Search NASA⌕ Search

SEARCH · Search NASA

Results for “ZONES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Integrated Strategy to Address Hanford’s Deep Vadose Zone Remediation Challenges

A vast majority of Hanford’s remaining in-ground contaminants reside in the vadose zone of the Central Plateau, where reprocessing operations occurred. The vadose zone is comprised of about 75 meters of water-unsaturated sediments above groundwater. These contaminants have, and continue to release into groundwater that discharges to the Columbia River. If left untreated, these contaminants could remain a threat for centuries. Much of this contamination resides deep in the vadose zone, below the effective depth of tradition surface remedy influence. In 2008, the Department of Energy initiated deep vadose zone treatability testing to seek remedies for technetium-99 and uranium contamination. These tests include the application of desiccation for technetium-99 and reactive gas technologies for uranium. To complement these efforts, the Department of Energy has initiated a “defense-in-depth” approach to address the unique challenges for characterization and remediation of the deep vadose zone. This defense-in-depth approach will implement multiple approaches to understand and control contaminant flux from the deep vadose zone to the groundwater. Among these approaches is an increased investment in science and technology solutions to resolve deep vadose zone challenges including characterization, prediction, remediation, and monitoring.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Zoned electrical heater arranged in spaced relationship from particulate filter

A system comprises a particulate matter (PM) filter that comprises an upstream end for receiving exhaust gas and a downstream end. A zoned heater is arranged spaced from the upstream end and comprises N zones, where N is an integer greater than one, wherein each of the N zones comprises M sub-zones, where M is an integer greater than one. A control module selectively activates at least a selected one of the N zones to initiate regeneration in downstream portions of the PM filter from the one of the N zones and deactivates non-selected ones of the N zones.

42 ENGINEERING↗

Geologic Assessment of the Damage Zone from the Second Test at Source Physics Experiment-Nevada (SPE-N)

The National Center for Nuclear Security (NCNS), established by the U.S. Department of Energy, National Nuclear Security Administration, is conducting a series of explosive tests at the Nevada National Security Site (NNSS; formerly the Nevada Test Site) that are designed to increase the understanding of certain basic physical phenomena associated with underground explosions. These tests will aid in developing technologies that might be used to detect underground nuclear explosions in support of verification activities for the Comprehensive Nuclear-Test-Ban Treaty (CTBT). The initial NCNS project is a series of explosive tests, known collectively as the Source Physics Experiment at the NNSS (SPE-N), being conducted in granitic rocks at the Climax stock in northern Yucca Flat. The SPE-N test series is designed to study the generation and propagation of seismic waves. The data will be used to improve the predictive capability of calculational models for detecting and characterizing underground explosions. The first SPE-N test (SPE-N-1) was a “calibration” shot conducted in May 2011, using 100 kilograms (kg) of explosives at the depth of 54.9 meters (m) (180 feet [ft]) in the U-15n source hole. SPE-N-2 was conducted in October 2011, using 1,000 kg of explosives at the depth of 45.7 m (150 ft) in the same source hole. Following the SPE-N-2 test, the core hole U-15n#10 was drilled at an angle from the surface to intercept the SPE-N-2 shot point location to obtain information necessary to characterize the damage zone. The desire was to determine the position of the damage zone near the shot point, at least on the northeast side, where the core hole penetrated it. The three-dimensional shape and symmetry of the damage zone are unknown at this time. Rather than spherical in shape, the dimensions of the damage zone could be influenced by the natural fracture sets in the vicinity. Geologic characterization of the borehole included geophysical logging, a directional survey, and geologic description of the core to document visual evidence of damage. Selected core samples were provided to Sandia National Laboratories (SNL) for laboratory tests (to be reported by SNL). A significant natural fault zone was encountered in the U-15n#10 angle core hole between the drilled depths of 149 and 155 ft (straight-line distance or range station [RS] from the shot point of 7.5 to 5.7 m). However, several of the fractures observed in the U-15n#10 hole are interpreted as having been caused by the explosion. These fractures are characterized by a “fresh,” mechanically broken look, with uncoated and very irregular surfaces. They tend to terminate against natural fractures and have orientations that differ from the previously defined natural fracture sets. The most distant fracture from the shot point that could be interpreted as having been caused by the explosion was seen at approximately RS 10.0 m. No other possibly explosion-induced fractures are apparent above the fault, but are common starting at RS 5.4 m, which is below the fault. It is unknown how the fault zone might have affected the propagation of seismic waves or how the materials in the fault zone (altered granite, breccia, gouge) were affected by the explosion. From RS 3.3 m to the end of the recovered core at RS 1.6 m, some of the core samples are softer and lighter in color, but do not appear to be weathered. It is thought this could be indicative of the presence of distributed microfracturing.

58 GEOSCIENCES↗

Technical and Policy Challenges in Deep Vadose Zone Remediation of Metals and Radionuclides - 12025

Deep vadose zone contamination is a significant issue facing the U.S. Department of Energy's (DOE) Office of Environmental Management (EM). Contamination in the deep vadose zone is isolated from exposure such that direct contact is not a factor in risk to human health and the environment. Transport of deep vadose zone contamination and discharge to the groundwater creates the potential for exposure and risk to receptors, so limiting flux to groundwater is key for protection of groundwater resources. Remediation approaches for the deep vadose zone need to be considered within the regulatory context, targeted at mitigating the source of contamination and reducing contaminant flux to groundwater. Processes for deep vadose zone metal and radionuclide remediation are discussed, as well as challenges and opportunities for implementation. It may be useful to consider the risk and challenges with leaving contaminants in place as part of a flux-control remedy in comparison with risks associated with contaminant removal and final disposition elsewhere. Understanding and quantifying the ramifications of contaminant removal and disposition options are therefore warranted. While this review suggests that some additional development work is needed for deep vadose zone remediation techniques, the benefits of applying vadose zone remediation for groundwater protection are compelling and worthy of continued development. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Addressing Technical and Policy Challenges for Remediation of Metals and Radionuclides within Complex Deep Vadose Zone Environments - 17028

Deep vadose zone contamination is a significant issue in many regions of the world. Although remediation of deep vadose zone contamination is important, direct contact with the contamination does not threaten human health or the environment due to its depth in the vadose zone. Yet, movement of contamination from the deep vadose zone to the groundwater creates the potential for exposure and risk to receptors. Therefore, the challenge of deep vadose zone remediation is to maintain a minimal rate of contaminant transport such that flux from the contaminated vadose zone is limited to protect groundwater resources and down-gradient receptors. We herein review major processes for viable remediation of deep vadose zone metal and radionuclides that form the practical constraints on remedial actions and provide an overview of how these principles are being practiced to address key contaminants at the U.S. Department of Energy Hanford Site. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

High-Resolution Characterization of Comingled Contaminants in the Deep Vadose Zone, Hanford Site, Washington - 17387

The contaminated deep vadose zone in the Central Plateau of the Hanford Site in Washington state presents a unique challenge to remediation. The Comprehensive Environmental Response, Compensation, and Liability Act, commonly known as the CERCLA project responsible for addressing these deep contaminants is designated as the 200-Deep Vadose Zone Operable Unit (DV-1 project). The vadose zone is 55-82 meters (180-270 feet) thick and is contaminated with both radiological and chemical contaminants from multiple historical waste streams. The mobile contaminants from this waste are still present in the deep vadose zone and pose a potential threat to the groundwater. Characterizing the nature and extent of the comingled mobile contaminants is an important step before assessing possible remedial alternatives. One factor controlling the migration and distribution of subsurface contaminants is the lithologic heterogeneity of the vadose zone sediments. A sampling plan for the DV-1 project includes continuous sediment core collection and analysis to identify key lithologic factors (i.e., small-scale bedding and structural features) that act as barriers, preferential pathways or conduits for mobile contaminants migrating through the vadose zone. Over six hundred meters (2,000 feet) of intact sediment core from 26 boreholes were collected in 1.5 meters (5 feet) long, 10 centimeter (4-inch) diameter segments. These intact sediment samples provide significant improvement in the level of detail and understanding of mechanisms and features controlling contaminant distribution that is not possible with traditional homogenized drill cuttings or conventional split-spoon samples. Detailed geological descriptions and photographs of the intact core are correlated to high-resolution geophysical logs which aid in the development of a comprehensive contaminant distribution profile of the borehole. These lithologic interpretations are used to define specific depth intervals for sampling based on changes in moisture, lithology, and elevated gamma radiation. The selected samples are analyzed for contaminants of concern, geochemical parameters, and hydraulic properties. Significant lithologic features observed in the intact cores include sharp contact boundaries to graded bedding, iron-oxide and carbonate cementation, silty laminations, clastic dike intrusions, and soft sediment deformation. Preliminary geologic logs integrated with the sample analysis indicate features that correlate to the variable distribution of contaminants both laterally and vertically. Integration of measured hydraulic parameters to lithologic units in individual borehole profiles provide key inputs for more precise geo-framework and vadose zone flux models supporting the DV-1 project. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Vadose zone monitoring at the radioactive waste management sites at the Nevada national security site - 15294

Two lysimeter facilities continuously monitor the vadose zone at the radioactive waste disposal sites at the Nevada National Security Site. The time-series data collected at these facilities support the performance assessments of the radioactive waste disposal sites, the closure cover designs, and the long-term monitoring decisions for these sites. The Weighing Lysimeter Facility at the Area 5 Radioactive Waste Management Site (RWMS) consists of a bare-soil weighing lysimeter and a vegetated weighing lysimeter. The upper surfaces of both weighing lysimeters are exposed to precipitation. The Drainage Lysimeter Facility at the Area 3 RWMS includes bare-soil lysimeters that receive precipitation or precipitation supplemented with irrigation equal to double precipitation and vegetated lysimeters that have the same upper boundary conditions as the bare-soil lysimeters. Lysimeter sensors are connected to data-loggers that are accessed remotely for data acquisition. Lysimeter water balance measurements show the arid climate and native vegetation at the NNSS provide a natural sustainable system to effectively prevent transport of contaminants from the RWMSs through the vadose zone to groundwater. Transport by infiltration and percolation of present day precipitation at the RWMSs is prevented. The native desert vegetation is adapted to extract moisture from very dry soils and maintains negative matric potentials at the base of the root zone effectively buffering the deep vadose zone from episodic precipitation events at the surface. The very negative matric potential at the base of the root zone effectively intercepts all infiltration from precipitation and draws moisture upward from the vadose zone below the root zone. This system is sustainable because it does not rely on engineered features and mimics the stable landscapes and no groundwater recharge of the current condition surrounding the RWMSs. The system depends on establishing native vegetation in the covers above the waste cells and a stable climate. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Transient Unsaturated Zone Modeling of Radioactive Waste Pits at Los Alamos National Laboratory - 87544 - 18432

Waste disposals at Material Disposal Area G (MDA G) at Los Alamos National Laboratory (LANL) occur primarily in a series of long, rectangular pits into which layers of waste have been emplaced beginning in the late 1950's. MDA G is situated in north-central New Mexico on top of Mesita del Buey, a narrow 3 km long mesa in the Parajito Plateau. The mesa is composed primarily of volcanic tuff from two principle volcanic eruptions in the Jemez Mountains which deposited the Otowi and Tshirege Members of the Bandelier Tuff. The Cerros del Rio Basalt underlay the tuff units and extends down for approximately 200 meters. The water table lies within the basalts at around 300 m below the surface of the mesa. The local climate is temperate and semiarid, averaging around 34 cm of precipitation per year. Ambient subsurface moisture conditions are dry, with water content typically below 10%. During disposal operations, open pits are subject to enhanced infiltration compared to the final covered configuration due to the unvegetated disturbed surface and precipitation events. Additionally, water added to the pits during disposal operations for tasks like waste compaction and dust suppression introduces additional moisture to the system during disposal operations that could potentially provide a pathway for contaminants in the waste zone to migrate through the unsaturated zone. Modeling was conducted using the HYDRUS-2D/3D software to evaluate the spatial extent of saturation changes and fluxes across geologic layer interfaces in the unsaturated zone throughout the life cycle of a waste pit. A general 2-dimensional framework was developed that included a cross section of a waste pit and the underlying geologic units. Several geological layerings were developed to represent the variation across the mesa at Area G. The model was run stochastically for hundreds of realizations to understand how variations in hydraulic parameters (e.g., porosity, saturated hydraulic conductivity, Van Genuchten parameters, etc.) and operational parameters (e.g., pit open period duration, pit depth, initial saturation of the waste zone, etc.) affect the extent of saturation changes and fluxes in the deep unsaturated zone. Distributions for these parameters were developed based on available site data. Results of the unsaturated zone modeling indicate that a significant amount of water can reach the lower unsaturated zone under some circumstances, particularly when the amount of water introduced during pit operations is high. A statistical study of modeling results was performed to develop a regression that describes the variations of water flux in time at the geological layer interfaces. These statistical model results will be used to evaluate solute transport in a future effort. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Deep Vadose Zone-Applied Field Research Initiative Fiscal Year 2011 Annual Report

This annual report describes the background of the Deep Vadose Zone-Applied Field Research Initiative, and some of the programmatic approaches and transformational technologies in groundwater and deep vadose zone remediation developed during fiscal year 2011. The Department of Energy (DOE) Office of Technology Innovation and Development's (OTID) mission is to transform science into viable solutions for environmental cleanup. In 2010, OTID developed the Impact Plan, Science and Technology to Reduce the Life Cycle Cost of Closure to outline the benefits of research and development of the lifecycle cost of cleanup across the DOE complex. This plan outlines OTID's ability to reduce by $50 billion, the $200 billion life-cycle cost in waste processing, groundwater and soil, nuclear materials, and deactivation and decommissioning. The projected life-cycle costs and return on investment are based on actual savings realized from technology innovation, development, and insertion into remedial strategies and schedules at the Fernald, Mound, and Ashtabula sites. To achieve our goals, OTID developed Applied Field Research Initiatives to facilitate and accelerate collaborative development and implementation of new tools and approaches that reduce risk, cost and time for site closure. The primary mission of the Deep Vadose Zone-Applied Field Research Initiative (DVZ-AFRI) is to protect our nation's water resources, keeping them clean and safe for future generations. The DVZ-AFRI was established for the DOE to develop effective, science-based solutions for remediating, characterizing, monitoring, and predicting the behavior and fate of deep vadose zone contamination. Subsurface contaminants include radionuclides, metals, organics, and liquid waste that originated from various sources, including legacy waste from the nation's nuclear weapons complexes. The DVZ-AFRI project team is translating strategy into action by working to solve these complex challenges in a collaborative environment that leverages technology and scientific expertise from DOE, Pacific Northwest National Laboratory, CH2M HILL Plateau Remediation Company, and the broad scientific research community. As project manager for the DVZ-AFRI, I have had the privilege this past year to team with creative, talented members of the scientific community nationwide to develop effective long-term solutions to address deep vadose zone contamination. This report highlights how the DVZ-AFRI project team is delivering results by achieving significant programmatic accomplishments, and developing and field-testing transformational technologies to address the nation's most pressing groundwater and vadose zone contamination problems.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Statistic inversion of multi-zone transition probability models for aquifer characterization in alluvial fans

Understanding the heterogeneity arising from the complex architecture of sedimentary sequences in alluvial fans is challenging. This study develops a statistical inverse framework in a multi-zone transition probability approach for characterizing the heterogeneity in alluvial fans. An analytical solution of the transition probability matrix is used to define the statistical relationships among different hydrofacies and their mean lengths, integral scales, and volumetric proportions. A statistical inversion is conducted to identify the multi-zone transition probability models and estimate the optimal statistical parameters using the modified Gauss–Newton–Levenberg–Marquardt method. The Jacobian matrix is computed by the sensitivity equation method, which results in an accurate inverse solution with quantification of parameter uncertainty. We use the Chaobai River alluvial fan in the Beijing Plain, China, as an example for elucidating the methodology of alluvial fan characterization. The alluvial fan is divided into three sediment zones. In each zone, the explicit mathematical formulations of the transition probability models are constructed with optimized different integral scales and volumetric proportions. The hydrofacies distributions in the three zones are simulated sequentially by the multi-zone transition probability-based indicator simulations. Finally, the result of this study provides the heterogeneous structure of the alluvial fan for further study of flow and transport simulations.

54 ENVIRONMENTAL SCIENCES↗

Pervasive low-velocity layer atop the 410-km discontinuity beneath the northwest Pacific subduction zone: Implications for rheology and geodynamics

Regional triplication waveforms of five intermediate-depth events are modeled to simultaneously obtain the compressional (P) and shear (SH) wave velocity structure beneath northwestern Pacific subduction zone. Both the P- and SH-wave velocity models for three different sub-regions show a low-velocity layer (LVL) with a thickness of ~55-80 km lying above the 410-km discontinuity with a ~900 km lateral extent from the Japan Sea to the northeastern Asian continental margin. With the dihedral angle approaching to zero around 400 km, a minute amount of melt atop the 410-km discontinuity caused by the hydrous slab might completely wet olivine grain boundaries and result in a low seismic velocity layer in this specific subduction zone. This mechanism suggests that the 410-LVL is a low viscosity zone that would partially decouple the upper mantle from the transition zone. We infer that the widespread 410-LVL provides evidence for a water-bearing mantle transition zone beneath the western Pacific subduction zone.

58 GEOSCIENCES↗

A Revised Look at Relativistic Electrons in the Earth's Inner Radiation Zone and Slot Region

We describe a new, more accurate procedure for estimating and removing inner zone background contamination from Van Allen Probes Magnetic Electron Ion Spectrometer (MagEIS) radiation belt measurements. This new procedure is based on the underlying assumption that the primary source of background contamination in the electron measurements at L shells less than three, energetic inner belt protons, is relatively stable. Since a magnetic spectrometer can readily distinguish between foreground electrons and background signals, we are able to exploit the proton stability to construct a model of the background contamination in each MagEIS detector by only considering times when the measurements are known to be background dominated. We demonstrate, for relativistic electron measurements in the inner zone, that the new technique is a significant improvement upon the routine background corrections that are used in the standard MagEIS data processing, which can “overcorrect” and therefore remove real (but small) electron fluxes. As an example, we show that the previously reported 1-MeV injection into the inner zone that occurred in June of 2015 was distributed more broadly in L and persisted in the inner zone longer than suggested by previous estimates. Such differences can have important implications for both scientific studies and spacecraft engineering applications that make use of MagEIS electron data in the inner zone at relativistic energies. We compare these new results with prior work and present more recent observations that also show a 1-MeV electron injection into the inner zone following the September 2017 interplanetary shock passage.

79 ASTRONOMY AND ASTROPHYSICS↗

Modeling Zone-3 Protection with Generic Relay Models for Dynamic Contingency Analysis

This paper presents a cohesive approach for calculating and coordinating the settings of multiple zone-3 protections for dynamic contingency analysis. The zone-3 protections are represented by generic distance relay models. A two-step approach for determining zone-3 relay settings is proposed. The first step is to calculate settings, particularly, the reach, of each zone-3 relay individually by iteratively running line open-end fault short circuit analysis; the blinder is also employed and properly set to meet the industry standard under extreme loading conditions. The second step is to systematically coordinate the protection settings of the zone-3 relays. The main objective of this coordination step is to address the over-reaching issues. We have developed a tool to automate the proposed approach and generate the settings of all distance relays in a PSS/E dyr format file. The calculated zone-3 settings have been tested on a modified IEEE 300 system using a dynamic contingency analysis tool (DCAT).

computational modeling↗

Effect of Rapidly Changing River Stage on Uranium Flux through the Hyporheic Zone

At the Hanford Site, the flux of uranium contaminated groundwater into the Columbia River varies according to the dynamic changes in hydraulic gradient caused by fluctuating river stage. The river stage changes in response to operations of dams on the Columbia River. Piezometers were installed in the hyporheic zone to facilitate long term, high frequency measurement of water and uranium fluxes into the Columbia River in response to fluctuating river stage. In addition, measurement of the water level in the near shore unconfined aquifer enhanced the understanding of the relationship between fluctuating river stage and uranium flux. The changing river stage caused head fluctuations in the unconfined aquifer, and resulted in fluctuating hydraulic gradient in the hyporheic zone. Further, influx of river water into the unconfined aquifer caused reduced uranium concentration in near shore groundwater as a result of dilution. Calculated water flux through the hyporheic zone ranged between 0.3 and -0.5 L/min/m2. The flux of uranium through the hyporheic zone exceeded 30 ug/min/m2 during some time periods, but was generally on the order of 3 to 5 ug/min/m2 over the course of this study. It was also found that at this location, the top 20 cm of the hyporheic zone constituted the most restrictive portion of the aquifer, and controlled the flux of water through the hyporheic zone.

13 HYDRO ENERGY↗

Estimating Persistent Mass Flux of Volatile Contaminants from the Vadose Zone to Ground Water

Contaminants may persist for long time periods within low permeability portions of the vadose zone where they cannot be effectively treated and are a potential continuing source of contamination to groundwater. Setting appropriate vadose zone remediation goals requires evaluating these persistent sources in terms of their impact on meeting groundwater remediation goals. One-dimensional approaches for estimating transport of volatile contaminants in the vadose zone are considered and compared to a one-dimensional flux-continuity-based assessment of vapor-phase contaminant movement from the vadose zone to the groundwater. The flux-continuity-based assessment demonstrates that the ability of the groundwater to move contaminant away from the water table controls the vapor-phase mass flux from the vadose zone across the water table. Limitations of the one-dimensional approaches are then discussed with respect to the need for further method development and application of two- or three-dimensional numerical modeling. The carbon tetrachloride (CT) plume at the U.S. Department of Energy Hanford Site is used as an example of a site where persistent vadose zone contamination needs to be considered in the context of groundwater remediation.

54 ENVIRONMENTAL SCIENCES↗

Advanced Remedial Methods for Metals and Radionuclides in Vadose Zone Environments

Functionally, the methods for addressing contamination must remove and/or reduce transport or toxicity of contaminants. This problem is particularly challenging in arid environments where the vadose zone can be up to hundreds of feet thick, rendering transitional excavation methods exceedingly costly and ineffective. Delivery of remedial amendments is one of the most challenging and critical aspects for all remedy-based approaches. The conventional approach for delivery is through injection of aqueous remedial solutions. However, heterogeneous vadose zone environments present hydrologic and geochemical challenges that limit the effectiveness. Because the flow of solution infiltration is dominantly controlled by gravity and suction, injected liquid preferentially percolates through highly permeable pathways, by-passing low-permeability zones which frequently contain the majority of the contamination. Moreover, the wetting front can readily mobilize and enhance contaminant transport to underlying aquifers prior to stabilization. Development of innovative, in-situ technologies may be the only way to meet remedial action objectives and long-term stewardship goals. Shear-thinning fluids (i.e., surfactants) can be used to lower the liquid surface tension and create stabile foams, which readily penetrate low permeability zones. Although surfactant foams have been utilized for subsurface mobilization efforts in the oil and gas industry, so far, the concept of using foams as a delivery mechanism for transporting reactive remedial amendments into deep vadose zone environments to stabilize metal and long-lived radionuclide contaminants has not been explored. Foam flow can be directed by pressure gradients, rather than being dominated by gravity; and, foam delivery mechanisms limit the volume of water (< 20% vol.) required for remedy delivery and emplacement, thus mitigating contaminant mobilization. We will present the results of a numerical modeling and integrated laboratory-/ intermediate-scale investigation to simulate, develop, demonstrate, and monitor (i.e. advanced geophysical techniques and advanced predictive biomarkers) foam-based delivery of remedial amendments to remediate metals and radionuclides in vadose zone environments.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hanford Site Vadose-Zone Studies: An Overview

Large quantities of radioactive and chemical wastes, created from plutonium production for nuclear weapons, are located in a remote desert setting at the U. S. Department of Energy’s Hanford Site, north of Richland, Washington, USA. Much of the waste currently resides in the vadose zone. At Hanford, the vadose zone is characterized by glacial-fluvial sediments that are often highly stratified. The extremely heterogeneous sediments give rise to complex subsurface-flow paths that contribute to uncertainty of contaminant fate and transport. Research efforts have focused on answering questions of contaminant transport from the viewpoint of geologic, biologic, geochemical and hydrologic controls. This special section of the Vadose Zone Journal highlights key research topics that are systematically addressing vadose zone problems at the Hanford Site. Research to date indicates that some of the contaminant species (e.g., Cs-137, Co-60, Sr-90, uranium, etc.) are highly reactive with Hanford sediments, as predicted by geochemical considerations, rendering them effectively immobile, except under extremely saline or acidic conditions, while other species (e.g., Tc-99, I-129, H-3) are typically mobile and have moved deep into the vadose zone and subsequently into groundwater. In addition, large quantities of organics, including carbon tetrachloride, have moved in complex ways as both vapor and liquid, and have reached the water table at some locations where they represent a potential long-term threat to groundwater. Observed transport of mobile species is linked to liquid discharges and to elevated recharge rates that occur primarily at waste sites where land surfaces are void of vegetation and where winter rains have subsequently penetrated the subsurface wastes. A series of papers in this special issue document progress to date in understanding transport rates at Hanford, why anisotropy strongly affects the distribution of subsurface contaminants, why organic contaminants such as DNAPLs (e.g., carbon tetrachloride) are so difficult to find in the deep vadose zone, and what are the impacts of hypersaline fluids on waste form degradation and subsequent transport.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of Soil Flushing for Application to the Deep Vadose Zone in the Hanford Central Plateau

Soil flushing was included in the Deep Vadose Zone Treatability Test Plan for the Hanford Central Plateau as a technology with the potential to remove contaminants from the vadose zone. Soil flushing operates through the addition of water, and if necessary an appropriate mobilizing agent, to mobilize contaminants and flush them from the vadose zone and into the groundwater where they are subsequently captured by a pump-and-treat system. There are uncertainties associated with applying soil flushing technology to contaminants in the deep vadose zone at the Hanford Central Plateau. The modeling and laboratory efforts reported herein are intended to provide a quantitative assessment of factors that impact water infiltration and contaminant flushing through the vadose zone and into the underlying groundwater. Once in the groundwater, capture of the contaminants would be necessary, but this aspect of implementing soil flushing was not evaluated in this effort. Soil flushing was evaluated primarily with respect to applications for technetium and uranium contaminants in the deep vadose zone of the Hanford Central Plateau.

54 ENVIRONMENTAL SCIENCES↗