Search NASA⌕ Search

SEARCH · Search NASA

Results for “X radiation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Complex Structural Disorder in a Polar Orthorhombic Perovskite Observed through the Maximum Entropy Method/Rietveld Technique

Ambient pressure stable perovskite oxides with all Bi3+ on the A-site are rare, with only four examples known. Due to the lone pair on Bi 3+ , these materials are seen as the best alternative to Pb-based piezoelectrics, which are used widely in society. The industry standard piezoelectric, Pb (Zr 1 – x Ti x )O 3 , relies on the [001] polarization of PbTiO 3 , but there are currently no ambient pressure stable Bi-based perovskites with this polarization vector, preventing the creation of an analogous system. We present the full structural analysis of the orthorhombic phase of (1 – x)Bi (Ti 3/8 Fe 2/8 Mg 3/8 )O 3 – x CaTiO 3 , which crystallizes in Pna2 1 symmetry with [001] polarization. This symmetry is rare and has only been reported twice for perovskites at ambient conditions. Analysis of maximum entropy method (MEM) models using synchrotron radiation powder X-ray diffraction reveals a disordered A-site configuration, and the MEM/Rietveld technique generates a structural model of this extreme disorder. Combined Rietveld analysis of X-ray and neutron diffraction data yields an accurate description of the local A-site configuration, which we use to understand our dielectric, ferroelectric, and piezoelectric measurements. These results give insight into how to stabilize this unique symmetry and inspire new design principles for Bi-based piezoelectrics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fluorescence-mediated postcollision interaction in x-ray photoionization of the Xe 𝐾 edge

Postcollision interaction (PCI) in near-threshold photoionization of the K shell of atomic Xe is investigated with hard-x-ray synchrotron radiation. Applying Auger electron spectroscopy, line-shape distortion is monitored in the K-L 2 → L 2 M 4,5 M 4,5 decay channel, where the initial K-L 2 (Kα 2 ) x-ray-emission step mediates the emission of the two continuum electrons. The K-edge result is compared to similar data obtained on direct L 2 M 4,5 M 4,5 decay at the L 2 edge without x-ray-emission. In conclusion, it is found that the evolution of the PCI shift with excess photon energy is very similar at both edges, but a subtle decrease in the PCI shift is observable at the K edge due to the effect of the ultrafast x-ray emission step delaying the PCI energy exchange by a few attoseconds.

74 ATOMIC AND MOLECULAR PHYSICS↗

Cadmium Magnesium Telluride for Next-Generation X-Ray Free Electron Laser, Synchrotron, and Many Other Applications

We developed a picosecond photodetector based on our Bridgman-grown and specially engineered cadmium magnesium telluride (Cd 1–x MgxTe) single crystal that is sensitive to both optical and X-ray pulses for coarse timing in free-electron laser applications. Cd 1–x MgxTe is a widebandgap semiconductor with potential applications, not only in optoelectronics, but also in particle physics as an intense pulse radiation detector for bremsstrahlung, X-ray/gamma-ray radiation, thermal neutrons, and medical imaging. For femtosecond optical and X-ray crosscorrelation, the material must have a very short lifetime, a condition that is opposite to that required for nuclear spectroscopy applications. At the same time, the material also needs to have a very low bulk leakage current, in the 10–90 nA range for voltages to even 1000 V. Hence, the ability to tailor or engineer the material is very crucial. Picosecond response and the crystal growth of this specially engineered Cd 1–x MgxTe material are presented. Furthermore, other characterization and transient measurements are discussed along with room-temperature semiconductor detector performance for other nuclear radiation detection applications.

36 MATERIALS SCIENCE↗

Flux and estimated spectra from a low-intensity laser-driven X-ray source

Laser-driven X-rays as probes for high-energy-density physics spans an extremely large parameter space with laser intensities varying by 8 orders of magnitude. We have built and characterized a soft X-ray source driven by a modest intensity laser of 4 × 10 13 W/cm 2 . Emitted X-rays were measured by diamond radiation detectors and a filtered soft X-ray camera. A material-dependence study on Al, Ti, stainless steel alloy 304, Fe, Cu and Sn targets indicated 5-μm-thick Cu foils produced the highest X-ray yield. X-ray emission in the laser direction and emission in the reverse direction depend strongly on the foil material and the thickness due to the opacity and hydrodynamic disassembly time. The time-varying X-ray signals are used to measure the material thinning rate and is found to be ~1.5 μm/ns for the materials tested implying thermal temperature around 0.6 eV. The X-ray spectra from Cu targets peaks at ~2 keV with no emission >4 keV and was estimated using images with eight different foil filters. One-dimensional hydrodynamic and spectral calculations using HELIOS-CR provide qualitative agreement with experimental results. Modest intensity lasers can be an excellent source for nanosecond bursts of soft X-rays.

47 OTHER INSTRUMENTATION↗

Correlative nano-imaging of metals and proteins in primary neurons by synchrotron X-ray fluorescence and STED super resolution microscopy: Experimental validation

It is becoming increasingly clear that biological metals such as iron, copper or zinc are involved in synaptic functions, and in particular in the mechanisms of synaptogenesis and subsequent plasticity. Understanding the role of metals on synaptic functions is a difficult challenge due to the very low concentration of these elements in neurons and to the submicrometer size of synaptic compartments. To address this challenge we have developed a correlative nano-imaging approach combining metal and protein detection. First, stimulated emission depletion (STED) microscopy, a super resolution optical microscopy technique, is applied to locate fluorescently labeled proteins. Then, synchrotron radiation induced X-ray fluorescence (SXRF) is performed on the same regions of interest, e.g. synaptic compartments. Here, we present here the principle scheme that allows this correlative nano-imaging and its experimental validation. We applied this correlative nano-imaging to the study of the physiological distribution of metals in synaptic compartments of primary rat hippocampal neurons. We thus compared the nanometric distribution of metals with that of synaptic proteins, such as PSD95 or cytoskeleton proteins. Compared to correlative imaging approaches currently used to characterize synaptic structures, such as electron microscopy correlated with optical fluorescence, our approach allows for ultra-sensitive detection of trace metals using highly focused synchrotron radiation beams. We provide proof-of-principle for correlative imaging of metals and proteins at the synaptic scale and discuss the present limitations and future developments in this area.

59 BASIC BIOLOGICAL SCIENCES↗

At-wavelength characterization of X-ray wavefronts in Bragg diffraction from crystals

The advent of next-generation synchrotron radiation sources and X-ray free-electron lasers calls for high-quality Bragg-diffraction crystal optics to preserve the X-ray beam coherence and wavefront. This requirement brings new challenges in characterizing crystals in Bragg diffraction in terms of Bragg-plane height errors and wavefront phase distortions. Here, a quantitative methodology to characterize crystal optics using a state-of-the-art at-wavelength wavefront sensing technique and statistical analysis is proposed. The method was tested at the 1-BM-B optics testing beamline at the Advanced Photon Source for measuring silicon and diamond crystals in a self-referencing single-crystal mode and an absolute double-crystal mode. The phase error sensitivity of the technique is demonstrated to be at the λ/100 level required by most applications, such as the characterization of diamond crystals for cavity-based X-ray free-electron lasers.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A MHz-repetition-rate hard X-ray free-electron laser driven by a superconducting linear accelerator

The European XFEL is a hard X-ray free-electron laser (FEL) based on a high-electron-energy superconducting linear accelerator. The superconducting technology allows for the acceleration of many electron bunches within one radio-frequency pulse of the accelerating voltage and, in turn, for the generation of a large number of hard X-ray pulses. In this paper, we report on the performance of the European XFEL accelerator with up to 5,000 electron bunches per second and demonstrating a full energy of 17.5 GeV. Feedback mechanisms enable stabilization of the electron beam delivery at the FEL undulator in space and time. The measured FEL gain curve at 9.3 keV is in good agreement with predictions for saturated FEL radiation. Hard X-ray lasing was achieved between 7 keV and 14 keV with pulse energies of up to 2.0 mJ. Using the high repetition rate, an FEL beam with 6 W average power was created.

43 PARTICLE ACCELERATORS↗

X-ray Absorption Spectroscopy of Dilute Metalloenzymes at X-ray Free-Electron Lasers in a Shot-by-Shot Mode

X-ray absorption spectroscopy (XAS) of 3d transition metals provides important electronic structure information for many fields. However, X-ray-induced radiation damage under physiological temperature has prevented using this method to study dilute aqueous systems, such as metalloenzymes, as the catalytic reaction proceeds. Here we present a new approach to enable operando XAS of dilute biological samples and demonstrate its feasibility with K-edge XAS spectra from the Mn cluster in photosystem II and the Fe–S centers in photosystem I. This approach combines highly efficient sample delivery strategies and a robust signal normalization method with high-transmission Bragg diffraction-based spectrometers at X-ray free-electron lasers (XFELs) in a damage-free, shot-by-shot mode. These photon-out spectrometers have been optimized for discriminating the metal Mn/Fe Kα fluorescence signals from the overwhelming scattering background present on currently available detectors for XFELs that lack suitable energy discrimination. We quantify the enhanced performance metrics of the spectrometer and discuss its potential applications for acquiring time-resolved XAS spectra of biological samples during their reactions at XFELs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

X-ray induced grain boundary formation and grain rotation in Bi 2 Se 3

Optimizing grain boundary characteristics in polycrystalline materials can improve their properties. Many processing methods have been developed for grain boundary manipulation, including the use of intense radiation in certain applications. Here, in this work, we used X-ray free electron laser pulses to irradiate single-crystalline bismuth selenide (Bi 2 Se 3 ) and observed grain boundary formation and subsequent grain rotation in response to the X-ray radiation. Our observations with simultaneous transmission X-ray microscopy and X-ray diffraction demonstrate how intense X-ray radiation can rapidly change size and texture of grains.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Soft X-ray and EUV emission spectra of beryllium plasma produced by neodymium-glass laser radiation with broad frequency and angular spectra

We present the results of an experimental study of soft X-ray (SXR) and extreme ultraviolet emission spectra of the plasma produced by exposing a plane solid beryllium target to laser radiation with broad frequency and angular spectra. SXR lines up to 1s – 9p of Be IV as well as the plasma continuum are recorded for a laser focal-spot intensity of 5.3 × 10{sup 13} W cm{sup −2}. To model the SXR beryllium plasma spectra, simulations are carried out using the INDHAUS programme and the FLYCHK code in the framework of local thermodynamic equilibrium model, which agree nicely with experimentally obtained results. (laser plasma)

36 MATERIALS SCIENCE↗

X-ray topographic study of Bridgman-grown CdZnTeSe

We have characterized the structural quality of Cd 0.9 Zn 0.1 Te 0.93 Se 0.07 ingot grown by the vertical Bridgman growth technique. The structural quality of Cd 0.9 Zn 0.1 Te 0.93 Se 0.07 ingot along the length was investigated via X-ray topography in the reflection mode using a white beam synchrotron radiation source. The X-ray topography data revealed the presence of very few sub grain boundaries and no sub-grain boundary network for the CdZnTeSe samples used in this study.

36 MATERIALS SCIENCE↗

Sulphur variations in annually layered stalagmites using benchtop micro-XRF

Variation of sulphur in annually laminated stalagmites can be used to infer the impact of past volcanic activities, anthropogenic pollution, and climate change due to increased bushfire activity. The synchrotron radiation micro-X-Ray fluorescence (SR-XRF) microprobe is a powerful tool to analyse and image sulphur recorded in stalagmites with micrometre resolution. However, access to SR-XRF beamlines can be limited, so researchers must select the most promising stalagmites for imaging. Benchtop micro-XRF is an effective tool for trace elemental analysis of speleothem samples and is a candidate for routine laboratory measurement of sulphur along stalagmite laminae and screening for SR-XRF. Here, this study describes a protocol using matrix-matched standards to measure annual variations of sulphur at trace to percent level along the laminae of two Western Australian stalagmites, one of which already having been analysed using SR-XRF. Parameters that affected quantitation include X-ray tube voltage and current, spot size of the X-ray beam and stalagmite surface roughness and porosity. The use of a 20 μm X-ray spot size provides sub-annual spatial resolution that can be completed in an overnight scan. The features in a 1000 point micro-XRF analysis of sulphur along a 20 mm transect show good consistency with SR-XRF microprobe data. Micro-XRF mapping was also performed to produce chemical images on the stalagmite and compared with Raman and X-ray diffraction (XRD) to confirm that the stalagmite is exclusively calcite, with no aragonite, and that the source of sulphur in the samples was gypsum and anhydrite. Regions of very high sulphur in the micro-XRF maps were found to be artefacts due to diffraction of the incident beam but these could be efficiently removed by using a multiple point statistics approach to produce a clean image suitable for analysis of the laminae. This work shows the potential of micro-XRF for routine analysis of sulphur in stalagmites, and to streamline sample characterisation before SR-XRF imaging.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Scalable Freeze-Tape-Casting Fabrication and Pore Structure Analysis of 3D LLZO Solid-State Electrolytes

Nonflammable solid-state electrolytes can potentially address the reliability and energy density limitations of lithium-ion batteries. Garnet-structured oxides such as Li 7 La 3 Zr 2 O 12 (LLZO) are some of the most promising candidates for solid-state devices. Here, three-dimensional (3D) solid-state LLZO frameworks with low tortuosity pore channels are proposed as scaffolds, into which active materials and other components can be infiltrated to make composite electrodes for solid-state batteries. To make the scaffolds, we employed aqueous freeze tape casting (FTC), a scalable and environmentally friendly method to produce porous LLZO structures. Using synchrotron radiation hard X-ray microcomputed tomography, we confirmed that LLZO films with porosities of up to 75% were successfully fabricated from slurries with a relatively wide concentration range. The acicular pore size and shape at different depths of scaffolds were quantified by fitting the pore shapes with ellipses, determining the long and short axes and their ratios, and investigating the equivalent diameter distribution. The results show that relatively homogeneous pore sizes and shapes were sustained over a long range along the thickness of the scaffold. Additionally, these pores had low tortuosity and the wall thickness distributions were found to be highly homogeneous. These are desirable characteristics for 3D solid electrolytes for composite electrodes, in terms of both the ease of active material infiltration and also minimization of Li diffusion distances in electrodes. The advantages of the FTC scaffolds are demonstrated by the improved conductivity of LLZO scaffolds infiltrated with poly(ethylene oxide)/lithium bis(trifluoromethanesulfonyl)imide (PEO/LITFSI) compared to those of PEO/LiTFSI films alone or composites containing LLZO particles.

36 MATERIALS SCIENCE↗

Revolutionizing Lithium Storage Capabilities in TiO 2 by Expanding the Redox Range

TiO 2 is a widely recognized intercalation anode material for lithium-ion batteries (LIBs), yet its practical capacity is kinetically constrained due to sluggish lithium-ion diffusion, leading to a lithiation number of less than 1.0 Li + (336 mAh g -1 ). Here, the growth of TiO 2 crystallites is restrained by integrating Si into the TiO 2 framework, thereby enhancing the charge transfer and creating additional active sites potentially residing at grain boundaries for Li + storage. This strategy is corroborated by the expanded redox range of Ti, as thoroughly demonstrated via synchrotron radiation-based X-ray spectroscopy and Cs-corrected electron microscopy. Consequently, when deployed for lithium storage, the tailored material achieves an extraordinarily high reversible capacity of 559 mAh g -1 , 116% of the theoretical maximum of 483 mAh g -1 calculated based on all active species, while simultaneously retaining superior rate capability and robust cycling stability. Further, this work offers fresh perspectives on the revitalization of traditional electrode materials to achieve enhanced capacities.

25 ENERGY STORAGE↗

Design of a robot-automated flat plate/reflection geometry x-ray diffraction setup for accelerated materials discovery and structural screening

Here, we report the design, construction, and automation of a flat plate sample loading, alignment, and data acquisition system for X-ray diffraction measurements in reflection geometry implemented at the Stanford Synchrotron Radiation Lightsource. The system is built onto a single platform, enabling facile transferability, and is compartmentalized into sample storage, sample transfer, and sample position/alignment segments. The core feature of this system is a six-axis robotic arm that offers a large range of highly reproducible and programable movements. The degrees of freedom of the robot arm enable adaptability in which movements can be modified to fit various beamline environments and sample configurations. Samples are housed on 3D printed sample mounts, which are arranged onto a 6 × 2 array of sample cassettes capable of holding 7 samples. Using sample mounts designed for solid oxide electrolysis button cells (SOECs), the maximum tray capacity is 84 samples, which can be aligned and run in ~ 24 hours with long exposure scans. The sample array is additionally capable of accommodating a range of sample sizes and geometries due to the rapid 3D printed fabrication. The components of the setup will be described in detail and performance will be demonstrated with a set of representative SOEC and XRD standard samples. Opportunities for future developments and integration with the automated setup are summarized.

08 HYDROGEN↗

Controlled molecule injector for cold, dense, and pure molecular beams at the European x-ray free-electron laser

A permanently available molecular-beam injection setup for controlled molecules (COMO) was installed and commissioned at the small quantum systems (SQS) instrument at the European x-ray free-electron laser (EuXFEL). A b-type electrostatic deflector allows for pure state-, size-, and isomer-selected samples of polar molecules and clusters. The source provides a rotationally cold (T ≈ 1 K) and dense (ρ ≈ 10 8 cm −3 ) molecular beam with pulse durations up to 100 µs generated by a new version of the Even-Lavie valve. Here, a performance overview of the COMO setup is presented along with characterization experiments performed both with an optical laser at the Center for Free-Electron-Laser Science and with x rays at EuXFEL under burst-mode operation. COMO was designed to be attached to different instruments at the EuXFEL, in particular, the SQS and single particles, clusters, and biomolecules (SPB) instruments. This advanced controlled-molecules injection setup enables x-ray free-electron laser studies using highly defined samples with soft and hard x-ray FEL radiation for applications ranging from atomic, molecular, and cluster physics to elementary processes in chemistry and biology.

He, Lanhai↗