Tower and rotor blade vibration test results for a 100-kilowatt wind turbine

The predominant natural frequencies and mode shapes for the tower and the rotor blades of the ERDA-NASA 100-kW wind turbine were determined. The tests on the tower and the blades were conducted both before and after the rotor blades and the rotating machinery were installed on top of the tower. The tower and each blade were instrumented with an accelerometer and impacted by an instrumented mass. The tower and blade structure was analyzed by means of NASTRAN, and computed values agree with the test data.

Linscott, B. S.↗

Modal confidence factor in vibration testing

The modal confidence factor (MCF) is a number calculated for every identified mode for a structure under test. The MCF varies from 0.00 for a distorted nonlinear, or noise mode to 100.0 for a pure structural mode. The theory of the MCF is based on the correlation that exists between the modal deflection at a certain station and the modal deflection at the same station delayed in time. The theory and application of the MCF are illustrated by two experiments. The first experiment deals with simulated responses from a two-degree-of-freedom system with 20%, 40%, and 100% noise added. The second experiment was run on a generalized payload model. The free decay response from the payload model contained 22% noise.

Ibrahim, S. R.↗

Modal confidence factor in vibration testing

The theory and applications of a time domain modal test technique are presented. The method uses free decay of random responses from a structure under test to identify its modal characteristics namely, natural frequencies, damping factors, and mode shapes. The method can identify multimodal (highly coupled) systems and modes that have very small contribution in the responses. A method is presented to decrease the effects of high levels of noise in the data and thus improve the accuracy of identified parameters. This is accomplished using an oversized mathematical model. The concept of modal confidence factor (MCF) is developed. The MCF is a number calculated for every identified mode for a structure under test. The MCF varies from 0.000 for a distorted, nonlinear, or noise mode to 100.0 for a pure structural mode. The theory of the MCF is based on the correlation that exits between the modal deflection at a certain station and the modal deflection at the same station delayed in time. The theory and application of the MCF is illustrated by two experiments. The first experiment deals with simulated responses from a two degree of freedom system with 20 percent, 40 percent, and 100 percent noise added. The second experiment was run on a generalized payload model. The free decay response from the payload model contained about 22 percent noise.

Ibrahim, S. R.↗

Improvement of a large dynamic analytical model using ground vibration test data

A method has been developed which uses measured normal modes and natural frequencies to improve an analytical mass and stiffness matrix model of a structure. The method directly identifies, without iteration, a set of minimum changes in the analytical matrices which force the eigensolutions to agree with the test measurements. An application is presented in which the analytical model had 508 degrees of freedom and 19 modes were measured at 101 locations on the structure. The resulting changes in the model are judged to be small compared to expectations of errors in the analysis. Thus the improved model is accepted as a reasonable model of the structure with improved dynamic response characteristics. In addition, it is shown that the procedure may be a useful tool in identifying apparent measured modes which are not true normal modes of the structures.

Berman, A.↗

Radial SI latches vibration test data review

Dynamic testing of the Space Telescope Scientific Instrument Radial Latches was performed as specified by the designated test criteria. No structural failures were observed during the test. The alignment stability of the instrument simulator was within required tolerances after testing. Particulates were discovered around the latch bases, after testing, due to wearing at the B and C latch interface surfaces. This report covers criteria derivation, testing, and test results.

Harrison, P. M.↗

On-orbit vibration testing for space structures

A simulated on-orbit modal test using active members as the excitation source has been performed on the Precision Truss. Using the step sine testing technique, the frequency response functions are obtained and the modal parameters are extracted by the curve-fitting method. A total of 10 global modes and 3 local modes are obtained. The results are compared with those obtained by the conventional external excitation test.

Chen, Jay-Chung↗

Laboratory evaluation of two advanced suspension devices for ground vibration testing of large space structures

In order to provide the advanced suspension technology needed to allow ground test measurement of free-body modal parameters, two advanced suspension devices, one passive, the other active, are evaluated on the basis of laboratory testing of each device type with rigid and flexible payloads. Rigid-body tests show the basic behavior of the devices when they are uncoupled from a test article near their bandwidth. Flexible body tests show how suspension device dynamics couple with the dynamics of a representative large space structure. For the flexible body testing, targets for the free-body modal parameters are developed from test-verified analysis of the representative structure suspended in an orientation which is only mildly sensitive to suspension constraints.

Cooley, Victor M.↗

Vibration Test With Extremal Dual Control

Report discusses use of extremal dual control to prevent overtesting. In extremal dual control, electronic test-control subsystem automatically reduces excitation supplied to shaker subsystem to keep force applied by shaker below preset force limit and to keep acceleration of shaker below preset acceleration limit.

Scharton, Terry D.↗

Mass-Additive Vibration Testing Of Constrained Structures

Report describes study of mass-additive method of modal survey testing of flexible structures that, in normal use, constrained by other structures. Structure normally constrained by another structure is suspended freely and extra masses attached to boundary.

Admire, John R.↗

Ground Vibration Test Planning and Pre-Test Analysis for the X-33 Vehicle

This paper describes the results of the modal test planning and the pre-test analysis for the X-33 vehicle. The pre-test analysis included the selection of the target modes, selection of the sensor and shaker locations and the development of an accurate Test Analysis Model (TAM). For target mode selection, four techniques were considered, one based on the Modal Cost technique, one based on Balanced Singular Value technique, a technique known as the Root Sum Squared (RSS) method, and a Modal Kinetic Energy (MKE) approach. For selecting sensor locations, four techniques were also considered; one based on the Weighted Average Kinetic Energy (WAKE), one based on Guyan Reduction (GR), one emphasizing engineering judgment, and one based on an optimum sensor selection technique using Genetic Algorithm (GA) search technique combined with a criteria based on Hankel Singular Values (HSV's). For selecting shaker locations, four techniques were also considered; one based on the Weighted Average Driving Point Residue (WADPR), one based on engineering judgment and accessibility considerations, a frequency response method, and an optimum shaker location selection based on a GA search technique combined with a criteria based on HSV's. To evaluate the effectiveness of the proposed sensor and shaker locations for exciting the target modes, extensive numerical simulations were performed. Multivariate Mode Indicator Function (MMIF) was used to evaluate the effectiveness of each sensor & shaker set with respect to modal parameter identification. Several TAM reduction techniques were considered including, Guyan, IRS, Modal, and Hybrid. Based on a pre-test cross-orthogonality checks using various reduction techniques, a Hybrid TAM reduction technique was selected and was used for all three vehicle fuel level configurations.

Bedrossian, Herand↗

Membrane Vibration Tests Using Surface-Bonded Piezoelectric Patch Actuation

This paper describes the status of on-going work at the NASA Langley Research Center to measure the dynamics of thin membranes. The test article is a one-meter square pre-tensioned Kapton membrane that incorporates small surface-bonded piezoelectric patches strategically positioned to excite many modes. It is shown that PVDF (polyvinylidene fluoride) and MFC (macro fiber composite) piezoelectric patch actuators provide adequate excitation energy to obtain modal frequencies and mode shapes. Results from modal tests performed on the membrane using piezoelectric patches of different sizes and positions are discussed.

Gasper, James L.↗

Evaluation of Thermal Protection Tile Transmissibility for Ground Vibration Test

Transmissibility analyses and tests were conducted on a composite panel with thermal protection system foams to evaluate the quality of the measured frequency response functions. Both the analysis and the test results indicate that the vehicle dynamic responses are fully transmitted to the accelerometers mounted on the thermal protection system in the normal direction below a certain frequency. In addition, the in-plane motions of the accelerometer mounted on the top surface of the thermal protection system behave more actively than those on the composite panel due to the geometric offset of the accelerometer from the panel in the test set-up. The transmissibility tests and analyses show that the frequency response functions measured from the accelerometers mounted on the TPS will provide accurate vehicle responses below 120 Hz for frequency and mode shape identification. By confirming that accurate dynamic responses below a given frequency can be obtained, this study increases the confidence needed for conducting the modal testing, model correlation, and model updating for a vehicle installed with TPS. '

Chung, Y. T.↗