Search NASA⌕ Search

SEARCH · Search NASA

Results for “X-ray instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Testing and Characterization to Develop a Mechanistic Explanation for Unsaturated Drift of Fiber Optic Sensors during High-Dose Irradiation

The primary limitation for any optical fiber-based sensor for nuclear reactor applications is radiation-induced attenuation (RIA) of the transmitted and/or reflected signals. Based on several recent studies, RIA is tolerable for some fused silica optical fibers with the proper choice of sensing wavelength and fiber dopants. For extreme temperature applications (> 1000°C), sapphire optical fibers have been proposed; however, recent optical transmission measurements performed on bulk sapphire samples showed prohibitively large RIA. For some sensors, radiation-induced dimensional changes in the fiber materials can also cause significant drift. Moreover, the drift that was observed in numerous experiments performed in the High Flux Isotope Reactor (HFIR), the Advanced Test Reactor, the Massachusetts Institute of Technology Reactor, and other international facilities far exceeded what would be expected based on compaction of fused silica glass. Clearly, additional work is needed to better understand the origins of both RIA and radiation-induced drift in both silica and sapphire optical fiber-based sensors before these sensors can be reliably deployed for nuclear applications. This work evaluated the underlying mechanisms that may be responsible for RIA and drift in silica and sapphire materials. First, detailed characterization was performed on bulk fused silica glass samples that were previously irradiated to different neutron fluences at different temperatures to better understand the structural changes that drive radiation-induced drift in the absence of coating effects that are discussed later. Results show that the non-monotonic compaction that occurs with increasing neutron fluence continues up to fast neutron fluences approaching 10 22 n/cm 2 , which has important implications for physics-based models that may be used to compensate for the sensor drift. Initial Raman spectroscopy and synchrotron x-ray diffraction provide insights into the nature of the structural changes. Next, detailed characterizations were performed on silica fibers with various coatings that were subjected to several different thermal treatments. The hypothesis is that the coatings convert to carbon-rich materials that compact under irradiation, putting a large compressive strain on the fiber. Out-of-pile testing confirms that both polyimide and acrylate fiber coatings convert to glassy carbon (GC) materials when heated under inert conditions, and the degree of order (i.e., graphitization) increases with increasing temperature. The results provide increasingly strong evidence that the combination of polymeric coatings and inert (or vacuum) conditions render fiber optic sensors susceptible to significant radiation-induced drift that would not otherwise exist in uncoated fibers. Finally, transmission electron microscopy was performed on bulk sapphire samples that were irradiated to two neutron fluences at different temperatures to gain insights into the potential mechanisms driving the prohibitive RIA at higher neutron fluences and temperatures. Contrary to previous hypotheses, results show that scattering from radiation-induced voids cannot explain the observed RIA. Similarly, models for scattering losses from dislocation loops also do not agree with the experimental results. Instead, fitting to the experimental data shows that increased absorption from aluminum vacancy centers is the most likely explanation for the the prohibitively large RIA that was observed at high irradiation temperature and dose. In addition, the voids that formed in these single-crystal samples were found to align along the basal plane (a-axis) as opposed to that seen in previous observations of c-axis alignment in polycrystalline samples, which could have important implications for anisotropic swelling and other phenomena that could affect sensor performance at high neutron fluence.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantitative radiography for determining density fluctuations in HED experiments

We have developed a method to extract density fluctuation measurements from x-ray radiographs of high-energy density (HED) instability growth and turbulence experiments. We use this information to calculate density fluctuation statistics for constraining the performance of turbulent mix models in HED systems. The density calculation combines image filtering, removal of systemic effects such as backlighter variation, calculation of transmission across multiple materials, and use of tracer materials to generate an approximate single-material density field. From the density map, we calculate both average density and a variance-like moment b (density-specific-volume covariance), which we compare to our models. We infer both quantities from a single image, which is significantly more information than the historic single scalar mix width measurements. We also develop a method of analyzing simulation outputs that incorporate both the density fluctuation metric from a turbulence model and the bulk material maps from the hydrodynamic code. This analysis helps address the question of how to initialize the simulations for best comparison to data from systems with large separations of scale in the mixing perturbation initial condition. We find that our data analysis method yields 1D average density and b curves with similar morphology and amplitudes as those from preliminary simulation comparisons.

47 OTHER INSTRUMENTATION↗

Testing and Characterization to Develop a Mechanistic Explanation for Unsaturated Drift of Fiber Optic Sensors during High-Dose Irradiation

The primary limitation for any optical fiber-based sensor for nuclear reactor applications is radiation-induced attenuation (RIA) of the transmitted and/or reflected signals. Based on several recent studies, RIA is tolerable for some fused silica optical fibers with the proper choice of sensing wavelength and fiber dopants. For extreme temperature applications (> 1000°C), sapphire optical fibers have been proposed; however, recent optical transmission measurements performed on bulk sapphire samples showed prohibitively large RIA. For some sensors, radiation-induced dimensional changes in the fiber materials can also cause significant drift. Moreover, the drift that was observed in numerous experiments performed in the High Flux Isotope Reactor (HFIR), the Advanced Test Reactor, the Massachusetts Institute of Technology Reactor, and other international facilities far exceeded what would be expected based on compaction of fused silica glass. Clearly, additional work is needed to better understand the origins of both RIA and radiation-induced drift in both silica and sapphire optical fiber-based sensors before these sensors can be reliably deployed for nuclear applications. This work evaluated the underlying mechanisms that may be responsible for RIA and drift in silica and sapphire materials. First, detailed characterization was performed on bulk fused silica glass samples that were previously irradiated to different neutron fluences at different temperatures to better understand the structural changes that drive radiation-induced drift in the absence of coating effects that are discussed later. Results show that the non-monotonic compaction that occurs with increasing neutron fluence continues up to fast neutron fluences approaching 10 22 n/cm 2 , which has important implications for physics-based models that may be used to compensate for the sensor drift. Initial Raman spectroscopy and synchrotron x-ray diffraction provide insights into the nature of the structural changes. Next, detailed characterizations were performed on silica fibers with various coatings that were subjected to several different thermal treatments. The hypothesis is that the coatings convert to carbon-rich materials that compact under irradiation, putting a large compressive strain on the fiber. Out-of-pile testing confirms that both polyimide and acrylate fiber coatings convert to glassy carbon (GC) materials when heated under inert conditions, and the degree of order (i.e., graphitization) increases with increasing temperature. The results provide increasingly strong evidence that the combination of polymeric coatings and inert (or vacuum) conditions render fiber optic sensors susceptible to significant radiation-induced drift that would not otherwise exist in uncoated fibers. Finally, transmission electron microscopy was performed on bulk sapphire samples that were irradiated to two neutron fluences at different temperatures to gain insights into the potential mechanisms driving the prohibitive RIA at higher neutron fluences and temperatures. Contrary to previous hypotheses, results show that scattering from radiation-induced voids cannot explain the observed RIA. Similarly, models for scattering losses from dislocation loops also do not agree with the experimental results. Instead, fitting to the experimental data shows that increased absorption from aluminum vacancy centers is the most likely explanation for the the prohibitively large RIA that was observed at high irradiation temperature and dose. In addition, the voids that formed in these single-crystal samples were found to align along the basal plane (a-axis) as opposed to that seen in previous observations of c-axis alignment in polycrystalline samples, which could have important implications for anisotropic swelling and other phenomena that could affect sensor performance at high neutron fluence.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

FPGA-accelerated SpeckleNN with SNL for real-time X-ray single-particle imaging

We present the implementation of a specialized version of our previously published unified embedding model, SpeckleNN, for real-time speckle pattern classification in X-ray Single-Particle Imaging (SPI), using the SLAC Neural Network Library (SNL) on an FPGA platform. This hardware realization transitions SpeckleNN from a prototypic model into a practical edge solution, optimized for running inference near the detector in high-throughput X-ray free-electron laser (XFEL) facilities, such as those found at the Linac Coherent Light Source (LCLS). To address the resource constraints inherent in FPGAs, we developed a more specialized version of SpeckleNN. The original model, which was designed for broader classification across multiple biological samples, comprised ~5.6 million parameters. The new implementation, while reducing the parameter count to 64.6K (a 98.8% reduction), focuses on maintaining the model's essential functionality for real-time operation, achieving an accuracy of 90%. Furthermore, we compressed the latent space from 128 to 50 dimensions. This implementation was demonstrated on the KCU1500 FPGA board, utilizing 71% of available DSPs, 75% of LUTs, and 48% of FFs, with an average power consumption of 9.4W according to the Vivado post-implementation report. The FPGA performed inference on a single image with a latency of 45.015 microseconds at a 200 MHz clock rate. In comparison, running the same inference on an NVIDIA A100 GPU resulted in an average power consumption of ~73W and an image processing latency of around 400 microseconds. Our FPGA-accelerated version of SpeckleNN demonstrated significant improvements, achieving an 8.9 × speedup and a 7.8 × reduction in power consumption compared to the GPU implementation. Key advancements include model specialization and dynamic weight loading through SNL, which eliminates the need for time-consuming FPGA design re-synthesis, allowing fast and continuous deployment of models (re)trained online. These innovations enable real-time adaptive classification and efficient vetoing of speckle patterns, making SpeckleNN more suited for deployment in XFEL facilities. This implementation has the potential to significantly accelerate SPI experiments and enhance adaptability to evolving experimental conditions.

47 OTHER INSTRUMENTATION↗

Tracking oxygen vacancy migration in memristor devices using operando hard X-ray photoelectron spectroscopy

Fabrication of ultrathin (sub-2 nm) oxide semiconductor memristors poses the fundamental challenge of achieving oxide growth with atomic precision in terms of electronic structure and defect formation. Recently, ultrathin memristors consisting of bilayers of mixed Al 2 O 3 and MgO atomic layers were fabricated using an in vacuo atomic layer deposition process. This approach offers a unique platform for precise atomic control of oxygen vacancies in the device in which the vacancies are introduced by placing MgO atomic layers between pristine Al 2 O 3 layers. In this work, we present a systematic operando Hard X-ray PhotoElectron Spectroscopy (HAXPES) study of the switching of such memristors, combined with complementary current-voltage and capacitance-voltage (C-V) measurements. We used a memristor stack of Al 2 O 3 /MgO atomic layers, with the MgO-containing oxide deposited on the bottom Al metal electrode and a pure Al 2 O 3 layer below the top Pd electrode. HAXPES analysis shows a substantial change in the chemical shift of the Aluminum oxide when switching between the ”OFF” and ”ON” states indicative of a redistribution of oxygen vacancies in the device active layer. Interestingly, subsequent switching to the OFF state shows hysteretic behavior indicating the retention of some oxygen vacancies in the top Al 2 O 3 layer. This vacancy retention can be correlated with the stochastic behavior of the switching voltage observed in these devices. C–V measurements show a clear frequency-dependent response in the OFF state, consistent with enhanced polarization and vacancy trapping at low frequencies.

47 OTHER INSTRUMENTATION↗

Spectrotemporal Shaping of Attosecond X-Ray Pulses with a Fresh-Slice Free-Electron Laser

We propose a scheme allowing coherent shaping, i.e., controlling both the amplitude and phase, of attosecond x-ray pulses at free-electron lasers. Here, we show that by seeding an FEL with a short coherent seed that overfills the amplification bandwidth, one can shape the Wigner function of the pulse by controlling the undulator taper profile. The examples of controllable pulse pairs and trains, as well as isolated spectrotemporally shaped pulses with very broad bandwidths are examined in detail. Existing attosecond XFELs can achieve these experimental conditions in a two-stage cascade, in which the seed is generated by a short current spike in an electron bunch and shaped in an unspoiled region within the same bunch. We experimentally demonstrate the production and control of phase-stable pulse trains using this method at the Linac Coherent Light Source II.

47 OTHER INSTRUMENTATION↗

First high peak and average power single-pass THz free-electron laser in operation

We report on the operation of the first high peak and average power single-pass terahertz free-electron laser (THz FEL) based on a high-brightness photoinjector for developing a THz source for pump-probe experiments at advanced x-ray FELs (XFELs). Electron beams with 17 MeV/c momentum and charge up to 2.4 nC were used to generate narrow-band 3 THz radiation with pulse energies of more than 0.1 mJ. The novelty of the realized method is that the undulator radiation by electron beams is much longer than the radiation wavelength, with FEL starting from coherent beam contribution rather than shot noise. This proved to be not a simple scaling of the XFEL mechanism due to the significant role of the bunching factor in the considered case.

47 OTHER INSTRUMENTATION↗

Attosecond inner-shell lasing at ångström wavelengths

Since the invention of the laser, nonlinear effects such as filamentation, Rabi cycling and collective emission have been explored in the optical regime, leading to a wide range of scientific and industrial applications. X-ray free-electron lasers (XFELs) have extended many optical techniques to X-rays for their advantages of ångström-scale spatial resolution and elemental specificity. An example is XFEL-driven inner-shell Kα 1 (2p 3/2 → 1s 1/2 ) X-ray lasing in elements ranging from neon to copper, which has been used for nonlinear spectroscopy and development of new X-ray laser sources. Here, in this study, we show that strong lasing effects similar to those in the optical regime can occur at 1.5–2.1 Å wavelengths during high-intensity (>10 19 W cm −2 ) XFEL-driven Kα 1 lasing of copper and manganese. Depending on the temporal XFEL pump pulse substructure, the resulting X-ray pulses (about 10 6 −10 8 photons) can exhibit strong spatial inhomogeneities and spectral splitting, inhomogeneities and broadening. Three-dimensional Maxwell–Bloch calculations show that the observed spatial inhomogeneities result from X-ray filamentation and that the broad spectral features are driven by sub-femtosecond Rabi cycling. Our simulations indicate that these X-ray pulses can have pulse lengths of less than 100 attoseconds and coherence properties that provide opportunities for quantum X-ray optics applications.

47 OTHER INSTRUMENTATION↗

Full-polarization millimeter wavelength variability of Sagittarius A * during the 2018 EHT campaign

Context. Sagittarius A* (Sgr A*), the supermassive black hole at the center of the Milky Way, provides a unique laboratory to study accretion dynamics and plasma processes near the event horizon. Aims. We investigated the variability and polarization properties of Sgr A* using ALMA observations during the 2018 Event Horizon Telescope campaign. Methods. We analyzed high-cadence full-polarization light curves from ALMA at millimeter wavelengths, performed time-series analysis, and investigated the temporal behavior during an X-ray flare observed by Chandra on 2018 April 24. The variability characteristics are compared with expectations from standard accretion flow models. Results. We find low variability in total intensity (σ/μ < 10%), but significantly higher variability in linear and circular polarization (∼30% and ∼50%, respectively). A time-series analysis reveals red-noise variability, with power spectral densities between −2 and −3 across all Stokes parameters. Polarized intensity shows stable intra-day timescales, while total intensity exhibits more variable timescales, suggesting distinct emission regions, with polarization likely arising from a coherent structure. On April 24, a statistically significant inter-band delay in polarized intensity coincides with a near-simultaneous X-ray and millimeter peak that deviates from the typical delayed flare scenario. This event also features enhanced millimeter variability and coherent polarization loop evolution. The observed simultaneity challenges standard models of transient synchrotron emission with cooling delays, favoring instead a scenario of continuous energy injection in an optically thin region. Conclusions. Our results offer new constraints on the physical mechanisms driving variability in Sgr A*, and provide key observational input for refining theoretical models of accretion and plasma behavior in the vicinity of supermassive black holes.

Galaxy: center↗

The X-ray Integral Field Unit at the end of the Athena reformulation phase

The Athena mission entered a redefinition phase in July 2022, driven by the imperative to reduce the mission cost at completion for the European Space Agency below an acceptable target, while maintaining the flagship nature of its science return. This notably called for a complete redesign of the X-ray Integral Field Unit (X-IFU) cryogenic architecture towards a simpler active cooling chain. Passive cooling via successive radiative panels at spacecraft level is now used to provide a 50 K thermal environment to an X-IFU owned cryostat. 4.5 K cooling is achieved via a single remote active cryocooler unit, while a multi-stage Adiabatic Demagnetization Refrigerator ensures heat lift down to the 50 mK required by the detectors. Amidst these changes, the core concept of the readout chain remains robust, employing Transition Edge Sensor microcalorimeters and a SQUID-based Time-Division Multiplexing scheme. Noteworthy is the introduction of a slower pixel. This enables an increase in the multiplexing factor (from 34 to 48) without compromising the instrument energy resolution, hence keeping significant system margins to the new 4 eV resolution requirement. This allows reducing the number of channels by more than a factor two, and thus the resource demands on the system, while keeping a 4’ field of view (compared to 5’ before). Here, in this article, we will give an overview of this new architecture, before detailing its anticipated performances. Finally, we will present the new X-IFU schedule, with its short term focus on demonstration activities towards a mission adoption in early 2027.

Peille, Philippe [Centre National d’Etudes Spatial↗

Oxidation Temperature-Dependent Electrochemical Doping of WO 3 Deposited via Atomic Layer Deposition

Silicon-based photoelectrochemical devices show promise for the performance of light-driven CO 2 reduction but suffer from instability under photoelectrochemical conditions relevant to CO 2 reduction. Coating silicon electrodes with thin layers of metal oxides has shown promise to passivate unstable silicon surfaces, and many different metal oxides can be deposited on silicon using various techniques. In this study, we investigate the fundamental photoelectrochemical performance of WO 3 -coated silicon photoelectrodes, which were generated by oxidation of W-metal films deposited via atomic layer deposition on both degenerately doped (nSi + ) and low-doped (pSi) silicon. Two different oxidation temperatures were investigated (400 and 600 °C), and it was found that the monoclinic phase of WO 3 predominates at both temperatures but that more grain boundaries are present in the 600 °C film. From X-ray photoelectron spectroscopy, the stoichiometry of both films was found to be 1:3 W:O, and low electron energy loss experiments indicate band gaps of 3.0 and 3.1 eV for 400 and 600 °C films, respectively. Cyclic voltammetry experiments showed that the electron transfer kinetics increased after continued redox cycling, particularly for the material produced at 400 °C. X-ray photoelectron spectra suggest that the observed increase in electrode conductivity is due to the formation of oxygen vacancies in the film. Electrochemical impedance spectroscopy indicated that charge transport through the films was impacted by the grain boundaries that formed during oxidation of the film. Photoelectrochemical studies on pSi/WO 3 electrodes were highly variable, only producing a photocurrent and photovoltage with some samples. Our best sample, formed at 400 °C, produced a photovoltage of 180 mV, which is lower than what has previously been reported for WO 3 -coated silicon (500 mV). We hypothesize that the variability in photoelectrochemical experiments arose from a roughened WSiO x interface that is generated during film preparation. WO 3 shows promise as a metal oxide coating for silicon, but our results suggest that formation of a high-quality interface between Si and WO 3 is vital for best performance.

Charge transfer↗

Characterization of the response of radiochromic film to quasi-monoenergetic x rays through a cross-calibration with image plates

Radiochromic film (RCF) and image plates (IPs) are both commonly used detectors in diagnostics fielded at inertial confinement fusion (ICF) and high-energy-density physics (HEDP) research facilities. Due to the intense x-ray background in all ICF/HEDP experiments, accurately calibrating the optical density of RCF as a function of x-ray dose, and the photostimulated luminescence per photon of IPs as a function of x-ray energy, is necessary for interpreting experimental results. Various measurements of the sensitivity curve of different IPs to x rays have been performed [Izumi et al., Proc. SPIE 8850, 885006 (2013) and Rosenberg et al., Rev. Sci. Instrum. 90(1), 013506 (2019)]; however, calibrating RCF is a tedious process that depends on factors such as the orientation in which the RCF is scanned in the film scanner and the batch of RCF used. These issues can be mitigated by cross-calibrating RCF with IPs to enable the use of IPs for the determination of dose on the RCF without scanning the RCF. Here, the first cross-calibration of RCF with IPs to quasi-monoenergetic titanium, copper, and molybdenum K-line x rays is presented. It is found that the IP-inferred dose rates on the RCF for the Ti and Mo x rays agree well with the measured dose rates, while the IP-inferred dose rate for the Cu x rays is larger than the measured dose rate by ∼2×. Explanations for this discrepancy and plans for future work are discussed.

Instruments & Instrumentation↗

Characterization of the image plate multi-scan response to mono-energetic x-rays

Image plates (IPs), or phosphor storage screens, are a technology employed frequently in inertial confinement fusion (ICF) and high energy density plasma (HEDP) diagnostics because of their sensitivity to many types of radiation, including, x rays, protons, alphas, beta particles, and neutrons. Prior studies characterizing IPs are predicated on the signal level remaining below the scanner saturation threshold. Since the scanning process removes some signal from the IP via photostimulated luminescence, repeatedly scanning an IP can bring the signal level below the scanner saturation threshold. This process, in turn, raises concerns about the signal response of IPs after an arbitrary number of scans and whether such a process yields, for example, a constant ratio of signal between the nth and n + 1st scan. Here, the sensitivity of IPs is investigated when scanned multiple times. It is demonstrated that the ratio of signal decay is not a constant with the number of scans and that the signal decay depends on the x-ray energy. As such, repeatedly scanning an IP with a mixture of signal types (e.g., x ray, neutron, and protons) enables ICF and HEDP diagnostics employing IPs to better isolate a particular signal type.

Instruments & Instrumentation↗

Characterization of the Cherenkov Photon Background for Low-noise Silicon Detectors in Space

Future space observatories that seek to perform imaging and spectroscopy of faint astronomical sources will require ultra-low-noise detectors that are sensitive over a broad wavelength range. Silicon charge-coupled devices (CCDs), such as EMCCDs, skipper CCDs, multi-amplifier sensing CCDs, and single-electron sensitive read out CCDs have demonstrated the ability to detect and measure single photons from X-ray energies to near the silicon band gap (∼1.1 μm), making them candidate technologies for this application. Here, in this context, we study a relatively unexplored source of low-energy background coming from Cherenkov radiation produced by energetic cosmic rays traversing a silicon detector. We present a model for Cherenkov photon production and absorption that is calibrated to laboratory data, and we use this model to characterize the residual background rate for ultra-low-noise silicon detectors in space. We study how the Cherenkov background rate depends on detector thickness, variations in solar activity, and the contribution of heavy cosmic ray species (Z > 2). We find that for thick silicon detectors, such as those required to achieve high quantum efficiency at long wavelengths, the rate of cosmic-ray-induced Cherenkov photon production is comparable to other detector and astrophysical backgrounds. We apply our Cherenkov background model to simulated spectroscopic observations of extra-solar planets, and we find that thick detectors continue to outperform their thinner counterparts at longer wavelengths despite a larger Cherenkov background rate. Furthermore, we find that minimal masking of cosmic-ray tracks continues to maximize the signal-to-noise ratio of very faint sources despite the existence of extended halos of Cherenkov photons.

Astronomical detectors↗

The pathfinder X-Ray axion telescope for the International Axion Observatory (IAXO) and axion searches at the CERN Axion Solar Telescope (CAST)

The axion, a hypothetical pseudo-scalar particle proposed by Peccei and Quinn to resolve the strong CP problem in quantum chromodynamics, remains one of the most compelling dark matter candidates. Axions and Axion-Like Particles (ALPs) are characterized by a broad and largely unconstrained parameter space in mass and coupling strength, motivating extensive experimental searches. The International Axion Observatory (IAXO) is a next-generation axion helioscope designed to achieve over an order of magnitude improvement in sensitivity to the axion-photon coupling constant gaγ relative to previous experiments such as the CERN Axion Solar Telescope (CAST). IAXO will employ large-scale superconducting magnets, precision x-ray optics, and ultra-low-background detectors to search for solar axions produced primarily via the Primakoff effect. This work presents the design and performance of the IAXO pathfinder x-ray optic, a technological demonstrator that validated the optical concepts for IAXO through axion searches at CAST. Comprehensive ray-tracing simulations and experimental measurements were conducted to assess the optic's effective area, detection efficiency, and background suppression capabilities. Deployed at CAST in conjunction with Micromegas and GridPix detectors, the Pathfinder demonstrated record-setting sensitivity to both gaγ and the axion-electron coupling gae, establishing the most stringent laboratory constraints on solar axions to date. These results confirm the viability of the IAXO optical design and detector concept, providing a critical technological benchmark that informs the ongoing development of the BabyIAXO and full-scale IAXO telescopes.

47 OTHER INSTRUMENTATION↗

femto-PIXAR: a self-supervised neural network method for reconstructing femtosecond X-ray free electron laser pulses

X-ray Free Electron Lasers (X-FELs) operate in a wide range of lasing configurations for a broad variety of scientific applications at ultrafast time-scales such as structural biology, materials science, and atomic and molecular physics. Shot-by-shot characterization of the X-FEL pulses is crucial for analysis of many experiments as well as tuning the X-FEL performance. However, for the weak pulses found in advanced configurations, e.g. those needed for coherent, two-pulse studies of quantum materials, there is no current method for reliably resolving pulse profiles. Here we show that a physics-based U-net model can reconstruct the individual pulse power profiles for sub-picosecond pulse separation without the need for simulations. Using experimental data from weak X-FEL pulse pairs, we demonstrate we can learn the pulse characteristics on a shot-by-shot basis when conventional methods fail.

43 PARTICLE ACCELERATORS↗

Laser-driven high-resolution MeV x-ray tomography

The need for high-resolution MeV x-ray tomography to observe the three-dimensional structure of dense, large-sized objects is rapidly increasing for the non-destructive evaluation of critical additively manufactured parts, national security, and other applications. We report a demonstration of high-resolution MeV computed tomography of a dense, large object with a laser-driven x-ray source. A record detector-limited MeV radiograph resolution of < 200 µm as determined with the Bennett approximation of the point spread function was achieved by irradiating millimeter-thick tungsten targets with 300 TW femtosecond laser pulses at a 0.5 Hz repetition rate. A tungsten alloy step wedge spectrometer indicates that the peak of the x-ray emission is between 1 and 2 MeV, with an endpoint energy of 19 MeV. To illustrate the radiographic imaging capability of the system, a tomographic reconstruction of a nickel superalloy turbine blade ( maximum $ρr$ = 139 g/cm 2 ) with sub-millimeter resolution was performed using 2160 individual radiographs. The small x-ray source size opens the prospect of extremely high-resolution tomographs of large, dense objects. This laser-driven approach has major advantages for non-destructive evaluation.

47 OTHER INSTRUMENTATION↗