Search NASA⌕ Search

SEARCH · Search NASA

Results for “VELOCITY PROBE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

The wedge hot-film anemometer in supersonic flow

A commercial wedge hot-film probe is studied to determine its heat transfer response in transonic to low supersonic flows of high unit Reynolds number. The results of this study show that its response in this flow regime differs from the response of cylindrical type sensors. Whereas the cylindrical sensor has the same sensitivity to velocity as to density for free-stream Mach numbers exceeding 1.3, the wedge probe sensitivity to velocity is always greater than its sensitivity to density over the entire flow regime. This property requires determination of three fluctuation components due to density, velocity, and temperature, in a transonic or supersonic turbulent flow. Sensitivity equations are derived based on the observed behavior of the wedge probe. Both the durability and the frequency response of the probe are excellent, the square wave insertion test indicating frequency response near 130 kHz. The directional response of the probe at sonic speed is poor and requires further examination before Reynolds stress measurements are attempted with dual sensor probes.

Seiner, J. M.↗

Measurement of Vortex Strength and Core Diameter in the Wake of a Hovering Rotor

Detailed hot wire measurements have been acquired in the tip vortex of a three-bladed model tilt rotor in hover. Testing was conducted at a rotor tip speed of 752 ft/sec, a Reynolds number (based on blade tip chord) of 1.77 x 10(exp 6), for thrust coefficients up to 0.0160. A figure shows the hot wire mounted above the inverted rotor at the Outside Aerodynamic Rotor Facility (OARF) at NASA Ames Research Center. Strobed shadowgraph flow visualization was used to define the vortex trajectory as an aid in hot wire positioning. Considerable variations in tip vortex structure with time were observed, even from the same blade, under essentially uniform test conditions. The only velocity signatures analyzed were those corresponding to passage of the probe directly through the center of the vortex. These time histories were ensemble averaged after compensating for jitter in the vortex arrival time at the probe, thereby retaining the core structure with minimal smearing. An example of a mean velocity signature, after ensemble averaging, is shown. The mean velocity signature was analyzed under the assumption of constant (unknown) translation speed of the vortex filament past the fixed probe. The translation speed of the vortex is deduced and the vortex strength and core diameter inferred. The results were highly unexpected. The indicated vortex strength is seen to decrease rapidly after first blade passage. In addition, the core radius is seen to decrease with increasing wake age, not increase as might be expected from simple diffusion.

Wadcock, Alan J.↗

United States Space Explorations 1958

The film describes preparation and launch of five satellites and two space probes during 1958. On January 31, a Jupiter vehicle launched Explorer I into space. Data from this satellite was used to identify the van Allen radiation belts. On March 17, a Vanguard I rocket launched an Earth satellite with solar batteries. Data from the mission was used to determine that the Earth is slightly pear-shaped. On March 26, Explorer III was launched to further study the van Allen belts, micrometeoroid impacts, and internal and external temperatures. Explorer IV, launched on July 26, was intended to study radiation and temperature data. A lunar probe, ABLE I, was intended to measure radiation, magnetic fields of Earth and the Moon, density of micrometeoric matter, and internal temperatures. A four-stage rocket was used in the launch. However, a turbo-pump failed and the liquid oxygen pump stopped, resulting in a failed mission. On October 10, Pioneer I was launched by an ABLE vehicle. First and second stage velocity was less than desired and the probe did not leave Earth orbit. Attempts to attain escape velocity were unsuccessful. On December, a Jupiter boost vehicle was used to launch Juno II, with Pioneer III as the payload. Escape velocity was reached and Pioneer III left Earth's atmosphere. Failed launches, such as those of Vanguard boost vehicles and several Explorer satellites, also added to scientific knowledge.

Source record↗

Growth of cosmic structure

We review one of the most fruitful areas in cosmology today that bridge theory and data - the temporal growth of large-scale structure. We go over the growth's physical foundations, and derive its behavior in simple cosmological models. While doing so, we explain how measurements of growth can be used to understand theory. We then review how some of the most mature cosmological probes-galaxy clustering, gravitational lensing, the abundance of clusters of galaxies, cosmic velocities, and cosmic microwave background-can be used to probe the growth of structure. We report the current constraints on growth, which are summarized as measurements of the parameter combination fσ 8 as a function of redshift, or else as the mass fluctuation amplitude parameter S 8 . Here, we finally illustrate several statistical approaches, ranging from the "growth index" parameterization to more general comparisons of growth and geometry, that can sharply test the standard cosmological model and indicate the presence of modifications to general relativity.

79 ASTRONOMY AND ASTROPHYSICS↗

Conventional probes for the relative flow measurement in a rotor blade passage

This paper reports the measurement of the relative flow in the rotor blade passages of an axial flow compressor and an axial flow inducer using conventional probes such as five-hole, disc and the spherical pitot-static probes. The probe provides an inexpensive, yet accurate, method of deriving the three dimensional flow field in a rotor. The disc probe is suitable for the blade boundary layer measurement and the pitot-static probe for the static and stagnation pressures and the total velocity across the rotor passage. Typical data obtained from each of these probes demonstrate the complex nature of turbomachinery rotor flow.

Sitaram, N.↗

Two-frequency laser-induced fluorescence technique for rapid velocity-field measurements in gas flows

A technique is presented for measurements of two-dimensional velocity fields in gas flows. The single-mode frequency of an argon-ion laser is fixed in the wing of an absorption line of iodine molecules that are seeded at low level in the flow of interest. The emitted fluorescence is detected with an image-intensified 100 x 100 photodiode-array camera. two pairs of counterpropagating laser sheets sequentially probe the flow to determine two velocity components. The frequency in one pair is shifted with respect to the other by an acousto-optic modulator. This two-frequency scheme eliminates the need to determine the slope of the line externally and offers the potential for combined pressure and velocity-field measurements.

Hiller, B.↗

Exploration of Options for Ultra-Fast Mass Spectroscopy for Pulsed Power Applications

Mega-ampere class pulsed power machines drive intense currents into small volumes to study high energy and density environments. Power lost during these events is a difficult and paramount problem to solve. For example, facilities such as Sandia National Laboratories’ Z machine experience meaningful power loss, which can be linked to non-linear ohmic heating at high currents (i.e., 26 MA on Z) leading to thermal desorption of contaminants and subsequent shunt plasma formation. Characterizing and understanding this type of thermal desorption is key to design optimizations necessary to minimize current loss, which will be even more important for next generation pulsed power. This type of characterization requires the ability to identify and determine concentration of analytes with nanosecond resolution given the pulse width of Z is on the order of 100 ns. This report summarizes progress on a small exploratory project focused on investigating options to meet this challenge using mass spectrometry. The main focus of these efforts utilized an Energy and Velocity Analyzer for Distributions of Electric Rockets intending to determine how quickly transient data could be resolved. This probe combines an electrostatic analyzer with a Wien velocity filter (ExB) to obtain ion energy and velocity distributions. Primary results from this exploratory project indicate significant additional work is needed to demonstrate a nanosecond time scale mass spectrometer for this application and also highlight that alternative detection methods such as laser-based diagnostics should be considered to meet the need for ultra-fast detection.

42 ENGINEERING↗

Pressure measuring probe

The invention is a prove (10) for measuring changes in pressure in a high velocity fluid streams over and adjacent the surface of an object. The probe (10) is formed of an exterior housing (11) having a closed pressure chamber (28) in which a piezo-electric pressure transducer (32) is mounted. an open connector tube (26) having a probe tip (29) passes a portion of said fluid stream into the closed pressure chamber (28), any change of pressure therein requiring a "settling-time" to appear in the closed pressure chamber (28) that is inversely proportional to the cross-sectional area of the connector tube (26). A cooling chamber (47) formed around the pressure chamber (28) is connected to a source of cooling fluid by means of inlet and outlet tubes (44) and (46), respectively.

George C Ashby, Jr↗

Intracavity Rayleigh/Mie Scattering for Multipoint, Two-Component Velocity Measurement

A simultaneous multi-point two-component Doppler velocimeter is described. The system uses two optical cavities: a Fabry-Perot etalon and an optical cavity for collecting and re-circulating the Rayleigh/Mie scattered light that is collected from the measurement volume in two parallel, but opposite directions. Single-pulse measurements of two orthogonal components of the velocity vector in a supersonic free jet were performed to demonstrate the technique. The re-circulation of the light rejected by the interferometer input mirror also increased the signal intensity by a factor of 3.5. 2005 Optical Society of America Interferometric Rayleigh scattering has previously been used for single-point velocity measurements in unseeded gas flow. However, this past work has generally been limited to probing with continuous-wave lasers resulting in time-averaged measurements of velocity. Multiple velocity components have been measured simultaneously by separate instruments.1,2 It has also been demonstrated that two orthogonal velocity components can be measured simultaneously at one point using one interferometer by reflecting back the probing laser beam, although this approach results in directional ambiguity of the flow velocity vector.3 This measurement ambiguity was removed by prior knowledge of the approximate magnitude and sign of the velocity components. Furthermore, it was shown that multiple points could be measured simultaneously with a Rayleigh scattering interferometric approach, but only one component of velocity was measured.4 Another method of performing multiple component velocity measurements with Rayleigh scattering uses a pair of cameras to image the flow, one of which views the flow through an iodine gas filter. This iodine-filter technique has the advantage of allowing high-resolution velocity imaging, but it generally has a lower dynamic range.

Bivolaru, Daniel↗

Characterizing Ion Transport in Electrolytes via Concentration and Velocity Profiles

Abstract Current flowing through an electrolyte is accompanied by continuum motion of ions and solvent, species concentration profiles, and the electric field. While, historically, the understanding of electrolyte transport has predominantly relied on interpreting macroscopic voltage (or current) measurements, recent advances in imaging and spectroscopic techniques allow velocity and concentration profiles to be probed directly. Such detailed information creates exciting opportunities—ranging from verifying theories describing transport in previously studied Li‐ion electrolytes, to new approaches for measuring properties as well as accurately and precisely quantifying transport in more complex electrolytes. Such emerging directions are herein discussed.

25 ENERGY STORAGE↗

Kinematic signature of a rotating bar near a resonance

Recent work based on H I, star count and emission data suggests that the Milky Way has rotating bar-like features. In this paper, I show that such features cause distinctive stellar kinematic signatures near Outer Lindblad Resonance (OLR) and Inner Lindblad Resonance (ILR). The effect of these resonances may be observable far from the peak density of the pattern and relatively nearby the solar position. The details of the kinematic signatures depend on the evolutionary history of the 'bar' and therefore velocity data, both systematic and velocity dispersion, may be used to probe the evolutionary history as well as the present state of Galaxy. Kinematic models for a variety of sample scenarios are presented. Models with evolving pattern speeds show significantly stronger dispersion signatures than those with static pattern speeds, suggesting that useful observational constraints are possible. The models are applied to the proposed rotating spheroid and bar models; we find (1) none of these models chosen to represent the proposed large-scale rotating spheroid are consistent with the stellar kinematics and (2) a Galactic bar with semimajor axis of 3 kpc will cause a large increase in velocity dispersion in the vicinity of OLR (approximately 5 kpc) with little change in the net radial motion and such a signature is suggested by K-giant velocity data. Potential future observations and analyses are discussed.

Weinberg, Martin D.↗

The Cassini/Huygens Doppler Wind Experiment: Results from the Titan Descent

The primary objective of the Doppler Wind Experiment (DWE), one of the six scientific investigations comprising the payload of the ESA Huygens Probe, is a determination of the wind velocity in Titan's atmosphere. Measurements of the Doppler shift of the S-band (2040 MHz) carrier signal to the Cassini Orbiter and to Earth were recorded during the Probe descent in order to deduce wind-induced motion of the Probe to an accuracy better than 1 m s-1. An experiment with the same scientific goal was performed with the Galileo Probe at Jupiter. Analogous to the Galileo experience, it was anticipated that the frequency of the Huygens radio signal could be measured on Earth to obtain an additional component of the horizontal winds. Specific secondary science objectives of DWE include measurements of: (a) Doppler fluctuations to determine the turbulence spectrum and possible wave activity in the Titan atmosphere; (b) Doppler and signal level modulation to monitor Probe descent dynamics (e.g., spinrate/spinphase, parachute swing); (c) Probe coordinates and orientation during descent and after impact on Titan.

Bird, M. K.↗

Evaluation of a self-aspirating local total enthalpy probe in a low-density arc-heated hypersonic wind tunnel

A shock-swallowing, self-aspirating, local total enthalpy probe has been evaluated in a low density nonequilibrium, hypervelocity airstream. The probe, which incorporated an air gap to separate the internal and external cooling passages, was tested in an electric archeated wind tunnel at an average Mach number of 11.7 and an average Reynolds number per meter of 57,000. The free stream enthalpy probe data are compared with bulk calorimeter measurements of total enthalpy at the beginning of the gas expansion and with local total enthalpy inferred from a theoretical nonequilibrium gas expansion model by using free stream velocity measurements obtained from a mass flow probe. The three techniques are in relative agreement at the lower enthalpies. However, at the higher enthalpies, the enthalpy probe data lie considerably below the other data. This low data may be caused by the chemical and vibrational energy frozen in the flow not being sensed by the probe. Other problems associated with the shock-swallowing total enthalpy probe are discussed, and recommendations for improving the probe performance are presented.

Guy, R. W.↗

An investigation of the flow characteristics in the blade endwall corner region

Studies were undertaken to determine the structure of the flow in the blade end wall corner region simulated by attaching two uncambered airfoils on either side of a flat plate with a semicircular leading edge. Detailed measurements of the corner flow were obtained with conventional pressure probes, hot wire anemometry, and flow visualization. The mean velocity profiles and six components of the Reynolds stress tensor were obtained with an inclined single sensor hot wire probe whereas power spectra were obtained with a single sensor oriented normal to the flow. Three streamwise vortices were identified based on the surface streamlines, distortion of total pressure profiles, and variation of mean velocity components in the corner. A horseshoe vortex formed near the leading edge of the airfoil. Within a short distance downstream, a corner vortex was detected between the horseshoe vortex and the surfaces forming the corner. A third vortex was formed at the rear portion of the corner between the corner vortex and the surface of the flat plate. Turbulent shear stress and production of turbulence are negligibly small. A region of negative turbulent shear stress was also observed near the region of low turbulence intensity from the vicinity of the flat plate.

Hazarika, Birinchi K.↗

Imaging grain microstructure in a model ceramic energy material with optically generated coherent acoustic phonons

Characterization of microstructure, chemistry and function of advanced energy materials remains a challenge for instrumentation science with tremendous opportunity for new discoveries. This active area of research is starting to make considerable strides with examples ranging from methodologies that employ bright X-rays, electron microscopy and optical spectroscopy. However, further development of instruments, capable of multimodal measurements, is necessary to fully reveal complex microstructure evolution in realistic environments and dynamical systems that are far from equilibrium. In this regard, laser-based instruments have a unique advantage as multiple measurement methodologies are easily combined into a single instrument using standard optics. A new pump-probe method that uses optically generated acoustic phonons is expanding standard optical characterization by providing depth resolved information. Here we report on a noteworthy extension of this pump-probe method to image grain microstructure in ceria. Rich information regarding the orientation of individual crystallites is obtained by monitoring acoustic phonon velocities and noting how the polarization of the probe beam influences the detected signal amplitude. When paired with other optical microscopies, this methodology will provide new perspectives for optical characterization of ceramic materials.

36 MATERIALS SCIENCE↗

A Flux Detection Probe to Quantify Dynamic Groundwater-Surface Water Exchange in the Hyporheic Zone

A new probe was designed to quantify groundwater-surface water exchange in the hyporheic zone under dynamic stage condition. Current methods focus on either vertical pore water velocity or Darcy flux measurements. Both parameters must be understood to evaluate residence time and mass flux of constituents. Furthermore, most instruments are not well suited for monitoring instantaneous velocity or flux under dynamic exchange conditions. For this reason, the flux detection probe (FDP) was designed that employs electrogeophysical measurements to estimate in situ sediment porosity, which can be used to convert pore water velocity to Darcy flux. Dynamic pore water velocity is obtained by monitoring fluid conductivity and temperature along the FDP probe. Pressure sensors deployed at the top and bottom of the probe provide the additional information necessary to estimate vertical permeability. This study focuses on the use of a geophysical method to estimate pore water velocity, porosity, and permeability within a controlled soil column where simulated river water displaces simulated groundwater. The difference between probe derived and theoretical pore water velocity using natural tracers such as electrical conductivity and temperature was -4.9 and 3.9% for downward flow and 1.1 and 12.8% for upward flow, respectively. The difference in porosity calculated from mass and volume packed in the soil column and probe measure porosity ranged between -3.2% and 1.5%. Also, the calculated hydraulic conductivity differed from probe derived values by -8.9%.

54 ENVIRONMENTAL SCIENCES↗

Spatio-temporal ion temperature and velocity measurements in a Z pinch using fast-framing spectroscopy

Ion Doppler spectroscopy (IDS) is a diagnostic technique that measures plasma ion temperature and velocity without perturbing the plasma with a physical probe. The ZaP-HD Flow Z-Pinch Experiment at the University of Washington uses this technique to resolve radial temperature and velocity profiles of a Z-pinch plasma. The pinch lifetime is approximately 100 ms, therefore diagnostics capable of sub-microsecond resolution are required to measure the evolution of temperature and velocity profiles. The previous IDS diagnostic system was only capable of collecting a single measurement during a plasma pulse. Here, an improved system has been developed to measure radially-resolved ion temperature and velocity for the entire Z-pinch lifetime. A Kirana 05M ultra-fast framing camera and SIL ultraviolet intensifier are used to record up to 100 spectra per plasma pulse. The temperature is computed from Doppler broadening of the carbon-III (229.687 nm) impurity ion radiation and the velocity from the Doppler shift of carbon-III. Measurements are able to resolve the evolution of the ion temperature and velocity over the course of a plasma pulse. The diagnostic has significantly reduced the number of pulses required and provides a more coherent measurement of plasma dynamics than the previous system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Interferometric phase velocity measurements in the auroral electrojet

A double-probe electric field detector and two spatially separated fixed-bias Langmuir probes were flown on a Taurus-Tomahawk sounding rocket launched from Poker Flat Research Range in March 1982. Interesting wave data have been obtained from about 10s of the downleg portion of the flight during which the rocket passed through the auroral electrojet. Here the electric field receiver and both density fluctuation (delta-n/n) receivers responded to a broad band of turbulence centered at 105 km-altitude and at frequencies generally below 4 kHz. Closer examination of the two delta-n/n turbulent waveforms reveals that they are correlated; from the phase difference between the two signals, the phase velocity of the waves in the rocket reference frame is inferred. The magnitude and direction of the observed phase velocity are consistent either with waves which travel at the ion sound speed or with waves which travel at the electron drift velocity. The observed phase velocity varies by about 50 percent over a 5 km altitude range, an effect which probably results from shear in the zonal neutral wind, although, unfortunately, no simultaneous neutral wind measurements exist to confirm this.

Labelle, J.↗