Search NASA⌕ Search

SEARCH · Search NASA

Results for “Wind integration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

A country-scale green energy-water-hydrogen nexus: Jordan as a case study

Many developing countries suffer from a shortage of clean energy-water production, causing significant dependency on imported fossil fuel to meet the local energy and freshwater demands. Furthermore, when planning a 100 % renewable energy system (RES) to match the energy demand on an hourly basis, the RES is usually oversized. Hence, unavoidable large amounts of excess energy would be generated during hours of high production, low demand, and fully charged energy storage systems (ESSs). Hence, using Jordan as a case study, this work proposes a novel integrated system of wind, solar photovoltaic (PV), and lithium-ion ESS to match 100 % of the country's energy demand while using the excess generated power to drive reverse osmosis water desalination plants to match the demand of freshwater as well. Furthermore, the remaining excess energy is used for producing green hydrogen. A techno-economic optimizer was developed to show that this concept is indeed feasible. Here, the model was used to scan Jordan for the fitting sites of the highest demand-supply matching and the lowest levelized cost of electricity (LCOE), simultaneously. Three different integration scenarios are presented, namely PV-ESS, wind-ESS, and hybrid PV-wind-ESS RESs. The hybrid system showed the best performance, especially compared to the wind-ESS RES, in terms of total installed capacity (33.37 GW), LCOE (0.0492 USD/kWh), specific water cost (0.3629 USD/m 3 ), and energy and water demand-supply fractions (99.47 and 96.16 %, respectively). Storing desalinated water in natural aquifers was found to be a favorable option to enhance the performance of the three systems, where stored water by the end of the year was sufficient to cover the freshwater requirements for several following years. Finally, the remaining excess energy is used to produce green hydrogen with an annual production of up to 1.37 million tons and a specific cost down to 1.08 USD/kg.

14 SOLAR ENERGY↗

Dynamics and stability of wind turbine generators

Synchronous and induction generators are considered. A comparison is made between wind turbines, steam, and hydro units. The unusual phenomena associated with wind turbines are emphasized. The general control requirements are discussed, as well as various schemes for torsional damping such as speed sensitive stabilizer and blade pitch control. Integration between adjacent wind turbines in a wind farm is also considered.

Hinrichsen, E. N.↗

Assessment of the 60 Km Rapid Update Cycle (RUC) with Near Real-Time Aircraft Reports

NASA is developing the Center-TBACON Advisory System (CTAS), a set of Air Traffic Management (ATM) Decision Support Tools (DST) to enable controllers to increase airspace capacity and flight efficiency. A crucial component of the CTAS, or any ATM DST, is the computation of the time-of-flight of aircraft along flight path segments which requires accurate knowledge of the wind through which the aircraft are flying. CTAS currently uses wind information from the Rapid Update Cycle (RUC), a numerical prediction model run operationally by the National Weather Service (NWS) National Center for Environmental Prediction (NCEP). There exists near real-time wind observations from commercial aircraft that can be used to increase the accuracy of the RUC wind forecasts via the FAA Integrated Terminal Weather System (ITWS) Terminal Winds (TW) algorithm. This report presents a study based on the application of the ITWS TW algorithm as an improvement to the baseline RUC product. Terminal Winds generally does not support the full Center airspace; the domain of the prototype MIT/LLITWS TW system was increased to cover the Denver Center airspace to support this study. This study has three goals: 1) determine the errors in the baseline 60-kilometer resolution RUC forecast wind fields relative to the needs of en route DSTs such as CTAS; 2) determine the benefit of using the TW algorithm to refine the RUC forecast wind fields with near real-tlme Meteorological Data Collection and Reporting System (MDCRS) aircraft reports, and 3) identify factors that influence wind field errors in order to improve accuracy and estimate errors in real time. The data for this study were collected over a one-year period for the Denver Center airspace and over one miIlion verification observations were used. This study is part of a larger effort funded by NASA which includes the NOAA/FSL.

Cole, R. E.↗

Improving Wind Power Market Value with Various Aspects of Diversification: Preprint

The wind generation share in many European bidding zones is already large enough to impact the market value of wind power and wind energy is getting less-than-average market price in day-ahead markets. As alternatives to investing in dedicated energy storage, there are two main ways to mitigate the decreasing market value trend, the first being different diversification measures (geographical spread, alternative wind turbine technologies, integration with solar), and the second being demand flexibility measures. Examples of these measures from some European and USA studies are given in this article, which stems from the international collaboration under IEA Wind TCP Tasks 25 and 53.

diversification↗

4U 1909+07: A Hidden Pearl

We present a detailed spectral and timing analysis of the High Mass X-ray Binary (HMXB) 4U 1909+07 with INTEGRAL and RXTE. 4U 1909+07 is a persistent accreting X-ray pulsar with a period of approximately 605 s. The period changes erratically consistent with a random walk expected for a wind accreting system. INTEGRAL detects the source with an average of 2.4 cps (corresponding to 15 mCrab), but sometimes exhibits flaring activity up to 50 cps (i.e. 300 mCrab). The strongly energy dependent pulse profile shows a double peaked structure at low energies and only a single narrow peak at energies above 20 keV. The phase averaged spectrum is well described by a powerlaw modified at higher energies by an exponential cutoff and photoelectric absorption at low energies. In addition at 6.4 keV a strong iron fluorescence line and at lower energies a black body component are present. We performed phase resolved spectroscopy to study the pulse phase dependence of the spectral parameters: while most spectral parameters are constant within uncertainties, the blackbody normalization and the cutoff folding energy vary strongly with phase.

Kreykenbohm, Ingo↗

USM3D-ME Analyses Performed in Support of a Wind Tunnel Test of a Boundary-Layer Ingestion Configuration

Boundary Layer Ingestion (BLI) has been proposed as a technology with the potential to decrease fuel burn. However, one major concern for BLI configurations is the potential degradation of the flow quality, both on the airframe and at the fan face, resulting from the tightly integrated propulsor. A wind tunnel test was performed in the National Transonic Facility (NTF) at the NASA Langley Research Center to investigate the flow quality ingested by a tail cone thruster configuration, similar to the Single Aisle Turboelectric Aircraft Concept with Aft Boundary Layer Ingestion (STARC-ABL). The wind tunnel model was a modified version of the Common Research Model (CRM) to include an aft-mounted, flow-through propulsor. The experimental data obtained from the wind tunnel test provide insight into the flow and enables an assessment of the accuracy of the USM3D-ME flow solver for predicting the flow at the fan face, which will be crucial for fan design purposes. Both grid refinement and turbulence model studies were performed for the Clean and Cruise MFP configurations at the condition corresponding to ReMAC = 5 million, Mach = 0.8, and alpha = 2 deg. The selected grid refinement level and turbulence model were then used to perform simulations over the range of conditions considered in the NTF wind tunnel test. The condition sweep comparisons illustrate favorable agreement with the experimental data over the entire range of conditions and for all Mass Flow Plug (MFP) configurations. The largest differences were observed for the Idle MFP configuration, with approximately 3% difference observed between USM3D-ME and the experimental data. Future work should investigate the impact of higher fidelity turbulence models and grid adaptation on the USM3D-ME predictions.

CRM↗

USM3D-ME Analyses Performed in Support of a Wind Tunnel Test of a Boundary-Layer Ingestion Configuration

Boundary Layer Ingestion (BLI) has been proposed as a technology with the potential to decrease fuel burn. However, one major concern for BLI configurations is the potential degradation of the flow quality, both on the airframe and at the fan face, resulting from the tightly integrated propulsor. A wind tunnel test was performed in the National Transonic Facility (NTF) at the NASA Langley Research Center to investigate the flow quality ingested by a tail cone thruster configuration, similar to the Single Aisle Turboelectric Aircraft Concept with Aft Boundary Layer Ingestion (STARC-ABL). The wind tunnel model was a modified version of the Common Research Model (CRM) to include an aft-mounted, flow-through propulsor. The experimental data obtained from the wind tunnel test provide insight into the flow and enables an assessment of the accuracy of the USM3D-ME flow solver for predicting the flow at the fan face, which will be crucial for fan design purposes. Both grid refinement and turbulence model studies were performed for the Clean and Cruise MFP configurations at the condition corresponding to ReMAC = 5 million, Mach = 0.8, and alpha = 2 deg. The selected grid refinement level and turbulence model were then used to perform simulations over the range of conditions considered in the NTF wind tunnel test. The condition sweep comparisons illustrate favorable agreement with the experimental data over the entire range of conditions and for all Mass Flow Plug (MFP) configurations. The largest differences were observed for the Idle MFP configuration, with approximately 3% difference observed between USM3D-ME and the experimental data. Future work should investigate the impact of higher fidelity turbulence models and grid adaptation on the USM3D-ME predictions.

CRM↗

Evaluation of a technique to generate artificially thickened boundary layers in supersonic and hypersonic flows

The feasibility of using a contoured honeycomb model to generate a thick boundary layer in high-speed, compressible flow was investigated. The contour of the honeycomb was tailored to selectively remove momentum in a minimum of streamwise distance to create an artificially thickened turbulent boundary layer. Three wind tunnel experiments were conducted to verify the concept. Results indicate that this technique is a viable concept, especially for high-speed inlet testing applications. In addition, the compactness of the honeycomb boundary layer simulator allows relatively easy integration into existing wind tunnel model hardware.

Porro, A. R.↗

Entry reaction control system propellant analysis. Flight control integration

The effects of winds, sideslip angle feedback, and the data reference (air or inertial) on the Reaction Control System (RCS) propellant requirements during entry were investigated. It was determined that in the presence of a 3 sigma crosswind an addition 188 pounds of RCS propellant was required for entry control which is within the present 200 pound allotment for winds. The absence of air data information does result in slightly higher RCS propellant demands.

Devall, O. R.↗

Hybrid power plant design for low-carbon hydrogen in the United States

In this study, we provide a nationwide techno-economic analysis of clean hydrogen production powered by a hybrid renewable energy plant for over 50,000 locations in the United States. We leverage the open-source Hybrid Optimization Performance Platform (HOPP) tool to simulate the hourly performance of an off-grid wind-solar plant integrated with a 1-GW polymer exchange membrane electrolyzer system. The levelized cost of hydrogen is calculated for varying technology costs, and tax credits to explore cost sensitivities independent of plant design, performance, and site selection. Our findings suggest that strategies for cost reduction include selecting sites with abundant wind resources, complementary wind and solar resources, and optimizing the sizing of wind and solar assets to maximize the hybrid plant capacity factor. These strategies are linked to increased hydrogen production and reduced electrolyzer stack replacements, thereby lowering the overall cost of hydrogen.

08 HYDROGEN↗

2022 Component Innovation Awardee: Windurance

Combining battery energy storage with distributed wind energy systems can increase production, ability to meet local electricity demands, interconnection capacity, and potential sales of surplus energy back to the grid, while reducing demand charges and the overall levelized cost of energy (LCOE). Energy storage options for distributed wind energy systems can vary widely in terms of power level and energy storage capacity, and their potential benefits depend on factors including wind resource, turbine design, connection requirements, use patterns, utility rates, and regulations. Windurance received a 2022 Competitiveness Improvement Project (CIP) funding award to add battery energy storage capabilities to the company's bidirectional DC converter. The energy storage component will complete a comprehensive portfolio of power conversion and control electronics that can be seamlessly integrated with distributed wind systems. The company received earlier CIP awards to fund prototype design and construction of wind turbine pitch actuators, inverters, and controllers.

CIP↗

Deployable Wind-Hybrid Power Systems for Defense and Disaster Response Applications

This report presents an analysis of the performance of deployable energy systems comprised of wind energy systems integrated with diesel generators, photovoltaic systems, and battery storage to meet the load requirements of a representative U.S. Army forward operating base. The analysis is conducted using HOMER, a microgrid analysis software that can search through a wide range of parameters to design and optimize microgrid power systems. The search parameters include the system architecture, the wind and solar resources, and the availability of diesel fuel. The results of the analysis measure the relative performance of the different systems and environments in terms of the overall transportation cost to deploy the system and the ability to provide resilience in terms of meeting mission critical loads.

02 PETROLEUM↗

Aero‐servo‐elastic co‐optimization of large wind turbine blades with distributed aerodynamic control devices

Abstract This work introduces automated wind turbine optimization techniques based on full aero‐servo‐elastic models and investigates the potential of trailing edge flaps to reduce the levelized cost of energy (LCOE) of wind turbines. The Wind Energy with Integrated Servo‐control (WEIS) framework is improved to conduct the presented research. Novel methods for the generic implementation and tuning of trailing edge flap devices and their controller are also introduced. Primary flap and controller parameters are optimized to demonstrate potential maximum blade tip deflection reductions of 21 % . Concurrent design optimization (i.e., co‐design) of a novel segmented wind turbine blade with trailing edge flaps and its controller is then conducted to demonstrate blade cost savings of 5 % . Additionally, rotor diameter co‐design optimization is demonstrated to reduce the LCOE by 1.3 % without significant load increases to the tower. These results demonstrate the efficacy of control co‐design optimization using trailing edge flaps, and the entirety of this work provides a foundation for numerous control co‐design‐oriented studies for distributed aerodynamic control devices.

17 WIND ENERGY↗

Hydrogen-Battery Hybrid Energy System on Repurposed Offshore Platforms for Efficient Clean-Energy Transition

Due to the rising global energy demand and enhanced awareness of the environmental impact of fossil fuels, the Gulf of Mexico, traditionally known for oil extraction, offers a distinct chance to repurpose the existing offshore infrastructure. With the depletion of oil reserves, it is feasible to adapt previously utilized floating platforms for extraction to generate renewable energy, specifically through wind-generated power and hydrogen production. This adaptation seeks to promote a transport system that is more ecologically friendly in the future. Offshore wind turbines serve as the main energy source, with help from battery storage and hydrogen production to enhance the overall system performance, hydrogen creation, fuel, and electricity delivery for sustainable energy production. The system is divided into two distinct cases, each evaluated for cost, performance, and feasibility, with a focus on minimizing both the Levelized Cost of Energy (LCOE) and the Levelized Cost of Hydrogen (LCOH). The first case examines the integration of offshore wind turbines with hydrogen production. Excess electricity generated by wind turbines is directed toward hydrogen production via electrolysis. The hydrogen produced can be used as fuel for vehicles or transported to the shore via pipelines. The second case investigates a technology that combines wind turbines with battery storage. The batteries possess an ability to supply electricity for a continuous duration of 4 hours maximum each day. The main objective is to reduce the LCOE by considering the battery's charging and discharging cycles, together with the uncertain attributes of wind power and battery deterioration. The produced energy can be distributed for onshore applications or utilized for the purpose of offsetting offshore loads such as subsea oil and gas production, transportation, etc. The offshore hydrogen-battery hybrid system is improved via three advanced algorithms, Particle Swarm Optimization (PSO), and Grey Wolf Optimizer (GWO). In Case 1, PSO improves hydrogen production by efficiently managing the electrolyzer’s power consumption, decreasing production costs significantly. Particle Swarm Optimization (PSO) is applied to improve the efficiency of the electrolyzer, reducing production costs and achieving an optimized CAPEX of $240.00 million (from an initial $300.00 million) and OPEX of $9.60 million per year. This system produces 4,720,000 kg of hydrogen annually, with a Levelized Cost of Hydrogen (LCOH) of $6.40/kg and an annual profit of $9.27 million. In Case 2, GWO effectively reduces the overall energy cost by improving the charge-discharge management of batteries, which extends battery life and optimizes their use. The second case focuses on integrating battery storage, optimized using the Grey Wolf Optimizer (GWO), which enhances battery charge-discharge cycles, extending battery life and lowering costs. This system achieves an optimized CAPEX of $204.80 million (from an initial $256.00 million) and OPEX of $9.29 million per year, producing 310883.39 MWh of electricity annually at a Levelized Cost of Energy (LCOE) of $86.13/MWh, with an annual profit of $6.25 million. The implementation of a comprehensive strategy results in a substantial reduction in costs, improved energy efficiency, and a dependable supply of both electric power and hydrogen, emphasizing the benefits of converting offshore oil platforms for clean energy transition. This study explores a clean strategy to enable cost-effective repurposing of offshore O&G platforms. Both cases highlight the economic and technical feasibility of transitioning offshore oil platforms to clean energy systems, demonstrating substantial cost reductions and reliable energy and hydrogen supplies for sustainable energy production.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Wind Turbine Rotor Design Optimization Using Importance Sampling: Preprint

Probabilistic methods are commonly adopted to estimate both ultimate and fatigue loads in wind turbines, and multiple papers have presented a variety of approaches. In contrast, system-level, integrated design optimization methods for wind turbines have so far relied on deterministic methods to estimate loads and deflections. This work aims at addressing this gap by adopting importance sampling to estimate ultimate blade deflection for use within a rotor design optimization. A comparison between the results of this approach against traditional approaches using deterministic load evaluations show that the probabilistic approach is more conservative and that the solutions found with deterministic approaches violate the probabilistic constraint on tip deflection between 13% and 17%. This highlights the importance of accurate load and deflection estimates and demonstrates that probabilistic approaches can be successfully integrated within a wind turbine design process despite the higher computational costs.

17 WIND ENERGY↗

Integration Time Required to Extract Accurate Data from Transonic Wind-Tunnel Tests

Because the forces and pressures on wind-tunnel models tested at transonic speeds are not steady, even for static aerodynamic tests, integration time is required to obtain data of acceptable accuracy. The integration time required for both static and dynamic tests is evaluated analytically and confirmed by experimental measurements. It is shown that, for static and dynamic tests, the accuracy obtained is a function of integration time, frequency of the signal, and the ratio of the dynamic amplitude to the full signal of interest. In addition, for the dynamic case, the frequency bandwidth used in analysis is important. Results of this study indicate that, for typical data accuracy desired from models in a large transonic wind tunnel (11- by 11-ft), up to the following integration times are required: static force and moment tests, 0.5 s; static pressure tests, 1 s; flutter tests, 30 to 60 s; and random-dynamic tests, 10 s.

Muhlstein, Lado, Jr.↗