Search NASA⌕ Search

SEARCH · Search NASA

Results for “Ultrasound imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

242 records · Page 14

Focused Assessment with Sonography for Trauma in weightlessness: a feasibility study

BACKGROUND: The Focused Assessment with Sonography for Trauma (FAST) examines for fluid in gravitationally dependent regions. There is no prior experience with this technique in weightlessness, such as on the International Space Station, where sonography is currently the only diagnostic imaging tool. STUDY DESIGN: A ground-based (1 g) porcine model for sonography was developed. We examined both the feasibility and the comparative performance of the FAST examination in parabolic flight. Sonographic detection and fluid behavior were evaluated in four animals during alternating weightlessness (0 g) and hypergravity (1.8 g) periods. During flight, boluses of fluid were incrementally introduced into the peritoneal cavity. Standardized sonographic windows were recorded. Postflight, the video recordings were divided into 169 20-second segments for subsequent interpretation by 12 blinded ultrasonography experts. Reviewers first decided whether a video segment was of sufficient diagnostic quality to analyze (determinate). Determinate segments were then analyzed as containing or not containing fluid. A probit regression model compared the probability of a positive fluid diagnosis to actual fluid levels (0 to 500 mL) under both 0-g and 1.8-g conditions. RESULTS: The in-flight sonographers found real-time scanning and interpretation technically similar to that of terrestrial conditions, as long as restraint was maintained. On blinded review, 80% of the recorded ultrasound segments were considered determinate. The best sensitivity for diagnosis in 0 g was found to be from the subhepatic space, with probability of a positive fluid diagnosis ranging from 9% (no fluid) to 51% (500 mL fluid). CONCLUSIONS: The FAST examination is technically feasible in weightlessness, and merits operational consideration for clinical contingencies in space.

NASA Discipline Life Sciences Technologies↗

In situ monitoring of microstructure evolution during thermal processing of uranium-zirconium alloys using laser-generated ultrasound

In this study, laser-generated ultrasound was used to monitor microstructure evolution during thermal processing of as-cast, polycrystalline binary uranium-zirconium metallic fuel alloys with compositions of U-20wt.%Zr (U-20Zr), U-50wt.%Zr (U-50Zr) and U-80wt.%Zr (U-80Zr). Ultrasonic waveforms were recorded during heating and cooling the samples from room temperature to >973 K and back. A phase transition temperature for all three compositions was estimated from the temperature at which an abrupt and rapid reduction in ultrasonic velocities was observed. Microstructural features on the length scale of tens of micrometers were inferred from the observation of scattering of ultrasonic waves by elastic heterogeneities above ~823 K in U-20Zr, while a hysteresis in the ultrasonic velocities of U-80Zr upon cooling was attributed to a partial retention of the high temperature phase following thermal annealing. The U-50Zr alloy exhibited a reversible viscoelastic response above 933 K, as evidenced by the observation of high frequency attenuation of the shear component of the waveforms at high temperature. Ultrasonic measurements were supplemented by in situ transmission electron microscopy (TEM). The TEM images revealed that the δ-U-Zr matrix in the three compositions underwent a spinodal decomposition above ~823 K into nanoscale regions. The ultrasonic measurements revealed larger, micron-scale structure evolution in the U-20Zr alloy at the same temperature. This large-scale structure is associated with heterogeneous regions having different Zr content. Our findings show the potential heating rate dependence of microstructural evolution in U-Zr alloys and highlight differences in the thermomechanical response and associated length scales during thermal annealing between single- and dual-phase compositions. These results demonstrate the utility of laser ultrasonics to rapidly and efficiently scan phase boundaries and monitor micrometer-scale structure evolution in metallic fuel alloys.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Quantitative 3-D imaging topogrammetry for telemedicine applications

The technology to reliably transmit high-resolution visual imagery over short to medium distances in real time has led to the serious considerations of the use of telemedicine, telepresence, and telerobotics in the delivery of health care. These concepts may involve, and evolve toward: consultation from remote expert teaching centers; diagnosis; triage; real-time remote advice to the surgeon; and real-time remote surgical instrument manipulation (telerobotics with virtual reality). Further extrapolation leads to teledesign and telereplication of spare surgical parts through quantitative teleimaging of 3-D surfaces tied to CAD/CAM devices and an artificially intelligent archival data base of 'normal' shapes. The ability to generate 'topogrames' or 3-D surface numerical tables of coordinate values capable of creating computer-generated virtual holographic-like displays, machine part replication, and statistical diagnostic shape assessment is critical to the progression of telemedicine. Any virtual reality simulation will remain in 'video-game' realm until realistic dimensional and spatial relational inputs from real measurements in vivo during surgeries are added to an ever-growing statistical data archive. The challenges of managing and interpreting this 3-D data base, which would include radiographic and surface quantitative data, are considerable. As technology drives toward dynamic and continuous 3-D surface measurements, presenting millions of X, Y, Z data points per second of flexing, stretching, moving human organs, the knowledge base and interpretive capabilities of 'brilliant robots' to work as a surgeon's tireless assistants becomes imaginable. The brilliant robot would 'see' what the surgeon sees--and more, for the robot could quantify its 3-D sensing and would 'see' in a wider spectral range than humans, and could zoom its 'eyes' from the macro world to long-distance microscopy. Unerring robot hands could rapidly perform machine-aided suturing with precision micro-sewing machines, splice neural connections with laser welds, micro-bore through constricted vessels, and computer combine ultrasound, microradiography, and 3-D mini-borescopes to quickly assess and trace vascular problems in situ. The spatial relationships between organs, robotic arms, and end-effector diagnostic, manipulative, and surgical instruments would be constantly monitored by the robot 'brain' using inputs from its multiple 3-D quantitative 'eyes' remote sensing, as well as by contact and proximity force measuring devices. Methods to create accurate and quantitative 3-D topograms at continuous video data rates are described.

Altschuler, Bruce R.↗

Harnessing Artificial Intelligence for Medical Diagnosis and Treatment During Space Exploration Missions

From May 8th to June 9th, 2023, I had the opportunity to participate in an experiential learning experience at Johnson Space Center in Houston, TX with Exploration Medical Capability (ExMC), an element of the NASA Human Research Program. During this research experience, I was not only able to work on the above titled research project, but also gain an immense exposure to the field of aerospace medicine, make numerous connections within the field, tour NASA facilities, as well as travel to the Aerospace Medical Association Annual Conference (AsMA) in New Orleans. To briefly introduce my project, it is well understood that the medical capabilities available to crew medical officers (CMOs) on the International Space Station will be different than the capabilities available and needed during deep space exploration missions to the Moon, Mars, and beyond. Ground support is particularly limited due to distance, communication delays (or lack of communication), and lack of resupply. Therefore, to support medical care by CMOs on these missions, robust clinical decision support systems (CDSSs) must be designed. The recent publication and public launch of generative artificial intelligence (AI) tools based upon large language models (LLM) such as ChatGPT provides the opportunity to create a smart assistant for onboard triage, diagnosis, and treatment of medical conditions. Ultimately, the overall purpose of the project was to research what AI tools currently exist or are in development, and to see how they might be implemented onboard during exploration class spaceflights of the future. The ExMC element is actively developing several tools to be used in preparation for and during deep space exploration missions. One of those tools, known as IMPACT, is a probabilistic risk assessment model which can be used to propose a desired medical system (based on mass and volume) and suggest the clinical outcomes likely to occur for a design reference mission (DRM). The group recently presented the IMPACT model and a DRM of interest titled “Modified Long Duration Lunar Orbital and Lunar Surface” (mLDLOLS) at the recent AsMA conference. The mLDLOLS mock mission is a 9 month and 6-day deep space exploration mission consisting of time in Moon’s orbit (3 months on the Gateway space station), on the lunar surface (3 months within habitat), and another 3 months on Gateway before return to Earth. For this DRM, IMPACT ultimately outlined a preferred medical system that was then associated with medical conditions considered to be most likely based on frequency, most likely to cause astronaut task time loss (TTL), most likely to cause return to definitive care (RTDC), and most likely cause loss of crew life (LOCL). IMPACT also highlighted the medical capabilities/skills that would be required to care for those medical conditions, such as performing a history of present illness or musculoskeletal exam with ultrasound. The primary objective of the project was to perform a survey of the AI tools and systems applicable to the conditions outlined for the proposed mLDLOLS mission. Using PubMed (including most relevant MeSH terms) and Google Scholar, we then created a robust annotated bibliography organized by condition. The 56-page and over 500 reference annotated bibliography was subsequently used to create a review outline that would become the basis for drafting of a future publication. For the review outline, we took those medical conditions researched within the annotated bibliography (condition-based approach) and deployed a systems-based approach, combining those medical conditions and related tools into ten categories. These categories included general/all-purpose CDSSs, tools to diagnose or manage respiratory, dermatologic, neurologic, auditory and vestibular, ophthalmic, musculoskeletal, infection-associated, and gynecologic conditions, as well as tools that could be deployed in the setting of trauma/emergency. With the completion of the 30-page outline, we then began drafting the review paper. To conclude the research experience, I presented the findings from our survey to the ExMC Clinical and Science team. With these objectives, I ultimately learned about the number of AI tools that exist today to assist medical professionals with the triage, diagnosis, and management of several medical conditions. These tools can span from chatbot assistants to help triage knee pain to vision transformer models that can identify ophthalmic conditions based on ocular surface images captured with a cell phone. We also highlighted the current gaps that exist in the literature alongside the advancements that are needed to make the desired CDSS for deep space exploration missions. With this experience, I certainly confirmed an existing career goal and identified several additional skills needed to become an aerospace medical doctor including knowledge of critical care in an extreme medicine setting, aerospace engineering and human integration systems, artificial intelligence, machine learning, and risk models. I also identified numerous transferable skills for this career goal including the basic knowledge of medicine (MD), deployment of the scientific method for critical thought about new scientific questions (PhD), review of published literature, including creating an annotated bibliography (PhD), as well as detailed scientific writing (PhD). The results of my research will likely guide the design of an all-encompassing onboard medical assistant for use during deep space exploration missions of the future. I plan on sharing the outcomes from this experience with my peers at a student seminar in the Fall semester on August 30th. During the seminar, I will detail the project, my experience at NASA and AsMA, as well as offer best practice guidelines for students entertaining similar experiences or careers. In conclusion, I would like to thank the WVU School of Medicine, Research and Graduate Education office, as well as NASA ExMC for the unwavering support of this life-changing experience.

Ryan A. Lacinski↗

Custom Integration of Multiple Medical Functionalities

INTRODUCTION: Previous spaceflight experience and results from probabilistic risk assessment of spaceflight medical risk have highlighted the need for vital sign measurements, medical scopes, and clinical imaging tools for managing medical conditions during spaceflight. The Human Research Program’s Exploration Medical Capability (ExMC) Element and the Mars Campaign Office’s Exploration Medical Integrated Product Team (XMIPT) have performed ground-based evaluations of two Commercial-off-the-Shelf (COTS) Multi-functional Integrated Medical (MIM) devices, which integrate various medical capabilities together in one device. The key findings from these evaluations are presented in a complementary presentation, leaving this presentation to focus on forward recommendations for customized integration of multiple medical functionalities. KEY COMPONENTS: The key features of a custom integration of multiple medical functionalities includes devices and capabilities that optimally reduce medical risk. The COTS MIM devices incorporated functionality for best supporting Earth-based, emergency, pre-hospital care. Our custom integration will use probabilistic risk assessment tools, such as the Medical Extensible Dynamic Probabilistic Risk Assessment Tool (MEDPRAT), to determine the optimal functionality to include based on medical risk minimization. An additional feature of custom integration includes the ability to adapt to different requirements within different vehicles and/or missions. The COTS MIM devices store data in patient specific records, however, the format of the records is not modifiable, and data are not easily transferred from the MIM device to a central data architecture outside of the manufacturer’s established system. Our concept for custom integration will use devices that have an open application programming interface, which can easily connect to independent data architectures and third-party visualization software. The ultrasound capabilities included within the COTS MIM devices did not satisfy many of the Artemis Research and Operations Working Group’s ultrasound functional needs, and therefore, incorporation of higher quality ultrasound capabilities within a customized integration will be beneficial. The COTS MIM devices included minimal procedural guidance and clinical decision support tools. Supplemental tools of this type would need to be supplied along with the COTS MIM devices if they were to be used operationally, so another advantage of customization is the ability to integrate these support tools along with the medical functionality, for a more streamlined user experience. CONCLUSION: Investigation of a customized integration of medical functionality provides a method for further understanding the needs of a long-term exploration spaceflight medical system. The crew members of these exploration missions will need to operate more and more independently from Earth-based ground support. Therefore, having an optimized, streamlined medical system, which contains the functionality and supporting information needed, while remaining within mission and vehicle constraints, will help to maintain crew health and performance, which is necessary for achieving high levels of mission success.

B E Lewandowski↗

Nondestructive Modular Leak Detection in 3D Printed 316L Stainless Steel Pipes via Laser Powder Bed Fusion

This research investigates the leak detection features of 316L Stainless Steel pipe structures manufactured via Laser Powder Bed Fusion (LPBF). This work involves the design of a modular sensor system integrating nondestructive evaluation (NDE) methods, including thermal imaging and ultrasonic frequency detection to detect and characterize leaks in components. This aims to improve leak detection sensitivity within medium-pressure gas systems, during continuous operation without halting flow or introducing safety risks. The system could be adaptable for use on unmanned aerial vehicles (UAVs), enabling remote leak detection in active environments. A custom pneumatic system incorporating temperature and pressure sensors was assembled to detect leaks in LPBF-printed 316L SS tee pipes. Experimental results and simulations confirm the system’s effectiveness in leak detection and material evaluation. This research program also integrated a Python-based image recognition platform based on a metallography and optical microscopy to assess the porosity and complement the leak detection data on the printed structures. This allows a detailed analysis of pore distribution and internal leak paths, which could compromise structural integrity, critical for quality control during manufacturing. Findings suggest that the investigated approach holds potential for enhancing leak detection technologies and adapt them for advanced manufactured parts.

36 MATERIALS SCIENCE↗

A Computational Framework to design 3D stiffness gradient acoustic metamaterials for impedance matching

Acoustic waves play a crucial role in various applications, including medical imaging, non-destructive testing, and sonar systems. One of the significant challenges in these applications is impedance matching, which is essential for minimizing reflections and maximizing the transfer of acoustic energy between different media. Acoustic metamaterials offer a promising solution to this challenge. In addition to impedance control, gradient stiffness can enhance structural efficiency and enable spatial control of wave propagation, making it a valuable feature in acoustic metamaterial design. In this pa- per, we present our developed computational method to design 3D stiffness gradient acoustic metamaterials for impedance matching. The key steps in our approach include generating initial designs using a periodic covariance function to provide unit cells that are both periodic on the boundaries and randomly formed inside the unit cell. Furthermore, we integrated manufacturing constraints into the design process, ensuring that the structures are interconnected for fabrication. We propose two computational optimization algorithms: GenUnit, based on a non-dominated sorting genetic algorithm (NSGA-II), and MLMatch, which leverages differentiable machine learning. The two approaches are not separate contributions but complementary com- ponents of a unified framework. GenUnit requires no training data and directly interfaces with physics-based simulations, making it highly accurate but slower for large-scale exploration. In contrast, MLMatch is data-hungry during training but, once trained, enables near-instantaneous inference and broad design-space coverage. Together, they form a hybrid strategy: ML- Match rapidly explores the global design space, and GenUnit provides local refinement with high-fidelity accuracy. This balance between training cost, inference time, and precision is the motivation for including both methods in the same study. We applied this dual-algorithm framework to generate two metallic-based metamaterial designs that match the acoustic impedance of water while exhibiting a controlled gradient in stiffness (from stiff to soft). The stiffness gradient is particularly advantageous in applications where one side of the structure must interface with soft or sensitive surfaces, such as human tissue or delicate components. Here, this work paves the way for improved materials in various acoustic applications, particularly in ultrasound devices, by providing better impedance.

Metamaterial↗

Species-specific acoustic responses by bats to ultrasonic stimuli used for reducing bat-wind turbine interactions

An unintended consequence of wind energy generation is bat fatalities caused by wind turbine blade strikes. One potential approach to reduce collision risk is to use ultrasound to create an uncomfortable or disorienting airspace around wind turbine blades. Ultrasonic deterrents (UDs) have produced mixed results in experimental field studies at commercial wind energy facilities, with effectiveness varying by species and location. It is possible that some species can alter their normal echolocation characteristics to counter the signal of UDs. Our broad objective was to maximize the effectiveness of a UD by comparing changes in echolocation characteristics during three UD frequency emissions among species, between seasons, and between sex. We hypothesized that UD emissions with frequencies most similar to each species’ echolocation characteristics would be more likely to alter the bats’ echolocation, and bat responses would vary between seasons and sex for each species. We released wild-captured bats into a 60 m × 10 m × 4.4 m (length × width × height) flight cage located in San Marcos, Texas, USA, from July to October 2020 and March to May 2021 and monitored echolocation frequencies with ultrasonic microphones. We conducted trials on Brazilian free-tailed bats ( Tadarida brasiliensis ; n = 54), cave myotis ( Myotis velifer ; n = 44), red bats ( Lasiurus blossevilli , Lasiurus borealis ; n = 41), evening bats ( Nycticeius humeralis ; n = 32), and tricolored bats ( Perimyotis subflavus ; n = 8). We found that species with high-frequency echolocation calls altered their echolocation signatures more commonly during high-frequency UD emissions, whereas low-frequency bats altered their echolocation signatures more commonly during low-frequency UD emissions. Additionally, echolocation responses varied between seasons and sexes for several species. Variations in responses may be dependent on species migratory status, differences in mating behavior and mating season, hormonal differences between sexes and seasons, and/or constraints on echolocation adaptability. Our results offer insights into the variable effectiveness of UDs at reducing bat fatalities at wind turbines and provide information for potential adjustments to UDs for improved success.

17 WIND ENERGY↗