Ground impingement of supersonic jets from nozzles with various exit geometries

Aerodynamc and acoustic measurements of single and twin free and impinging jets were made for circular convergent and CD nozzles, rectangular CD nozzles, and D-shaped convergent nozzles. Measured shock cell lengths and screech tone frequencies compare well with existing theory. Noise due to jet impingement correlates on the basis of the nozzle-to-ground distance relative to the free jet shock structure, with the highest sound pressure levels generally due to jet impingement tones. All nozzle types experienced near-field OASPL of 160 dB at some nozzle-to-ground distances, including the CD nozzles operating at their design pressure. The effect of the second jet was to sometimes increase levels due to twin jet resonance and at other times reduce levels due either to suppression of the screech/impingement feedback process or more simply by acoustic interference of the noise produced by the two jets.

Norum, Thomas D.↗

Preliminary Analysis of Moog SureFly Electric Motor Noise Measurements

The results of acoustics measurements on the installed and unloaded axial-flux electric motor used on the Moog SureFly® vehicle are presented and compared to previous ground run-up measurements for the vehicle. The directivity of the motor was found to be significantly different than that obtained for much smaller 2 – 4 kW radial flux motors tested previously in the Acoustic Test Laboratory at NASA Glenn. Significant radiation occurred at shaft orders between 17 and 20 and at order 30. Peak radiation levels occurred near the highest speeds expected for the vehicle. There was an indication that some of the tones appearing in the spectra obtained in the previous ground run-up test were associated with the motor.

Urban Air Mobility↗

22” ADP Fan Rig Liners Design Report

A liner design study was conducted as part of a cooperative effort between five (5) government/industry teams that together seek to demonstrate the technology for designing and manufacturing acoustic liners that are twenty five percent (25%) more efficient than 1992 technology liners. The study emphasized teaming collaboration. The improved liners were designed by Pratt & Whitney and Boeing Airplane Company and built by Rohr Inc, and will be tested in the NASA/P& W 22-inch ADP fan rig at NASA Lewis Research Center's 9' x 15' wind tunnel. Design guidelines and decisions were made collectively during monthly design review telecons and at the formal final design review. The tools that were used to design the new improved liners were not new, but the process that was developed as part of this study that led into the evaluation and selection of the final and best liner designs is new. Until now, the liner design process as practiced by different industry teams varied greatly. Some procedures were based on empirical liner attenuation databases which could not adequately account for engine-to-engine hardwall fan noise spectral differences, while others were entirely theoretical. And regardless of which method one chose, the major difficulty was still the lack of understanding and knowledge of the actual hardwall fan source noise modal structure and farfield SPL spectra. The NASA-led effort to attempt actual measurements of the fan source noise modal structure by means of the rotating microphone array is expected to contribute significantly to the understanding of the nature of the fan tone noise modes, but the application to broadband noise is still a long way off. The new design process included consideration of the measured fan tone modes, but for the majority of the spectra a separate, systematic process was used. It is a common practice in the engine/nacelle industry that acoustic liners for new products are designed before actual measured hardwall engine far-field noise spectra are available. Target noise spectra are normally derived from existing engine noise databases with some adjustments to absolute SPLs and frequencies. This practice has been acceptable as long as the new engine was a derivative of the base engine. However, in the case of the ADP, the transition from a current engine base is too - great, and the adjustments could not adequately account for the quantum changes in SPL spectral differences. Examples were the 1992 single degree of freedom (SDOF) inlet and aft liners (designed by P&W) that would be used as the baseline liners against which the new improved liners' efficien¬cies would -be measured. As will be shown, these baseline liners have been found to be deeper than the desire optimum depths. The new liner design process begins with the selection of the target hard wall fan noise spectra. These spectra were obtained by scaling up (5.91 scale factor) the measured hardwall fan spectral data from the 22” ADP fan rig. Next, the modal energy contents for each 1/3-octave band center frequency of these hardwall fan noise spectra are estimated. (Within each 1/3-octave band center frequency, the model energy distribution approximation is for both tone and broadband noise). For the inlet noise, P&W uses a derivative of the NASA Lewis (Ed Rice's) method of classifying; and grouping propagating modes by their cutoff ratios. The next step is to assign energy level to each group of modes having the same cutoff ratio. In Ed Rice's model, the modes were grouped according to ten (10) cutoff ratio intervals with center values located at 1.026, 1.085, 1.155, 1.24, 1.35, 1.49, 1.69, 2.0, and 4.47 (with equal number of modes in each interval). The modes were assumed to have equal energy. P&W’s model expands the cutoff ratio-mode grouping into two hundred (200) smaller cutoff ratio intervals with center values located f1".'m 1.003 to 11.5 in 199 increasing incremental intervals. Next, P&W's model uses a "2-parameter" normal distribution as a template to assign energy levels to these 200 pre-determined cutoff ratio values (for each 1/3-octave band center frequency). In the past, P&W had conducted an extensive study to determine what "2-parameter" values are appropriate for fullscale inlet liners, and had developed a set of twenty-four (24) "2-pararneter" values (i.e. one for each 1/3-octave frequency band) that when used in Ed Rice's Inlet Attenuation Prediction Method produced predicted liner attenuations that closely matched measured liner attenuations from several P&W's engines. In the absence of actual measured tone and broadband modal data from the 22" ADP rig, the process will use P&W's proprietary set of "2-parameter" values for this liner design study. For the aft noise, Boeing uses a modal energy approximation that the "transport energy" of each propagating mode is equal. This approximation is almost the same as the equal energy per mode approximation, except for modes that are near cutoff. Boeing's model forces these modes to have lower energy levels. Both P&W and Boeing agreed that the "transport energy" approximation should work well for the ADP aft fan noise which appears to be dominated by broadband noise. The design process then proceeds to calculate the optimum liner impedances for each frequency in both the inlet and the aft. These optimum impedances represent the target impedances that the designed liners should have. Liners with impedances matching the optimum impedances at all frequencies are "ideal" liners. These ideal liners are theoretically the best liners. Unfortunately, it has been showed that it is impossible to design and build such ideal liners. The next best liners are ones that have impedances matching the optimum impedances over some frequency range (not all frequencies as for the ideal). This is accomplished by the use of "frequency weightings". Several of P&W's and Boeing's existing computer decks were used for optimizing and matching the designed liner impedances to the target optimum values (with the various frequency weightings specified). The optimization produces liner candidates with predicted liner impedances and descriptions of their physical liner characteristics. These candidate liner impedances are then used to predict their spectral attenuation characteristics which are then used together with the target hardwall fan noise spectra to determine the resulting treated noise spectra and PNLT values. Further optimization around the selected candidate designs yield final designs that are best in PNLT attenuations. Use of the optimization decks allowed a large number of liner candidates to be screened in a relatively short period of time. This design process is systematic and is efficient. The new inlet SDOF liner design obtained from the improved process was predicted to be 34% more effective (per unit area) than the 1992 baseline inlet liner. This inlet liner design is a 112 rayl wovenwiremesh facesheet over a 0.312-inch deep honeycomb core. The new aft SDOF liner design was predicted to be 52% more efficient than the aft baseline liner. The new aft SDOF liner is "segmented" with a shallower liner on the core cowl (inner duct wall) and a deeper liner on the fan cowl (outer duct wall). The shallower liner is a 70.6 rayl woven-wiremesh facesheet over a 0.141-inch deep honeycomb core. The deeper liner is a 68 rayl woven-wiremesh facesheet over a 0.309-inch deep honeycomb core. All liner dimensions are for the 22-inch model-scale ADP fan rig liners. The selected advanced liners are "segmented" double-layer (DDOF) liners for the inlet and aft locations. Also, for the inlet, a bulk liner with ceramic foam for wider broadband noise absorption was also selected. Triple-layer liner designs were not considered since the model scaled liners ( 1/5. 91) were dimensionally too small to be built correctly, and irrin earlier concept study, Boeing found a triple-layer to have only very small benefits over a double-layer. The inlet DDOF liner was predicted to be 83% more effective than the baseline. The inlet DDOF design is a 78 rayl facesheet over a 0.080 top cavity depth, a 68 rayl septum and a 0.227-inch bottom cavity depth. The inlet bulk liner is a 60 rayl facesheet over a 0.33-inch deep honeycomb filled with high temperature (HTP) ceramic foam with a density of 4.8 lb/cu.ft and a flow resistivity of 167 rayl/cm. The inlet bulk liner was predicted to be 83% more effective than the baseline liner. The aft DDOF liners are segmented with a shallower liner on the core cowl and a deeper liner on the fan cowl. The shallow DDOF liner is a 49.8 rayl facesheet over a 0.093-inch top cavity depth, a septum of 88.2 rayls over a 0.181-inch bottom cavity depth. The deep DDOF liner is a 12.9 rayl facesheet over a 0.140-inch top cavity depth, a septum of 53.1 ray ls over a 0.258-inch botom cavity depth. The segmented aft DDOF liners were predicted to be 86% more efficient than the baseline liner.

turbofan acoustic treatment↗

Periodic Time-Domain Nonlocal Nonreflecting Boundary Conditions for Duct Acoustics

Periodic time-domain boundary conditions are formulated for direct numerical simulation of acoustic waves in ducts without flow. Well-developed frequency-domain boundary conditions are transformed into the time domain. The formulation is presented here in one space dimension and time; however, this formulation has an advantage in that its extension to variable-area, higher dimensional, and acoustically treated ducts is rigorous and straightforward. The boundary condition simulates a nonreflecting wave field in an infinite uniform duct and is implemented by impulse-response operators that are applied at the boundary of the computational domain. These operators are generated by convolution integrals of the corresponding frequency-domain operators. The acoustic solution is obtained by advancing the Euler equations to a periodic state with the MacCormack scheme. The MacCormack scheme utilizes the boundary condition to limit the computational space and preserve the radiation boundary condition. The success of the boundary condition is attributed to the fact that it is nonreflecting to periodic acoustic waves. In addition, transient waves can pass rapidly out of the solution domain. The boundary condition is tested for a pure tone and a multitone source in a linear setting. The effects of various initial conditions are assessed. Computational solutions with the boundary condition are consistent with the known solutions for nonreflecting wave fields in an infinite uniform duct.

Watson, Willie R.↗

Effects of sound level fluctuations on annoyance caused by aircraft-flyover noise

A laboratory experiment was conducted to determine the effects of variations in the rate and magnitude of sound level fluctuations on the annoyance caused by aircraft-flyover noise. The effects of tonal content, noise duration, and sound pressure level on annoyance were also studied. An aircraft-noise synthesis system was used to synthesize 32 aircraft-flyover noise stimuli representing the factorial combinations of 2 tone conditions, 2 noise durations, 2 sound pressure levels, 2 level fluctuation rates, and 2 level fluctuation magnitudes. Thirty-two test subjects made annoyance judgements on a total of 64 stimuli in a subjective listening test facility simulating an outdoor acoustic environment. Variations in the rate and magnitude of level fluctuations were found to have little, if any, effect on annoyance. Tonal content, noise duration, sound pressure level, and the interaction of tonal content with sound pressure level were found to affect the judged annoyance significantly. The addition of tone corrections and/or duration corrections significantly improved the annoyance prediction ability of noise rating scales.

Mccurdy, D. A.↗

Aerodynamic-whistles-based ultrasonic tone generators for bat deterrence

Novel ultrasonic bat deterrents based on aerodynamic whistles are proposed and investigated experimentally and numerically for their ability to generate ultrasound. The baseline deterrent, a single-whistle design inspired by Beeken [“Fluid ultrasonic generator,” U.S. patent 3,432,804 (1969)], is examined first. It consists of two resonating cavities/chambers. The whistle is “powered” by a regulated high-pressure air supply, and the performance of the whistle is examined for a range of supply pressures. Far-field acoustic measurements in the 20 Hz–50 kHz frequency range are made in an anechoic chamber. The noise measurements are supplemented with two- and three-dimensional unsteady Reynolds-averaged Navier–Stokes (uRANS) simulations to investigate the mechanisms of ultrasound generation. The Ffowcs Williams–Hawkings acoustic analogy is used with the three-dimensional uRANS results to predict the far-field radiation. The far-field acoustic predictions are in good agreement with the measurements in the anechoic chamber. The peak frequency (fundamental) of the radiated ultrasound of the baseline deterrent is approximately 23 kHz. Harmonics and a sub-harmonic of the fundamental tone are also observed. The numerical simulations show that the two resonating chambers of the baseline deterrent operate out-of-phase and Helmholtz resonance determines the whistling frequency over the range of supply air pressure considered. A six-whistle deterrent targeting a broad spectral coverage in the 20–50 kHz frequency range is designed, fabricated, and tested in the anechoic chamber. Each whistle in the deterrent is obtained by geometrically scaling the baseline whistle. Measurements show that the six-whistle ultrasound deterrent generates ultrasound with six dominant peaks in the designed frequency range when the supply air pressure exceeds 5 psig. The proposed ultrasound devices can be used for a variety of purposes including bat deterrence at wind turbines.

42 ENGINEERING↗

Performance of an Active Noise Control System for Fan Tones Using Vane Actuators

An Active Noise Control (ANC) system for ducted fan noise was built that uses actuators located in stator vanes. The custom designed actuators A,ere piezoelectric benders manufactured using THUNDER technology. The ANC system was tested in the NASA Active Noise Control Fan rig. A total of 168 actuators in 28 stator vanes were used (six per vane). Simultaneous inlet and exhaust acoustic power level reductions were demonstrated for a fan modal structure that contained two radial modes in each direction. Total circumferential mode power levels were reduced by up to 9 dB in the inlet and 3 dB in the exhaust. The corresponding total 2BPF tone level reductions were by 6 dB in the inlet and 2 dB in the exhaust. Farfield sound pressure level reductions of up to 17 dB were achieved at the peak mode lobe angle. The performance of the system was limited by the constraints of the power amplifiers and the presence of control spillover. Simpler control/actuator systems using carefully selected subsets of the full system and random simulated failures of up to 7% of the actuators were investigated. (The actuators were robust and none failed during the test). Useful reductions still occurred under these conditions.

Sutliff, Daniel L.↗

The theoretical and experimental investigations on multiple pure tone noise, part 1

A theoretical and experimental investigation is described on multiple pure tone noise. Based on a two-dimensional and inviscid flow model, an analysis is developed to predict the generation and subsequent evolution of multiple pure tone noise from prescribed blade-to-blade nonuniformities in the rotor geometry. The results show that even small nonuniformities within manufacturing tolerances can cause a significant amount of multiple pure tone noise. Among the different kinds of nonuniformities investigated, errors in blade spacings are a weaker generator of multiple pure tone noise than errors in blade stagger or blade contours. Experimental investigations of the effects of the rotor relative Mach number, incidence angle and length of the inlet duct on the evolution of the multiple pure tone noise are conducted with a known distribution of rotor nonuniformities. The model fan is operated, in Freon 12, in a closed loop acoustical facility.

Kantola, R. A.↗

Measured and predicted noise of the Avco-Lycoming YF-102 turbofan noise

Acoustic testing of the AVCO-Lycoming YF-102 turbofan engine was done on a static test stand in support of the quiet short-haul research aircraft acoustic design. Overall noise levels were dominated by the fan noise emanating from the exhaust duct, except at high power settings when combination tones were generated in the fan inlet. Component noise levels, calculated by noise prediction methods were in reasonable agreement with the measured results. Far-field microphones placed at ground level were found superior to those at engine centerline height, even at high frequencies.

Clark, B. J.↗

Measured and predicted noise of the AVCO-Lycoming YF-102 turbofan engine

Acoustic testing of the AVCO-Lycoming YF-102 turbofan engine was done on a static test stand at Lewis Research Center in support of the Quiet Short-Haul Research Aircraft (QSRA) acoustic design. Overall noise levels are dominated by the fan noise emanating from the exhaust duct, except at high power settings when combination tones are generated in the fan inlet. Component noise levels, calculated by noise prediction methods developed at Lewis Research Center for the ANOP program, are in reasonable agreement with the measured results. Far-field microphones placed at ground level were found superior to those at engine centerline height, even at high frequencies.

Clark, B. J.↗

The design and flight test of an engine inlet bulk acoustic liner

This paper summarizes the design, fabrication and flight evaluation of a Kevlar acoustic liner configuration for a JT15D turbofan engine. The liner was designed to suppress, by a measurable amount, a dominant (13,0) BPF tone. This tone or spinning mode was produced for research purposes by installing 41 circumferentially distributed small diameter rods upstream of the 28 fan blades. Duct liner attenuations calculated by a finite element procedure were compared to far field power (insertion) losses deduced from flight data. The finite element program modeled the variable geometry of the JT15D inlet and used a uniform flow with a boundary layer roll-off to model the inlet flow field. Calculated liner losses were generally conservative. That is, measured far field power losses were generally greater than attenuations calculated by the finite element computer program.

Lester, H. C.↗

Control of Thermo-Acoustics Instabilities: The Multi-Scale Extended Kalman Approach

"Multi-Scale Extended Kalman" (MSEK) is a novel model-based control approach recently found to be effective for suppressing combustion instabilities in gas turbines. A control law formulated in this approach for fuel modulation demonstrated steady suppression of a high-frequency combustion instability (less than 500Hz) in a liquid-fuel combustion test rig under engine-realistic conditions. To make-up for severe transport-delays on control effect, the MSEK controller combines a wavelet -like Multi-Scale analysis and an Extended Kalman Observer to predict the thermo-acoustic states of combustion pressure perturbations. The commanded fuel modulation is composed of a damper action based on the predicted states, and a tones suppression action based on the Multi-Scale estimation of thermal excitations and other transient disturbances. The controller performs automatic adjustments of the gain and phase of these actions to minimize the Time-Scale Averaged Variances of the pressures inside the combustion zone and upstream of the injector. The successful demonstration of Active Combustion Control with this MSEK controller completed an important NASA milestone for the current research in advanced combustion technologies.

Le, Dzu K.↗

Jet noise modification by the 'whistler nozzle'

The farfield noise characteristics of a subsonic whistler nozzle jet are measured as a function of Mach number (0.25, 0.37, and, 0.51), emission angle, and excitation mode. It is shown that a whistler nozzle has greater total and broadband acoustic power than an excited contraction nozzle; and that the intensity of far-field noise is a function of emission angle, Mach number, and whistler excitation stage. The whistler nozzle excitation produces broadband noise amplification with constant spectral shape; the broadband noise amplification (without associated whistler tones and harmonics) increases omnidirectionally with emission angle at all Mach numbers; and the broadband amplification factor decreases as Mach number and emission angle increase. Finally the whistler nozzle is described as a very efficient but inexpensive siren with applications in not only jet excitation but also acoustics.

Hasan, M. A. Z.↗

Active Control of Fan Noise by Vane Actuators

An active noise control system for ducted fan noise was built that uses actuators located in stator vanes. The actuators were piezoelectric benders manufactured using the THUNDER technology and were custom designed for the application. The active noise control system was installed in the NASA ANCF rig. Four actuator array with a total of 168 actuators in 28 stator vanes were used. Simultaneous reductions of acoustic power in both the inlet and exhaust duct were demonstrated for a fan disturbance that contained two radial mode orders in both inlet and exhaust. Total power levels in the target modes were reduced by up to 9 dB in the inlet and total tone levels by over 6 dB while exhaust power levels were reduced by up to 3 dB. Far field sound pressure level reductions of up to 17 dB were observed. A simpler control system, matched to the location of the disturbance with two radial actuator arrays, was demonstrated to control total acoustic power in four disturbance modes simultaneously in inlet and exhaust. The vane actuator met the requirements given for the ANCF, although in practice the performance of the system was limited by the constraints of the power amplifiers and the presence of control spillover. The vane actuators were robust. None of the 168 vane actuators failed during the tests.

Curtis, Alan R. D.↗

Acoustic Testing of a High-Tip-Speed Fan with Bypass-Duct Liners

Under a pair of Space Act Agreements between NASA and Honeywell Aerospace, a model-scale (22 in.-diameter fan) acoustic wind tunnel test was carried out in the fall of 2014 in the NASA Glenn Research Center 9- by 15-Foot Low-Speed Wind Tunnel. The goal was to obtain acoustic pressure measurements for far-field, inlet and exit rotating rake, and in-duct microphone locations. This supersonic-tip-speed fan was tested in three bypass duct configurations: hard-wall, traditional liner, and advanced multiple-degree-of-freedom. Limited aerodynamic data was collected to verify the expected operating conditions. Preliminary analysis of the acoustic data finds it suitable for use in evaluating current NASA and Honeywell Aerospace acoustic tools and liner design practices.

Noise↗

Investigation of the Statistics of Pure Tone Sound Power Injection from Low Frequency, Finite Sized Sources in a Reverberant Room

The effect of finite source size on the power statistics in a reverberant room for pure tone excitation was investigated. Theoretical results indicate that the standard deviation of low frequency, pure tone finite sources is always less than that predicted by point source theory and considerably less when the source dimension approaches one-half an acoustic wavelength or greater. A supporting experimental study was conducted utilizing an eight inch loudspeaker and a 30 inch loudspeaker at eleven source positions. The resulting standard deviation of sound power output of the smaller speaker is in excellent agreement with both the derived finite source theory and existing point source theory, if the theoretical data is adjusted to account for experimental incomplete spatial averaging. However, the standard deviation of sound power output of the larger speaker is measurably lower than point source theory indicates, but is in good agreement with the finite source theory.

Smith, Wayne Farrior↗

Improved Broadband Liner Optimization Applied to the Advanced Noise Control Fan

The broadband component of fan noise has grown in relevance with the utilization of increased bypass ratio and advanced fan designs. Thus, while the attenuation of fan tones remains paramount, the ability to simultaneously reduce broadband fan noise levels has become more desirable. This paper describes improvements to a previously established broadband acoustic liner optimization process using the Advanced Noise Control Fan rig as a demonstrator. Specifically, in-duct attenuation predictions with a statistical source model are used to obtain optimum impedance spectra over the conditions of interest. The predicted optimum impedance information is then used with acoustic liner modeling tools to design liners aimed at producing impedance spectra that most closely match the predicted optimum values. Design selection is based on an acceptance criterion that provides the ability to apply increased weighting to specific frequencies and/or operating conditions. Constant-depth, double-degree of freedom and variable-depth, multi-degree of freedom designs are carried through design, fabrication, and testing to validate the efficacy of the design process. Results illustrate the value of the design process in concurrently evaluating the relative costs/benefits of these liner designs. This study also provides an application for demonstrating the integrated use of duct acoustic propagation/radiation and liner modeling tools in the design and evaluation of novel broadband liner concepts for complex engine configurations.

Nark, Douglas M.↗

xEMU Suit Integrated Audio Communications System: Ambient and EVA Pressure Testing System Performance

Testing across several airlock and EVA thermal and pressure scenarios has demonstrated that the Integrated Audio System of NASA’s Exploration Extravehicular Mobility Unit (xEMU) spacesuits transmits and receives intelligible audio communications without the use of a commcap or similar worn device. The xEMU audio system consists of internal loudspeakers and digital microphones (Integrated Communications System –ICS) combined with an adaptive Acoustic Echo Canceller (AEC), outbound voice operated transmission (VOX), and automatic gain control (AGC). Transducers are mounted in an “exploded commcap” configuration with helmet-attached speakers near the ears and three microphones positioned at the collar. The AGC removes inbound audio signals (e.g.,suit, Mission Control, Lander, C&W tones) from the outbound comms stream, reducing echo and feedback (squeal) in low-noise suit environments. The reduction of worn communication equipment increases crewmember comfort, range of movement, and situational awareness. However, test results also highlight the need for proper fan, duct, pump, and gas flow integration with suit acoustics and audio. Ductwork may serve as waveguides for various component and structure-borne noise. Sharply angled ducts can generate turbulent-flow noise. Gas flow from inlets above the crewmember’s head can generate noise when cascading over the faceplate and collar (or commcap) microphones. Sufficient acoustic noise levels (1) require increased gain to boost inbound audio, and (2) may distort signals resulting in AEC disruption or artifacts. Suit-noise levels decline with reduced pressure (density), but then elevated speech and audio effort/power become necessary. Whether the Integrated Audio System, commcap, or other device is used, suit acoustic noise can mask speech in outbound comms. This reduces intelligibility and requires other AECs/devices to suppress comms noise. Yet, adjusting a few components may yield significant improvement. We discuss xEMU audio functionality, demonstrate how acoustical treatment combined with inbound signal conditioning improved clarity during tests, and discuss future modifications.