At least 253 records · Page 14

Polarization Losses under Accelerated Stress Test Using Multiwalled Carbon Nanotube Supported Pt Catalyst in PEM Fuel Cells

The electrochemical behavior for Pt catalysts supported on multiwalled carbon nanotubes and Vulcan XC-72 in proton exchange membrane fuel cells under accelerated stress test was examined by cyclic voltammetry, electrochemical impedance spectroscopy, and polarization technique. Pt catalyst supported on multiwalled carbon nanotubes exhibited highly stable electrochemical surface area, oxygen reduction kinetics, and fuel cell performance at a highly oxidizing condition, indicating multiwalled carbon nanotubes show high corrosion resistance and strong interaction with Pt nanoparticles. The Tafel slope, ohmic resistances, and limiting current density determined were used to differentiate kinetic, ohmic, mass-transfer polarization losses from the actual polarization curve. Kinetic contribution to the total overpotential was larger throughout the stress test. However, the fraction of kinetic overpotential decreased and mass-transfer overpotential portion remained quite constant during accelerated stress test, whereas the fraction of ohmic overpotential primarily originating from severe proton transport limitation in the catalyst layer increased under the anodic potential hold.

30 DIRECT ENERGY CONVERSION↗

Accelerated Stress Testing on Multichannel Drivers—Updated Test Results

This report is the second in a series of studies about accelerated stress testing (AST) of drivers used for SSL luminaires. Two-stage drivers intended for use in downlights, troffers and street lights were selected to undergo exposure to an AST environment consisting of 75°C and 75% relative humidity (7575). The 7575 AST environment was chosen for this study because a previous study demonstrated that 38% of a sample population of 6-inch downlights failed in less than 2,500 hours in these conditions. A mixture of single-channel (i.e., one output current channel designed for use with one LED primary) and multichannel (i.e., separate output current channels designed for use with multiple for LED primaries) two-stage drivers were exposed to the 7575 environment. This report provides updated AST test results for only the multichannel driver products. The multichannel driver population consisted of three products (with two-stage architecture) and a total of five samples. In addition to AST results, the product life distribution (Weibull analysis) of two-stage driver Hammer Test samples is reported.

42 ENGINEERING↗

Intrinsic Stability of Thin-Film CdS/CdTe Modules

Stability of thin-film CdTe module is crucial to the advancement of the technology. Long-term stability studies are carried out under a variety of accelerated test conditions. Accelerated-life-tests (ALT) are performed in the laboratory to accelerate degradation and hence quantify performance change in reasonably short periods of time. ALT studies attempt to simulate the conditions a solar module experiences outdoors during its lifetime, and ALT results are correlated to outdoor test results to estimate module service lifetimes, nameplate parameters, and product warranty. To accelerate degradation, laboratory experiments are often performed at elevated temperature, voltage bias and under continuous illumination. In this study laboratory size cells (0.5 cm{sup 2}), mini-modules (15 cm x 15 cm) and full-size encapsulated modules (60 cm x 120 cm) that consist of monolithically interconnected cells were subjected to different levels of illumination, elevated temperatures and electrical biases for extended periods of time. Changes in efficiency, fill-factor (FF), open-circuit voltage (Voc) and short-circuit current (Isc) as a function stress time and stress conditions are discussed.

14 SOLAR ENERGY↗

Motivation, benefits, and challenges for new photovoltaic material & module developments

Abstract In the last decade and longer, photovoltaic module manufacturers have experienced a rapidly growing market along with a dramatic decrease in module prices. Such cost pressures have resulted in a drive to develop and implement new module designs, which either increase performance and/or lifetime of the modules or decrease the cost to produce them. In this paper, the main motivations and benefits but also challenges for material innovations will be discussed. Many of these innovations include the use of new and novel materials in place of more conventional materials or designs. As a result, modules are being produced and sold without a long-term understanding about the performance and reliability of these new materials. This has led to unexpected new failure mechanisms occurring few years after deployment, such as potential induced degradation or backsheet cracking. None of these failure modes have been detected after the back then common single stress tests. New accelerated test approaches are based on a combination or sequence of multiple stressors that better reflect outdoor conditions. That allows for identification of new degradation modes linked to new module materials or module designs.

Oreski, G. (ORCID:0000000342239047)↗

Numerical modeling of a proof-of-principle experiment on optical stochastic cooling at an electron storage ring

Cooling of beams circulating in storage rings is critical for many applications including particle colliders and synchrotron light sources. A method enabling unprecedented beam-cooling rates, optical stochastic cooling (OSC), was recently demonstrated in the Integrable Optics Test Accelerator (IOTA) electron storage ring at Fermilab [J. Jarvis , ]. This paper describes the numerical implementation of the OSC process in the particle-tracking program and discusses the validation of the developed model with available experimental data. The model is also employed to highlight some features associated with different modes of operation of OSC. The developed simulation tool should be valuable in guiding future configurations of optical stochastic cooling and, more broadly, modeling self-field-based beam manipulations. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

High Pressure Hydrogen Pressure Relief Devices: Accelerated Life Testing and Application Best Practices

Pressure relief devices (PRDs ) are used to protect high pressure systems from burst failure caused by overpressurization. Codes and standards require the use of PRDs for the safe design of many pressurized systems. These systems require high reliability due to the risks associated with a burst failure. Hydrogen service can increase the risk of PRD failure due to material property degradation caused by hydrogen attack. The National Renewable Energy Laboratory (NREL) has conducted an accelerated life test on a conventional spring loaded PRD. Based on previous failures in the field, the nozzles specific to these PRDs are of particular interest. A nozzle in a PRD is a small part that directs the flow of fluid toward the sealing surface to maintain the open state of the valve once the spring force is overcome. The nozzle in this specific PRD is subjected to the full tensile force of the fluid pressure. These nozzles are made from 440C material, which is a type of hardened steel that is commonly chosen for high pressure applications because of its high strength properties. In a hydrogen environment, however, 440C is considered a worst case material since hydrogen attack results in a loss of almost all ductility and thus 440C is prone to fatigue and material failure. Accordingly, 440C is not recommended for hydrogen service. Conducting an accelerated life test on a PRD with 440C material provides information on necessary and sufficient conditions required to produce crack initiation and failure. The accelerated life test also provides information on other PRD failure modes that are somewhat statistically random in nature.

33 ADVANCED PROPULSION SYSTEMS↗

Improved Accelerated Stress Tests Based on Fuel Cell Vehicle Data

UTC will led a top-tier team of industry and national laboratory participants to update and improve DOE’s Accelerated Stress Tests (AST’s) for hydrogen fuel cells. This in-depth investigation will focused on critical fuel cell components (e.g. membrane electrode assemblies - MEA) whose durability represented barriers for widespread commercialization of hydrogen fuel cell technology. UTC had access to MEA materials that had accrued significant load time under real-world conditions in PureMotion® 120 power plant used in transit buses. These materials are referred to as end-of-life (EOL) components in the rest of this document. Advanced characterization techniques were used to evaluate degradation mode progress using these critical cell components extracted from both bus power plants and corresponding materials tested using the DOE AST’s. These techniques were applied to samples at beginning-of-life (BOL) to serve as a baseline. These comparisons advised the progress of the various failure modes that these critical components were subjected to, such as membrane degradation, catalyst support corrosion, platinum group metal dissolution, and others. Gaps in the existing ASTs predicted the degradation observed in the field in terms of these modes were outlined. Using the gaps, new AST’s were recommended and tested to better reflect the degradation modes seen in field operation. Also, BOL components were degraded in a test vehicle at UTC designed to accelerate the bus field operation.

08 HYDROGEN↗

Activation Energy Determination for Photovoltaic Encapsulant Discoloration by Indoor Accelerated UV Testing

A novel methodology for determining the activation energy of photovoltaic encapsulant discoloration using an indoor accelerated ultraviolet (UV) stress test while simultaneously maintaining multiple module temperatures in a single weathering chamber is presented. The testing was performed on some fresh mini-modules with a glass/EVA/cell/EVA/backsheet construction. The short-circuit current degradation from individual cells was used to quantify transmittance losses due to discoloration. Activation energy determined using indoor accelerated UV test data and Modified Arrhenius model ranges from 26 to 44 kJ/mol (0.27 to 0.46 eV). Activation energy was also determined from the outdoor field degradation data by employing different physical models that consider the individual or combined effects of key environmental factors. The approach here is instrumental to evaluating the reliability studies on encapsulant degradation mechanisms using relatively less time and resources.

14 SOLAR ENERGY↗

Long-term impact of light- and elevated temperature-induced degradation on photovoltaic arrays

Low levelized cost of electricity (LCOE) has been identified as critical for widespread adoption of photovoltaics (PV) without subsidies. Maintaining decades-long high-energy production is often an under-recognized opportunity in meeting cost goals because component lifetimes are not fully quantified at the time of manufacture. Whereas certain standardized tests minimize risk of early failure, there is little guidance to quantitatively predict degradation (or lack thereof) over decades, based on accelerated tests. In this article, we move toward bridging the understanding between indoor accelerated tests and outdoor performance data, with the goal of predicting energy yield with enough accuracy to inform financial decisions. Light- and elevated temperature-induced degradation (LETID) in p-type Si modules is analyzed in terms of impact on long-term module performance and thus LCOE. A method to predict the progression of LETID, using fixed kinetic constants and a numerical solution to the basic reaction rate equations, is detailed. Predictions are compared against both published data and that new to this study. These data include both indoor accelerated tests and fielded modules. We use the results in financial models to derive LCOE of modules in different climates with varying amounts of LETID, including uncertainty. Cost models based on the predictions indicate that LETID has a significant and climate-dependent impact on LCOE. Finally, we show that - even given the uncertainties identified in the study - these financial calculations can provide useful guidance to quantify risk based on accelerated test results. The analysis serves as an example of developing a predictive approach to PV reliability using physics of failure.

14 SOLAR ENERGY↗

Membrane Degradation Accelerated Stress Test

These are a set of slides that deal with membrane degradation accelerated stress test. Specifically, the following topics are covered: membrane degradation FCTT drive cycle; membrane ASTs; current membrane ASTs damage mechanisms; proposed membrane AST, RH cycling in H 2 /Air; current proposed AST; 2min/2min AST damage mechanism; 30sec/45sec RH cycling at OCV.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Field Work Proposal: PUBLIC OUTREACH EVENT FOR ACCELERATOR STEWARDSHIP TEST FACILITY PILOT PROGRAM

Jefferson Lab’s outreach efforts towards the goals of Accelerator Stewardship Test Facility Pilot Program consist of the lab’s efforts in three venues. The first venue, at the end of March is to meet with the members of Virginia Tech Corporate Research Center (VTCRC) (http://www.vtcrc.com/tenant-directory/) in Blacksburg, Virginia. Of the nearly 160 members, we expect that many engineering companies (including mechanical, electrical, bio, software) will be present. To this group, we will describe the capabilities of Jefferson Lab’s accelerator infrastructure. The description will include not only the facilities but also the intellectual expertise. No funding is requested for this effort. The second venue is to reach the industrial exhibitors at the 6th International Particle Accelerator Conference (IPAC’15). Jefferson Lab will host a booth at the conference to reach out to the >75 industrial exhibitors (https://www.jlab.org/conferences/ipac2015/SponsorsExhibitors.php) who represent a wide range of technologies. A number of these industries could benefit if they can access Jefferson Lab’s accelerator infrastructure. In addition to the booth, where written material will be available, we plan to arrange a session A/V presentation to the industry exhibitors. The booth will be hosted by Jefferson Lab’s Public Relations staff, assisted on a rotating basis by the lab’s scientists and engineers. The budget with IPAC’15 designations represents the request for funds for this effort. The third venue is the gathering of Southeastern Universities Research Association (SURA) university presidents. Here we plan to reach the research departments of the universities who can benefit by availing themselves to the infrastructure (material sciences, engineering, medical schools, material sciences, to name a few). Funding is requested to allow for attendance at the SURA Board Meeting. We are coordinating with DOE regarding these costs to raise the projected conference management cost ceiling in the Conference Management Tool.

99 GENERAL AND MISCELLANEOUS↗

Assessment of Accelerated Stress Testing Data for Silicon Photovoltaics Using Tensor Decomposition Methods

In this work, we examine the use of high-order tensor decompositions to analyze degradation pathways emerging from accelerated stress testing of silicon photovoltaic (PV) modules. Matrix-based decompositions are powerful tools for studying two-dimensional data arrays and form the foundation of a host of classical data analysis techniques. Tensors are high-order extrapolations of matrices that are able to account for more parameter dimensions, and a variety of tensor decomposition methods have been developed that similarly seek to extend insights from matrix decompositions to higher dimensions. Applying and interpreting tensor decomposition methods to sequences of PV module image data, we seek to uncover and isolate different degradation modes occurring from accelerated stress testing procedures. Further, we consider the contributions of different modes to PV module performance degradations.

data analysis↗

Towards validation of combined-accelerated stress testing through failure analysis of polyamide-based photovoltaic backsheets

Abstract Novel methods for advancing reliability testing of photovoltaic (PV) modules and materials have recently been developed. Combined-accelerated stress testing (C-AST) is one such method which has demonstrated reliable reproduction of some field-failures which were not reproducible by standard certification tests. To increase confidence and assist in the development of C-AST, and other new testing protocols, it is important to validate that the failure modes observed and mechanisms induced are representative of those observed in the field, and not the product of unrealistic stress conditions. Here we outline a method using appropriate materials characterization and modelling to validate the failure mechanisms induced in C-AST such that we can increase confidence in the test protocol. The method is demonstrated by applying it to a known cracking failure of a specific polyamide (PA)-based backsheet material. We found that the failure of the PA-based backsheet was a result of a combination of stress factors. Photo-oxidation from ultra-violet (UV) radiation exposure caused a reduction in fracture toughness, which ultimately lead to the cracking failure. We show that the chemical and structural changes observed in the backsheet following C-AST aging were also observed in field-aged samples. These results increase confidence that the conditions applied in C-AST are representative of the field and demonstrates our approach to validating the failure mechanisms induced.

14 SOLAR ENERGY↗

Concept, implementation and commissioning of the automation system for the accelerator module test facility AMTF

The European XFEL project launched on June 5, 2007 will require about 103 accelerator modules as a main part of the XFEL linear accelerator. All superconducting components constituting the accelerator module like cavities and magnets have to be tested before the assembly. For the tests of the individual cavities and the complete modules an XFEL Accelerator Module Test Facility (AMTF) has been erected at DESY. The process control system EPICS (Experimental Physics and Industrial Control System) is used to control and operate the cryogenic plant and all its subcomponents. A complementary component of EPICS is the Open Source software suit CSS (Control System Studio). CSS is an integrated engineering, maintenance and operating tool for EPICS. CSS enables local and remote operating and monitoring of the complete system and thus represents the human machine interface. More than 250 PROFIBUS nodes work at the accelerator module test facility. DESY installed an extensive diagnostic and condition monitoring system. With these diagnostic tools it is possible to examine the correct installation and configuration of all PROFIBUS nodes in real time. The condition monitoring system based on FDT/DTM technology shows the state of the PROFIBUS devices at a glance. This information can be used for preventive maintenance which is mandatory for continuous operation of the AMTF facility. The poster will describe all steps form engineering to implementation and commissioning.

43 PARTICLE ACCELERATORS↗

Dynamic Scaling Analysis of Accelerated Irradiation Testing on Additive Manufacturing Materials by Positron Annihilation

The timely applications of Additive Manufacturing (AM) materials in nuclear environments require accelerated irradiation tests, mainly ion irradiation to enable rapid prototyping. Low dose ion irradiation would cause sub-nanostructure changes by generation of lattice defects, vacancies, vacancy clusters and voids and void swelling caused by cellular dislocations. Positron Annihilation Lifetime (PAL), a novel technology, sensitive towards sub-nanostructure morphology with high accuracy (about 10-7 vacancy per atom), supported by Transition Electron Microscope (TEM) would be applied to identify the type and total size of the defects. The subsequent PAL measurements and TEM surface studies would be followed by PAL analysis that includes sophisticated trapping model. The PAS results would become an input to dynamic scaling analysis (that predicts radiation effects from low dose studies for high dose effects), which incorporate mean-field theory model. The final effect is an in-depth understanding of the microstructure evolution of AM materials under ion irradiation which can be extrapolated to the studies of neutron irradiation, since ion-irradiation takes less time and do not cause the irradiation hazard. The working hypothesis is that PAL technology, that have excellent sensitivity to low-defect concentration would help to identify ion-induced material damage on the atomic and nano-scale level, which then could be extrapolated to understand the neutron damage better.

accelerated irradiation testing↗

Accelerated Stress Testing of Fuel Cell Membranes Subjected to Combined Mechanical/Chemical Stressors and Cerium Migration

A highly accelerated stress test (HAST) has been developed to generate local stressful conditions that are representative of those in automotive fuel cell stacks. Using a 50-cm 2 cell cycled between 0.05 and 1.2 A/cm 2 with a low inlet RH in the co-flow configuration, the HAST creates a distribution of combined mechanical/chemical stressors in the membrane with the maximum chemical stress occurring near the gas inlets and the maximum mechanical stress near the outlets. Conducting HASTs using a current distribution measurement tool and a shorting/crossover diagnostic method to track the state of health of a robust membrane containing both a mechanical support and a chemical stabilizing additive, the result shows that the membrane location with the most severe thinning coincides with that of the deepest membrane hydration cycling. Upon examination of the cerium redistribution patterns after the test, it was found that the severe humidity cycling generated by the HAST condition near the outlet region not only generated the highest membrane mechanical stress but also resulted in the strongest water flux, which may cause local depletion of the cerium added as chemical stabilizer. Further study is required to decouple the cerium migration effect from the possible mechanical/chemical synergistic degradation effect.

25 ENERGY STORAGE↗

Accelerated Lifetime Testing of Main Shaft Seals for Tidal Turbine Rotors

This document will briefly discuss the observations and results from an NREL conducted accelerated lifetime testing of the main shaft seal for the Verdant Power fifth generation Gen5 underwater Tidal Energy Converter (TEC) turbine, which successfully performed at the RITE project in 2020-2021. In order to evaluate a 5-year Service Interval ( SI) for this component, testing at NREL operated the main shaft seal nearly continuously for over 135 (text says 130 days on page 5 and 125 days on page 7 and 137 days on page 11) days at a rotational velocity of 160 rpm while the test stand recorded water pressure, barrier fluid pressure, temperature, and number of cycles., representing ~ 40% of the SI. An additional separate test was conducted to measure the aging behavior of the rubber drive rings. The water pressure reservoir was held constant as 29 psi. Barrier fluid pressure remained relatively constant throughout the duration of the test but was seen to sink to as low as 10.1 psi. No barrier fluid leakage was observed throughout the test. A sudden failure occurred within the seal after the power to test machine was interrupted for a scheduled building maintenance procedure. Upon restarting, the main shaft seal lost all ability to prevent water ingress. The exact cause is not known but is believed to be either a seal assembly issue or a change in the alignment of the seal components during or following the power outage. Following seal disassembly, significant wear was seen on one of the graphite sealing rings. Based on these results it is recommended that a follow-on TEAMER be conducted to rectify protocol and assembly issues to further evaluate SI of this component. The support and participation of Verdant Power Inc, Dovetail Solutions LLC and Garlock Manufacturing Inc were instrumental in understanding the results. NREL thanks them for their significant effort.

13 HYDRO ENERGY↗

Durability of Pt-Co Alloy Polymer Electrolyte Fuel Cell Cathode Catalysts under Accelerated Stress Tests

The durability of Pt-Co alloy cathode catalysts supported on high surface area carbon is investigated by subjecting them to accelerated stress tests (ASTs). The catalysts had different initial Co contents and nanoparticle morphologies: a “spongy” porous morphology for the high-Co (H) content catalyst, and a fully alloyed crystalline morphology for the medium-Co (M) and low-Co (L) content catalysts. The specific activity of the catalysts depends on their initial Co content, morphology and nanoparticle size, and remained higher than 1000 μA/cm 2 -Pt after 27–50% Co loss. The H-catalyst electrode showed the smallest kinetic overpotentials (η c s ) due to higher initial Pt loading than the other two electrodes, but it had the fastest increase in ηcs with AST cycling due to lower Co retention; the L-catalyst electrode showed higher η c s due to a lower initial Pt loading, but had a smaller increase in η c s with aging due to higher Co retention; the M-catalyst electrode showed a similar increase in η c s with aging, but this increase was due to the combined effects of Co dissolution and electrochemically active surface area (ECSA) loss. In conclusion, the modeled increase in mass transfer overpotentials with aging correlates with the initial Pt loading, ECSA loss and the initial catalyst morphology