Search NASA⌕ Search

SEARCH · Search NASA

Results for “aberration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

A note on the location of the stagnation point in the magnetosheath flow

While observational and theoretical investigations have clearly indicated that the shape of the magnetosphere is very nearly symmetric about the plane determined by the aberrated solar wind flow direction and the earth's magnetic dipole, many processes such as magnetic pulsations and geomagnetic activity which should be shape dependent do not exhibit symmetry about this plane. The present paper proposes a solution to this apparent paradox in terms of the shifting of the stagnation point in the magnetosheath flow. It is shown that the interplanetary magnetic field can act to shift the stagnation point on the order of 15 deg from the nose towards dawn during periods of low Alfven Mach number without an appreciable aberration of the magnetopause, accounting for the observations of pulsation demarcation and magnetic reconnection.

Russell, C. T.↗

Development of a tantalum pentoxide Luneberg lens

A process has been developed for the fabrication of a tantalum pentoxide waveguide Luneburg lens as the input collimator for an optical signal processing circuit on a silicon substrate, such as an integrated wavelength demultiplexer. The development of such a lens involved improvement of the deposition mask profile, reduction of surface scattering by underlaying the lens, reduction of edge scattering by using shims under the mask, and prediction and measurement of the TE-TM polarization aberration. It is shown that polarization aberration significantly affects the design of a demultiplexer system.

Bryan, D. A.↗

Variable line-space gratings - New designs for use in grazing incidence spectrometers

An account is given of a fundamentally different approach to the use of variable line-space gratings for grazing incidence spectrometers. In the new approach, the gratings are flat and they are placed to intercept the converging beam from a collecting mirror rather than the diverging beam from a slit. This results in (1) small aberrations over a wide instantaneous range in wavelength, (2) a modest required variation in line spacing across the ruled width, (3) a simultaneous minimization of both the spectral and image height aberrations, and (4) a completely stigmatic zero order image. The slitless arrangement common to these designs is very compact, having no additional length behind the focal plane of the collecting mirror. In-plane and conical fan designs are considered. One combination design, in the form of an echelle spectrometer, is discussed. The designs are considered to represent ideal candidates for moderate to high resolution spectrometers on such missions as the Far Ultraviolet Spectroscopic Explorer (FUSE, now Columbus) and the Advanced X-ray Astrophysics Facility (AXAF).

Hettrick, M. C.↗

Designing Eccentric Aperture Optical Systems

Computer program aids in design of eccentric aperture optical systems by predicting vector aberration that occurs in optical system having tilted or decentered optical elements. Computer program incorporates vector theory of aberrations.

Rogers, J. R.↗

Four spot laser anemometer and optical access techniques for turbine applications

A time-of-flight anemometer (TOFA) system, utilizing a spatial lead-lag filter for bipolar pulse generation was constructed and tested. This system, called a Four Spot Laser Anemometer, was specifically designed for use in high speed, turbulent flows in the presence of walls or surfaces. The TOFA system uses elliptical spots to increase the flow acceptance angle to be comparable with that of a fringe type anemometer. The tightly focused spots used in the Four Spot yield excellent flare light rejection capabilities. Good results were obtained to 75 microns normal to a surface, with a f/2.5 collecting lens. This system is being evaluated for use in a warm turbine facility. Results from both a particle lag velocity experiment and boundary layer profiles will be discussed. In addition, an analysis of the use of curved windows in a turbine casing will be presented. Curved windows, matching the inner radius of the turbine casing, preserve the flow conditions, but introduce astigmatic aberrations. A correction optic was designed that virtually eliminates these astigmatic aberrations throughout the intrablade survey region for normal incidence.

Wernet, Mark P.↗

Low voltage scanning electron microscopy of interplanetary dust particles

The resolution of available low-voltage SEM (LVSEM) models used in the characterization of interplanetary dust particles (IDPs) is limited by a number of factors including energy spread in the electron source, beam brightness, scanning electron detector geometry, and various lens aberrations. This paper describes an improved model of LVSEM which offers an increased resolution at low voltage. The improvements include a cold cathode FE source which has an extremely low inherent energy spread and high brightness, a second condenser lens to converge the beam and maintain an optimum aperture half-angle, and a detector optimized for low-voltage scanning-electron collection. To reduce lens aberrations, the specimen is immersed in the objective lens field. The features of several IDP samples observed using the images obtained with this LVSEM model are described.

Blake, D. F.↗

Four spot laser anemometer and optical access techniques for turbine applications

A time-of-flight anemometer (TOFA) system utilizing a spatial lead-lag filter for bipolar pulse generation has been constructed and tested. This system, called a four-spot laser anemometer, was specifically designed for use in high-speed, turbulent flows in the presence of walls or surfaces. The TOFA system uses elliptical spots to increase the flow acceptance angle to be comparable with that of a fringe-type anemometer. The tightly focused spots used in the four spot yield excellent flare light rejection capabilities. Good results have been obtained to 75 microns normal to a surface, with an f/2.5 collection lens. This system is being evaluated for use in a warm turbine facility. Results from both a particle-lag velocity experiment and boundary layer profiles will be discussed. In addition, an analysis of the use of curved windows in a turbine casing will be presented. Curved windows, matching the inner radius of the turbine casing, preserve the flow conditions, but introduce astigmatic aberrations. A correction optic was designed that virtually eliminates these astigmatic aberrations throughout the intrablade survey region for normal incidence.

Wernet, Mark P.↗

Integrated Grating Spectrometer

Proposed integrated grating spectrometer made in waveguide layer on silicon wafer. Occupies area of about 2 centimeters to 2nd power on wafer 0.4 mm thick. Operates in visible spectrum (wavelengths of 400 to 700 nm) and blazed to diffract in first order. Array of integrated grating spectrometers performs spectral analysis of picture elements along line. Optical fiber couples light from each picture element into separate integrated spectrometer. Technique enables continous independent variation, along grating, of pitch, curvature, and blaze angle. Grating designed to have large numerical aperture, zero aberration at two selected wavelengths, and very low aberration at intermediate wavelengths.

Lang, Robert J.↗

Deferred electronic heterodyne moire deflectometry: A method for transient density fields measurement

Effects of spherical aberrations of the mirror used in the moire system on the angular resolution of the system are investigated. It is shown that the spherical aberrations may reduce significantly the performance of the conventional moire deflectometer. However, due to the heterodyne procedure, this is not the case with the heterodyne moire system. A moire system with a constant speed moving grating is demonstrated. It is shown that the system readout is linear and the system does not need calibration. In addition, the repeatability of the measurements is improved in this system as compared to the sinusoidally moving grating setup. The problem of the photographic plates alignment is solved by using a mechanical system in which the plate is held firmly throughout the experiment and accurately replaced after removing for photographic processing. The effect of a circular detector's aperture size on readout was tested. It is shown that the spatial phase variations, observed when scanning along a straight moire fringe, may considerably be reduced. At present we may say that both the on-line and the deferred heterodyne moire techniques may reliably be used. The errors of phase readings are 1 deg and 5 deg for the on-line and deferred methods. The total error due to subtraction of two readings at each position is, therefore, 1.4 deg and 7 deg, respectively. Further research for improving the deferred system is suggested.

Stricker, Josef↗

Accuracy requirements of optical linear algebra processors in adaptive optics imaging systems

The accuracy requirements of optical processors in adaptive optics systems are determined by estimating the required accuracy in a general optical linear algebra processor (OLAP) that results in a smaller average residual aberration than that achieved with a conventional electronic digital processor with some specific computation speed. Special attention is given to an error analysis of a general OLAP with regard to the residual aberration that is created in an adaptive mirror system by the inaccuracies of the processor, and to the effect of computational speed of an electronic processor on the correction. Results are presented on the ability of an OLAP to compete with a digital processor in various situations.

Downie, John D.↗

Optomechanical design of the grating laser beam combiner (GLBC) laser diode header

A laser diode header has been fabricated for a grating laser beam combiner (GLBC). The laser diode header provides the thermal control, the drive electronics, and the optical system necessary for proper operation of the beam combiner. The diode header is required to provide diffraction limited optical performance while providing correction for worst case defocus aberration, 0.6 mrad excess divergence, and worst case decenter aberration, 1.0 mrad pointing error. The design of the header considered the mechanical design and the optical design together resulting in a small, self-contained header with 0.7 mrad range for focus correction and +/- 2.5 mrad of beam steering. The complete diode header is currently undergoing optical and mechanical performance testing.

Rall, Jonathan A. R.↗

Broadband, Achromatic Twyman-Green Interferometer

Improved Twyman-Green interferometer used in wave-front testing optical components at wavelengths from 200 to 1,100 nm, without having to readjust focus when changing wavelength. Built to measure aberrations of light passing through optical filters. Collimating and imaging lenses of classical Twyman-Green configuration replaced by single spherical mirror. Field lens replaced by field mirror. Mirrors exhibit no axial chromatic aberration and made to reflect light efficiently over desired broad range of wavelengths.

Steimle, Lawrence J.↗

X ray microscope assembly and alignment support and advanced x ray microscope design and analysis

Considerable efforts have been devoted recently to the design, analysis, fabrication, and testing of spherical Schwarzschild microscopes for soft x ray application in microscopy and projection lithography. The spherical Schwarzschild microscope consists of two concentric spherical mirrors configured such that the third order spherical aberration and coma are zero. Since multilayers are used on the mirror substrates for x ray applications, it is desirable to have only two reflecting surfaces in a microscope. In order to reduce microscope aberrations and increase the field of view, generalized mirror surface profiles have been considered in this investigation. Based on incoherent and sine wave modulation transfer function (MTF) calculations, the object plane resolution of a microscope has been analyzed as a function of the object height and numerical aperture (NA) of the primary for several spherical Schwarzschild, conic, and aspherical head reflecting two mirror microscope configurations.

Shealy, David L.↗

Hubble Space Telescope: SRM/QA observations and lessons learned

The Hubble Space Telescope (HST) Optical Systems Board of Investigation was established on July 2, 1990 to review, analyze, and evaluate the facts and circumstances regarding the manufacture, development, and testing of the HST Optical Telescope Assembly (OTA). Specifically, the board was tasked to ascertain what caused the spherical aberration and how it escaped notice until on-orbit operation. The error that caused the on-orbit spherical aberration in the primary mirror was traced to the assembly process of the Reflective Null Corrector, one of the three Null Correctors developed as special test equipment (STE) to measure and test the primary mirror. Therefore, the safety, reliability, maintainability, and quality assurance (SRM&QA) investigation covers the events and the overall product assurance environment during the manufacturing phase of the primary mirror and Null Correctors (from 1978 through 1981). The SRM&QA issues that were identified during the HST investigation are summarized. The crucial product assurance requirements (including nonconformance processing) for the HST are examined. The history of Quality Assurance (QA) practices at Perkin-Elmer (P-E) for the period under investigation are reviewed. The importance of the information management function is discussed relative to data retention/control issues. Metrology and other critical technical issues also are discussed. The SRM&QA lessons learned from the investigation are presented along with specific recommendations. Appendix A provides the MSFC SRM&QA report. Appendix B provides supplemental reference materials. Appendix C presents the findings of the independent optical consultants, Optical Research Associates (ORA). Appendix D provides further details of the fault-tree analysis portion of the investigation process.

Rodney, George A.↗

Inverting Image Data For Optical Testing And Alignment

Data from images produced by slightly incorrectly figured concave primary mirror in telescope processed into estimate of spherical aberration of mirror, by use of algorithm finding nonlinear least-squares best fit between actual images and synthetic images produced by multiparameter mathematical model of telescope optical system. Estimated spherical aberration, in turn, converted into estimate of deviation of reflector surface from nominal precise shape. Algorithm devised as part of effort to determine error in surface figure of primary mirror of Hubble space telescope, so corrective lens designed. Modified versions of algorithm also used to find optical errors in other components of telescope or of other optical systems, for purposes of testing, alignment, and/or correction.

Shao, Michael↗

Polarization analysis of a balloon-borne solar magnetograph

The main text of the report contains the particular results of our research which relate to the Experimental Vector Magnetograph (EXVM) and the Balloon-borne Vector Magnetograph (BVM). A brief overview of which elements in the EXVM and BVM that are relevant to this polarization analysis are presented. The possible meaning of the 10(exp -5) polarization specification for the BVM is discussed qualitatively. A recommendation of which polarization specification is most relevant for the BVM is provided. A diattenuation budget for the various surfaces in the BVM which will allow the polarization specification to be met is discussed. An explanation of the various coating specifications which are recommended is presented. Optical design of the EXVM and coating specification sheets for the BVM are presented. The appendices of this report contain the more general results of our research on the general topic of polarization aberrations. A general discussion of polarization aberration theory, in terms of the SAMEX solar magnetograph, and rigorous derivations for the Mueller matrices of optical systems are also presented in the appendices.

Reiley, Daniel J.↗

Imaging Spectrometers Using Concave Holographic Gratings

Imaging spectroscopy combines the spatial attributes of imaging with the compositionally diagnostic attributes of spectroscopy. For spacebased remote sensing applications, mass, size, power, data rate, and application constrain the scanning approach. For the first three approaches, substantial savings in mass and size of the spectrometer can be achieved in some cases with a concave holographic grating and careful placement of an order-sorting filter. A hologram etched on the single concave surface contains the equivalent of the collimating, dispersing, and camera optics of a conventional grating spectrometer and provides substantial wavelength dependent corrections for spherical aberrations and a flat focal field. These gratings can be blazed to improve efficiency when used over a small wavelength range or left unblazed for broadband uniform efficiency when used over a wavelength range of up to 2 orders. More than 1 order can be imaged along the dispersion axis by placing an appropriately designed step order-sorting filter in front of the one- or two-dimensional detector. This filter can be shaped for additional aberration corrections. The VIRIS imaging spectrometer based on the broadband design provides simultaneous imaging of the entrance slit from lambda = 0.9 to 2.6 microns (1.5 orders) onto a 128 x 128 HgCdTe detector (at 77 K). The VIRIS spectrometer was used for lunar mapping with the UH 24.in telescope at Mauna Kea Observatory. The design is adaptable for small, low mass, space based imaging spectrometers.

Gradie, J.↗

Temperature induced distortions in space telescope mirrors

In this paper, it is illustrated how measured instantaneous coefficients of thermal expansion (CTE) can be accurately taken into account when modeling the structural behavior of space based optical systems. In particular, the importance of including CTE spatial variations in the analysis of optical elements is emphasized. A comparison is made between the CTE's of three optical materials commonly used in the construction of space mirrors (ULE, Zerodur, and beryllium). The overall impact that selection of any one of these materials has on thermal distortions is briefly discussed. As an example of how temperature dependent spatial variations in thermal strain can be accurately incorporated in the thermo-structural analysis of a precision optical system, a finite element model is developed, which is used to estimate the thermally induced distortions in the Hubble Space Telescope's (HST) primary mirror. In addition to the structural analysis, the optical aberrations due to thermally induced distortions are also examined. These calculations indicate that thermal distortions in HST's primary mirror contribute mainly to defocus error with a relatively small contribution to spherical aberration.

Nied, H. F.↗