Search NASA⌕ Search

SEARCH · Search NASA

Results for “Ultraviolet lasers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Ultraviolet /UV/ sensitive phosphors for silicon imaging detectors

The fluorescence properties of UV sensitive organic phosphors and the radiometric properties of phosphor coated silicon detectors in the VUV, UV, and visible wavelengths are described. With evaporated films of coronene and liumogen, effective quantum efficiencies of up to 20% have been achieved on silicon photodiodes in the vacuum UV. With thin films of methylmethacrylate (acrylic), which are doped with organic laser dyes and deposited from solution, detector quantum efficiencies of the order of 15% for wavelengths of 120-165 nm and of 40% for wavelengths above 190 nm have been obtained. The phosphor coatings also act as antireflection coatings and thereby enhance the response of coated devices throughout the visible and near IR.

Viehmann, W.↗

Director's Discretionary Fund Report for Fiscal Year 1996

Topics covered include: Waterproofing the Space Shuttle tiles, thermal protection system for Reusable Launch Vehicles, computer modeling of the thermal conductivity of cometary ice, effects of ozone depletion and ultraviolet radiation on plants, a novel telemetric biosensor to monitor blood pH on-line, ion mobility in polymer electrolytes for lithium-polymer batteries, a microwave-pumped far infrared photoconductor, and a new method for measuring cloud liquid vapor using near infrared remote sensing. Also included: laser-spectroscopic instrument for turbulence measurement, remote sensing of aircraft contrails using a field portable imaging interferometer, development of a silicon-micromachined gas chromatography system for determination of planetary surface composition, planar Doppler velocimetry, chaos in interstellar chemistry, and a limited pressure cycle engine for high-speed output.

Source record↗

JPL Fourier transform ultraviolet spectrometer

The Fourier Transform Ultraviolet Spectrometer (FTUVS) is a new high resolution interferometric spectrometer for multiple-species detection in the UV, visible and near-IR. As an OH sensor, measurements can be carried out by remote sensing (limb emission and column absorption), or in-situ sensing (long-path absorption or laser-induced fluorescence). As a high resolution detector in a high repetition rate (greater than 10 kHz) LIF system, OH fluorescence can be discriminated against non-resonant background emission and laser scatter, permitting (0, 0) excitation.

Cageao, R. P.↗

Program Annual Technology Report: Physics of the Cosmos Program Office

From ancient times, humans have looked up at the night sky and wondered: Are we alone? How did the universe come to be? How does the universe work? PCOS focuses on that last question. Scientists investigating this broad theme use the universe as their laboratory, investigating its fundamental laws and properties. They test Einstein’s General Theory of Relativity to see if our current understanding of space-time is borne out by observations. They examine the behavior of the most extreme environments – supermassive black holes, active galactic nuclei, and others – and the farthest reaches of the universe, to expand our understanding. With instruments sensitive across the spectrum, from radio, through infrared (IR), visible light, ultraviolet (UV), to X rays and gamma rays, as well as gravitational waves (GWs), they peer across billions of light-years, observing echoes of events that occurred instants after the Big Bang. Last year, the LISA Pathfinder (LPF) mission exceeded expectations in proving the maturity of technologies needed for the Laser Interferometer Space Antenna (LISA) mission, and the Laser Interferometer Gravitational-Wave Observatory (LIGO) recorded the first direct measurements of long-theorized GWs. Another surprising recent discovery is that the universe is expanding at an ever-accelerating rate, the first hint of so-called “dark energy,” estimated to account for 75% of mass-energy in the universe. Dark matter, so called because we can only observe its effects on regular matter, is thought to account for another20%, leaving only 5% for regular matter and energy. Scientists now also search for special polarization in the cosmic microwave background to support the notion that in the split-second after the Big Bang, the universe inflated faster than the speed of light! The most exciting aspect of this grand enterprise today is the extraordinary rate at which we can harness technologies to enable these key discoveries.

COR↗

Initial On-Orbit Spectral Calibration of the PACE Ocean Color Instrument

The NASA Plankton, Aerosol, Cloud, and ocean Ecosystem (PACE) mission Project Science Team has used Ocean Color Instrument (OCI) measurements of Fraunhofer lines in spectra of sunlight reflected by the solar diffuser and measurements of atmospheric absorption bands in cloudtop and ocean spectra to characterize the spectral calibration of OCI on orbit. Multiple lines have been analyzed for both the ultraviolet to visible (UVVIS, 340−607 nm) and visible to near-infrared (VISNIR, 597−897 nm) grating spectrographs. The spectrographs yield hyperspectral observations with 5 nm bandwidths and 0.625 nm sampling intervals. The on-orbit observations have been compared with the prelaunch spectral calibration of OCI performed by the Goddard Laser for Absolute Measurement of Radiance (GLAMR) during thermal vacuum testing to track any changes in the calibration since launch. The calibration analyzed the line positions and strengths for the Fraunhofer lines for each spectrograph by comparing the solar spectra measured by OCI with predicted solar spectra derived from the solar reference spectrum and the BRDF of the solar diffuser, convolved with the OCI relative spectral responses. The calibration also compared the line positions of the atmospheric absorption bands with the model transmissions used by the PACE Project. The line position comparisons show that the root mean square (RMS) spectral difference between the measured and predicted spectra is 0.15 nm, the average spectral shift is 0.062 nm, and the residual spectral dispersion over the wavelength range of the Fraunhofer lines is 0.17 nm. All three estimates of the spectral accuracy of OCI meet the instrument functional requirement of a spectral accuracy of 0.5 nm and are well within the 0.625 nm sampling interval of the data. The line strength comparisons between measured and predicted spectra are essentially the same. These results show that the spectral calibration of OCI on orbit has not drifted since the prelaunch calibration of OCI by GLAMR and that the on-orbit spectral calibration of OCI is stable over time. These results also provide a baseline for monitoring the future spectral performance of OCI on orbit.

Radiometric Calibration↗

Line Profile Measurements of Atomic Oxygen at 1300 A with a VUV Raman Shifter

We are currently developing an atomic oxygen diagnostic to study the degree of oxygen dissociation in ground-based facilities. The absorption of the (sub 3)P - (sup 3)S(sup 0) resonance triplet in the vacuum ultraviolet is a direct measure of the ground state number density of atomic oxygen. Although the integrated line strength is well known for these transitions, the line profile is not. We report the results of a series of experiments in which the line profile is measured in shock-heated oxygen. An ArF excimer laser and a hydrogen Raman shifter generate tunable VUV radiation at the resonance wavelength. The test gas is dissociated oxygen, generated in the Electric Arc Shock Tube (EAST) Facility at NASA-Ames Research Center. By measuring the absorption of known concentrations of atomic oxygen, we are able to study the absorption line profile. The results will serve as a calibration to apply this diagnostic in other flowfields.

Sharma, Surendra P.↗

UV lidar measurements of the stratospheric aerosol layer and comparison with other optical data

After the violent volcanic eruptions of El Chichon in Mexico (17.33 deg. N, 93.20 deg. W) in late March and early April 1982, enhanced stratospheric aerosols have been monitored by ruby (lasing wavelength lambda=694.3 nm) or Nd:YAG lidars (lambda=1064 or 532 nm). By these lidars, visible or near-infrared optical informations of stratospheric aerosols and their space-time variations can be obtained. It is usually difficult to measure the background level of stratospheric aerosols by an ultraviolet (UV) lidar, since Rayleigh scattering prevails over Mie scattering in the stratosphere. However, after the large volcanic eruptions, UV lidar measurements of stratospheric aerosols are possible. In order to obtain UV optical properties of stratospheric aerosols, measurements have been made at Fukuoka (33.65 deg. N, 130.35 deg. E) by a p-terphenyl dye laser at a wavelength of 340.5 nm. Observational results during October 1982, through May 1983, are shown and are compared with the results obtained by a ruby lidar at Tsukuba (36.05 deg. N, 140.13 deg. E).

Uchino, O.↗

5' modification of duplex DNA with a ruthenium electron donor-acceptor pair using solid-phase DNA synthesis

Incorporation of metalated nucleosides into DNA through covalent modification is crucial to measurement of thermal electron-transfer rates and the dependence of these rates with structure, distance, and position. Here, we report the first synthesis of an electron donor-acceptor pair of 5' metallonucleosides and their subsequent incorporation into oligonucleotides using solid-phase DNA synthesis techniques. Large-scale syntheses of metal-containing oligonucleotides are achieved using 5' modified phosporamidites containing [Ru(acac)(2)(IMPy)](2+) (acac is acetylacetonato; IMPy is 2'-iminomethylpyridyl-2'-deoxyuridine) (3) and [Ru(bpy)(2)(IMPy)](2+) (bpy is 2,2'-bipyridine; IMPy is 2'-iminomethylpyridyl-2'-deoxyuridine) (4). Duplexes formed with the metal-containing oligonucleotides exhibit thermal stability comparable to the corresponding unmetalated duplexes (T(m) of modified duplex = 49 degrees C vs T(m) of unmodified duplex = 47 degrees C). Electrochemical (3, E(1/2) = -0.04 V vs NHE; 4, E(1/2) = 1.12 V vs NHE), absorption (3, lambda(max) = 568, 369 nm; 4, lambda(max) = 480 nm), and emission (4, lambda(max) = 720 nm, tau = 55 ns, Phi = 1.2 x 10(-)(4)) data for the ruthenium-modified nucleosides and oligonucleotides indicate that incorporation into an oligonucleotide does not perturb the electronic properties of the ruthenium complex or the DNA significantly. In addition, the absence of any change in the emission properties upon metalated duplex formation suggests that the [Ru(bpy)(2)(IMPy)](2+)[Ru(acac)(2)(IMPy)](2+) pair will provide a valuable probe for DNA-mediated electron-transfer studies.

Non-NASA Center↗

The fluorescence of chlorophyll and yellow substances in natural waters: A note on the problems of measurement and the importance of their remote sensing

There are two chromophylls which, if sensed remotely from high altitude, would revolutionize the ability to survey large areas of the world's oceans. The chromophylls of importance are: the photosynthetic pigments of plankton algae and a group of organic materials frequently termed dissolved yellow substances. These are derived from plants and carried into the ocean by fresh water inflow. The attenuation of light by phytoplankton is characterized by two distinctive bands (450, 675 nm) which represent absorption by chloroplastic pigments. Yellow substances are characterized by a strong ultraviolet absorption which tails over into the visible region. It is emphasized that chlorophyll determination could be a unique technique for estimating the extent of eutrophication in coastal waters, and that a high altitude observer equipped with temperature, chlorophyll and yellow substance sensors has the possibility of detecting the magnitude of eutrophication and its sources by using laser induced fluorescent devices.

Yentsch, C. S.↗

Soft Real-Time PID Control on a VME Computer

microPID (uPID) is a computer program for real-time proportional + integral + derivative (PID) control of a translation stage in a Fourier-transform ultraviolet spectrometer. microPID implements a PID control loop over a position profile at sampling rate of 8 kHz (sampling period 125microseconds). The software runs in a strippeddown Linux operating system on a VersaModule Eurocard (VME) computer operating in real-time priority queue using an embedded controller, a 16-bit digital-to-analog converter (D/A) board, and a laser-positioning board (LPB). microPID consists of three main parts: (1) VME device-driver routines, (2) software that administers a custom protocol for serial communication with a control computer, and (3) a loop section that obtains the current position from an LPB-driver routine, calculates the ideal position from the profile, and calculates a new voltage command by use of an embedded PID routine all within each sampling period. The voltage command is sent to the D/A board to control the stage. microPID uses special kernel headers to obtain microsecond timing resolution. Inasmuch as microPID implements a single-threaded process and all other processes are disabled, the Linux operating system acts as a soft real-time system.

Karayan, Vahag↗

Health Sensing Functions in Thermal Barrier Coatings Incorporating Rare-Earth-Doped Luminescent Sublayers

Great effort has been directed towards developing techniques to monitor the health of thermal barrier coatings (TBCs) that would detect the approach of safety-threatening conditions. An unconventional approach is presented here where health sensing functionality is integrated into the TBC itself by the incorporation of rare-earth-doped luminescent sublayers to monitor erosion as well as whether the TBC is maintaining the underlying substrate at a sufficiently low temperature. Erosion indication is demonstrated in electron-beam physical vapor deposited (EB-PVD) TBCs consisting of 7wt% yttria-stabilized zirconia (7YSZ) with europium-doped and terbium-doped sublayers. Multiple ingot deposition produced sharp boundaries between the doped sublayers without interrupting the columnar growth of the TBC. The TBC-coated specimens were subjected to alumina particle jet erosion, and the erosion depth was then indicated under ultraviolet illumination that excited easily visible luminescence characteristic of sublayer that was exposed by erosion. In addition, temperature measurements from a bottom-lying europium-doped sublayer in a TBC produced by multiple ingot EB-PVD were accomplished by measuring the temperature-dependent decay time from the 606 nm wavelength emission excited in that sublayer with a 532 nm wavelength laser that was selected for its close match to one of the europium excitation wavelengths as well as being at a wavelength where the TBC is relatively transparent. It is proposed the low dopant levels and absence of interruption of the TBC columnar growth allow the addition of the erosion and temperature sensing functions with minimal effects on TBC performance.

Eldridge, J. I.↗

Mars Immunoassay Life Detection Instrument (MILDI)

The direct detection of organic biomarkers for living or fossil microbes on Mars by an in situ instrument is a worthy goal for future lander missions. We have proposed an instrument based on immunological reactions to specific antibodies to cause activation of fluorescent stains. Antibodies are raised or acquired to a variety of general and specific substances that might be in Mars soil. These antibodies are then combined with various fluorescent stains and applied to small numbered spots on a small (two to three centimeters) test plate where they become firmly attached after drying. On Mars, a sample of soil from a trench or drill core is extracted with water and/or an organic solvent that is then applied to the test plate. Any substance, which has an antibody on the test plate, will react with its antibody and activate its fluorescent stain. A small ultraviolet light source will illuminate the test plate, which is observed with a small CCD camera. The numbered spots that fluoresce indicate the presence of the tested-for substance, and the intensity indicates relative amounts. The entire instrument can be quite small and light, on the order of ten cm in each dimension. A possible choice for light source may be small UV lasers at several wavelengths. Up to 1000 different sample spots can be placed on a plate 3 cm on a side, but a more practical number might be 100. Each antibody can have a redundant position for independent verification of reaction. Some of the wells or spots can contain simply standard fluorescent stains used to detect live cells, dead cells, DNA, etc. These the stains in these spots may be directly activated; no antibodies are necessary.

McKay, David↗

The Production of Complex Organics from Interstellar Ices

Infrared spectroscopy of ices in interstellar dense molecular clouds has shown that they contain a variety of simple molecules, as well as aromatic hydrocarbons. While in these clouds, these ices are processed by ultraviolet light and cosmic rays. High vacuum, UV irradiation laboratory simulations conducted using various realistic approx. 10 K interstellar mixed-molecular ice analogs, both with and without polycyclic aromatic hydrocarbons (PAHs), have been carried out in NASA-Ames' Astrochemistry Laboratory. Upon warming, these irradiated ices are found to produce refractory organic residues. These residues have been analyzed using a variety of techniques, including HPLC and laser desorption mass spectrometry, and they have been shown to contain a variety of complex organic compounds. Several of these compounds may be of prebiotic significance. In particular, we will discuss the detection of quinones (substituted PAHs that are used by living systems for electron transport) and amphiphiles (molecules that self-assemble to form membranes). Laboratory simulations have also demonstrated that the organic products can show isotopic enrichments in D that provide clues for the mechanisms of their formation. Similar compounds and D enrichments are seen in the organics found in primitive meteorites, suggesting a direct link between interstellar chemistry and the delivery of organics to newly formed planets.

Sandford, Scott A.↗

Look Sharp While Seeing Sharp

The two scientists James B. Stephens and Dr. Charles G. Miller were tasked with studying the harmful properties of light in space, as well as the artificial radiation produced during laser and welding work, for the purpose of creating an enhanced means of eye protection in industrial welding applications. While working to apply their space research to these terrestrial applications, Stephens and Miller became engrossed with previously discovered research showing evidence that the eyes of hawks, eagles, and other birds of prey contain unique oil droplets that actually protect them from intensely radiated light rays (blue, violet, ultraviolet) while allowing vision-enhancing light rays (red, orange, green) to pass through. These oil droplets absorb short wavelength light rays which, in turn, reduce glare and provide heightened color contrast and definition for optimal visual acuity. Accordingly, birds of prey possess the ability to distinguish their targeted prey in natural surroundings and from great distances. Pairing the findings from their initial studies with what they learned from the bird studies, the scientists devised a methodology to incorporate the light-filtering/vision-enhancing dual-action benefits into a filtering system, using light-filtering dyes and tiny particles of zinc oxide. (Zinc oxide, which absorbs ultraviolet light, is also found in sunscreen lotions that protect the skin from sunburn.)

Source record↗

Laboratory Studies of Thermal Energy Charge Transfer of Multiply Charged Ions in Astrophysical Plasmas

The laser ablation/ion storage facility at the UNLV Physics Department has been dedicated to the study of atomic and molecular processes in low temperature plasmas. Our program focuses on the charge transfer (electron capture) of multiply charged ions and neutrals important in astrophysics. The electron transfer reactions with atoms and molecules is crucial to the ionization condition of neutral rich photoionized plasmas. With the successful deployment of the Far Ultraviolet Spectroscopic Explorer (FUSE) and the Chandra X-ray Observatory by NASA high resolution VUV and X-ray emission spectra fiom various astrophysical objects have been collected. These spectra will be analyzed to determine the source of the emission and the chemical and physical environment of the source. The proper interpretation of these spectra will require complete knowledge of all the atomic processes in these plasmas. In a neutral rich environment, charge transfer can be the dominant process. The rate coefficients need to be known accurately. We have also extended our charge transfer measurements to KeV region with a pulsed ion beam. The inclusion of this facility into our current program provides flexibility in extending the measurement to higher energies (KeV) if needed. This flexibility enables us to address issues of immediate interest to the astrophysical community as new observations are made by high resolution space based observatories.

Kwong, Victor H. S.↗

Part Marking and Identification Materials' for MISSE

The Materials on International Space Station Experiment (MISSE) is being conducted with funding from NASA and the U.S. Department of Defense, in order to evaluate candidate materials and processes for flight hardware. MISSE modules include test specimens used to validate NASA technical standards for part markings exposed to harsh environments in low-Earth orbit and space, including: atomic oxygen, ultraviolet radiation, thermal vacuum cycling, and meteoroid and orbital debris impact. Marked test specimens are evaluated and then mounted in a passive experiment container (PEC) that is affixed to an exterior surface on the International Space Station (ISS). They are exposed to atomic oxygen and/or ultraviolet radiation for a year or more before being retrieved and reevaluated. Criteria include percent contrast, axial uniformity, print growth, error correction, and overall grade. MISSE 1 and 2 (2001-2005), MISSE 3 and 4 (2006-2007), and MISSE 5 (2005-2006) have been completed to date. Acceptable results were found for test specimens marked with Data Matrix(TradeMark) symbols by Intermec Inc. and Robotic Vision Systems Inc using: laser bonding, vacuum arc vapor deposition, gas assisted laser etch, chemical etch, mechanical dot peening, laser shot peening, laser etching, and laser induced surface improvement. MISSE 6 (2008-2009) is exposing specimens marked by DataLase(Registed TradeMark), Chemico technologies Inc., Intermec Inc., and tesa with laser-markable paint, nanocode tags, DataLase and tesa laser markings, and anodized metal labels.

Roxby, Donald↗

Vacuum Ultraviolet Absorption Measurements of Atomic Oxygen in a Shock Tube

The absorption of vacuum ultraviolet light by atomic oxygen has been measured in the Electric Arc-driven Shock Tube (EAST) Facility at NASA-Ames Research Center. This investigation demonstrates the instrumentation required to determine atomic oxygen concentrations from absorption measurements in impulse facilities. A shock wave dissociates molecular oxygen, producing a high temperature sample of atomic oxygen in the shock tube. A probe beam is generated with a Raman-shifted ArF excimer laser. By suitable tuning of the laser, absorption is measured over a range of wavelengths in the region of the atomic line at 130.49 nm. The line shape function is determined from measurements at atomic oxygen densities of 3x10(exp 17) and 9x10(exp 17) cm(exp -3). The broadening coefficient for resonance interactions is deduced from this data, and this value is in accord with available theoretical models.

Meyer, Scott Andrew↗

Vacuum Ultraviolet Absorption Measurements of Atomic Oxygen in a Shock Tube

The absorption of vacuum ultraviolet light by atomic oxygen has been measured in the Electric Arc-driven Shock Tube (EAST) Facility at NASA-Ames Research Center. This investigation demonstrates the instrumentation required to determine atomic oxygen concentrations from absorption measurements in impulse facilities. A shock wave dissociates molecular oxygen, producing a high temperature sample of atomic oxygen in the shock tube. A probe beam is generated with a Raman-shifted ArF excimer laser. By suitable tuning of the laser, absorption is measured over a range of wavelengths in the region of the atomic line at 130.49 nm. The line shape function is determined from measurements at atomic oxygen densities of 3 x 10(exp 17) and 9 x 10(exp 17) cm(exp -3). The broadening coefficient for resonance interactions is deduced from this data, and this value is in accord with available theoretical models.

Meyer, Scott Andrew↗