Search NASA⌕ Search

SEARCH · Search NASA

Results for “Wave Energy Conversion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

242 records · Page 14

Ring-Down Spectroscopy for Characterizing a CW Raman Laser

.A relatively simple technique for characterizing an all-resonant intracavity continuous-wave (CW) solid-state Raman laser involves the use of ring-down spectroscopy. As used here, characterizing signifies determining such parameters as threshold pump power, Raman gain, conversion efficiency, and quality factors (Q values) of the pump and Stokes cavity modes. Heretofore, in order to characterize resonant-cavity-based Raman lasers, it has usually been necessary to manipulate the frequencies and power levels of pump lasers and, in each case, to take several sets of measurements. In cases involving ultra-high-Q resonators, it also has been desirable to lock pump lasers to resonator modes to ensure the quality of measurement data. Simpler techniques could be useful. In the present ring-down spectroscopic technique, one infers the parameters of interest from the decay of the laser out of its steady state. This technique does not require changing the power or frequency of the pump laser or locking the pump laser to the resonator mode. The technique is based on a theoretical analysis of what happens when the pump laser is abruptly switched off after the Raman generation reaches the steady state. The analysis starts with differential equations for the evolution of the amplitudes of the pump and Stokes electric fields, leading to solutions for the power levels of the pump and Stokes fields as functions of time and of the aforementioned parameters. Among other things, these solutions show how the ring-down time depends, to some extent, on the electromagnetic energy accumulated in the cavity. The solutions are readily converted to relatively simple equations for the parameters as functions of quantities that can be determined from measurements of the time-dependent power levels. For example, the steady-state intracavity conversion efficiency is given by G1/G2 1 and the threshold power is given by Pin(G2/G1)2, where Pin is the steady-state input pump power immediately prior to abrupt switch-off, G1 is the initial rate of decay of the pump field, and G2 is the final rate of decay of the pump field. Hence, it is possible to determine all the parameters from a single ring-down scan, provided that the measurements taken in that scan are sufficiently accurate and complete.

Matsko, Andrey↗

Classification of compact objects and model comparison using EOS knowledge

Nuclear theory and experiments, alongside astrophysical observations, constrain the equation of state (EOS) of supranuclear-dense matter. Conversely, knowledge of the EOS allows an improved interpretation of nuclear or astrophysical data. In this article, we use several established constraints on the EOS and the new NICER measurement of PSR J0437-4715 to comment on the nature of the primary companion in GW230529 and the companion of PSR J0514-4002E. We find that, with a probability of ≳84% and ≳68%, respectively, both objects are black holes. These likelihoods increase to above 95% when one uses GW170817’s remnant as an upper limit on the TOV mass. We also demonstrate that the current knowledge of the EOS substantially disfavors high masses and radii for PSR J⁢0030+0451, inferred recently when combining NICER with XMM-Newton background data and using particular hot-spot models. Lastly, we also use our obtained EOS knowledge to comment on measurements of the nuclear symmetry energy, finding that the large value predicted by the PREX-II measurement displays some mild tension with other constraints on the EOS.

79 ASTRONOMY AND ASTROPHYSICS↗

Reactivation of a Tin-Oxide-Containing Catalyst

The electrons in electric-discharge CO2 lasers cause dissociation of some CO2 into O2 and CO, and attach themselves to electronegative molecules such as O2, forming negative O2 ions, as well as larger negative ion clusters by collisions with CO or other molecules. The decrease in CO2 concentration due to dissociation into CO and O2 will reduce the average repetitively pulsed or continuous wave laser power, even if no disruptive negative ion instabilities occur. Accordingly, it is the primary object of this invention to extend the lifetime of a catalyst used to combine the CO and O2 products formed in a laser discharge. A promising low-temperature catalyst for combining CO and O2 is platinum on tin oxide (Pt/SnO2). First, the catalyst is pretreated by a standard procedure. The pretreatment is considered complete when no measurable quantity of CO2 is given off by the catalyst. After this standard pretreatment, the catalyst is ready for its low-temperature use in the sealed, high-energy, pulsed CO2 laser. However, after about 3,000 minutes of operation, the activity of the catalyst begins to slowly diminish. When the catalyst experiences diminished activity during exposure to the circulating gas stream inside or external to the laser, the heated zone surrounding the catalyst is raised to a temperature between 100 and 400 C. A temperature of 225 C was experimentally found to provide an adequate temperature for reactivation. During this period, the catalyst is still exposed to the circulating gas inside or external to the laser. This constant heating and exposing the catalyst to the laser gas mixture is maintained for an hour. After heating and exposing for an appropriate amount of time, the heated zone around the catalyst is allowed to return to the nominal operating temperature of the CO2 laser. This temperature normally resides in the range of 23 to 100 C. Catalyst activity can be measured as the percentage conversion of CO to CO2. In the specific embodiment described above, the initial steady-state conversion percentage was 70 percent. After four days, this conversion percentage decreased to 67 percent. No decrease in activity is acceptable because the catalyst must maintain its activity for long periods of time. After being subjected to the reactivation process of the present invention, the conversion percentage rose to 77 percent. Such a reactivation not only returned the catalyst to its initial steady state but resulted in a 10-percent improvement over the initial steady state value.

Hess, Robert↗

Full-wave and half-wave rectification in second-order motion perception

Microbalanced stimuli are dynamic displays which do not stimulate motion mechanisms that apply standard (Fourier-energy or autocorrelational) motion analysis directly to the visual signal. In order to extract motion information from microbalanced stimuli, Chubb and Sperling [(1988) Journal of the Optical Society of America, 5, 1986-2006] proposed that the human visual system performs a rectifying transformation on the visual signal prior to standard motion analysis. The current research employs two novel types of microbalanced stimuli: half-wave stimuli preserve motion information following half-wave rectification (with a threshold) but lose motion information following full-wave rectification; full-wave stimuli preserve motion information following full-wave rectification but lose motion information following half-wave rectification. Additionally, Fourier stimuli, ordinary square-wave gratings, were used to stimulate standard motion mechanisms. Psychometric functions (direction discrimination vs stimulus contrast) were obtained for each type of stimulus when presented alone, and when masked by each of the other stimuli (presented as moving masks and also as nonmoving, counterphase-flickering masks). RESULTS: given sufficient contrast, all three types of stimulus convey motion. However, only one-third of the population can perceive the motion of the half-wave stimulus. Observers are able to process the motion information contained in the Fourier stimulus slightly more efficiently than the information in the full-wave stimulus but are much less efficient in processing half-wave motion information. Moving masks are more effective than counterphase masks at hampering direction discrimination, indicating that some of the masking effect is interference between motion mechanisms, and some occurs at earlier stages. When either full-wave and Fourier or half-wave and Fourier gratings are presented simultaneously, there is a wide range of relative contrasts within which the motion directions of both gratings are easily determinable. Conversely, when half-wave and full-wave gratings are combined, the direction of only one of these gratings can be determined with high accuracy. CONCLUSIONS: the results indicate that three motion computations are carried out, any two in parallel: one standard ("first order") and two non-Fourier ("second-order") computations that employ full-wave and half-wave rectification.

Motion Perception/physiology↗

A Measurement of Atmospheric Circular Polarization with POLARBEAR

At millimeter wavelengths, the atmospheric emission is circularly polarized owing to the Zeeman splitting of molecular oxygen by the Earth's magnetic field. We report a measurement of the signal in the 150 GHz band using 3 yr of observational data with the POLARBEAR project. Nonidealities of a continuously rotating half-wave plate (HWP) partially convert circularly polarized light to linearly polarized light. While POLARBEAR detectors are sensitive to linear polarization, this effect makes them sensitive to circular polarization. Although this was not the intended use, we utilized this conversion to measure circular polarization. We reconstruct the azimuthal gradient of the circular polarization signal and measure its dependency from the scanning direction and the detector bandpass. We compare the signal with a simulation based on atmospheric emission theory, the detector bandpass, and the HWP leakage spectrum model. We find the ratio of the observed azimuthal slope to the simulated slope is 0.92 ± 0.01(stat) ± 0.07(sys). This ratio corresponds to a brightness temperature of 3.8 mK at the effective band center of 121.8 GHz and bandwidth of 3.5 GHz estimated from representative detector bandpass and the spectrum of Zeeman emission. This result validates our understanding of the instrument and reinforces the feasibility of measuring the circular polarization using the imperfection of continuously rotating HWP. Continuously rotating HWP is popular in ongoing and future cosmic microwave background experiments to modulate the polarized signal. This work shows a method for signal extraction and leakage subtraction that can help measure circular polarization in such experiments.

79 ASTRONOMY AND ASTROPHYSICS↗

CH 3 Radical Generation in Microplasmas for Up-Conversion of Methane

The conversion of methane, CH 4 , into higher value chemicals using low temperature plasmas is challenged by both improving efficiency and selectivity. One path towards selectivity is capturing plasma produced methyl radicals, CH 3 , in a solvent for aqueous processing. Due to the rapid reactions of methyl radicals in the gas phase, the transport distance from production of the CH 3 to its solvation should be short, which then motivates the use of microplasmas. The generation of CH 3 in Ar/CH 4 /H 2 O plasmas produced in nanosecond pulsed dielectric barrier discharge microplasmas is discussed using results from a computational investigation. The microplasma is sustained in the channel of a microfluidic chip in which the solvent flows along one wall or in droplets. CH 3 is primarily produced by electron-impact of and dissociative excitation transfer to CH 4 , as well as CH 2 reacting with CH 4 . CH 3 is rapidly consumed to form C 2 H 6 which, in spite of being subject to these same dissociative processes, accumulates over time, as do other stable products including C 3 H 8 and CH 3 OH. The gas mixture and electrical properties were varied to assess their effects on CH 3 production. CH 3 production is largest with 5% CH 4 in the Ar/CH 4 /H 2 O mixture due to an optimal balance of electron-impact dissociation, which increases with CH 4 percentage, and dissociative excitation transfer and CH 2 reacting with CH 4 , which decrease with CH 4 percentage. Design parameters of the microchannels were also investigated. Increasing the permittivity of the dielectrics in contact with the plasma increased the ionization wave intensity which increased CH 3 production. Increased energy deposition per pulse generally increased CH 3 production as does lengthening pulse length up to a certain point. The arrangement of the solvent flow in the microchannel can also affect the CH 3 density and fluence to the solvent. The fluence of CH 3 to the liquid solvent is increased if the liquid is immersed in the plasma as a droplet or is a layer on the wall where the ionization wave terminates. The solvation dynamics of CH 3 with varying numbers of droplets was also examined. Here, the maximum density of solvated methyl radicals CH 3aq occurs with a large number of droplets in the plasma. However, the solvated CH 3aq density can rapidly decrease due to desolvation, emphasizing the need to quickly react the solvated species in the solvent.

03 NATURAL GAS↗

The Impact of Operational Strategies and Load Fluctuations on Anion Exchange Membrane Water Electrolyzer Degradation

This study reports on the durability of anion exchange membrane water electrolyzers (AEMWEs) at the cell level in a supporting electrolyte (1 M) and the impact of operational profiles on cell degradation. While constant load shows significant voltage loss, including a current hold at 1 A cm −2 and a potential hold at 2 V, it generally occurs in the first 70 h of testing. These losses are likely due to passivation altering site reactivity and cell kinetics, and are largely recoverable upon load cycling and diagnostics at the end of test. Furthermore, square and triangular-wave cycling do not show cell degradation and indicate that AEMWEs are not vulnerable to load cycling. When operating outside of this potential window (1.45–2 V), cell voltage decay rates markedly increase and the losses are not recoverable. This includes a current density hold at 4.0 A cm −2 with high cell voltages (>2.4 V for test duration) and cycling between 0 and 2 V to simulate start–stop, where more than a 50% loss in current density occurs over 50 h. The findings presented here demonstrate the high durability of AEMWEs, particularly when operating with load fluctuations, and may allow for durability advantages compared to iridium and proton exchange membrane systems.

08 HYDROGEN↗

On-Chip Cavity Electroacoustics Using Lithium Niobate Phononic Crystal Resonators

Mechanical systems are pivotal in quantum technologies because of their long coherent time and versatile coupling to qubit systems. So far, the coherent and dynamic control of gigahertz-frequency mechanical modes mostly relies on optomechanical coupling and piezoelectric coupling to superconducting qubits. Here, we demonstrate on-chip cavity electroacoustic dynamics using our microwave-frequency electrically modulated phononic crystal resonators on lithium niobate. Leveraging the high dispersion of phononic crystal, our acoustic modes space unevenly in the frequency spectrum, emulating atomic energy levels. Atomiclike transitions between different acoustic modes are selectively achieved by applying electrical fields to modulate acoustic modes via the nonlinear piezoelectricity of lithium niobate. Among two modes, we demonstrate Autler-Townes splitting, ac Stark shift, and Rabi oscillation with a maximum cooperativity of 4.18. Extending to three modes, we achieve nonreciprocal frequency conversions with an isolation up to 20 dB. Nonreciprocity can be tuned by the time delay between the two modulating pulses. Finally, our cavity electroacoustic platform could find broad applications in sensing, microwave signal processing, acoustic computing, and quantum acoustics.

Rabi model↗