microbial control techniques, as well as addressing other materials presently under analysis and future directions to be pursued.

Birmele, Michele↗