Search NASA⌕ Search

SEARCH · Search NASA

Results for “Views”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Feasibility of low-dose single-view 3D fiducial tracking concurrent with external beam delivery

Purpose: In external-beam radiation therapy, existing on-board x-ray imaging chains orthogonal to the delivery beam cannot recover 3D target trajectories from a single view in real-time. This limits their utility for real-time motion management concurrent with beam delivery. To address this limitation, the authors propose a novel concept for on-board imaging based on the inverse-geometry Scanning-Beam Digital X-ray (SBDX) system and evaluate its feasibility for single-view 3D intradelivery fiducial tracking. Methods: A chest phantom comprising a posterior wall, a central lung volume, and an anterior wall was constructed. Two fiducials were placed along the mediastinal ridge between the lung cavities: a 1.5 mm diameter steel sphere superiorly and a gold cylinder (2.6 mm length x 0.9 mm diameter) inferiorly. The phantom was placed on a linear motion stage that moved sinusoidally. Fiducial motion was along the source-detector (z) axis of the SBDX system with {+-}10 mm amplitude and a programmed period of either 3.5 s or 5 s. The SBDX system was operated at 15 frames per second, 100 kVp, providing good apparent conspicuity of the fiducials. With the stage moving, detector data were acquired and subsequently reconstructed into 15 planes with a 12 mm plane-to-plane spacing using digital tomosynthesis. A tracking algorithm was applied to the image planes for each temporal frame to determine the position of each fiducial in (x,y,z)-space versus time. A 3D time-sinusoidal motion model was fit to the measured 3D coordinates and root mean square (RMS) deviations about the fitted trajectory were calculated. Results: Tracked motion was sinusoidal and primarily along the source-detector (z) axis. The RMS deviation of the tracked z-coordinate ranged from 0.53 to 0.71 mm. The motion amplitude derived from the model fit agreed with the programmed amplitude to within 0.28 mm for the steel sphere and within -0.77 mm for the gold seed. The model fit periods agreed with the programmed periods to within 7%. Conclusions: Three dimensional fiducial tracking with approximately 1 mm or better accuracy and precision appears to be feasible with SBDX, supporting its use to guide radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterization of a constrained paired-view technique in iterative reconstruction for breast tomosynthesis

Purpose: The order in which the projection views are employed in the reconstruction of tomosynthesis by iterative algorithms, such as simultaneous algebraic reconstruction technique and maximum likelihood, has a strong effect on the rate of convergence, accuracy, and the edge-blurring artifacts in the reconstructed image. The purpose of this investigation was to characterize and evaluate the effects of ordering schemes on image quality for breast tomosynthesis reconstruction and to explore a new constrained paired-view technique that could provide reduction of reconstruction artifacts. In this work, the authors compared several different ordering schemes and characterized the image quality and the formation of out-of-plane artifacts. Furthermore, a new normalization method is presented. It produces more accurate reconstructions with reduced artifacts comparing to the standard method of sequential ordering.Methods: In addition to visual assessment of image quality, several indices such as the signal-difference-to-noise ratio, the artifact-spread function, and the lesion detectability (d{sup ′}) were computed to quantitatively evaluate the effect of ordering scheme. The sets of breast tomosynthesis projection images were simulated for reconstruction; one set had uniform background (white noise only) and the other two contained both anatomic background and quantum noise. Clinical breast images were also studied for comparison.Results: The authors have quantified the image quality in reconstructed slices for a range of tumor sizes. The authors’ proposed method provides better performance for all of the metrics tested (contrast, d{sup ′}, and the level of artifacts) both for the uniform phantom case and in the presence of anatomical structure.Conclusions: The paired projection normalization provides better performance in the image quality of the reconstructed slices, and results in a lower level of artifacts in the Z direction. This implies that even a relatively simple method like the “side-to-side” sequence, which pairs two symmetrical projections with equal angular distance from the central projection, would achieve better reconstructed image quality than the conventional “step-by-step” method, which uses sequential projections one after another.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multichannel response analysis on 2D projection views for detection of clustered microcalcifications in digital breast tomosynthesis

Purpose: To investigate the feasibility of a new two-dimensional (2D) multichannel response (MCR) analysis approach for the detection of clustered microcalcifications (MCs) in digital breast tomosynthesis (DBT). Methods: With IRB approval and informed consent, a data set of two-view DBTs from 42 breasts containing biopsy-proven MC clusters was collected in this study. The authors developed a 2D approach for MC detection using projection view (PV) images rather than the reconstructed three-dimensional (3D) DBT volume. Signal-to-noise ratio (SNR) enhancement processing was first applied to each PV to enhance the potential MCs. The locations of MC candidates were then identified with iterative thresholding. The individual MCs were decomposed with Hermite–Gaussian (HG) and Laguerre–Gaussian (LG) basis functions and the channelized Hotelling model was trained to produce the MCRs for each MC on the 2D images. The MCRs from the PVs were fused in 3D by a coincidence counting method that backprojects the MC candidates on the PVs and traces the coincidence of their ray paths in 3D. The 3D MCR was used to differentiate the true MCs from false positives (FPs). Finally a dynamic clustering method was used to identify the potential MC clusters in the DBT volume based on the fact that true MCs of clinical significance appear in clusters. Using two-fold cross validation, the performance of the 3D MCR for classification of true and false MCs was estimated by the area under the receiver operating characteristic (ROC) curve and the overall performance of the MCR approach for detection of clustered MCs was assessed by free response receiver operating characteristic (FROC) analysis. Results: When the HG basis function was used for MCR analysis, the detection of MC cluster achieved case-based test sensitivities of 80% and 90% at the average FP rates of 0.65 and 1.55 FPs per DBT volume, respectively. With LG basis function, the average FP rates were 0.62 and 1.57 per DBT volume at the same sensitivity levels. The difference in the two sets of basis functions for detection of MCs did not show statistical significance. Conclusions: The authors' experimental results indicate that the MCR approach is promising for the detection of MCs on PV images. The HG or LG basis functions are both effective in characterizing the signal response of MCs using the channelized Hotelling model. The coincidence counting method for fusion of the 2D MCR in 3D is an important step for FP reduction. Further study is underway to improve the MCR approach for microcalcification detection in DBT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TU-C-12A-05: Repeatability Study of Reduced Field-Of-View Diffusion-Weighted MRI On Human Thyroid Gland

Purpose: To investigate the repeatability of reduced field-of-view diffusion-weighted imaging (rFOV DWI) in quantifying apparent diffusion coefficients (ADCs) for human thyroid glands in a clinical setting. Methods: Nine healthy human volunteers were enrolled and underwent 3T MRI exams. For each volunteer, 3 longitudinal exams (2 weeks apart) with 2 repetitive sessions within each exam, including rFOV and conventional full field-of-view (fFOV) DWI scans, were performed. In the acquired DWI images, a fixed-size region of interest (ROI; diameter=8mm) was placed on thyroid glands to calculate ADC. ADC was calculated using a monoexponential function with a noise correction scheme. The repeatability of ADC was assessed by using coefficient variation (CV) across sessions or exams, which was defined to be: r = 1-CV, 0 < r < 1, where CV=STD/m, STD is the standard deviation of ADC, and m is the average of ADC across sessions or exams. An experienced radiologist assessed and scored rFOV and fFOV DW images based on image characteristics (1, nondiagnostic; 2, poor; 3, satisfactory; 4, good; and 5, excellent).Analysis of variance (ANOVA) was performed to compare ADC values, CV of ADC, repeatability of ADC across sessions and exams, and radiologic scores between rFOV and fFOV DWI techniques. Results: There was no significant difference in ADC values across sessions and exams either in rFOV or fFOV DWI. The average CVs of both rFOV and fFOV DWI were less than 13%. The repeatability of ADC measurement between rFOV and fFOV DWI was not significantly different. The overall image quality was significantly higher with rFOV DWI than with fFOV DWI. Conclusion: This study suggested that ADCs from both rFOV and fFOV DWI were repeatable, but rFOV DWI had superior imaging quality for human thyroid glands in a clinical setting.

60 APPLIED LIFE SCIENCES↗

TH-E-17A-10: Markerless Lung Tumor Tracking Based On Beams Eye View EPID Images

Purpose: Dynamic tumor tracking or motion compensation techniques have proposed to modify beam delivery following lung tumor motion on the flight. Conventional treatment plan QA could be performed in advance since every delivery may be different. Markerless lung tumor tracking using beams eye view EPID images provides a best treatment evaluation mechanism. The purpose of this study is to improve the accuracy of the online markerless lung tumor motion tracking method. Methods: The lung tumor could be located on every frame of MV images during radiation therapy treatment by comparing with corresponding digitally reconstructed radiograph (DRR). A kV-MV CT corresponding curve is applied on planning kV CT to generate MV CT images for patients in order to enhance the similarity between DRRs and MV treatment images. This kV-MV CT corresponding curve was obtained by scanning a same CT electron density phantom by a kV CT scanner and MV scanner (Tomotherapy) or MV CBCT. Two sets of MV DRRs were then generated for tumor and anatomy without tumor as the references to tracking the tumor on beams eye view EPID images. Results: Phantom studies were performed on a Varian TrueBeam linac. MV treatment images were acquired continuously during each treatment beam delivery at 12 gantry angles by iTools. Markerless tumor tracking was applied with DRRs generated from simulated MVCT. Tumors were tracked on every frame of images and compared with expected positions based on programed phantom motion. It was found that the average tracking error were 2.3 mm. Conclusion: This algorithm is capable of detecting lung tumors at complicated environment without implanting markers. It should be noted that the CT data has a slice thickness of 3 mm. This shows the statistical accuracy is better than the spatial accuracy. This project has been supported by a Varian Research Grant.

60 APPLIED LIFE SCIENCES↗

SU-E-T-330: Dosimetric Impact of Intrafraction Respiratory Motion On Lung SBRT Treatment Using Cyberknife 0-View Tracking Mode

Purpose: To investigate the influence of respiratory motion on the delivered dose in lung stereotactic body radiotherapy (SBRT) using Cyberknife (CK) 0-View tracking mode. Methods: CT scans at inspiration and expiration of an anthropomorphic motion phantom were fused base on the spine and an internal target volume (ITV) was created. A 5mm expansion around the ITV resulted in the planning target volume. Three CK plans were generated in Accuray MultiPlan using Lung Optimization Tracking 0-View technique with the minimum MU per beam set to (a) 5MU, (b) 15MU and (c) 30MU, respectively. Doses were calculated on the expiration CT using Monte-Carlo algorithm. Each plan was delivered 5 times with a range of different starting phases in the respiratory cycle to assess the dose variation due to interplay effect. The delivered dose was measured with EBT3 Gafchromic film which was inserted in the moving target of the phantom. The target motion range is 3 cm in superior-inferior (SI) direction with the breathing period of 5 seconds. Results: The gamma analysis (5%/2mm) of the dose with the films in the transverse plane resulted in average passing rate of 95.5±4.1%, 96.7±2.6%, and 96.2±2.5% for plan (a), (b), and (c), respectively. For the sagittal films, the average passing rate was 91.1±4.9%, 92.1±3.6%, and 92.3±2.9% for the three plans, respectively. The disagreement between measurement and dose calculations were mostly on the target edges in SI direction. The mean measured versus calculated dose differences at the edge of target in SI direction were (a) 3.9±4.8%, (b) 2.4±3.3%, and (c) 2.2±3.2% for the three plans, respectively. Conclusions: The plans with low-MU beams (below 10MU) tend to cause slightly larger dose variation. However in terms of target coverage, the overall clinical dosimetric impact of the intrafraction respiratory motion in lung SBRT is insignificant when averaged over 3∼5 fractions.

60 APPLIED LIFE SCIENCES↗

MO-DE-207A-11: Sparse-View CT Reconstruction Via a Novel Non-Local Means Method

Purpose: Sparse-view computed tomography (CT) reconstruction is an effective strategy to reduce the radiation dose delivered to patients. Due to its insufficiency of measurements, traditional non-local means (NLM) based reconstruction methods often lead to over-smoothness in image edges. To address this problem, an adaptive NLM reconstruction method based on rotational invariance (RIANLM) is proposed. Methods: The method consists of four steps: 1) Initializing parameters; 2) Algebraic reconstruction technique (ART) reconstruction using raw projection data; 3) Positivity constraint of the image reconstructed by ART; 4) Update reconstructed image by using RIANLM filtering. In RIANLM, a novel similarity metric that is rotational invariance is proposed and used to calculate the distance between two patches. In this way, any patch with similar structure but different orientation to the reference patch would win a relatively large weight to avoid over-smoothed image. Moreover, the parameter h in RIANLM which controls the decay of the weights is adaptive to avoid over-smoothness, while it in NLM is not adaptive during the whole reconstruction process. The proposed method is named as ART-RIANLM and validated on Shepp-Logan phantom and clinical projection data. Results: In our experiments, the searching neighborhood size is set to 15 by 15 and the similarity window is set to 3 by 3. For the simulated case with a resolution of 256 by 256 Shepp-Logan phantom, the ART-RIANLM produces higher SNR (35.38dB<24.00dB) and lower MAE (0.0006<0.0023) reconstructed image than ART-NLM. The visual inspection demonstrated that the proposed method could suppress artifacts or noises more effectively and preserve image edges better. Similar results were found for clinical data case. Conclusion: A novel ART-RIANLM method for sparse-view CT reconstruction is presented with superior image. Compared to the conventional ART-NLM method, the SNR and MAE from ART-RIANLM increases 47% and decreases 74%, respectively.

60 APPLIED LIFE SCIENCES↗

Gated-Viewing System with an Electronic Shutter on a CCD Image Sensor

The results of the development and experimental investigation of the gated-viewing method without the using an image intensifier as a fast shutter are presented. The device for implementing the method consists of an interline CCD image sensor with an input lens and 906 nm pulsed laser diode with an output lens that forms an illumination beam. The gated-viewing method is based on the original CCD control procedure, which allows observing multiple pulses without lowering the frame rate. Experimental studies have shown the method feasibility under conditions of smoke and fog.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A local-view array library for partitioned global address space C++programs

Multidimensional arrays are an important data structure in many scientific applications. Unfortunately, built-in support for such arrays is inadequate in C++, particularly in the distributed setting where bulk communication operations are required for good performance. In this paper, we present a multidimensional library for partitioned global address space (PGAS) programs, supporting the one-sided remote access and bulk operations of the PGAS model. The library is based on Titanium arrays, which have proven to provide good productivity and performance. These arrays provide a local view of data, where each rank constructs its own portion of a global data structure, matching the local view of execution common to PGAS programs and providing maximum flexibility in structuring global data. Unlike Titanium, which has its own compiler with array-specific analyses, optimizations, and code generation, we implement multidimensional arrays solely through a C++library. The main goal of this effort is to provide a library-based implementation that can match the productivity and performance of a compiler-based approach. We implement the array library as an extension to UPC++, a C++library for PGAS programs, and we extend Titanium arrays with specializations to improve performance. We evaluate the array library by porting four Titanium benchmarks to UPC++, demonstrating that it can achieve up to 25% better performance than Titanium without a significant increase in programmer effort..

Kamil, A↗

EnergyPlus View Factor Calculation

The Python code takes EnergyPlus input files and creates input for the View3D program, executes the View3D program, then inserts the respective view factors into the EnergyPlus input file, thus streamlining the process of view factor calculation and modification of the EnergyPlus input file.

Kunwar, Niraj [Oak Ridge National Laboratory (ORNL↗

Observing clouds in 4D with multi-view stereo photogrammetry

We report that newly installed stereo cameras ringing the Southern Great Plains (SGP) Atmospheric Radiation Measurement (ARM) site in Oklahoma are providing a 4D gridded view of shallow clouds. Six digital cameras have been installed in pairs at a distance of 6 kilometers from the site and with a spacing of 500 meters between cameras in a pair. These pairs of cameras provide stereoscopic views of shallow clouds from all sides; when these data are combined, they allow for a complete stereo reconstruction. The result – the Clouds Optically Gridded by Stereo (COGS) product – is a 4D grid of cloudiness covering a 6 km × 6 km × 6 km cube at a spatial resolution of 50 meters and a temporal resolution of 20 seconds. This provides an unprecedented set of data on the sizes, lifetimes, and lifecycles of shallow clouds. Lastly, this type of information is critical for developing cloud macrophysical schemes for the next generation of weather and climate models.

47 OTHER INSTRUMENTATION↗

AmeriFlux FLUXNET-1F US-UTV UFLUX Desert View

This is the AmeriFlux Management Project (AMP) created FLUXNET-1F version of the carbon flux data for the site US-UTV UFLUX Desert View. This is the FLUXNET version of the carbon flux data for the site US-UTV UFLUX Desert View produced by applying the standard ONEFlux (1F) software. Site Description - This station is located alongside a large pivot that irrigate alfalpha.

Ladig, Kathryn [Utah Geological Survey]↗

Use Case Realization Report: UCR-08.05 Views Event History

This architecturally significant use case describes how the System User observes the change history of a given event. The change history is a series of one or more saved event hypotheses. System Users view all the event hypotheses and the set of location solutions for each hypothesis. The System User views the relationship between event hypotheses including the preferred hypothesis for each processing stage. The event change history persists across work sessions for subsequent review. This use case is architecturally significant because it covers review of stored versions of event hypotheses

97 MATHEMATICS AND COMPUTING↗

Final Report, “Exploiting Global View for Resilience”

Final technical report for the "Exploiting Global View for Resilience" project. The GVR project aims to create a new approach to portable, resilient applications. The GVR approach builds on a global view data model,, adding versioning (multi-version), user control of timing and rate (multi-stream), and flexible cross layer error signalling and recovery. With a versioned array as a portable abstraction, GVR enables application programmers to exploit deep scientific and application code insights to manage resilience (and its overhead) in a flexible, portable fashion.

97 MATHEMATICS AND COMPUTING↗

Consumer Views: Importance of Fuel Economy

This presentation includes data captured by the National Renewable Energy Laboratory (NREL) to support the U.S. Department of Energy's Vehicle Technologies Office (VTO) research efforts. The data capture consumer views on the importance of fuel economy amongst other vehicle attributes and views on which alternative fuel types would be the best and worst replacements for gasoline.

33 ADVANCED PROPULSION SYSTEMS↗

Chamber Interior Viewing System (CIVS 2.0)

The NIF facility is used to conduct fusion and high-density scientific research. The experiments are conducted inside of a 10-meter diameter vacuum chamber called the “Target Chamber”. The target chamber is covered in ports to permit adding equipment to the exterior. Some of this equipment extends into the target chamber such as the target positioners and diagnostics. Other equipment sits on the surface and looks inward, such as the CIVS system. CIVS stands for Chamber Interior Viewing System. The CIVS system provides simple black and white digital images of the interior of the target chamber in real time. These images are used for positioner alignment, trouble shooting and observing for positioner collision. The views through these cameras need to be clear enough for the operators to safely conduct these tasks. One of the products of the experiments conducted in the target chamber are neutrons. These neutrons expand outward from the center of the target chamber with great energy. If the neutrons hit the sensor chip on a digital camera they will “kill” the sensor pixel where they contact, and the result will be a permanently bright white pixel on the image. Over time these “dead” pixels will build up and make the camera less and less usable providing a “staticky” image. The current solution of replacing the cameras when they become damaged is unsustainable due to both the cameras being out of production and the increased rate of camera failure based upon the increased number and energy of neutrons being generated. Current supplies of the correct camera type are dwindling with no source of replacement and the projected rate of replacement is unsustainable. Without a redesign, the function provided by the current CIVS system will be lost.

42 ENGINEERING↗

Vehicular Re-Identification from Uncontrolled Multiple Views

Vehicle re-identification (re-ID) across disparate sensing modalities remains a fundamental challenge for transportation research. In this work, we introduce a deep multi-view vehicle re-ID framework that leverages Siamese networks to compare pairs of vehicle images and produce matching scores, enabling robust association across drastically different viewpoints such as those from UAVs, surveillance cameras, and ground sensors. The model exploits convolutional neural networks to learn features that remain discriminative under changes in angle, distance, and illumination, supporting more generalizable re-ID performance. As part of this effort, we also developed an automated pipeline to synchronize roadside and UAV video streams, producing a multi-perspective dataset that complements preexisting real collections and a synthetic dataset generated in this study. Together, these contributions advance the capability to re-identify vehicles across wide viewing baselines; establish a foundation for scalable, reproducible research in vehicle re-ID; and open pathways for future applications, such as inferring routine behaviors, movement patterns, and daily habits of the individual associated with the vehicle.

convolutional neural networks↗

A weak lensing view of the downsizing of star-forming galaxies

We describe a weak lensing view of the downsizing of star-forming galaxies based on cross-correlating a weak lensing (κ) map with a predicted map constructed from a redshift survey. Moderately deep and high-resolution images with Subaru/Hyper Suprime-Cam covering the 4 deg{sup 2} DLS F2 field provide a κ map with 1 arcmin resolution. A dense complete redshift survey of the F2 field including 12,705 galaxies with R⩽20.6 is the basis for construction of the predicted map. The zero-lag cross-correlation between the κ and predicted maps is significant at the 30σ level. The width of the cross-correlation peak is comparable to the angular scale of rich clusters at z∼0.3, the median depth of the redshift survey. Slices of the predicted map in δz=0.05 redshift bins enable exploration of the impact of structure as a function of redshift. The zero-lag normalized cross-correlation has significant local maxima at redshifts coinciding with known massive X-ray clusters. Even in slices where there are no known massive clusters, there is a significant signal in the cross-correlation originating from lower mass groups that trace the large-scale of the universe. Spectroscopic D{sub n}4000 measurements enable division of the sample into star-forming and quiescent populations. In regions surrounding massive clusters of galaxies, the significance of the cross-correlation with maps based on star-forming galaxies increases with redshift from 5σ at z = 0.3 to 7σ at z=0.5; the fractional contribution of the star-forming population to the total cross-correlation signal also increases with redshift. This weak lensing view is consistent with the downsizing picture of galaxy evolution established from other independent studies.

79 ASTRONOMY AND ASTROPHYSICS↗