Experimental comparison of three methods to measure electron source properties for synchrotron radiation
Not Available
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
Not Available
Not Available
Not Available
Not Available
Not Available
Not Available
Not Available
In the aspect of longitudinal beam bunching, the bunching strength can be controlled by the rf cavity phase and voltage. However, these machine parameters are different from those that interact with the beam itself. In order to gain control of the beam-cavity interaction, cavity calibration must be performed. Furthermore, it relies on fitting the beam energy gain versus cavity phase to a calibration function. Under the conventional assumption of relativistic beam conditions, the calibration function is a first harmonic sinusoidal function (a sinusoidal function with a period of 2π). However, this expression is insufficient for a high-voltage bunching cavity. Due to beam acceleration inside the cavity, an energy bias and a second harmonic function should be included to modify the conventional calibration function, even for a relativistic electron beam. In this paper, we will derive this modification and provide a comparison to both the Coherent Electron Cooling Experiment and the IMPACT T simulation, respectively.
Not Available
The Facility for Rare Isotope Beams (FRIB) is a major nuclear physics facility for research with fast, stopped, and reaccelerated beams that was successfully commissioned in May 2022. A key capability of FRIB is the production of an acceleration of the uranium beam, but this capability requires the facility to work at the design limits of the lowest charge-to-mass ratio and the highest power density on the beam intercepting devices. This paper presents techniques for overcoming the significant challenges in accelerating the uranium beam, culminating in the demonstration of 10.4 kW on target, and the discovery of three new isotopes. The high-power uranium beam enabled us to produce and identify G 88 a , A 93 s , and S 96 e , within the first 24 h of operation. The successful uranium operation at FRIB sets a new record for accelerated uranium beam power above 10 kW and opens a new avenue of research with rare isotopes. Published by the American Physical Society 2024
We reconstructed the 3D Fourier intensity distribution of monodisperse prolate nanoparticles using single-shot 2D coherent diffraction patterns collected at DESY's FLASH facility when a bright, coherent, ultrafast x-ray pulse intercepted individual particles of random, unmeasured orientations. This first experimental demonstration of cryptotomography extended the expansion-maximization-compression framework to accommodate unmeasured fluctuations in photon fluence and loss of data due to saturation or background scatter. This work is an important step towards realizing single-shot diffraction imaging of single biomolecules.
Photovoltaic (PV) inverters are critical yet vulnerable components in modern energy systems, often acting as reliability bottlenecks that increase the levelized cost of energy (LCOE). To address this, this paper presents a comprehensive Failure Mode and Effects Analysis (FMEA) tailored for PV inverters. Leveraging field data and literature, we identify failure-prone components, such as capacitors,, and relays, and prioritize their risks based on quantitative Risk Priority Numbers (RPNs). The analysis reveals that surge-induced MOV short circuits, capacitor degradation, and environmental cooling fan failures dominate the risk profile. These findings provide a targeted framework for reliability improvement, guiding future efforts in predictive diagnostics, design optimization, and accelerated life testing strategies.
Particle accelerators enable scientists to study the fundamental structure of the universe, but have become the largest and most expensive of scientific instruments. In this project, we advanced the science and technology of laser-plasma accelerators, which are thousands of times smaller and less expensive than their conventional counterparts. In a laser-plasma accelerator, a powerful laser pulse exerts light pressure on an ionized gas, or plasma, thereby driving an electron density wave, which resembles the wake behind a boat. Electrostatic fields within this plasma wake reach tens of billions of volts per meter, fields far stronger than ordinary non-plasma matter (such as the matter that a conventional accelerator is made of) can withstand. Under the right conditions, stray electrons from the surrounding plasma become trapped within these “wake-fields”, surf them, and acquire energy much faster than is possible in a conventional accelerator. Laser-plasma accelerators thus might herald a new generation of compact, low-cost accelerators for future particle physics, x-ray and medical research. In this project, we made two major advances in the science of laser-plasma accelerators. The first of these was to accelerate electrons beyond 1 gigaelectronvolt (1 GeV) for the first time. In experimental results reported in Nature Communications in 2013, about 1 billion electrons were captured from a tenuous plasma (about 1/100 of atmosphere density) and accelerated to 2 GeV within about one inch, while maintaining less than 5% energy spread, and spreading out less than ½ milliradian (i.e. ½ millimeter per meter of travel). Low energy spread and high beam collimation are important for applications of accelerators as coherent x-ray sources or particle colliders. This advance was made possible by exploiting unique properties of the Texas Petawatt Laser, a powerful laser at the University of Texas at Austin that produces pulses of 150 femtoseconds (1 femtosecond is 10-15 seconds) in duration and 150 Joules in energy (equivalent to the muzzle energy of a small pistol bullet). This duration was well matched to the natural electron density oscillation period of plasma of 1/100 atmospheric density, enabling efficient excitation of a plasma wake, while this energy was sufficient to drive a high-amplitude wake of the right shape to produce an energetic, collimated electron beam. Continuing research is aimed at increasing electron energy even further, increasing the number of electrons captured and accelerated, and developing applications of the compact, multi-GeV accelerator as a coherent, hard x-ray source for materials science, biomedical imaging and homeland security applications. The second major advance under this project was to develop new methods of visualizing the laser-driven plasma wake structures that underlie laser-plasma accelerators. Visualizing these structures is essential to understanding, optimizing and scaling laser-plasma accelerators. Yet prior to work under this project, computer simulations based on estimated initial conditions were the sole source of detailed knowledge of the complex, evolving internal structure of laser-driven plasma wakes. In this project we developed and demonstrated a suite of optical visualization methods based on well-known methods such as holography, streak cameras, and coherence tomography, but adapted to the ultrafast, light-speed, microscopic world of laser-driven plasma wakes. Our methods output images of laser-driven plasma structures in a single laser shot. We first reported snapshots of low-amplitude laser wakes in Nature Physics in 2006. We subsequently reported images of high-amplitude laser-driven plasma “bubbles”, which are important for producing electron beams with low energy spread, in Physical Review Letters in 2010. More recently, we have figured out how to image laser-driven structures that change shape while propagating in a single laser shot. The latter techniques, which use the methods of computerized tomography, were demonstrated on test objects – e.g. laser-driven filaments in air and glass – and reported in Optics Letters in 2013 and Nature Communications in 2014. Their output is a multi-frame movie rather than a snapshot. Continuing research is aimed at applying these tomographic methods directly to evolving laser-driven plasma accelerator structures in our laboratory, then, once perfected, to exporting them to plasma-based accelerator laboratories around the world as standard in-line metrology instruments.
In the 1870s, English photographer Eadweard Muybridge captured motion pictures within one cycle of a horse’s gallop, which settled a hotly debated question of his time by showing that the horse became temporarily airborne. In the 1940s, Manhattan project photographer Berlin Brixner captured a nuclear blast at a million frames per second, and resolved a dispute about the explosion’s shape and speed. In this project, we developed methods to capture detailed motion pictures of evolving, light-velocity objects created by a laser pulse propagating through matter. These objects include electron density waves used to accelerate charged particles, laser-induced refractive index changes used for micromachining, and ionization tracks used for atmospheric chemical analysis, guide star creation and ranging. Our “movies”, like Muybridge’s and Brixner’s, are obtained in one shot, since the laser-created objects of interest are insufficiently repeatable for accurate stroboscopic imaging. Our high-speed photographs have begun to resolve controversies about how laser-created objects form and evolve, questions that previously could be addressed only by intensive computer simulations based on estimated initial conditions. Resolving such questions helps develop better tabletop particle accelerators, atmospheric ranging devices and many other applications of laser-matter interactions. Our photographic methods all begin by splitting one or more “probe” pulses from the laser pulse that creates the light-speed object. A probe illuminates the object and obtains information about its structure without altering it. We developed three single-shot visualization methods that differ in how the probes interact with the object of interest or are recorded. (1) Frequency-Domain Holography (FDH). In FDH, there are 2 probes, like “object” and “reference” beams in conventional holography. Our “object” probe surrounds the light-speed object, like a fleas swarming around a sprinting animal. The object modifies the probe, imprinting information about its structure. Meanwhile, our “reference” probe co-propagates ahead of the object, free of its influence. After the interaction, object and reference combine to record a hologram. For technical reasons, our recording device is a spectrometer (a frequency-measuring device), hence the name “frequency-domain” holography. We read the hologram electronically to obtain a “snapshot” of the object’s average structure as it transits the medium. Our published work shows numerous snapshots of electron density waves (“laser wakes”) in ionized gas (“plasma”), analogous to a water wake behind a boat. Such waves are the basis of tabletop particle accelerators, in which charged particles surf on the light-speed wave, gaining energy. Comparing our snapshots to computer simulations deepens understanding of laser wakes. FDH takes snapshots of objects that are quasi-static --- i.e. like Muybridge’s horse standing still on a treadmill. If the object changes shape, FDH images blur, as when a subject moves while a camera shutter is open. Many laser-generated objects of interest do evolve as they propagate. To overcome this limit of FDH, we developed .... (2) Frequency-Domain Tomography (FDT). In FDT, 5 to 10 probe pulses are fired simultaneously across the object’s path at different angles, like a crossfire of bullets. The object imprints a “streaked” record of its evolution on each probe, which we record as in FDH, then recover a multi-frame “movie” of the object’s evolving structure using algorithms of computerized tomography. When propagation distance exceeds a few millimeters, reconstructed FDT images distort. This is because the lenses that image probes to detector have limited depth of field, like cameras that cannot focus simultaneously on both nearby and distant objects. But some laser-generated objects of interest propagate over meters. For these applications we developed … (3) Multi-Object-Plane Phase-Contrast Imaging (MOP-PCI). In MOP-PCI, we image FDT-like probes to the detector from multiple “object planes” --- like recording an event simultaneously with several cameras, some focused on nearby, others on distant, objects. To increase sensitivity, we exploit a phase-contrast imaging technique developed by Dutch Nobel laureate Fritz Zernike in the 1930s. Using MOP-PCI we recorded single-shot movies of laser pulse tracks through more than 10 cm of air. We plan to record images of meter-long tracks of electron bunches propagating through plasma in an experiment at the Stanford Linear Accelerator Center (SLAC). This will help SLAC scientists understand, optimize and scale small plasma-based particle accelerators that have applications in medicine, industry, materials science and high-energy physics.
NorthStar Medical Isotope, LLC, is planning to produce 99 Mo through a γ,n reaction on 100 Mo. This pathway for 99 Mo production relies on the use of high-power electron accelerators, which are not currently commercially available. IBA Industrial announced in its Summer 2017 newsletter (http://iba-industrial.com/emailing/2017-beamline/index.html) that they have begun working on pulsed Rhodotron features (New Horizon project). This accelerator is capable of producing a high power and high energy electron beam suitable for production via a photonuclear route. Argonne National Laboratory (Argonne), in collaboration with Los Alamos National Laboratory (LANL), provided assistance to NorthStar in technology development. Over the course of several years, we have conducted several demonstrations of the technology that proved the feasibility of photo-nuclear approach. The target, designed by LANL, is composed of a series of 99 Mo disks held in a target holder with cooling gaps between the thin disks. Cooling of the target is provided by flowing helium gas under high pressure through the target holderHandling the high-power beam requires a carefully designed beam transport system because of likely vacuum failure if the beam strikes an uncooled part of the system. This publication summarizes recommendations on the beam transport line equipment, costs, and on the optional components.
Automation can revolutionize the use of ultrafast laser ablation and plasma-focused ion beam (PFIB) techniques for high-throughput, reproducible cross-sectioning and various sample preparation in materials characterization. As these methods become essential for analyzing complex energy materials and next-generation devices, efficient, standardized workflows are needed to minimize variability and enhance precision. This work highlights our advancements in developing automated processes for sample preparation that integrates machine learning, workflow optimization, and large-scale data acquisition to improve efficiency and scalability in applications such as electrolyzers, photovoltaic cells, and microelectronics. To streamline cross-sectioning and lamella fabrication, we have implemented fully automated workflows that standardize laser ablation and PFIB milling sequences. These workflows incorporate pre-programmed protocols for material removal, alignment, and thinning, reducing user intervention and ensuring consistency across different sample types. Machine learning algorithms further enhance automation by predicting optimal milling strategies and adapting parameters based on material properties and sectioning requirements. This approach significantly improves throughput while maintaining the structural integrity of prepared samples for high-resolution imaging and analysis, including transmission electron microscopy. Beyond sample preparation, our automation platform enables the acquisition of large, high-resolution datasets through serial sectioning, image alignment, and 3D reconstruction. These automated routines facilitate multi-scale characterization, capturing structural and compositional details from the nanoscale to the device level. By reducing variability and increasing efficiency, our automated approach enhances defect analysis, failure diagnostics, and process optimization, accelerating advancements in materials research and device engineering.