Bench scale experiments for the remediation of Hanford Waste Treatment Plant low activity waste melter off-gas condensate

The Low Activity Waste (LAW) vitrification facility at the Hanford Waste Treatment and Immobilization Plant (WTP) will generate an aqueous condensate recycle stream (LAW Off-Gas Condensate) from the off-gas system. The plan for disposition of this stream during baseline operations is to send it to the WTP Pretreatment Facility, where it will be blended with LAW, concentrated by evaporation and recycled to the LAW vitrification facility again. The primary reason to recycle this stream is so that the semi-volatile 99Tc isotope eventually becomes incorporated into the glass. This stream also contains non-radioactive salt components that are problematic in the melter, so diversion of this stream to another process would eliminate recycling of these salts and would enable simplified operation of the LAW melter and the Pretreatment Facilities. This diversion from recycling this stream within WTP would have the effect of decreasing the LAW vitrification mission duration and quantity of glass waste. The concept being tested here involves removing the 99 Tc so that the decontaminated aqueous stream, with the problematic salts, can be disposed elsewhere.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Standard High Solids Vessel Design De-inventory Simulant Qualification

The Hanford Tank Waste Treatment and Immobilization Plant (WTP) is working to develop a Standard High Solids Vessel Design (SHSVD) process vessel. To support testing of this new design, WTP engineering staff requested that a Newtonian simulant be developed that would represent the de-inventory (residual high-density tank solids cleanout) process. Its basis and target characteristics are defined in 24590-WTP-ES-ENG-16-021 and implemented through PNNL Test Plan TP-WTPSP-132 Rev. 1.0. This document describes the de-inventory Newtonian carrier fluid (DNCF) simulant composition that will satisfy the basis requirement to mimic the density (1.18 g/mL ± 0.1 g/mL) and viscosity (2.8 cP ± 0.5 cP) of 5 M NaOH at 25 °C.1 The simulant viscosity changes significantly with temperature. Therefore, various solution compositions may be required, dependent on the test stand process temperature range, to meet these requirements. Table ES.1 provides DNCF compositions at selected temperatures that will meet the density and viscosity specifications as well as the temperature range at which the solution will meet the acceptable viscosity tolerance.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Simulant Basis for the Standard High Solids Vessel Design

The Waste Treatment and Immobilization Plant (WTP) is working to develop a Standard High Solids Vessel Design (SHSVD) process vessel. To support testing of this new design, WTP engineering staff requested that a Newtonian simulant and a non-Newtonian simulant be developed that would represent the Most Adverse Design Conditions (in development) with respect to mixing performance as specified by WTP. The majority of the simulant requirements are specified in 24590-PTF-RPT-PE-16-001, Rev. 0. The first step in this process is to develop the basis for these simulants. This document describes the basis for the properties of these two simulant types. The simulant recipes that meet this basis will be provided in a subsequent document.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Enhanced LAW Glass Correlation - Phase 2 (Final Report, Rev. 0)

The Office of River Protection is examining options to optimize the LAW facility and LAW glass waste form. VSL and Atkins have evaluated several potential incremental improvements for ORP in support of its evaluation of WTP LAW facility optimization. The objective of the present work was to continue the development of an Enhanced LAW Glass Correlation that can be used to determine the appropriate waste loading, glass composition, and amounts and types of glass former additives for LAW processing at the WTP for any given LAW composition that is delivered to the LAW vitrification facility. The intent is that this correlation, along with the enhanced LAW glass property-composition models, can be used for LAW processing at the WTP with the higher waste loading LAW glass formulations that have been developed for ORP at the VSL.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Effect of Melter-Feed-Makeup on Vitrification Process

Increasing the rate of glass processing in the Hanford Tank Waste Treatment and Immobilization Plant (WTP) will allow shortening the life cycle of waste cleanup at the Hanford Site. While the WTP melters have approached the limit of increasing the rate of melting by enhancing the heat transfer rate from molten glass to the cold cap, a substantial improvement can still be achieved by accelerating the feed-to-glass conversion kinetics. This study investigates in detail how the feed-to-glass conversion process responds to changes in the feed makeup, including the chemicals used for glass-forming and modifying additives, silica grain-size, and heat-generating reactants. By identifying the means of control of primary foam formation and silica grain dissolution, it provides quantitative data needed for a meaningful and economical design of large-scale experiments aimed at achieving faster melting in WTP melters.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Effluent Management Facility Stack Monitor Qualification: Assessment with Surrogate Stacks

Sampling and monitoring at the Waste Treatment and Immobilization Plant (WTP) Effluent Management Facility (EMF) exhaust is required to meet the regulatory criteria that governs stacks that may exceed the 0.1-millirem per year threshold limit given in Title 40 of the Code of Federal Regulations, Part 61, National Emissions Standards for Hazardous Air Pollutants, Subpart H, National Emission Standard for Emissions of Radionuclides other than Radon from Department of Energy Facilities. As a result, the flow conditions and probe location must be within certain bounds as prescribed by the American National Standards Institute/Health Physics Society (ANSI/HPS) standard N13.1-1999. Compliance with the standard may be demonstrated by tests on the stack itself, or with a surrogate stack (i.e., a scale model or other geometrically similar stack). Pacific Northwest National Laboratory (PNNL) has performed scale model stack tests for 11 of the 20 emission points that are planned for the WTP. Additionally, PNNL has full scale stack results from Idaho National Laboratory and PNNL facility stacks to use as references. One or more WTP scale model stack results were expected to be appropriate as a surrogate stack to the EMF. This report describes the EMF stack monitoring location as well as an assessment of existing surrogate stacks used to qualify the EMF stack sampling location.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Dead-End Filtration and Crystalline Silicotitanate Cesium Ion Exchange with Hanford Tank Waste AW-102

The Direct Feed Low-Activity Waste (DFLAW) flowsheet provides for the initial production of immobilized low-activity waste (ILAW) by feeding low-activity waste (LAW) directly from tank farms to the Hanford Tank Waste Treatment and Immobilization Plant (WTP) LAW facility for immobilization. Prior to the transfer of feed to the WTP LAW facility, tank supernatant waste will be pretreated by the Tank Side Cesium Removal (TSCR) system to meet the WTP LAW waste acceptance criteria (<3.18E-5 Ci 137Cs/mole of Na). This pretreatment facility will filter the waste to remove suspended solids and remove cesium from the waste stream through ion exchange. Bench-scale filtration testing of 7.4 liters of diluted of AW-102 supernate was conducted using dead-end filtration in the hot cells of the Radiochemical Processing Laboratory at Pacific Northwest National Laboratory. A Mott 70-mm disc filter (media grade 5) was used to capture solids. The filter area was adjusted to 2.2 in2 to match the planned TSCR supernate process volume to surface area ratio. There was no indication of filter fouling and no recoverable solids were observed on the filter. Ion exchange testing with the filtered, diluted AW-102 supernatant was conducted using crystalline silicotitanate (CST) ion exchange media. The IONSIV R9140-B CST was provided by Honeywell UOP, LLC in 2018 (Lot number 8056202-999). The column testing operations were prototypic to the intended Low-Activity Waste Pretreatment System operations in a lead-lag column format, although on a small-scale basis with 10-mL CST beds. The feed was processed downflow through the lead column and then through the lag column at ~1.8 bed volumes per hour (BV/h). After 88.6 BVs of feed processing, the volume in the feed bottle dropped below the inlet tube and the lead column fluid headspace was displaced with air. Feed processing was suspended while a new column was prepared and installed into the lead position. A total of 450 BVs of diluted AW-102 feed were processed through the new lead column; only 4.3% Cs breakthrough was achieved. This volume of feed was insufficient to generate useful Cs loading information without extrapolation. A straight-line extrapolation was used to determine the 50% breakthrough of the lead column and contract limit breakthrough from the lag. The values were found to be 1200 BVs and 930 BVs, respectively.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cesium Removal from Tank Waste Simulants Using Crystalline Silicotitanate at 12% and 100% TSCR Bed Heights

The Direct Feed Low-Activity Waste flowsheet provides for the early production of immobilized low-activity waste (LAW) by feeding waste directly from Hanford tank farms to the Hanford Tank Waste Treatment and Immobilization Plant (WTP) for vitrification. Prior to the transfer of feed to the WTP LAW Vitrification Facility, tank waste supernatant will be pretreated by the Tank Side Cesium Removal (TSCR) system to meet the WTP LAW waste acceptance criteria (<3.18E-5 Ci 137 Cs/mole of Na). This pretreatment will remove cesium from the waste stream using ion exchange (IX). The selected media for IX is crystalline silicotitanate (CST), product number UOP-IONSIV-R9140-B, manufactured by Honeywell UOP LLC (Des Plaines, IL). Testing was requested by Washington River Protection Solutions to better define IX processing using Low-Activity Waste Pretreatment System (LAWPS) prototypic IX unit operation process steps at full height and medium height. The information is intended to significantly contribute towards establishing accurate process flowsheets for the individual feed campaigns planned for the LAWPS. Column testing at both the medium (12% of the full bed height) and full height scales was conducted to evaluate process variables and scale up performance of Cs exchange onto the CST, Lot 8056202-999. Nominal process conditions used 5.6 M Na simulant processed at 1.8 bed volumes per hour (BV/h) at 20 °C. Process variables included 1) increased process temperature to 35 °C, 2) increased Na concentration to 6.0 M, 3) added organics to the 5.6 M Na simulant, and 4) flowrate changes. The medium scale tests used single columns containing 44 mL of <25 mesh CST in a 1.44 cm diameter column, 27 cm tall CST bed. The full height columns used lead/lag columns containing 1.15 L unsieved (as-received) CST in 2.54-cm-diameter columns, 226 cm tall CST beds. Two process flowrates were tested at the full height: 1.30 and 1.82 BV/h. IX testing with simulant solutions was conducted using TSCR prototypic IX unit operations: feed processing, feed displacement with 0.1 M NaOH, water rinse, and solution expulsion with compressed air.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SRNL Report on Vendor Solicitation and Selective Ion-Electrode Testing

Effective operation of the Hanford Tank Waste Treatment and Immobilization Plant (WTP) will require information collected from sampling and/or monitoring to maintain environmental compliance, product quality, and operating efficiency. The U.S. Department of Energy (DOE) – Office of River Protection (ORP) recognizes the potential long-term benefit of developing real-time, in-line monitoring (RTIM) at the WTP to improve the current strategy of collecting tens of thousands of samples and analyzing them. In-line monitoring can decrease processing time associated with waiting for sample analysis, reduce workers’ exposure to radiation and chemical hazards, decrease secondary waste volumes, potentially improve product quality, and provide production support and enhance overall operational control. The Assistant Manager, WTP chartered an Integrated Technical Team (ITT), which includes personnel from the Savannah River National Laboratory (SRNL), Bechtel National, Inc., and DOE-ORP, to evaluate the capability and potential benefits of replacing routine sample collection requirements with real-time, in-line monitoring. The initial focus of the ITT is the Direct Feed Low Activity Waste (DFLAW) Program. This work scope is being performed in multiple phases. Phase 1 is Requirements and Opportunities Analysis, Phase 2 is Applications and Benefits Determination, and Phase 3 is Qualification and Demonstration. Phase 1 included 6 tasks and was completed by SRNL in 2017. The tasks in Phase 1 were: (1) determining the functional requirements for determining analytes and properties of streams, (2) determining the technical basis for process control, (3) determining the sampling points within the Low Activity Waste (LAW) facility and Effluent Management Facility (EMF), (4) data quality and management, (5) process control challenges, and (6) preparing a Preliminary Analysis Plan. DOE-ORP was briefed on the findings from the Phase 1 tasks and requested that Phase 2 work focus on establishing a basis for a materials balance approach that minimized process sampling. The Phase 2 work scope contains tasks to evaluate a materials balance only approach as well as continuing scoping evaluations for instruments that could be used for RTIM. The Phase 2 work scope was completed by both SRNL and Pacific Northwest National Laboratory (PNNL). The tasks performed in Phase 2 were: 1. Overall program administration and technical oversight 2. Evaluation of a Material Balance Approach, a. Evaluation of uncertainty of this approach compared to uncertainty of current methods b. Evaluation of automating the material balance within the framework of existing control software, c. Development of the methodology to obtain and evaluate data during cold commissioning to support a material balance approach, and d. Development of a framework to utilize during presentation of the revised approach to stakeholders and regulators. 3. Screening Evaluations of Instruments to Supplement the Material Balance Approach, a. AP-105 melter condensate evaluations, and b. Screening testing with simulants. 4. Evaluation of the current DFLAW feed qualification program to identify analytes that could be eliminated, a. Inorganic analytes, b. Radionuclides, and c. Organic analytes. This report describes the results of Task 3b, Screening testing with simulants. The Savannah River National Laboratory requested demonstrations of commercially available analytical instruments by the vendors or laboratory demonstration. The techniques tested included: Raman spectroscopy, Infrared spectroscopy (IR), laser induced breakdown spectroscopy (LIBS), X-Ray Fluorescence Spectroscopy (XRF), and ion-selective electrochemical probes. Additionally, the instrumentation would need to be durable enough to withstand the environment of the plant, preferably with little to no maintenance. The insertion point of the instrument would be dependent upon the instrumentation.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Iodine Distribution During Evaporation of Hanford Waste Treatment Plant Direct Feed Low Activity Waste Effluent Management Facility Simulant

The Hanford Waste Treatment and Immobilization Plant (WTP) Low Activity Waste (LAW) vitrification facility will generate an aqueous condensate recycle stream from the off-gas system. The baseline plan for disposition of this stream during full WTP operations is to send it to the WTP Pretreatment Facility, where it will be blended with LAW, concentrated by evaporation, and recycled to the LAW vitrification facility. However, during the Direct Feed LAW (DFLAW) scenario, planned disposition of this stream involves concentrating the condensate in a new evaporator at the Effluent Management Facility (EMF) and returning it to the LAW melter. The LAW melter condensate stream will contain components, e.g. halides and sulfates, that are volatile at melter temperatures, have limited solubility in glass waste forms, and present a material corrosion concern. Further, some minor constituents in the melter condensate, such as volatile organic compounds and iodine, have been found to be at least partially volatile in the EMF. The condensate from the EMF will be sent to the Hanford Effluent Treatment Facility (ETF). The presence of some recalcitrant organics and iodine, as 129I, are expected to be problematic in the ETF. In order to better predict and prepare for the distribution of organics and 129I in the flowsheet, it is key to understand their chemistry and experimentally determine their behavior during evaporation. To do this, modeling and testing were performed to examine the speciation of iodine under relevant conditions, as well as determine partitioning of iodine and the organics in the EMF evaporator. This overall program examines the potential treatment and immobilization of the LAW melter condensate stream to enable alternative disposal. The objective of this task was to (1) perform modeling to determine the speciation and fate of iodine species, (2) prepare a simulant of the LAW Melter Off-gas Condensate expected during DFLAW operations, (3) spike in the key volatile organics and non-radioactive iodine, and (4) demonstrate evaporation in order to predict the final composition of the effluents from the EMF evaporator to aid in planning for their disposition. The results of the modeling of iodine speciation indicate that the iodine is expected to remain in the evaporator pot as iodide and possibly iodate ion if the pH is raised to 11.5-12, which is the planned condition for the EMF. Experimental testing confirmed that the iodide remained in the evaporator concentrate and was below detection limits in all condensate and knock-out pot samples, indicating it was not volatile. The organic nitrile compounds that were added to the simulant were absent from the evaporator feed solution, either lost through evaporation, or more likely, decomposition. The acetone and methylene chloride were below the target values in the feed and condensate samples, and were presumably lost to evaporation or decomposition.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Review of Submerged Bed Scrubber Assumptions in the Hanford Waste Treatment and Immobilization Plant Bases and Requirements Document

A review was performed of the assumptions in the Hanford Waste Treatment and Immobilization Plant Bases and Requirements Document (BARD) for the Low Activity Waste (LAW) Submerged Bed Scrubber (SBS). This review was performed to evaluate how the assumptions impact the TOPSim process models that utilize the assumptions for system modeling. The RPP Integrated Flowsheet uses TOPSim to model the entire waste retrieval and treatment process for the Hanford tank waste. This model relies on a number of inputs, including the BARD. The BARD represents the basis for the WTP process models; as such, it contains some assumptions that are valid for the models that will not accurately reflect actual operation. For example, the amount of LAW condensate generated is overstated in the BARD to allow for conservatism in the design of the condensate handling unit operations. The assumptions in the BARD for the LAW SBS were reviewed to evaluate how actual operation could differ from the design basis assumptions. It should be noted that this review did not evaluate nor is it intended to address issues related to design of the WTP facility such that the information in this report is should not be viewed as issues with the design of the WTP facility nor should the information be used without additional evaluation to generate design concerns.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of a Material Balance Only and Material Balance with Real-Time In-line Monitoring Approaches for DFLAW Processing

The Assistant Manager, WTP chartered an Integrated Technical Team (ITT), which includes personnel from the Savannah River National Laboratory (SRNL), Pacific Northwest National Laboratory (PNNL), from the Savannah River National Laboratory (SRNL), Pacific Northwest National Laboratory (PNNL), Bechtel National, Inc., and DOE-ORP, to evaluate the capability and potential benefits of replacing sample collection/analyses requirements with real-time, in-line monitoring. The initial focus of the ITT is the Direct Feed Low Activity Waste (DFLAW) Program. This work scope is being performed in multiple phases. The Phase 2 work scope contains tasks to evaluate a materials balance only approach as well as continuing scoping evaluations for instruments that could be used for Real-Time In-Line Monitoring (RTIM). The Phase 2 work scope for evaluation of a materials balance approach was completed by both SRNL and PNNL and is documented in this report. The material balance evaluation included a review of the WTP Low Activity Waste (LAW) vitrification process as well as the WTP Effluent Management Facility (EMF) process. Sampling requirements and unit operations were reviewed to determine which sample requirements could be met with a material balance without significantly increasing processing or reporting uncertainties.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cold Crucible Vitrification of CST and Simulated Hanford Tank Waste

The Direct Feed Low-Activity Waste (DFLAW) flowsheet provides for the initial production of immobilized low-activity waste (ILAW) by feeding low-activity waste (LAW) from tank farms to the Hanford Waste Treatment and Immobilization Plant (WTP) LAW Facility for immobilization. Prior to the transfer of feed to the WTP LAW Vitrification Facility, tank supernatant waste will be pretreated by the Tank-Side Cesium Removal (TSCR) system to meet the WTP LAW waste acceptance criteria (<3.18× 10 -5 Ci 137 Cs/mole of Na). This pretreatment will remove cesium from the waste stream through ion exchange (IX). The selected media for IX is crystalline silicotitanate (CST).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Impact of Crystalline Silicotitanate Particle Size on Cesium Removal Efficiency

Washington River Protection Solutions is working on a Tank-Side Cesium Removal (TSCR) system to remove Cs from Hanford tank waste supernate. Removal of 137 Cs from tank waste supernate by TSCR results in a low-activity waste (LAW) form that can be fed directly to the Hanford Waste Treatment and Immobilization Plant (WTP) LAW vitrification facility, where the supernate can be vitrified into a glass form. Crystalline silicotitanate (CST) ion exchange media, manufactured by Honeywell UOP, LLC (product IONSIV TM R9140-B), was selected for use as the ion exchange media to remove Cs at TSCR. The particle size used in testing is expected to impact the kinetic performance of the ion exchange media. Therefore, two single-column systems were tested with CST Lot 2002009604. One column contained <25 mesh sieve cut fraction and the other column contained <35 mesh sieve cut fraction. Flowrate through both test systems was adjusted to match the CST contact time expected for the full-scale operation, i.e., matched bed volumes per hour (BV/h) at 1.83 BV/h. The feed was processed downflow through the columns until ~1000 BVs of feed were processed. The waste acceptance criteria (WAC) limit for the WTP LAW vitrification facility is <3.18E-5 Ci 137 Cs per mole Na. For a tank waste containing 156 µCi/mL 137 Cs and 5.6 M Na, up to 0.114% of the influent 137 Cs concentration may be delivered to the WTP (based on 137 Cs content in AP-107 tank waste); this required a Cs decontamination factor of 876. The WAC limit was used as one of the relevant process parameters, along with the 50% breakthrough point, Cs loading per gram of CST, and the mass transfer zone.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Continuous Laboratory-Scale Melter Runs for System Evaluation

The Waste Treatment and Immobilization Plant (WTP) will process and stabilize waste that is stored in underground tanks on the Hanford Site. Currently, the first phase of the planned WTP startup and operation, called Direct Feed Low-Activity Waste (DFLAW), involves directly feeding only the liquid portion of the waste to electric melters in the WTP Low-Activity Waste (LAW) Vitrification Facility without full pretreatment. A second portion of the tank waste, called high-level waste (HLW), is set to contain most of the radioactivity inventory.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Ion Exchange Processing of AP-105 Hanford Tank Waste through Crystalline Silicotitanate in a Staged 2- then 3-Column System

The U.S. Department of Energy (DOE) is working to expedite processing of Hanford tank waste supernate at the Hanford Waste Treatment and Immobilization Plant (WTP). To support this goal, Washington River Protection Solutions, LLC (WRPS, Richland, WA) is designing a system for suspended solids and cesium (Cs/ 137 Cs) removal from Hanford tank waste supernate. The effluent will then be sent to the WTP Low-Activity Waste (LAW) Facility for vitrification. The Cs removal is critical for eliminating the high dose rate associated with 137 Cs and facilitating a contact maintenance philosophy for the LAW Facility. The maximum 137 Cs concentration in the LAW sent to the WTP is targeted to be below the 3.18E-5 Ci 137 Cs/mole of Na waste acceptance criteria (WAC) limit. The filtration and ion exchange systems will be placed near the Hanford tanks and are collectively termed the Tank Side Cesium Removal (TSCR) system.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Vitrification of Hanford Tank Wastes for Condensate Recycle and Feed Composition Changeover Testing

During the vitrification of Hanford Site nuclear waste at the Waste Treatment and Immobilization Plant (WTP), which is a part of the safe and efficient retrieval, treatment, and disposal mission of the U.S. Department of Energy Office of River Protection, the offgas condensate generated from the waste-to-glass conversion is currently planned to be concentrated by evaporation in the Effluent Management Facility (EMF). This concentrated condensate can then be recycled back to the incoming waste and vitrified. To test the recycle process, an apparatus was designed and built to mimic the EMF evaporator and was then used to concentrate a volume of condensate produced during the vitrification of a sample of Hanford tank 241-AP-107 (referred to herein as AP-107) waste in a continuous laboratory-scale melter (CLSM). The concentrated condensate was added to an additional sample of AP-107 waste, to mimic one round of the recycle process, and the combined solution was vitrified, producing a second round of recycle condensate. In the current study, the EMF test apparatus was used to concentrate the second-round recycle condensate under evaporation conditions (at 45 °C and 1.4 psia) designed to emulate EMF operation. The condensate was successfully concentrated by a factor of ~10 while retaining over 95 % of the technetium-99 ( 99 Tc), Cs, and I inventories in the concentrate. Another portion of AP-107 waste was retrieved by Washington River Protection Solutions, LLC (WRPS) and transferred to Pacific Northwest National Laboratory (PNNL), where it was pretreated and then combined with the second-round recycle AP-107 condensate concentrate and glass-forming chemicals (GFCs) to form the two-time recycle AP-107 melter feed, approximating a second round to the recycling action to be performed at the WTP. A portion of AP-105 waste was also retrieved by WRPS and provided to PNNL for pretreatment and combining with GFCs to form AP-105 melter feed. The two-time recycle AP-107 and AP-105 melter feeds were processed consecutively in the CLSM. The CLSM run proceeded for 13.63 hours, producing 9.70 kg of glass for an average glass production rate of 1464 kg m 2 d -1 during the two-time recycle AP-107 feed charging and 1568 kg m 2 d -1 during the AP-105 feed charging. The rate during AP-107 charging was essentially equivalent to the rate when processing no-recycle AP-107 feed and lower than that achieved when processing one-time recycle AP-107 feed. However, all rates were within the potential range of variability when processing melter feeds with similar composition in the CLSM. Likewise, the rate during AP-105 charging was higher than the previous rate processing AP-105, but within the potential CLSM range. The cold-cap characteristics changed from the typically thin AP-107 cold cap to a foamy-edged cold cap as previously seen with AP-105 shortly after transitioning to the AP-105 melter feed. The glass produced during the CLSM run was within 10 % of its target composition for the primary glass components. The CaO and Li 2 O targets varied by more than 1 wt% between the two-time recycle AP-107 and AP-105 glass targets and it took about 2 turnovers of the CLSM glass inventory to reach a relative chemical steady state in the glass for CaO and Li 2 O after the melter feed inputs were switched. The 99 Tc and total cesium content in the melter feeds were maintained at concentrations expected to be experienced at the WTP. During the CLSM run, while processing the two-time recycle AP-107 melter feed at a relative chemical steady state, the 99 Tc/Cs ratio was 10, and 34% of 99 Tc and 74% of Cs were retained in the glass. These values were higher than those measured in the CLSM run with one-time recycle AP-107 melter feed. After the transition to processing the AP-105 melter feed, when the production reached a relative chemical steady state, the 99 Tc/Cs ratio was 77 while 44% of 99 Tc was retained in the glass. The C's retention during this time frame reached 200% due to the excess C's in the glass after the target content decreased to 15% of its initial level in the two-time recycle AP-107 melter feed to the lower target in the Ap-105 melter feed. While iodine was below inductively coupled plasma mass spectrometry analytical reporting limits in the melter feed and glass samples, it was detected in quantities above the analytical reporting limits in the liquid and filter samples collected from the CLSM offgas treatment system. The behavior of iodine in the CLSM offgas treatment system followed a similar pattern to those of 99 Tc and Cs.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Follow-on Report of Analysis of Approaches to Supplemental Treatment of Low–Activity Waste at the Hanford Nuclear Reservation (Volumes I & II)

The Hanford Site, in southeast Washington State, is preparing to disposition approximately 56,000,000 gallons (56 Mgal) of radioactive and chemically hazardous wastes currently stored in underground tanks at the site. Tank wastes will be divided into a high-activity fraction and a low-activity fraction for subsequent treatment and disposition. A waste processing and treatment facility, the Waste Treatment and Immobilization Plant (WTP), will include the high-level waste (HLW) vitrification facility (WTP HLW Vitrification Facility) for immobilizing the high-activity fraction and a low-activity waste (LAW) vitrification facility (WTP LAW Vitrification Facility) for immobilizing the low-activity fraction. Both facilities will use vitrification technology to immobilize the Hanford tank wastes in a glass waste form.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗