Search NASA⌕ Search

SEARCH · Search NASA

Results for “Volume Constraint”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Clinical Decision Support - Concepts of Operation

We are entering a new era in space exploration to return to the moon and explore Mars. These ambitious goals will require significant changes to in-flight and habitat medical care due to constraints on mass, volume, power, crew time and medical evacuation capabilities. These constraints make it absolutely necessary to develop transformative solutions using new technologies. The Exploration Medical Capability (ExMC) Element of the Human Research Program (HRP) pushes the boundary of space medical systems to advance the care of astronauts on future exploration missions beyond low Earth orbit by identifying and testing next-generation medical care and crew health maintenance technologies. The Clinical Decision Support (CDS) project addresses the gap Medical-701 within the Inflight Medical Conditions risk: Enhance medical capabilities within an exploration medical system. For long-duration, deep space missions, computational and data resources will play an important role in maintaining crew health, wellness and performance where the crew will need to be more self-reliant. The aim of the CDS project is to develop and provide recommended requirements for an in-vehicle CDSS that acts as an assistant for delivering optimal health and performance and medical care during exploration missions. The CDSS is envisioned as a software-based tool that will augment a crewmembers’ knowledge, skills and abilities to assist in decision-making and crew health and performance (CHP) management thus increasing CHP systems capabilities. The human interface will be context aware and lessen the cognitive load to assimilate and use information as well as combine large disparate data sets in such a manner that provides the crew with actionable insight to decisions related to crew medical, health and performance management. Crew autonomy will be provided through a CDS that presents knowledge and data in a context aware manner to augment a crew members’ knowledge, skills and abilities during the process of observation, orientation, decisions and action. The CDS project addresses the need for crew members to operate independently during long duration space exploration missions that require medical Levels of Care (LoC) V, the highest level specified by NASA-STD-3001 and described in more detail by the ExMC interpretation of LoC document (NASA/TM-2017-219290), where significant changes to in-flight and habitat medical care necessitate increasing crew autonomy in decision making and task performance. The CDS project will develop and test a series of iterative and increasingly more complex system prototypes. These annual demonstrations of the data system integration with the crew health and performance domain will inform exploration medical system requirements for an on-board Clinical Decision Support System (CDSS) through a series of use cases that guide CDS prototype functionality. CDS concepts are based on ExMC Concept of Operations documents (presented separately) and will highlight architecture extensibility to other more complex analyses and tests using core crew health and performance integrated data management, processing and visualization capabilities. This approach also establishes how externally developed analyses and approaches could be added to expand a clinical decision support system and thus highlight how a comprehensive system can be commercially and/or globally developed. The CDS project will build upon the concept of an integrated data management approach based on the Medical Data Architecture (MDA) project to more fully address challenges associated with in-flight and habitat medical, health and performance care due to constraints on mass, volume, power, crew time and medical evacuation capabilities required for medical LoC V. These requirements will be derived through systems engineering approaches and software prototype developments over the course of the multi-year CDS project to address crew health and performance decision-making and task performance, often autonomously executed by the crew, in a manner that is consistent with the appropriate medical level of care for the mission. This presentation will provide an overview of the vision for the CDS project and highlight the initial accomplishments in project planning, implementation and requirements identification in fiscal year 2020.

clinical decision support↗

Clinical Decision Support - Overview and Update

We are entering a new era in space exploration to return to the moon and explore Mars. These ambitious goals will require significant changes to in-flight and habitat medical care due to constraints on mass, volume, power, crew time and medical evacuation capabilities. These constraints make it absolutely necessary to develop transformative solutions using new technologies. The Exploration Medical Capability (ExMC) Element of the Human Research Program (HRP) pushes the boundary of space medical systems to advance the care of astronauts on future exploration missions beyond low Earth orbit by identifying and testing next-generation medical care and crew health maintenance technologies. The Clinical Decision Support (CDS) project addresses the gap Medical-701 within the Inflight Medical Conditions risk: Enhance medical capabilities within an exploration medical system. For long-duration, deep space missions, computational and data resources will play an important role in maintaining crew health, wellness and performance where the crew will need to be more self-reliant. The aim of the CDS project is to develop and provide recommended requirements for an in-vehicle CDSS that acts as an assistant for delivering optimal health and performance and medical care during exploration missions. The CDSS is envisioned as a software-based tool that will augment a crewmembers’ knowledge, skills and abilities to assist in decision-making and crew health and performance (CHP) management thus increasing CHP systems capabilities. The human interface will be context aware and lessen the cognitive load to assimilate and use information as well as combine large disparate data sets in such a manner that provides the crew with actionable insight to decisions related to crew medical, health and performance management. Crew autonomy will be provided through a CDS that presents knowledge and data in a context aware manner to augment a crew members’ knowledge, skills and abilities during the process of observation, orientation, decisions and action. The CDS project addresses the need for crew members to operate independently during long duration space exploration missions that require medical Levels of Care (LoC) V, the highest level specified by NASA-STD-3001 and described in more detail by the ExMC interpretation of LoC document (NASA/TM-2017-219290), where significant changes to in-flight and habitat medical care necessitate increasing crew autonomy in decision making and task performance. The CDS project will develop and test a series of iterative and increasingly more complex system prototypes. These annual demonstrations of the data system integration with the crew health and performance domain will inform exploration medical system requirements for an on-board Clinical Decision Support System (CDSS) through a series of use cases that guide CDS prototype functionality. CDS concepts are based on ExMC Concept of Operations documents (presented separately) and will highlight architecture extensibility to other more complex analyses and tests using core crew health and performance integrated data management, processing and visualization capabilities. This approach also establishes how externally developed analyses and approaches could be added to expand a clinical decision support system and thus highlight how a comprehensive system can be commercially and/or globally developed. The CDS project will build upon the concept of an integrated data management approach based on the Medical Data Architecture (MDA) project to more fully address challenges associated with in-flight and habitat medical, health and performance care due to constraints on mass, volume, power, crew time and medical evacuation capabilities required for medical LoC V. These requirements will be derived through systems engineering approaches and software prototype developments over the course of the multi-year CDS project to address crew health and performance decision-making and task performance, often autonomously executed by the crew, in a manner that is consistent with the appropriate medical level of care for the mission. This presentation will provide an overview of the vision for the CDS project and highlight the initial accomplishments in project planning, implementation and requirements identification in fiscal year 2020.

clinical decision support system↗

SU-F-T-501: Dosimetric Comparison of Single Arc-Per-Beam and Two Arc-Per-Beam VMAT Optimization in the Monaco Treatment Planning System

Purpose: The purpose of this study was to evaluate the dosimetric and practical effects of the Monaco treatment planning system “max arcs-per-beam” optimization parameter in pelvic radiotherapy treatments. Methods: A total of 17 previously treated patients were selected for this study with a range of pelvic disease site including prostate(9), bladder(1), uterus(3), rectum(3), and cervix(1). For each patient, two plans were generated, one using a arc-per-beam setting of ‘1’ and another with setting of ‘2’. The setting allows the optimizer to add a gantry direction change, creating multiple arc passes per beam sequence. Volumes and constraints established from the initial clinical treatments were used for planning. All constraints and dose coverage objects were kept the same between plans, and all plans were normalized to 99.7% to ensure 100% of the PTV received 95% of the prescription dose. We evaluated the PTV conformity index, homogeneity index, total monitor units, number of control points, and various dose volume histogram (DVH) points for statistical comparison (alpha=0.05). Results: We found for the 10 complex shaped target volumes (small central volumes with extending bilateral ‘arms’ to cover nodal regions) that the use of 2 arcs-per-beam achieved significantly lower average DVH values for the bladder V20 (p=0.036) and rectum V30 (p=0.001) while still meeting the high dose target constraints. DVH values for the simpler, more spherical PTVs were not found significantly different. Additionally, we found a beam delivery time reduction of approximately 25%. Conclusion: In summary, the dosimetric benefit, while moderate, was improved over a 1 arc-per-beam setting for complex PTVs, and equivalent in other cases. The overall reduced delivery time suggests that the use of multiple arcs-per-beam could lead to reduced patient on table time, increased clinical throughput, and reduced medical physics quality assurance effort.

60 APPLIED LIFE SCIENCES↗

MRI-Guided 3D Optimization Significantly Improves DVH Parameters of Pulsed-Dose-Rate Brachytherapy in Locally Advanced Cervical Cancer

Purpose: To compare dose-volume histogram parameters of standard Point A and magnetic resonance imaging-based three-dimensional optimized dose plans in 21 consecutive patients who underwent pulsed-dose-rate brachytherapy (PDR-BT) for locally advanced cervical cancer. Methods and Materials: All patients received external beam radiotherapy (elective target dose, 45 Gy in 25-30 fractions; tumor target dose, 50-60 Gy in 25-30 fractions). PDR-BT was applied with a tandem-ring applicator. Additional ring-guided titanium needles were used in 4 patients and a multichannel vaginal cylinder in 2 patients. Dose planning was done using 1.5 Tesla T{sub 1}-weighted and T{sub 2}-weighted paratransversal magnetic resonance imaging scans. T{sub 1}-weighted visible oil-containing tubes were used for applicator reconstruction. The prescribed standard dose for PDR-BT was 10 Gy (1 Gy/pulse, 1 pulse/h) for two to three fractions to reach a physical dose of 80 Gy to Point A. The total dose (external beam radiotherapy plus brachytherapy) was normalized to an equivalent dose in 2-Gy fractions using {alpha}/{beta} = 10 Gy for tumor, {alpha}/{beta} = 3 Gy for normal tissue, and a repair half-time of 1.5 h. The goal of optimization was dose received by 90% of the target volume (D{sub 90}) of {>=}85 Gy{sub {alpha}}{sub /{beta}}{sub 10} in the high-risk clinical target volume (cervix and remaining tumor at brachytherapy), but keeping the minimal dose to 2 cm{sup 3} of the bladder and rectum/sigmoid at <90 and <75 Gy{sub {alpha}}{sub /{beta}}{sub 3}, respectively. Results: Using three-dimensional optimization, all dose-volume histogram constraints were met in 16 of 21 patients compared with 3 of 21 patients with two-dimensional library plans (p < 0.001). Optimization increased the minimal target dose (D{sub 100}) of the high-risk clinical target volume (p < 0.007) and decreased the minimal dose to 2 cm{sup 3} for the sigmoid significantly (p = 0.03). For the high-risk clinical target volume, D{sub 90} was 91 {+-} 8 Gy{sub {alpha}}{sub /{beta}}{sub 10} and D{sub 100} was 76 {+-} 5 Gy{sub {alpha}}{sub /{beta}}{sub 10}. The minimal dose to 2 cm{sup 3} for the bladder, rectum, and sigmoid was 73 {+-} 6, 67 {+-} 6, and 69 {+-} 6 Gy{sub {alpha}}{sub /{beta}}{sub 3}, respectively. Conclusion: The results of our study have shown that magnetic resonance imaging-guided optimization of PDR-BT for locally advanced cervical cancer significantly improved the dose-volume histogram parameters.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantifying mass flows at Mt. Cleveland, Alaska between 2001 and 2020 using satellite photogrammetry

Measuring eruption volume provides constraints on the magma supply rate and plumbing systems and therefore is a critical component for monitoring volcanoes. We use ArcticDEM—a large collection of time-dependent digital elevation models (DEMs) derived from satellite stereo-photogrammetry — to construct a first-of-its-kind measurement of the volumes of recent mass flows at Mount Cleveland, Alaska. We quantify the volume of the products of the 2001 eruption (the largest in the past half-century) as (54.8 ± 0.5) × 10 -6 m -3 covering a total area of 5.09 km -2 . The total volume of material loss at the summit crater is (0.67 ± 0.02) × 10 -6 m -3 , which is likely caused by later explosions and collapses of the shallow magma chamber. The total eruptive volume between 2017 and 2020 is (0.086 ± 0.002) × 10 -6 m -3 . Elevation changes associated with lahars are variable. On the upper northern slopes of the volcano, the lahar channels were almost exclusively erosive, suggesting that lahars originating at the summit eroded and entrained loose materials high on the cone. In general, lahar deposits were thickest near their toes, with some reaching ~20 m thickness.

Chunli Dai↗

WE-D-BRE-03: Late Toxicity Following Photon Or Proton Radiotherapy in Patients with Brain Tumors

Purpose: To identify indicators of Late Grade 3 (LG3) toxicity, late vision and hearing changes in patients treated for primary brain tumors with photon (XRT) or proton radiotherapy (PRT). Methods: We retrospectively reviewed 102 patients who received brain XRT or PRT to doses of 54 or 59.6 Gy in daily fractions of 1.8–2 Gy. Of the 80 patients (34 XRT, 39 PRT and 7 both modalities) reviewed for indicators of LG3 toxicity, 25 developed LG3 toxicity 90 to 500 days after radiotherapy completion. 55 patients had less than LG3 toxicity > 500 days after treatment. In that time, late vision and hearing changes were seen in 44 of 75 and 25 of 78 patients, respectively. The correlation between late toxicity and prescription dose, planning target volume (PTV) size, and doses to the brainstem, brain, optic chiasm, optic nerves, eyes and cochlea was evaluated. A two-tailed Fisher's exact test and Wilcoxon rank sum test were used for the statistical analysis for XRT, PRT and all patients combined. Results: Exceeding the 54 Gy-5% dose-volume brainstem constraint, but not the optic structure constraints, was significantly correlated (p < 0.05) with late vision changes in all three groups. Exceeding maximum and mean cochlear doses of 45 and 30 Gy, respectively, was a significant indicator of hearing changes (p < 0.05) in PRT patients and all patients combined. In a sub-group of 52 patients in whom the brain was contoured, the absolute brain volume receiving ≤ 50 Gy and > 60 Gy was significantly larger in patients with LG3 toxicity for all patients combined (p < 0.05). Prescription dose, brainstem dose and PTV volume were not correlated to LG3 toxicity. Conclusion: Our results indicate the importance of minimizing the brain volume irradiated, and brainstem and cochlea doses to reduce the risk of late toxicities following brain radiotherapy.

60 APPLIED LIFE SCIENCES↗

Nonlinear registration of serial coronary CT angiography (CCTA) for assessment of changes in atherosclerotic plaque

Purpose: Coronary CT angiography (CCTA) is a high-resolution three-dimensional imaging technique for the evaluation of coronary arteries in suspected or confirmed coronary artery disease (CAD). Coregistration of serial CCTA scans would allow precise superimposition of images obtained at two different points in time, which could aid in recognition of subtle changes and precise monitoring of coronary plaque progression or regression. To this end, the authors aimed at developing a fully automatic nonlinear volume coregistration for longitudinal CCTA scan pairs. Methods: The algorithm combines global displacement and local deformation using nonlinear volume coregistration with a volume-preserving constraint. Histogram matching of intensities between two serial scans is performed prior to nonlinear coregistration with dense nonparametric local deformation in which sum of squared differences is used as a similarity measure. The approximate segmentation of coronary arteries obtained from commercially available software provides initial anatomical landmarks for the coregistration algorithm that help localize and emphasize the structure of interest. To avoid possible bias caused by incorrect segmentation, the authors convolve the Gaussian kernel with the segmented binary coronary tree mask and define an extended weighted region of interest. A multiresolution approach is employed to represent coarse-to-fine details of both volumes and the energy function is optimized using a gradient descent method. The authors applied the algorithm in ten paired CCTA datasets (20 scans in total) obtained within 10.7{+-}5.7 months from each other on a dual source CT scanner to monitor progression of CAD. Results: Serial CCTA coregistration was successful in 9/10 cases as visually confirmed. The global displacement and local deformation of target registration error obtained from four anatomical landmarks were 2.22{+-}1.15 and 1.56{+-}0.74 mm, respectively, and the inverse consistency error of local deformation was 0.14{+-}0.06 mm. The observer variability between two expert observers was 1.31{+-}0.91 mm. Conclusions: The proposed coregistration algorithm demonstrates potential to accurately register serial CCTA scans, which may allow direct comparison of calcified and noncalcified atherosclerotic plaque changes between the two scans.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-535: Preliminary 2D and 3D Gamma Calculation Comparison Using PRESAGE

Purpose: To compare gamma calculations from 2D and 3D dosimetry measurements for phantom quality assurance. Methods: An IROC Houston (RPC) head and neck phantom was irradiated with a 9 beam IMRT plan using two inserts: a TLD and film insert and a PRESAGE insert. Both inserts were irradiated 3 times. The film and PRESAGE doses were scaled to the TLD dose and 2D gamma calculations were made in the axial and sagittal planes bisecting the primary target. 3D gamma measurements were taken within the PRESAGE dosimeter volume. Gamma constraints of 3%/3mm distance to agreement (DTA), 5%/3mm DTA and 7%/4mm DTA were used in the study. The 3 irradiations for each insert were averaged together for comparison. Results: Film measurements for the 2D gamma showed 85% pixels passing at 3%/3mm in both planes. The 5%/3 mm constraint had 93% and 90% passing in the two planes. The 7%/4mm restraint resulted in 99% passing in both planes. The PRESAGE 2D gamma passed 66% and 61% of pixels in the both planes at 3%/3mm. At 5%/3mm 86% and 82% passed. For 7%/4mm, 94% of pixels passed in both planes. The 3D gamma resulted in a pass rate of 90% at 3%/3mm, 95% at 5%/3mm, and 99% at 7%/4mm. Conclusion: 2D gamma pass rates using film showed a higher pass rate than PRESAGE using the same criteria in the same planes. This may be due to poor 3D registration with the treatment plan compared to the 2D film registration system. The 3D gamma results had a higher pass rate (> 90% pass rate) possibly because it sampled many more pixels in noncritical volumes thus diluting the percent of pixels passing. 3D restraints should be more restrictive to be comparable to 2D results. Funding from NIH grant 5R01CA100835.

60 APPLIED LIFE SCIENCES↗

Comparison of fixed-beam IMRT, helical tomotherapy, and IMPT for selected cases

A growing number of advanced intensity modulated treatment techniques is becoming available. In this study, the specific strengths and weaknesses of four techniques, static and dynamic multileaf collimator (MLC), conventional linac-based IMRT, helical tomotherapy (HT), and spot-scanning proton therapy (IMPT) are investigated in the framework of biological, EUD-based dose optimization. All techniques were implemented in the same in-house dose optimization tool. Monte Carlo dose computation was used in all cases. All dose-limiting, normal tissue objectives were treated as hard constraints so as to facilitate comparability. Five patient cases were selected to offer each technique a chance to show its strengths: a deep-seated prostate case (for 15 MV linac-based IMRT), a pediatric case (for IMPT), an extensive head-and-neck case (for HT), a lung tumor (for HT), and an optical neurinoma (for noncoplanar linac-based IMRT with a miniMLC). The plans were compared by dose statistics and equivalent uniform dose metrics. All techniques delivered results that were comparable with respect to target coverage and the most dose-limiting normal tissues. Static MLC IMRT struggled to achieve sufficient target coverage at the same level of dose homogeneity in the lung case. IMPT gained the greatest advantage when lung sparing was important, but did not significantly reduce the risk of nearby organs. Tomotherapy and dynamic MLC IMRT showed mostly the same performance. Despite the apparent conceptual differences, all four techniques fare equally well for standard patient cases. The absence of relevant differences is in part due to biological optimization, which offers more freedom to shape the dose than do, e.g., dose volume histogram constraints. Each technique excels for certain classes of highly complex cases, and hence the various modalities should be viewed as complementary, rather than competing.

61 RADIATION PROTECTION AND DOSIMETRY↗

Spatiotemporal 4D Whole-cell Modeling of a Minimal Autotroph Reveals Central Carbon Metabolism Regulated Locally by Protein Megacomplexes via Post-translational Modifications under Light Disturbance

Photosynthetic microorganisms rely on multiple pathways in central carbon metabolism to adapt to fluctuating light and energy availability across diel cycles. Mechanistic insight into the regulatory dynamics of this adaptation requires integrating processes spanning disparate timescales, from rapid redox-dependent post-translational modifications (PTMs) to slower changes in protein expression and metabolic pathway usage. To address this complexity beyond genome-based inference and traditional modeling, we develop a whole-cell four-dimensional (3D + time) model of the marine cyanobacterium Prochlorococcus marinus MED4 that explicitly represents the spatial organization of enzymatic and molecular processes in central carbon metabolism under light perturbation. We employ a perturbation-based research design to experimentally generate time-series, multi-omics measurements that provide molecular descriptors and cryo-ET derived 3D segmented volumes as constraints for this dynamic 4D framework. The integration of experiments and modeling across defined light regimes enables quantitative validation of system-level responses and forecasting under distinct light disturbances. We test the hypothesis that light-dependent redox PTMs regulating the structural assembly of a protein megacomplex, the “dark complex,” modulate metabolic flux at a conserved regulatory node of the Calvin–Benson cycle (CBC) in cyanobacteria. Our model shows that subcellular spatial organization buffers rapid light-induced changes in thylakoid reaction rates, which are followed by redox-PTM-mediated sequestration or release of CBC enzymes in the dark complex, ultimately impacting carbon fixation dynamics within carboxysomes. Comparison with an equivalently parameterized well-mixed stochastic model demonstrates that post-translational regulation not only buffers transcriptional noise and diffusion-driven fluctuations but also stabilizes phenotypic outcomes, underscoring the importance of spatial heterogeneity in phenotypic robustness. This ability to probe adaptive, spatiotemporally resolved mechanisms in photosynthetic machinery and central carbon metabolism addresses a critical gap in genotype-to-phenotype inference and expands modeling and design capabilities for understudied or genetically intractable autotrophs such as P. marinus MED4.

Johnson, Connah G.↗

RTOG GU Radiation Oncology Specialists Reach Consensus on Pelvic Lymph Node Volumes for High-Risk Prostate Cancer

Purpose: Radiation therapy to the pelvic lymph nodes in high-risk prostate cancer is required on several Radiation Therapy Oncology Group (RTOG) clinical trials. Based on a prior lymph node contouring project, we have shown significant disagreement in the definition of pelvic lymph node volumes among genitourinary radiation oncology specialists involved in developing and executing current RTOG trials. Materials and Methods: A consensus meeting was held on October 3, 2007, to reach agreement on pelvic lymph node volumes. Data were presented to address the lymph node drainage of the prostate. Extensive discussion ensued to develop clinical target volume (CTV) pelvic lymph node consensus. Results: Consensus was obtained resulting in computed tomography image-based pelvic lymph node CTVs. Based on this consensus, the pelvic lymph node volumes to be irradiated include: distal common iliac, presacral lymph nodes (S{sub 1}-S{sub 3}), external iliac lymph nodes, internal iliac lymph nodes, and obturator lymph nodes. Lymph node CTVs include the vessels (artery and vein) and a 7-mm radial margin being careful to 'carve out' bowel, bladder, bone, and muscle. Volumes begin at the L5/S1 interspace and end at the superior aspect of the pubic bone. Consensus on dose-volume histogram constraints for OARs was also attained. Conclusions: Consensus on pelvic lymph node CTVs for radiation therapy to address high-risk prostate cancer was attained and is available as web-based computed tomography images as well as a descriptive format through the RTOG. This will allow for uniformity in evaluating the benefit and risk of such treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Modeling Plan-Related Clinical Complications Using Machine Learning Tools in a Multiplan IMRT Framework

Purpose: To predict organ-at-risk (OAR) complications as a function of dose-volume (DV) constraint settings without explicit plan computation in a multiplan intensity-modulated radiotherapy (IMRT) framework. Methods and Materials: Several plans were generated by varying the DV constraints (input features) on the OARs (multiplan framework), and the DV levels achieved by the OARs in the plans (plan properties) were modeled as a function of the imposed DV constraint settings. OAR complications were then predicted for each of the plans by using the imposed DV constraints alone (features) or in combination with modeled DV levels (plan properties) as input to machine learning (ML) algorithms. These ML approaches were used to model two OAR complications after head-and-neck and prostate IMRT: xerostomia, and Grade 2 rectal bleeding. Two-fold cross-validation was used for model verification and mean errors are reported. Results: Errors for modeling the achieved DV values as a function of constraint settings were 0-6%. In the head-and-neck case, the mean absolute prediction error of the saliva flow rate normalized to the pretreatment saliva flow rate was 0.42% with a 95% confidence interval of (0.41-0.43%). In the prostate case, an average prediction accuracy of 97.04% with a 95% confidence interval of (96.67-97.41%) was achieved for Grade 2 rectal bleeding complications. Conclusions: ML can be used for predicting OAR complications during treatment planning allowing for alternative DV constraint settings to be assessed within the planning framework.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A meshless Galerkin method for non-local diffusion using localized kernel bases

Here, we introduce a meshless method for solving both continuous and discrete variational formulations of a volume constrained, nonlocal diffusion problem. We use the discrete solution to approximate the continuous solution. Our method is nonconforming and uses a localized Lagrange basis that is constructed out of radial basis functions. By verifying that certain inf-sup conditions hold, we demonstrate that both the continuous and discrete problems are well-posed, and also present numerical and theoretical results for the convergence behavior of the method. The stiffness matrix is assembled by a special quadrature routine unique to the localized basis. Combining the quadrature method with the localized basis produces a well-conditioned, symmetric matrix. This then is used to find the discretized solution.

97 MATHEMATICS AND COMPUTING↗

Transformations based on continuous piecewise-affine velocity fields

Here, we propose novel finite-dimensional spaces of well-behaved Rn → Rn transformations. The latter are obtained by (fast and highly-accurate) integration of continuous piecewise-affine velocity fields. The proposed method is simple yet highly expressive, effortlessly handles optional constraints (e.g., volume preservation and/or boundary conditions), and supports convenient modeling choices such as smoothing priors and coarse-to-fine analysis. Importantly, the proposed approach, partly due to its rapid likelihood evaluations and partly due to its other properties, facilitates tractable inference over rich transformation spaces, including using Markov-Chain Monte-Carlo methods. Its applications include, but are not limited to: monotonic regression (more generally, optimization over monotonic functions); modeling cumulative distribution functions or histograms; time-warping; image warping; image registration; real-time diffeomorphic image editing; data augmentation for image classifiers. Our GPU-based code is publicly available.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-E-J-193: Feasibility of MRI-Only Based IMRT Planning for Pancreatic Cancer

Purpose: With the increasing use of MRI simulation and the advent of MRI-guided delivery, it is desirable to use MRI only for treatment planning. In this study, we assess the dosimetric difference between MRI- and CTbased IMRT planning for pancreatic cancer. Methods: Planning CTs and MRIs acquired for a representative pancreatic cancer patient were used. MRI-based planning utilized forced relative electron density (rED) assignment of organ specific values from IRCU report 46, where rED = 1.029 for PTV and a rED = 1.036 for non-specified tissue (NST). Six IMRT plans were generated with clinical dose-volume (DV) constraints using a research Monaco planning system employing Monte Carlo dose calculation with optional perpendicular magnetic field (MF) of 1.5T. The following five plans were generated and compared with the planning CT: 1.) CT plan with MF and dose recalculation without optimization; 2.) MRI (T2) plan with target and OARs redrawn based on MRI, forced rED, no MF, and recalculation without optimization; 3.) Similar as in 2 but with MF; 4.) MRI plan with MF but without optimization; and 5.) Similar as in 4 but with optimization. Results: Generally, noticeable differences in PTV point doses and DV parameters (DVPs) between the CT-and MRI-based plans with and without the MF were observed. These differences between the optimized plans were generally small, mostly within 2%. Larger differences were observed in point doses and mean doses for certain OARs between the CT and MRI plan, mostly due to differences between image acquisition times. Conclusion: MRI only based IMRT planning for pancreatic cancer is feasible. The differences observed between the optimized CT and MRI plans with or without the MF were practically negligible if excluding the differences between MRI and CT defined structures.

60 APPLIED LIFE SCIENCES↗

SU-E-T-514: Investigating the Dose Distributions of Equiangular Spaced Noncoplanar Beams

Purpose It has been demonstrated that the use of noncoplanar beams in radiation therapy may Result in dose distributions that are comparable or better than standard coplanar beams [Pugachev, 2001]. A radiation therapy system designed with a noncoplanar beam geometry could allow for a full ring diagnostic quality imaging system to be placed around the patient. Additionally, if the noncoplanar beams were fixed in number and in their angle with respect to the patient’s axial plane, then both treatment and imaging could be achieved concurrently without the need for moving parts, which could greatly reduce treatment times. For such a system to be designed, it is necessary to determine the appropriate number of beams and the beam angles to achieve optimal dose distributions. For simplicity, the beam angles are assumed to be equiangular in the patient’s axial plane, and only the beam angle with respect to the axial plane are varied. This study aims to investigate the dose distributions produced by equiangular noncoplanar beams for multiple beam numbers and beam angles, and to compare these dose distributions with distributions achieved in coplanar volumetric arc therapy (VMAT). Methods Dose distributions produced by noncoplanar beams were calculated using the Varian Eclipse treatment planning system by varying the gantry, collimator, and couch angles to simulate the noncoplanar delivery method. Noncoplanar intensity-modulated (NC-IMRT) beams using 8, 12, and 16 beams with angles varying from 45 degrees to 54 with respect to the patient’s axial plane were studied. Results The NC-IMRT beams produced dose distributions comparable to VMAT plans for a number of treatment sites, and were capable of meeting similar dose-volume histogram constraints. Conclusion This study has demonstrated that a noncoplanar beam delivery method with fixed beam numbers and beam angles is capable of delivering dose distributions comparable to VMAT plans currently in use.

60 APPLIED LIFE SCIENCES↗

SU-F-BRD-12: When Does Pencil Beam Scanning Become Superior to Passive Scattered Proton Therapy for Pediatric Head and Neck Cancers?

Purpose: To investigate the dosimetric benefits of pencil beam scanning (PBS) compared with passive scattered (PS) proton therapy for treatment of pediatric head&neck patients as a function of the PBS spot size and explore the advantages of using apertures in PBS. Methods: Ten pediatric patients with head&neck cancers treated by PS proton therapy at our institution were retrospectively selected. The histologies included rhabdomyosarcoma, ependymoma, astrocytoma, craniopharyngioma and germinoma. The prescribed dose ranged from 36 to 54 Gy(RBE). Five PBS plans were created for each patient using variable spot size (average sigma at isocenter) and choice of beam specific apertures: (1) 10mm spots, (2) 10mm spots with apertures, (3) 6mm spots, (4) 6mm spots with apertures, and (5) 3mm spots. The plans were optimized for intensity modulated proton therapy (IMPT) with no single beam uniformity constraints. Dose volume indices as well as equivalent uniform dose (EUD) were compared between PS and PBS plans. Results: Although target coverage was clinically adequate for all cases, the plans with largest (10mm) spots provide inferior quality compared with PS in terms of dose to organs-at-risk (OAR). However, adding apertures to these plans ensured lower OAR dose than PS. The average EUD difference between PBS and PS plans over all patients and organs at risk were (1) 2.5%, (2) −5.1%, (3) -5%, (4) −7.8%, and (5) −9.5%. As the spot size decreased, more conformal plans were achieved that offered similar target coverage but lower dose to the neighboring healthy organs, while alleviating the need for using apertures. Conclusion: The application of PBS does not always translate to better plan qualities compared to PS depending on the available beam spot size. We recommend that institutions with spot size larger than ∼6mm at isocenter consider using apertures to guarantee clinically comparable or superior dosimetric efficacy to PS treatments.

60 APPLIED LIFE SCIENCES↗