Flight Measurements of Stick Vibration of the YG-1B Autogiro Equipped with Tapered Rotor Blades

Records were made in f1iht of the periodic variation in the load in the control system of a YG-1B autogiro fitted with a new set of tapered rotor blades designed to eliminate periodic blade twist. Comparison with similar records obtained previously in tests of the ori6inal blades shows that the new blades considerably reduce the vibration of the control stick.

Bailey, Frederick J., Jr.↗

Measuring Work Functions Of "Dirty" Surfaces With A Vibrating Capacitive Probe

Apparatus measures work function of possibly contaminated surface of specimen of metal or other electrically conductive material. Measures work function of specimen indirectly, by vibrating capacitive measurement of contact potential. Work function of specimen affected by microstructure and by contamination.

Yost, William T.↗

Control-structures Interaction Test of the LACE Satellite

It is clear that additional experience and validation of Control Structures Interaction (CSI) techniques are needed in controlling the structural dynamics of flexible spacecraft. It is also clear that the effects of the space environment such as weightlessness dictate that this be done in space. Unfortunately, orbital tests are difficult to achieve because of the high cost of the test article, the launch into orbit, the instrumentation, and communication systems. The Low-power Atmospheric Compensation Experiment (LACE) Satellite has provided an opportunity to achieve a CSI test in space for very little cost. First, the CSI test rode piggy-back and did not interfere with the primary objective of LACE. Second, the novel technique of using ground based measurements of vibration of the orbiting satellite was employed. The LACE has a heavy central body to which is attached booms with lengths as long as 150 feet. The ground measurements were obtained using laser Doppler radar at the MIT Lincoln Laboratory Firepond Facility. The initial tests demonstrated the accuracy of the vibration measurements and obtained structural responses for enhancing the accuracy of the mathematical model of the structural dynamics. Germanium corner-cube retroreflectors attached to the central body and a boom deployed to 18 feet ensured a high strength return signal. Subsequent tests demonstrated the ability of an open-loop damper to attenuate the vibrations of the orbiting satellite. The LACE test results are important in contributing to the validation of a CSI technique, and demonstrating a novel ground measurement technique for orbital tests that is accurate but which has very low cost.

Taylor, Lawrence W., Jr.↗

Good Vibrations

A Small Business Innovation Research (SBIR) sponsorship from NASA's Dryden Flight Research Center, assisted MetroLaser, of Irvine, California, in the development of a self-aligned laser vibrometer system. VibroMet, capable of measuring surface vibrations in a variety of industries, provides information on the structural integrity and acoustical characteristics of manufactured products. This low-cost, easy-to-use sensor performs vibration measurement from distances of up to three meters without the need for adjustment. The laser beam is simply pointed at the target and the system then uses a compact laser diode to illuminate the surface and to subsequently analyze the reflected light. The motion of the surface results in a Doppler shift that is measured with very high precision. VibroMet is considered one of the many behind-the-scenes tools that can be relied on to assure the quality, reliability and safety of everything from airplane panels to disk brakes

Source record↗

Vibration characteristics of composite fan blades and comparison with measured data

The vibration characteristics of a composite fan blade for high-tip-speed applications were determined theoretically and the results compared with measured data. The theoretical results were obtained using a computerized capability consisting of NASTRAN coupled with composite mechanics by way of pre- and postprocessors. The predicted vibration frequencies and mode shapes were in reasonable agreement with the measured data. Theoretical results showed that different laminate configurations from the same composite system had only small effects on the blade frequency. However, the use of adhesively bonded titanium/beryllium laminar composites may improve considerably the blade vibration characteristics.

Chamis, C. C.↗

Vibration characteristics of composite fan blades and comparison with measured data

The vibration characteristics of a composite fan blade for high-tip-speed applications were determined theoretically and the results compared with measured data. The theoretical results were obtained using a computerized capability consisting of NASTRAN coupled with composite mechanics by way of pre- and postprocessors. The predicted vibration frequencies and mode shapes were in reasonable agreement with the measured data. Theoretical results showed that different laminate configurations from the same composite system had only small effects on the blade frequency. However, the use of adhesively bonded titanium/beryllium laminar composites may improve considerably the blade vibration characteristics.

Chamis, C. C.↗

Deriving Strain Modes From Vibrational Tests

Measurements and theoretical analysis complement each other. Experimental acceleration and strain data used to calculate coefficients of low-frequency vibrational modes of object under test. An iterative comparison of experimental and calculated strains give modal model of improved accuracy that predicts strains under operating conditions. Method useful in fatigue life and reliability analyses of buildings, pumps, engines, vehicles, and other systems subject to vibrations and loud noises during operation.

Young, J. W.↗

Hydroxyl Tagging Velocimetry Demonstration in an Augmented Spark Igniter

Hydroxyl tagging velocimetry (HTV) involves tagging a flow by “writing” a line of OH molecules using a laser beam to dissociate H2O molecules and capturing an image of the line after a short delay using laser-induced fluorescence. Velocity is obtained by a time-of-flight analysis of the data. In this effort, HTV was used for obtaining both instantaneous and average velocity profiles in the flow of an augmented spark igniter. Two modes of camera readout were investigated, called conventional full frame mode and dual image mode feature (DIF) mode. In DIF mode, two images are captured in quick succession and therefore the measurement is immune to vibration effects. Measurement uncertainty for the DIF case varied from 3% at the centerline to 10% at the edges of the profile in a 1000-m/s flow. For the full-frame case, measurement uncertainty varied from 3% at the centerline to 7% at the edges. This demonstration provides evidence that the HTV technique is well suited for obtaining velocity profiles in the challenging environment of either a rocket engine or rocket engine igniter.

Augmented Spark Igniter↗

Combined Amplitude and Frequency Measurements for Non-Contacting Turbomachinery Blade Vibration

A method and apparatus for measuring the vibration of rotating blades, such as turbines, compressors, fans, or pumps, including sensing the return signal from projected energy and/or field changes from a plurality of sensors mounted on the machine housing. One or more of the sensors has a narrow field of measurement and the data is processed to provide the referenced time of arrival of each blade, and therefore the blade tip deflection due to vibration. One or more of the sensors has a wide field of measurement, providing a time history of the approaching and receding blades, and the data is processed to provide frequency content and relative magnitudes of the active mode(s) of blade vibration. By combining the overall tip deflection magnitude with the relative magnitudes of the active modes, the total vibratory stress state of the blade can be determined.

Platt, Michael J.↗

NIST torsion oscillator viscometer response: Performance on the LeRC active vibration isolation platform

Critical point viscosity measurements are limited to their reduced temperature approach to T(sub c) in an Earth bound system, because of density gradients imposed by gravity. Therefore, these classes of experiments have been proposed as good candidates for 'microgravity' science experiments where this limitation is not present. The nature of these viscosity measurements dictate hardware that is sensitive to low frequency excitations. Because of the vibratory acceleration sensitivity of a torsion oscillator viscometer, used to acquire such measurements, a vibration isolation sensitivity test was performed on candidate 'microgravity' hardware to study the possibility of meeting the stringent oscillatory sensitivity requirements of a National Institute of Standards and Technology (NIST) torsion oscillator viscometer. A prototype six degree of freedom active magnetic isolation system, developed at NASA Lewis Research Center, was used as the isolation system. The ambient acceleration levels of the platform were reduced to the noise floor levels of its control sensors, about one microgravity in the 0.1 to 10 Hz bandwidth.

Berg, Robert F.↗

Photo-Optical Blade-Vibration-Data Acquisition System

Techniques developed for measuring blade vibrations using optical sensors fixed in casing around bladed turbine-engine stage. Measurement system coordinates and assembles inputs of many optical probes in order to monitor all of blades on spinning stage. Several points on every blade monitored in order to develop quantitative measure of overall bladed-stage response.

Kiraly, L. J.↗

Radiative properties of molecular nitrogen ions produced by helium Penning ionization and argon effects

The development of hypersonic aerospace vehicles requires a better understanding on the thermal and chemical nonequilibrium kinetics of participating species in shock layers. The computational fluid dynamic (CFD) codes developed for such flowfields overestimate the radiation in the spectral region of 300 - 600 nm. A speculation for this overestimation is that inclusion of Ar, CO2, and H2O at the upper atmosphere flight region makes a significant impact on radiative kinetics of molecular nitrogen ions. To define the effects of minority species on the radiative kinetics of N2(+), an experimental setup was made by using the helium Penning ionization. The vibrational and rotational temperature were measured by mapping the vibrational and rotational distributions of N2(+) emission with high spectroscopic resolution and absolute intensity measurements. Measured vibrational temperatures were in the range from 18,000 to 36,000 K, and rotational temperatures were in the range from 300 to 370 K. The irradiance of 391.44 nm line and rotational and vibrational temperatures were analyzed to define argon and CO2 effects on the N2(+) emission. When Ar or CO2 is injected with N2, the rotational temperature did not change. The irradiances were reduced by 34 percent and 78 percent for the 50 percent of mixture of Ar and CO2, respectively. The vibrational temperatures were increased by 24.1 percent and 82.9 percent for the 50 percent of mixture of Ar and CO2, respectively. It appears that there are no significant effects from small concentrations of Ar and CO2 at the upper atmosphere flight region.

Miller, George, III↗

Mirror Metrology Using Nano-Probe Supports

Thin, lightweight mirrors are needed for future x-ray space telescopes in order to increase x-ray collecting area while maintaining a reduced mass and volume capable of being launched on existing rockets. However, it is very difficult to determine the undistorted shape of such thin mirrors because the mounting of the mirror during measurement causes distortion. Traditional kinematic mounts have insufficient supports to control the distortion to measurable levels and prevent the mirror from vibrating during measurement. Over-constrained mounts (non-kinematic) result in an unknown force state causing mirror distortion that cannot be determined or analytically removed. In order to measure flexible mirrors, it is necessary to over-constrain the mirror. Over-constraint causes unknown distortions to be applied to the mirror. Even if a kinematic constraint system can be used, necessary imperfections in the kinematic assumption can lead to an unknown force state capable of distorting the mirror. Previously, thicker, stiffer, and heavier mirrors were used to achieve low optical figure distortion. These mirrors could be measured to an acceptable level of precision using traditional kinematic mounts. As lighter weight precision optics have developed, systems such as the whiffle tree or hydraulic supports have been used to provide additional mounting supports while maintaining the kinematic assumption. The purpose of this invention is to over-constrain a mirror for optical measurement without causing unacceptable or unknown distortions. The invention uses force gauges capable of measuring 1/10,000 of a Newton attached to nano-actuators to support a thin x-ray optic with known and controlled forces to allow for figure measurement and knowledge of the undeformed mirror figure. The mirror is hung from strings such that it is minimally distorted and in a known force state. However, the hanging mirror cannot be measured because it is both swinging and vibrating. In order to stabilize the mirror for measurement, nano-probes support the mirror, causing the mirror to be over-constrained.

Robinson, David↗