Search NASA⌕ Search

SEARCH · Search NASA

Results for “WORK CAPACITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Human Performance Improvement Task Group Task 21-1 Best Practice: Using virtual capabilities or options for HPI application (to reduce errors, strengthening defenses, strengthening the organization, and/or increasing capacity)

In 2020 the world was impacted by COVID-19. How work is done was dramatically changed for a large portion of the workforce. Many have made the abrupt shift to working from their home while others have adapted to COVID protocols (such as social distancing and wearing facemasks). Fundamentally, Human and Organizational Performance Improvement concepts and science did not change – only the delivery method changed (in some cases). The primary effect has been to accelerate dynamics already present in society – from e-commerce to online education to remote healthcare. Change is never easy for humans. However, remote work should be viewed as an opportunity; not a fix to a problem. In this Best Practice paper, you’ll get practical suggestions to help you reduce errors and improve Human Performance in remote, socially-distanced “work-from-home” environments.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Amorphous zinc–molybdenum–sulfide chalcogel as a long-cycle, high-capacity electrode for lithium-ion batteries

The inherent limitations of intercalation-based electrodes in lithium-ion batteries have prompted the search for alternative materials with higher specific capacities and robust electrochemical stability. Sulfur-based electrodes, despite their high theoretical capacities (1672 mAh g −1 ), typically suffer from poor cycling performance. In this work, zinc molybdenum polysulfide (Zn x Mo 3 S 13 , 0.5 ≤ x), an amorphous semiconductor chalcogel, exhibits high specific capacity and excellent cycling stability. Synchrotron X-ray pair distribution function and extended X-ray absorption fine structure analyses reveal a short-range atomic structure comprising Mo–Mo, M–S (M = Mo, Zn), and S–S bonding motifs. The coordination environment of Mo and S closely resembles that of Mo 3 S 13 clusters, interconnected via S–S bridges and Zn 2+ cations. The Li/Zn x Mo 3 S 13 cell delivers an initial discharge capacity of 844 mAh g −1 at C/3, and retains 386.2 mAh g −1 after 1000 cycles with an average coulombic efficiency of 99.99%. The distribution of relaxation times analysis confirms the formation of a stable solid electrolyte interphase, which underpins the cell's long-term stability. In conclusion, this outstanding performance is attributed to the synergistic effects of the chalcogel's unique amorphous framework, semiconductive character, Zn-mediated polysulfide anchoring, and structural resilience, positioning Zn x Mo 3 S 13 chalcogel among the most durable pure metal sulfide cathodes reported for next-generation LIBs.

36 MATERIALS SCIENCE↗

Development of a Structure for Lossless Ion Manipulations (SLIM) High Charge Capacity Array of Traps

Enhancing the sensitivity of low abundance ions in a complex mixture without sacrificing experiment throughput is highly desirable. This work demonstrates a way to greatly improve the sensitivity of ion mobility (IM) selected ions by accumulating them in an array of high-capacity ion traps located inside a novel structures for lossless ion manipulations ion mobility spectrometer (SLIM-IMS) module. The array of ion traps used in this work consisted of seven independently controllable traps. Each trap was 386 mm long and possessed a charge capacity of ~4.5×10 8 charges, with a linear range extending to ~2.5×10 8 charges. Each ion trap could be used to extract a peak (or ions over a mobility range) from an ion mobility separation based on arrival time. Ions could be stored without losses for long times (>100 s) and then released all at once or one trap at a time. It was possible to accumulate large ion populations by extracting and storing ions over repeated IM separations. We report enrichment of up to seven individual ion distributions could be performed using the seven independently controllable ion traps. Additionally, the ion trapping process effectively compressed ion populations into narrow peaks, which provides a greatly improved basis for subsequent ion manipulations. The array of high charge-capacity ion traps provides a flexible addition to SLIM and a powerful tool for IMS-MS applications requiring high sensitivity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fluoride-Rich, Organic–Inorganic Gradient Interphase Enabled by Sacrificial Solvation Shells for Reversible Zinc Metal Batteries

Zinc metal batteries are strongly hindered by water corrosion, as solvated zinc ions would bring the active water molecules to the electrode/electrolyte interface constantly. Herein, we report a sacrificial solvation shell to repel active water molecules from the electrode/electrolyte interface and assist in forming a fluoride-rich, organic-inorganic gradient solid electrolyte interface (SEI) layer. Additionally, the simultaneous sacrificial process of methanol and Zn(CF 3 SO 3 ) 2 results in the gradient SEI layer with an organic-rich surface (CH 2 OC- and C 5 product) and an inorganic-rich (ZnF 2 ) bottom, which combines the merits of fast ion diffusion and high flexibility. As a result, the methanol additive enables corrosion-free zinc stripping/plating on copper foils for 300 cycles with an average coulombic efficiency of 99.5%, a record high cumulative plating capacity of 10 A h/cm 2 at 40 mA/cm 2 in Zn/Zn symmetrical batteries. More importantly, at an ultralow N/P ratio of 2, the practical VO 2 //20 mu m thick Zn plate full batteries with a high areal capacity of 4.7 mAh/cm 2 stably operate for over 250 cycles, establishing their promising application for grid-scale energy storage devices. Furthermore, directly utilizing the 20 μm thick Zn for the commercial-level areal capacity (4.7 mAh/cm 2 ) full zinc battery in our work would simplify the manufacturing process and boost the development of the commercial zinc battery for stationary storage.

25 ENERGY STORAGE↗

Selective Pb 2+ removal and electrochemical regeneration of fresh and recycled FeOOH

Heavy metal pollution is a key environmental problem. Selectively extracting heavy metals could accomplish water purification and resource recycling simultaneously. Adsorption is a promising approach with a facile process, adaptability for the broad concentration of feed water, and high selectivity. However, the adsorption method faces challenges in synthesizing high-performance sorbents and regenerating adsorbents effectively. FeOOH is an environmentally friendly sorbent with low-cost production on a large scale. Nevertheless, the selectivity behavior and regeneration of FeOOH are seldom studied. Therefore, we investigated the selectivity of FeOOH in a mixed solution of Co 2+ , Ni 2+ , and Pb 2+ and proposed to enhance the capacity of FeOOH and regenerate it by using external charges. Without charge, the FeOOH electrode shows a Pb 2+ uptake capacity of 20 mg/g. After applying a voltage of –0.2/+0.8 V, the uptake capacity increases to a maximum of 42 mg/g and the desorption ratio is 70%–80%. In 35 cycles, FeOOH shows a superior selectivity towards Pb 2+ compared with Co 2+ and Ni 2+ , with a purity of 97% ± 3% in the extracts. The high selectivity is attributed to the lower activation energy for Pb 2+ sorption. The capacity retentions at the 5 th and the 35 th cycles are ca. 80% and ca. 50%, respectively, comparable to the chemical regeneration method. With industrially exhausted granular ferric hydroxide as the electrode material, the system exhibits a Pb 2+ uptake capacity of 37.4 mg/g with high selectivity. Our work demonstrates the feasibility of regenerating FeOOH by charge and provides a new approach for recycling and upcycling FeOOH sorbent.

36 MATERIALS SCIENCE↗

Synthesis and characterization of UiO-66-NH 2 incorporated graphene aerogel composites and their utilization for absorption of organic liquids

This work details the synthesis, materials characterization and absorption capacity of graphene aerogel (GA) loaded with UiO-66-NH 2 metal organic framework (MOF). Throughout the study, a series of density-tunable MOF/GA composites were synthesized by adjusting the MOF/graphene oxide (GO) mass ratio of the precursors before hydrothermal reduction and subsequent critical point drying to achieve MOF-x%/GA composites, with x, ranging from 0 to 100, denoting the weight percent ratio of MOF to GO in the starting solution. Scanning electron microscopy (SEM) images and Barrett-Joyner-Halenda (BJH) pore size calculations supported that MOF loading enlarged the macroporous (>50 nm) structure of the GA framework but had no influence on the mesoporous (2–50 nm) structure of GA. The degree of MOF loading first decreased and then increased the density of resulting composites, exhibiting a minimum for the 10–30% samples. Such behavior with respect to MOF loading has not been reported previously. MOF-x%/GA samples were further investigated for absorption capacity using various organic liquids. MOF-30%/GA proved to be the best absorbent sample for all solvents tested, achieving the highest capacity for chloroform at 147.0 ± 10.0 mg/mg. The behavior is attributed to the structural changes induced by the MOF incorporation as well as the interactions between the organic molecules and the MOF.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Significant life extension of lithium-ion batteries using compact metallic lithium reservoir with passive control

Both traditional graphite-based lithium-ion batteries and next generation silicon-based chemistries suffer significant capacity fade from loss of cyclable lithium due to continued solid-electrolyte interphase growth. A possible engineering solution to maintaining the capacity of cells is incorporating a metallic lithium reservoir and discharging the reservoir into a working electrode to make up for lost cyclable lithium. Here, metallic lithium reservoirs are inserted into both pouch- and cylindrical-format cells. Significant capacity recovery and lifetime extension are demonstrated for traditional graphite and Si/graphite-based cells. In this work, a combination of post-mortem characterization and modeling provide insight into how the lithium distribution as a function of position from reservoir vary with recovery rate. The potential of using passive control to potentially eliminate the need for extra wiring for the third electrode is explored using a simple resistor.

25 ENERGY STORAGE↗

Building energy efficiency and load flexibility optimization using phase change materials under futuristic grid scenario

This work investigates the energy savings and load flexibility capacity of phase change material (PCM) integrated into building envelope under a future energy generation scenario, where 80% of the energy load comes from renewable sources. Using community-scale modeling, we first determine the net thermal storage required to fully manage the demand variability at a utility grid, and then using whole-building simulations we optimize operating parameters - such as PCM thickness, latent heat, interior setpoint profile, PCM distribution, and heat transfer coefficient - to determine the optimal conditions required for maximum energy reduction and load flexibility without compromising occupants' thermal comfort. The optimal PCM-integrated envelope proposed in this study can provide annual load flexibility up to 33.6% and annual energy savings up to 10.8% in a lightweight residential building located in Baltimore, MD. This study is relevant given the increasing contributions of renewable energy in the total energy generation mix, leading to a significant time-imbalance between peak energy demand and peak energy production. While thermal energy storage using PCM is a recognized technique, there is no known prior study dedicated to examining the thermal performance of PCM-integrated envelope under future energy generation scenarios. This study bridges the research gap by investigating a practical way to implement PCMs in the buildings and maximize the energy efficiency as well as load flexibility related benefits.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modeling assisted synthesis of Zr-doped Li 3-x In 1-x Zr x Cl 6 with ultrahigh ionic conductivity for lithium-ion batteries

All-solid-state lithium-ion batteries (ASSLBs) are an important milestone for the future of energy storage because of their capability of impressive energy density and outstanding safety. However, oxide and sulfide solid-state electrolytes (SSEs) suffer from either low ionic conductivity or poor chemical stability. In contrast, halide-based SSEs, are promising as candidate materials owing to high conductivity, good stability, and broad cathode compatibility. Though element doping of the SSEs is an effective and common approach to further improve their electrochemical properties, dopant exploration and optimization through solely experimental trials are both costly and time-consuming. For this aspect, computational simulations for dopant element and concentration screening are adopted in this research and zirconium is selected as a suitable dopant for Li 3 InCl 6 . Further, the synthesized Li 2.75 In 0.75 Zr 0.25 Cl 6 exhibited Li ionic conductivity of 5.82 x 10 -3 Scm -1 at room temperature, which is the highest among reported halide SSEs. The ASSLB formed with Li 2 CoO 2 -Li 2.75 In 0.75 Zr 0.25 Cl 6 -Li/In delivers a high initial capacity of 129.3 mAh∙g -1 . Conclusively, this work provides an effective approach which combines computational modeling and experimental verification for the development of halide SSEs with improved stability and conductivity. The successful design approach and compelling results provide further possibilities and capabilities in future SSE research.

25 ENERGY STORAGE↗

Influence of oxidizing and reducing pretreatment on the catalytic performance of CeO 2 for CO oxidation

Cerium oxide (CeO 2 ) and ceria-based materials have been extensively investigated as catalyst and support materials for various catalytic reactions, due to higher oxygen storage capacity and excellent redox properties. In the current work, we investigated the impact of pretreatment conditions (e.g., oxidation and reduction) on the physical properties of bulk CeO 2 and catalytic activity for CO oxidation as a model reaction. To understand the physical properties of pretreated CeO 2 catalysts, a suite of complementary characterization techniques, including X-ray diffraction (XRD), surface area analysis (BET), X-ray photoemission spectroscopy (XPS), and Raman spectroscopy, were applied. The results showed that a higher pretreatment temperature led to a decreased specific surface area (SSA), a decrease in oxygen vacancy/defect sites, and increased crystallite size, while surface Ce 3+ /Ce 4+ ratio did not show a specific relationship to the treatment conditions. The 700 °C treated CeO 2 samples under oxidizing and reducing conditions showed higher specific oxidation rate (μmolCO/s/m 2 ) compared to other samples at 280 and 300 °C (or < 15% CO conversion). The CO conversion per total mass of catalysts, however, decreased with increasing temperatures, especially at 700 °C under reducing condition, indicating that the catalytic performance was affected by the physical properties (SSA, oxygen vacancy/defect sites, and crystallite size).

36 MATERIALS SCIENCE↗

ACuZrQ 3 (A = Rb, Cs; Q = S, Se, Te): Direct Bandgap Semiconductors and Metals with Ultralow Thermal Conductivity

ACuZrQ 3 (A = Rb, Cs; Q = S, Se, Te) were synthesized as black platelet crystals. RbCuZrS 3 , RbCuZrSe 3 , and CsCuZrS 3 crystallize in the KCuZrSe 3 structure type with space group Cmcm, and RbCuZrTe 3 and CsCuZrTe 3 crystallize in the lower symmetry space group Pnma. The tellurides exhibit a second order Jahn-Teller distortion with off-centering of Zr in its octahedral environment. The magnitude of the distortion is larger in RbCuZrTe 3 than in CsCuZrTe 3 . The structures of beta-CsCuS 4 and Rb 2 Cu 5 Te 5 were also determined. CsCuZrS 3 melts at 910 C-circle and exhibits partial decomposition upon heating at 275 C-circle, while CsCuZrTe 3 melts incongruently. Our DFT calculations of RbCuZrQ 3 (Q = S, Se) and CsCuZrS 3 indicate direct gap semiconductors in agreement with experiments. ACuZrTe 3 (A = Rb, Cs) were calculated to be metals which was confirmed for RbCuZrTe 3 with variable temperature conductivity measurements and consistent with heat capacity measurements. Spectroscopic measurements found a bandgap and work function of 1.44(5) eV and 4.89(5) eV for RbCuZrS 3 and 0.95(5) eV and 4.67(5) eV for RbCuZrSe 3 , respectively. Finally, RbCuZrTe 3 did not exhibit an optical bandgap and has a work function of 4.64(5) eV. RbCuZrTe 3 exhibits a low thermal conductivity under 0.5 W m -1 K -1 at room temperature.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Chain-length-controllable upcycling of polyolefins to sulfate detergents

Escalating global plastic pollution and the depletion of fossil-based resources underscore the urgent need for innovative end-of-life plastic management strategies in the context of a circular economy. Thermolysis is capable of upcycling end-of-life plastics to intermediate molecules suitable for downstream conversion to eventually high-value chemicals, but tuning the molar mass distribution of the products is challenging. Here, in this study, we report a temperature-gradient thermolysis strategy for the conversion of polyethylene and polypropylene into hydrocarbons with tunable molar mass distributions. The whole thermolysis process is catalyst- and hydrogen-free. The thermolysis of polyethylene and polyethylene/polypropylene mixtures with tailored temperature gradients generated oil with an average chain length of ~C 14 . The oil featured a high concentration of synthetically useful α-olefins. Computational fluid dynamics simulations revealed that regulating the reactor wall temperature was the key to tuning the hydrocarbon distributions. Subsequent oxidation of the obtained α-olefins by sulfuric acid and neutralization by potassium hydroxide afforded sulfate detergents with excellent foaming behaviour and emulsifying capacity and low critical micelle concentration. Overall, this work provides a viable approach to producing value-added chemicals from end-of-life plastics, improving the circularity of the anthropogenic carbon cycle.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Deciphering the Conflict Between Ion and Electron Percolating Networks in Solid-State Battery Cathodes

High-energy- and power-density solid state batteries require an optimal cathode composition and microstructural arrangement of cathode active material, solid-state electrolyte, conductive carbon, and binder to simultaneously support lithium-ion transport, electron conduction, and storage capacity. The ion and electron conducting phases in solid-state cathodes counteract each other's percolating networks as their mass ratios increase or decrease relative to each other. Here, we investigate targeted mass ratio variations of argyrodite solid electrolyte and two different types of conductive carbon (particles and fibers) in composite LiNi0.8Mn0.1Co0.1O2 (NMC811) solid-state cathodes to ascertain the ionic-electronic tradeoffs in cathode performance. Through ionic and electronic conductivity measurements on composite cathodes, as well as rate-testing and cycling performance in full cells, it is shown that the conductive carbon fibers form a percolative electronic network within the composite at a lower mass ratio (3-5 wt%) than particulate carbon (>5 wt%). The threshold to achieve electronic percolation coincides with higher accessible capacity in the cathode as the active material particles become electronically connected. However, carbon loadings beyond this percolation threshold lead to increased ion transport resistance, arising from disruptions to ionic conduction pathways and degraded contact at the interface between the electrolyte and active materials. Imaging, spectroscopy, and physics-based models quantitatively describe the relationship between carbon and electrolyte compositions and the cell's capacity and rate performance through percolation theory. This work demonstrates the importance of quantitatively understanding percolating networks in solid-state cells and that strategic engineering of conductive carbon morphologies can further increase the energy- and power-density of solid-state cells.

25 ENERGY STORAGE↗

Multichannel gas-uptake/evolution reactor for monitoring liquid-phase chemical reactions

The design of a headspace pressure-monitoring reactor for measuring the uptake/evolution of gas in gas–liquid chemical transformations is described. The reactor features a parallel setup with ten-reactor cells, each featuring a low working volume of 0.2–2 ml, a pressure capacity from 0 to 150 PSIa, and a high sensitivity pressure transducer. The reactor cells are composed of commercially available disposable thickwalled glassware and compact monolithic weld assemblies. The software interface controls the reactor temperature while monitoring pressure in each of the parallel reactor cells. Reactions are easy to set up and yield high-density gas uptake/evolution data. This instrument is especially well suited to acquire quantitative time-course data for reactions with small quantities of gas consumed or produced.

47 OTHER INSTRUMENTATION↗

Traversing large graphs on GPUs with unified memory

Due to the limited capacity of GPU memory, the majority of prior work on graph applications on GPUs has been restricted to graphs of modest sizes that fit in memory. Recent hardware and software advances make it possible to address much larger host memory transparently as a part of a feature known as unified virtual memory. While accessing host memory over an interconnect is understandably slower, the problem space has not been sufficiently explored in the context of a challenging workload with low computational intensity and an irregular data access pattern such as graph traversal. We analyse the performance of breadth first search (BFS) for several large graphs in the context of unified memory and identify the key factors that contribute to slowdowns. Next, we propose a lightweight offline graph reordering algorithm, HALO (Harmonic Locality Ordering), that can be used as a pre-processing step for static graphs. HALO yields speedups of 1.5x-1.9x over baseline in subsequent traversals. Our method specifically aims to cover large directed real world graphs in addition to undirected graphs whereas prior methods only account for the latter. Additionally, we demonstrate ties between the locality ordering problem and graph compression and show that prior methods from graph compression such as recursive graph bisection can be suitably adapted to this problem.

Gera, Prasun↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hydrogen Refueling Reference Station Lot Size Analysis for Urban Sites

Hydrogen Fueling Infrastructure Research and Station Technology (H2FIRST) is a project initiated by the DOE in 2015 and executed by Sandia National Laboratories and the National Renewable Energy Laboratory to address R&D barriers to the deployment of hydrogen fueling infrastructure. One key barrier to the deployment of fueling stations is the land area they require (i.e. "footprint"). Space is particularly a constraint in dense urban areas where hydrogen demand is high but space for fueling stations is limited. This work presents current fire code requirements that inform station footprint, then identifies and quantifies opportunities to reduce footprint without altering the safety profile of fueling stations. Opportunities analyzed include potential new methods of hydrogen delivery, as well as alternative placements of station technologies (i.e. rooftop/underground fuel storage). As interest in heavy-duty fueling stations and other markets for hydrogen grows, this study can inform techniques to reduce the footprint of heavy-duty stations as well. This work characterizes generic designs for stations with a capacity of 600 kg/day hydrogen dispensed and 4 dispenser hoses. Three base case designs (delivered gas, delivered liquid, and on-site electrolysis production) have been modified in 5 different ways to study the impacts of recently released fire code changes, colocation with gasoline refueling, alternate delivery assumptions, underground storage of hydrogen, and rooftop storage of hydrogen, resulting in a total of 32 different station designs. The footprints of the base case stations range from 13,000 to 21,000 ft 2 . A significant focus of this study is the NFPA 2 requirements, especially the prescribed setback distances for bulk gaseous or liquid hydrogen storage. While the prescribed distances are large in some cases, these setback distances are found to have a nuanced impact on station lot size; considerations of the delivery truck path, traffic flow, parking, and convenience store location are also important. Station designs that utilize underground and rooftop storage can reduce footprint but may not be practical or economical. For example, burying hydrogen storage tanks underground can reduce footprint, but the cost savings they enable depend on the cost of burial and the cost land. Siting and economic analysis of station lot sizes illustrate the benefit of smaller station footprints in the flexibility and cost savings they can provide. This study can be used as a reference that provides examples of the key design differences that fueling stations can incorporate, the approximate sizes of generic station lots, and considerations that might be unique to particular designs.

08 HYDROGEN↗

Report from the Inaugural Meeting on the Opportunities at the SEEMS Facility

An Inaugural Meeting on the Opportunities at the SEEMS Facility was held at the Spallation Neutron Source (SNS) on June 11 - 12, 2019. It focused on the second of the user communities - industrial and academic researchers. Indeed, the SEEMS design concept started with a Spallation Neutron Source (SNS) study conducted for the Federal Aviation Administration (FAA) that examines test facility options for providing neutron radiation simulating that in the atmosphere originating from cosmic rays and solar particles. The study was stimulated by earlier work calling for neutron radiation facilities with increased capacity and capabilities to meet current and future needs. Regulators, aircraft producers and avionics equipment suppliers recognize the growing urgent need for SEE testing in prototypical radiation fields. Industry standards formalizing procedures to assure that critical systems are robust against SEE phenomena have been issued. Regulatory bodies including the Federal Aviation Administration (FAA) and the European Union Aviation Safety Agency (EASA) now requiring that updated standards are met for aircraft certification.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗