Search NASASearch

SEARCH · Search NASA

Results for “active site identification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

262 records · Page 14

Spacecraft Fire Safety Predictions using Verified Saffire Model

A model developed using Fire Dynamics Simulator (FDS) that aimed to determine the effect of a fire in a spacecraft was validated by data collected during the Saffire campaign. The model used inlet and outlet temperatures and CO 2 concentrations of the Saffire payload where fire spread was taking place to determine the amount of heat and combustion products that made it into Northrop Grumman’s Cygnus vehicle. The model was then validated using six remote sensors in various places in the vehicle, as well as a far field device (FFD) in the open zenith section that was representative of average vehicle values. The current work focuses on using the model to predict fire safety scenarios. One simulation aimed to determine the fate of HCl, which sticks to surfaces. The model prediction showed that the HCl was removed from the atmosphere rapidly. This compared well against the FFD data in the Saffire VI campaign event where a bottle of 5% HCl was released into the vehicle. An additional simulation where the Environmental Control and Life Support System (ECLSS) was shut off once the FFD reached 5 ppm of HCl showed that HCl stayed in the atmosphere considerably longer. Continuing the simulation with the ECLSS activated and after temperatures returned to their initial conditions, resulted in a rapid removal of HCL similar to that observed in the original HCl release scenario model. Finally, a simulation that used the heat release rate from a lithium-ion battery test to determine the effect it would have on a spacecraft was performed. This simulation used a heat addition rate that is considerably higher than what was determined from the burning of solid fuels in the Saffire campaign and hence produced a non-trivial temperature increase in more locations within the vehicle.

Fire Safety

SERFE Ground Unit EVA Series After Three Year Spacesuit Stowage Period

NASA’s spacesuit government reference design for returning to the Moon is called the Exploration Extravehicular Mobility Unit (xEMU). The xEMU subassembly that provides life support, such as oxygen and thermal control, is the Portable Life Support System (PLSS). Inside the PLSS is a new technology that NASA wanted to test to provide cooling to the crew during EVAs (ExtraVehicular Activity). This technology is called the Spacesuit Water Membrane Evaporator (SWME). In order to test SWME in an improved thermal control loop (TCL) both on Earth and in Space, the Spacesuit Evaporation Rejection Flight Experiment (SERFE) was created. The Ground unit, or testbed at Johnson Space Center (JSC), tested the cooling technology in Earth’s gravity, while the Flight unit, or payload on the International Space Station (ISS), tested the cooling technology in micro-gravity. Since fluids flow differently in micro-gravity, testing in both environments would provide important data for improving cooling performance during EVAs. Both units completed 25 simulated EVAs with the same settings so SWME performance on the ground could be compared to the ISS. The Flight unit was completed first and performed EVAs on the ISS between 2020 and 2022. The Ground unit performed EVAs between 2021 and 2022. When the Flight unit came back from the ISS, it was taken apart for analysis. This analysis looked at how well SWME was able to maintain its heat rejection capability after various dwell times, such as a 90 day Airlock Coolant Loop Recovery (ALCLR) cycle, when the Extravehicular Mobility Unit (EMU) currently on the ISS would normally need maintenance. After a three year simulated spacesuit dwell, the Ground unit performed another EVA series in 2025 to test SWME’s shelf life. The results from this test series will inform mission planning as NASA plans to go back to the Moon and beyond.

Michael Lewandowski

Recirculating and Sub-Atmospheric Rapid Cycle Amine Swing Bed Testing at Various Metabolic Profiles, Temperatures, and Half-Cycle Times

Sixty years since the first spacewalk, NASA’s Extravehicular Mobility Unit (xEMU) exploration space suit has undergone numerous design improvements and iterations. As commercial manufacturers develop next-generation systems to support increasingly complex missions, including Moon-to-Mars architecture prototyping and the design of the Martian Portable Life Support System (PLSS), material selection and individual subunit testing under realistic metabolic and pressure conditions are paramount. To determine whether a reusable carbon dioxide (CO 2 ) scrubber design and adsorbent can be utilized in new suit configurations, an all-encompassing test rig is required to compare existing and newly developed technologies. The test rig must be capable of sub-atmospheric testing, calibrated humid CO 2 dosing, and facilitation of the evaluation of sorbents across a wide range of operational requirements. Recently, XploSafe has developed an Extravehicular Mobility Unit (xEMU) testing rig specifically designed to explore CO 2 and humidity control materials for spacesuits. This closed-loop recirculating swing bed (Rapid Cycle Amine Test Rig) was utilized to compare adsorbent utility across a wide range of xEMU operating conditions. Following successful testing with Xplo-SA9T over multiple simulated eight-hour Extravehicular Activity (EVA) tests, improvements to the test stand were considered. Regeneration vacuum supply within the test rig was updated to more closely resemble space vacuum, theoretically increasing half-cycle timing. An improved water vapor delivery system was incorporated to dose a wider calibrated range of humidity over both short and long-duration EVAs. A range of metabolic profiles between 800 and 3000 BTU/h were tested, and the corresponding average CO 2 steady-states were compared. The effect of dosing temperature at the adsorbent bed inlet between 10 and 40 ̊C and the corresponding CO 2 removal efficiency was also evaluated.

John R Tidwell

Coma Physics of an Interstellar Object: JWST Spatial-Spectral Mapping of 3I/ATLAS

We report a survey of molecular emission from cometary volatiles using the James Webb Space Telescope (JWST) toward interstellar object 3I/ATLAS carried out on UT 2025 December 22 and 23 at a heliocentric distance (\rh{}) of $2.37-2.41$ au. These measurements of CO, \ce{CO2}, \ce{H2O}, \ce{CH3OH}, and \ce{CH4} sampled molecular chemistry in 3I/ATLAS as it receded from its encounter with our Sun and entered the vicinity of the \ce{H2O} ice line --- the region between \rh{} = $2-3$ au where the temperature becomes too low for H$_2$O to vigorously sublime and CO and \ce{CO2} begin to control the overall activity. CO was the most abundant molecule, followed by \ce{H2O} and \ce{CO2}, whose molecular abundances with respect to CO were $(40.5\pm3.1)\%$ and ($41.6\pm0.3)\%$, respectively. This work presents spatial-spectral maps of column density and rotational temperature as a function of distance from the nucleus for all detected species. The spatial distributions of both quantities were highly anisotropic for the apolar species in the coma of 3I/ATLAS, yet were more nearly symmetric for the polar molecules. These results demonstrate how volatiles were segregated in the nucleus ices of 3I/ATLAS and reveal heating and cooling mechanisms in its coma. Derived maps of the ortho-to-para ratio (OPR) for \ce{H2O} were flat with increasing distance from the nucleus and consistent with a coma-averaged value $\mathrm{OPR}=2.7\pm0.2$, slightly less than the expected equilibrium value of three.

Nathan X Roth

SERFE Ground Unit EVA Series After Three Year Spacesuit Stowage Period

NASA’s spacesuit government reference design for returning to the Moon is called the Exploration Extravehicular Mobility Unit (xEMU). The xEMU subassembly that provides life support, such as oxygen and thermal control, is the Portable Life Support System (PLSS). Inside the PLSS is a new technology that NASA wanted to test to provide cooling to the crew during EVAs (ExtraVehicular Activity). This technology is called the Spacesuit Water Membrane Evaporator (SWME). In order to test SWME in an improved thermal control loop (TCL) both on Earth and in Space, the Spacesuit Evaporation Rejection Flight Experiment (SERFE) was created. The Ground unit, or testbed at Johnson Space Center (JSC), tested the cooling technology in Earth’s gravity, while the Flight unit, or payload on the International Space Station (ISS), tested the cooling technology in micro-gravity. Since fluids flow differently in micro-gravity, testing in both environments would provide important data for improving cooling performance during EVAs. Both units completed 25 simulated EVAs with the same settings so SWME performance on the ground could be compared to the ISS. The Flight unit was completed first and performed EVAs on the ISS between 2020 and 2022. The Ground unit performed EVAs between 2021 and 2022. When the Flight unit came back from the ISS, it was taken apart for analysis. This analysis looked at how well SWME was able to maintain its heat rejection capability after various dwell times, such as a 90 day Airlock Coolant Loop Recovery (ALCLR) cycle, when the Extravehicular Mobility Unit (EMU) currently on the ISS would normally need maintenance. After a three year simulated spacesuit dwell, the Ground unit performed another EVA series in 2025 to test SWME’s shelf life. The results from this test series will inform mission planning as NASA plans to go back to the Moon and beyond.

SWME

Physics-Guided Deep Learning for Complex System Health Management and Decision Making

The landscape of complex engineered systems is rapidly evolving, from smart manufacturing facilities to next-generation transportation vehicles. As these systems become increasingly sophisticated and interconnected, the need for advanced health management systems grows ever more critical. These systems must go beyond simple monitoring, actively predicting potential failures before they occur. This paradigm shift from fixed maintenance schedules to condition-based predictions is key to optimizing system performance, enhancing safety, and paving the way for autonomous decision-making across various industries. Whether in industrial processes, energy systems, or advanced transportation, the ability to anticipate and prevent failures is becoming a cornerstone of operational excellence. To accurately predict the future health of any complex system, knowledge of its current health state and future operational conditions is essential. Recent advancements in data-driven algorithms have generated growing interest in artificial intelligence for industrial applications. However, the limitations of pure data-driven methods, particularly in industries where data acquisition is costly and limited, have become apparent. This has led to a focus on blending physics with data-driven algorithms, mitigating the drawbacks of both approaches while emphasizing their respective advantages. This research proposes a novel framework for integrating physics-based performance models with deep learning algorithms for the prognostics of complex safety-critical systems. In this approach, physics-based models serve as a blueprint, capturing fundamental system behaviors, while deep learning algorithms, leveraging real-world sensor data, fill in gaps and identify subtle patterns indicative of potential problems. This hybrid methodology, utilizing techniques such as Physics-Informed Neural Networks (PINNs), offers a powerful solution for predicting system health. By fusing domain knowledge with data-driven insights, this approach promises more accurate, adaptable, and reliable models for health prediction. The resulting framework is versatile, applicable across various sectors including aerospace, manufacturing, and energy systems, ultimately contributing to safer, more efficient operations in our increasingly complex technological landscape.

Diagnostics

Properties of a Ni19.5Pd30Ti50.5 High-Temperature Shape Memory Alloy in Tension and Compression

Potential applications involving high-temperature shape memory alloys have been growing in recent years. Even in those cases where promising new alloys have been identified, the knowledge base for such materials contains gaps crucial to their maturation and implementation in actuator and other applications. We begin to address this issue by characterizing the mechanical behavior of a Ni 19.5 Pd 30 Ti 50.5 high-temperature shape memory alloy in both uniaxial tension and compression at various temperatures. Differences in the isothermal uniaxial deformation behavior were most notable at test temperatures below the martensite finish temperature. The elastic modulus of the material was very dependent on strain level; therefore, dynamic Young’s Modulus was determined as a function of temperature by an impulse excitation technique. More importantly, the performance of a thermally activated actuator material is dependent on the work output of the alloy. Consequently, the strain-temperature response of the Ni 19.5 Pd 30 Ti 50.5 alloy under various loads was determined in both tension and compression and the specific work output calculated and compared in both loading conditions. It was found that the transformation strain and thus, the specific work output were similar regardless of the loading condition. Also, in both tension and compression, the strain-temperature loops determined under constant load conditions did not close due to the fact that the transformation strain during cooling was always larger than the transformation strain during heating. This was apparently the result of permanent plastic deformation of the martensite phase with each cycle. Consequently, before this alloy can be used under cyclic actuation conditions, modification of the microstructure or composition would be required to increase the resistance of the alloy to plastic deformation by slip.

High-Temperature Shape Memory Alloy

Spacecraft Water Impurity Monitor, a System for Water Quality Analysis on Exploration Missions Beyond Low Earth Orbit

Exploration missions beyond low-earth-orbit (LEO) will require advanced instrumentation to monitor water quality. Traveling beyond LEO means the transfer of water samples to an Earth-based laboratory for detailed analysis is not feasible. Detailed analysis of water composition during exploration is still necessary, because having the capability to determine the specific organic chemical causing a change in total organic carbon (TOC) or the specific metal or ionic species causing a change in conductivity has the potential to inform the crew health and system management decisions. On a new vehicle such as a lunar or Mars surface habitat or a Mars transit vehicle, finding “new” impurities not seen on ISS should be expected. The key is to identify the impurity so the correct action can be taken. On ISS we can measure TOC, conductivity, and other physical properties but do not have the capability for detailed analysis using vehicle instrumentation. This is acceptable because ISS can send samples down to Earth for further analysis and obtain the detailed composition. The Spacecraft Water Impurity Monitor (SWIM) will provide detailed water quality analysis for missions in which sample down mass is not available. SWIM is a system comprising organic and inorganic analysis modules. For organic chemicals, a gas chromatograph mass spectrometer (GCMS) detects and identifies organic impurities. For inorganic species, a capillary electrophoresis capacitively coupled contactless conductivity detection (CE-C4D) system as well as ion specific electrodes detect and identify metal ions and other inorganic salts / acids. The SWIM technology demonstration project has completed a System Requirements Review (SRR) to finalize detection requirements and is currently working to refine vehicle interface requirements for a future technology demonstration. The project also has begun preliminary flight design activities for the core analyzers in the instrument suite.

Water Monitoring

Laser Beam Welding Advancements for In-Space Servicing, Assembly, and Manufacturing

NASA is currently working to develop in-space servicing, assembly, and manufacturing (ISAM) capabilities for low Earth orbit and the lunar surface. One crucial technology for this effort is laser beam welding. Laser systems can perform joining, cleaning, cutting, and repair activities, which will enable the construction of large in-space structures that could not fit on a single launch vehicle, such as trusses for solar panels, radiators, or communications infrastructure. Multiple projects studying laser welding for space applications are currently underway at NASA Marshall Space Flight Center. One of these, the DIsk-Shaped Configurable and Modular vAcuum uNit (DISCMAN), is a compact vacuum chamber designed to support parameter development for laser welding in microgravity. It contains a rotating platen with weld samples made from aluminum, steel, and titanium, a high-power infrared laser, and integrated pumps for pulling vacuum inside the sample cartridge. The DISCMAN payload is planned to launch to the International Space Station, where welds will be performed under sustained microgravity inside the Bishop Airlock. Another effort underway at Marshall is the Lunar Assembly and Servicing by Autonomous Robotics (LASAR) initiative. This project uses a space-rated robotic arm equipped with a laser weld head, wire feeder, and multiple cameras to perform welds in a thermal vacuum chamber simulating the lunar surface environment. Some of these welds are done on snowflake joints, which are specially designed to slot together to join segments of trussN structures, allowing for the construction of tall surface infrastructure. DISCMAN, LASAR, and other projects are being carried out to advance the technological maturity of in-space laser beam welding, collect data to inform computational models, and learn reliable processes for creating weld joints in space. This work supports NASA’s greater goals to expand humanity’s presence in low Earth orbit, establish a permanent moon base, and eventually send crewed missions to Mars and beyond.

Robotics

Laser Beam Welding Advancements for In-Space Servicing, Assembly, and Manufacturing

NASA is currently working to develop in-space servicing, assembly, and manufacturing (ISAM) capabilities for low Earth orbit and the lunar surface. One crucial technology for this effort is laser beam welding. Laser systems can perform joining, cleaning, cutting, and repair activities, which will enable the construction of large in-space structures that could not fit on a single launch vehicle, such as trusses for solar panels, radiators, or communications infrastructure. Multiple projects studying laser welding for space applications are currently underway at NASA Marshall Space Flight Center. One of these, the DIsk-Shaped Configurable and Modular vAcuum uNit (DISCMAN), is a compact vacuum chamber designed to support parameter development for laser welding in microgravity. It contains a rotating platen with weld samples made from aluminum, steel, and titanium, a high-power infrared laser, and integrated pumps for pulling vacuum inside the sample cartridge. The DISCMAN payload is planned to launch to the International Space Station, where welds will be performed under sustained microgravity inside the Bishop Airlock. Another effort underway at Marshall is the Lunar Assembly and Servicing by Autonomous Robotics (LASAR) initiative. This project uses a space-rated robotic arm equipped with a laser weld head, wire feeder, and multiple cameras to perform welds in a thermal vacuum chamber simulating the lunar surface environment. Some of these welds are done on snowflake joints, which are specially designed to slot together to join segments of trussN structures, allowing for the construction of tall surface infrastructure. DISCMAN, LASAR, and other projects are being carried out to advance the technological maturity of in-space laser beam welding, collect data to inform computational models, and learn reliable processes for creating weld joints in space. This work supports NASA’s greater goals to expand humanity’s presence in low Earth orbit, establish a permanent moon base, and eventually send crewed missions to Mars and beyond.

Manufacturing

The Evolution of the Moon and the Terrestrial Planets

The thermal evolutions of the Moon, Mars, Venus, and Mercury are calculated theoretically starting from cosmochemical condensation models. An assortment of geological, geochemical, and geophysical data are used to constrain both the present-day temperatures and the thermal histories of the planets' interiors. Such data imply that the planets were heated during or shortly after formation and that all the terrestrial planets started their differentiations early in their history. Initial temperatures and core formation play the most important roles in the early differentiation. The size of the planet is the primary factor in determining its present-day thermal state. The Moon, smallest in size, is characterized as a differentiated body with a crust, a thick solid mantle, and an interior region which may be partially molten. It is presently cooling rapidly and is relatively inactive tectonically. Mercury, which probably has a large core, may have a 500-km-thick solid lithosphere and a partially molten core, if it is assumed that some heat sources exist in the core. If this is not the case, the planet's interior temperatures are everywhere below the melting curve for iron. The thermal evolution is dominated by the core separation and the high conductivity of iron that makes up the bulk of Mercury. Mars, intermediate in size, is assumed to have differentiated an Fe-FeS core. While the formation of an early crust is evident, large-scale melting and differentiation of the mantle silicates has occurred at least up until 1 b.y. ago. Present-day temperature profiles indicate moderate tectonic activity at the present time. Venus is characterized as a planet not unlike the Earth in many respects. Core formation has occurred probably during the first billion years after the formation. The present-day temperatures indicate a partially molten upper mantle overlain by a 100-km-thick lithosphere and a molten Fe-Ni core. We can expect that today Venus may have tectonic processes similar to the Earth's.

M Nafi Toksöz

Spacecraft Water Impurity Monitor, a System for Water Quality Analysis on Exploration Missions Beyond Low Earth Orbit

Exploration missions beyond low-earth-orbit (LEO) will require advanced instrumentation to monitor water quality. Traveling beyond LEO means the transfer of water samples to an Earth-based laboratory for detailed analysis is not feasible. Detailed analysis of water composition during exploration is still necessary, because having the capability to determine the specific organic chemical causing a change in total organic carbon (TOC) or the specific metal or ionic species causing a change in conductivity has the potential to inform the crew health and system management decisions. On a new vehicle such as a lunar or Mars surface habitat or a Mars transit vehicle, finding “new” impurities not seen on ISS should be expected. The key is to identify the impurity so the correct action can be taken. On ISS we can measure TOC, conductivity, and other physical properties but do not have the capability for detailed analysis using vehicle instrumentation. This is acceptable because ISS can send samples down to Earth for further analysis and obtain the detailed composition. The Spacecraft Water Impurity Monitor (SWIM) will provide detailed water quality analysis for missions in which sample down mass is not available. SWIM is a system comprising organic and inorganic analysis modules. For organic chemicals, a gas chromatograph mass spectrometer (GCMS) detects and identifies organic impurities. For inorganic species, a capillary electrophoresis capacitively coupled contactless conductivity detection (CE-C4D) system as well as ion specific electrodes detect and identify metal ions and other inorganic salts / acids. The SWIM technology demonstration project has completed a System Requirements Review (SRR) to finalize detection requirements and is currently working to refine vehicle interface requirements for a future technology demonstration. The project also has begun preliminary flight design activities for the core analyzers in the instrument suite.

Water Monitoring

A Modular Conjugate Heat Transfer Optimization Framework for Thermal Management of Electric Aircraft

Conjugate heat transfer (CHT) analysis and optimization is a powerful method for improving thermal management, as it simultaneously resolves the temperature distribution in both fluid and solid domains. This paper presents a modular, discrete adjoint-based CHT optimization capability integrated within the OpenMDAO/MPhys framework. A unique feature of the proposed framework is its flexibility to extend to multidisciplinary optimization, including aero-structural-thermal applications. The fluid domain is modeled using a finite-volume Computational Fluid Dynamics (CFD) solver, and the solid domain with a conduction heat transfer solver. A mixed Neumann-Dirichlet boundary condition is developed to enable full submersion of the solid geometry within the fluid domain, while ensuring consistent temperature and heat flux coupling at the CHT interface. Gradient-based optimization is performed; the gradients are efficiently computed using the discrete adjoint solvers implemented in DAFoam. To demonstrate the method, this paper considers two cases related to electric aircraft thermal management: a U-bend heat exchanger and an actively cooled battery pack. The U-bend case aims to minimize pressure loss while maximizing heat flux by changing the pipe geometry. The optimized design reduces pressure loss by 52.7% and increases total heat flux by 2.3%. In the battery pack case, a 3-by-3 cell configuration is cooled by ambient airflow, with constant heat generation prescribed in the cells. The battery casing shape serves as the design variable, and the objective function is a weighted sum of pressure loss and pack weight, subject to a maximum temperature constraint. The optimized design achieves a 44.6% reduction in pressure loss and a 1.5% reduction in weight, while satisfying the thermal constraint. To ensure the reliability of the optimized designs, this study validates coarse-mesh, steady-state predictions against fine-mesh unsteady simulations, demonstrating consistency within acceptable errors. This work demonstrates the potential of the developed framework to enable rapid, high-fidelity design of thermal management systems for electric aircraft.

heat transfer

Scientific Highlights and Status of the Mars Science Laboratory Mission, Years 9 through 12

We present the scientific highlights and status from years 9-12 of NASA’s Mars Science Laboratory mission, with its Curiosity rover. A thermochemolysis-based sample analysis revealed a variety of organic molecules preserved in clay mineral-rich lake/lake margin deposits of the Glen Torridon region. The stratigraphically higher clay-sulfate mineral transition on Aeolis Mons was found to be associated with a lithological change from lacustrine to dry aeolian depositional environments. Water intermittently returned to the surface after the increase in aridity, including during the deposition of wave ripple strata which indicate a climate capable of sustaining an ice-free lake in the early Hesperian. The overlying Mg sulfate-bearing unit has both poly- and monohydrated Mg sulfates and is also enriched in iron carbonate of a purity consistent with chemical sedimentation and therefore atmospheric sequestration. A channel-incised canyon within Gediz Vallis and distal alluvial deposits recorded numerous fluvial and debris flow events after the deposition, lithification, and erosion of the clay- and sulfate-bearing units. Bright clasts found in Gediz Vallis canyon are composed of native sulfur. The investigation of the modern atmosphere and environment focused on the influence of the crater and mountain topography and captured high-altitude noctilucent and iridescent clouds. Radiation monitoring now spans an 11-year solar cycle. Rover systems and science instruments remain capable of addressing mission scientific objectives. All ten scientific instruments continue to return high-value data despite degradation of the Chemistry and Camera instrument’s high-voltage system, loss of multispectral imaging capability, and loss of active neutron spectroscopy. The mission has mitigated the loss of redundant brakes on two arm joints, additional wheel wear, and highly reduced capability of the redundant flight computer. Efficiency improvements in rover energy utilization and operations staffing have allowed the mission team to maintain a high level of productivity despite declining rover power generation and funding.

Mars

High Temperature - Thin Film Strain Gages Based on Alloys of Indium Tin Oxide

A stable, high temperature strain gage based on reactively sputtered indium tin oxide (ITO) was demonstrated at temperatures up to 1050 C. These strain sensors exhibited relatively large, negative gage factors at room temperature and their piezoresistive response was both linear and reproducible when strained up to 700 micro-in/in. When cycled between compression and tension, these sensors also showed very little hysteresis, indicating excellent mechanical stability. Thin film strain gages based on selected ITO alloys withstood more than 50,000 strain cycles of +/- 500 micro-in/in during 180 hours of testing in air at 1000 C, with minimal drift at temperature. Drift rates as low as 0.0009%/hr at 1000 C were observed for ITO films that were annealed in nitrogen at 700 C prior to strain testing. These results compare favorably with state of the art 10 micro-m thick PdCr films deposited by NASA, where drift rates of 0.047%/hr at 1050 C were observed. Nitrogen annealing not only produced the lowest drift rates to date, but also produce the largest dynamic gage factors (G = 23.5). These wide bandgap, semiconductor strain sensors also exhibited moderately low temperature coefficients of resistance (TCR) at temperatures up to 1100 C, when tested in a nitrogen ambient. A TCR of +230 ppm/C over the temperature range 200 C < T < 500 C and a TCR of -469 ppm/C over the temperature range 600 C < T < 1100 C was observed for the films tested in nitrogen. However, the resistivity behavior changed considerably when the same films were tested in oxygen ambients. A TCR of -1560 ppm/C was obtained over the temperature range of 200 C < T < 1100 C. When similar films were protected with an overcoat or when ITO films were prepared with higher oxygen contents in the plasma, two distinct TCR's were observed. At T < 800 C, a linear TCR of -210 ppm/C was observed and at T > 800 C, a linear TCR of -2170 DDm/C was observed. The combination of a moderately low TCR and a relatively large gage factor make these semiconducting oxide films promising candidates for the active strain elements in high temperature thin film strain gages, particularly in applications where static strain measurement is desired.

Otto J Gregory

Final Report Document: Microgravity Medical Eyewash B

Senior Capstone Design Team 15 has been commissioned by the National Aeronautics and Space Administration (NASA) to redesign the current microgravity eye wash station. The current design exhibits four primary limitations: single-use operation, excessive mass and volume, operational complexity requiring coordination with external systems, and dependence on frequent Earth resupply missions. Our updated eyewash design will be deployed on long-range space missions that could last multiple years. Based on these and other requirements from our customer, we have developed our updated eyewash design. Our compact, single-eye system uses capillary-driven flow and a free-floating water ball. This design allows us to eliminate pumps and bulky tubing, decreasing the mass and volume of the overall system. The containment eyecup is held to the astronaut's face with a strap, and a silicone seal prevents leakage while improving user comfort. Contaminated water is contained within a disposal bag containing wicking material to pull it back out of the eyecup after washing the eye. This system is reusable, efficient, and easy to activate quickly. We evaluated our design through calculations, microfluidic testing, and user try-on testing to verify our requirements. Our work demonstrated that steady-state flow was capable with our capillary framework, achieving 1.31 L/min. The prototype construction confirmed mass and volume reductions, and try-on-testing evaluated the ability to put on the system quickly. Almost all major design requirements were achieved, and water loss could be validated by testing in microgravity. Our design went through a number of iterations to reach the final solution presented in this report. These changes were driven by our testing and collaboration from each member of the team. Updated models optimized tube placement and geometry of the eyecup to better direct flow as it pools across the eye. Changes to our tubing bends improved capillary efficiency and increased the flow rate we were capable of achieving. And improved bracket placements adjusted the fit, comfort, and seal of the eyecup to the astronaut's face. Our capillary-based eyewash system is technically feasible and has been theoretically validated to operate effectively in microgravity conditions. Testing and analysis indicate that it can meet or exceed the required performance metrics, including flow rate and safety constraints. Overall, the design represents a viable alternative to current ISS-dependent eyewash systems for future space missions.

Jeffrey Allen

Lunar Elemental Analysis Obtained From the Apollo Gamma-Ray and X-Ray Remote Sensing Experiment

Gamma-ray and X-ray spectrometers carried in the Service Modules of the Apollo 15 and Apollo 16 spacecraft were employed for compositional mapping of the lunar surface. The measurements involved the observation of the intensity and characteristic energy distribution of gamma rays and X-rays emitted from the lunar surface. A large-scale compositional map of over 10 percent of the lunar surface was obtained from an analysis of the observed spectra. The Apollo 15 flight was at a lunar orbital inclination of 29 degrees as compared with a 9-degree inclination of the Apollo 16 flight; thus, the projected ground track of the Apollo 15 flight covered a larger projected surface area than that of the Apollo 16 flight. The objective of the X-ray experiment was to measure the K spectral lines from Mg, Al, and Si. Spectra were obtained and the data were reduced to Al/Si and Mg/Si intensity ratios and ultimately to chemical ratios. Analyses of the results have indicated (1) that the Al/Si ratios are highest in the lunar highlands and considerably lower in the maria, and (2) that the Mg/Si concentrations generally show the opposite relationship. There is a tendency for the Al/Si values to increase from the western mare areas to the eastern limb highlands. There are distinct chemical contrasts between such features: as the small mare basins and the highland rims. The objective of the gamma-ray experiment was to measure the natural and cosmic-ray-induced activity emission spectrum. At this time, the elemental abundances for Th, U, K, Fe, Ti, Si, and O have been determined over a number of major lunar regions. Regions of relatively high natural radioactivity were found in the Mare Imbrium and Oceanus Procellarum regions. High spots of natural radioactivity were also found south of Fra Mauro; somewhat southwest of Archimedes, and south of Aristarchus. An enhanced region of natural radioactivity was found around Van de Graaff on the far side of tile Moon. In regions other than Mare Imbrium and Oceanus Procellarum, an anticorrelation between natural radioactivity and lunar elevation, as determined from the Apollo laser, altimeter, has been found. From the combined results of the gamma-ray and X-ray spectrometer experiments almost complete information concerning the major element composition of over 10 percent of the lunar surface has been obtained. Distributions have also been mapped for K, Th, and Ti. Interesting correlations between lunar topography and magnetic and gravitational properties have been found.

J I Trombka

Modular Battery Charge Controller

A new approach to masterless, distributed, digital-charge control for batteries requiring charge control has been developed and implemented. This approach is required in battery chemistries that need cell-level charge control for safety and is characterized by the use of one controller per cell, resulting in redundant sensors for critical components, such as voltage, temperature, and current. The charge controllers in a given battery interact in a masterless fashion for the purpose of cell balancing, charge control, and state-of-charge estimation. This makes the battery system invariably fault-tolerant. The solution to the single-fault failure, due to the use of a single charge controller (CC), was solved by implementing one CC per cell and linking them via an isolated communication bus [e.g., controller area network (CAN)] in a masterless fashion so that the failure of one or more CCs will not impact the remaining functional CCs. Each micro-controller-based CC digitizes the cell voltage (V(sub cell)), two cell temperatures, and the voltage across the switch (V); the latter variable is used in conjunction with V(sub cell) to estimate the bypass current for a given bypass resistor. Furthermore, CC1 digitizes the battery current (I1) and battery voltage (V(sub batt) and CC5 digitizes a second battery current (I2). As a result, redundant readings are taken for temperature, battery current, and battery voltage through the summation of the individual cell voltages given that each CC knows the voltage of the other cells. For the purpose of cell balancing, each CC periodically and independently transmits its cell voltage and stores the received cell voltage of the other cells in an array. The position in the array depends on the identifier (ID) of the transmitting CC. After eight cell voltage receptions, the array is checked to see if one or more cells did not transmit. If one or more transmissions are missing, the missing cell(s) is (are) eliminated from cell-balancing calculations. The cell-balancing algorithm is based on the error between the cell s voltage and the other cells and is categorized into four zones of operation. The algorithm is executed every second and, if cell balancing is activated, the error variable is set to a negative low value. The largest error between the cell and the other cells is found and the zone of operation determined. If the error is zero or negative, then the cell is at the lowest voltage and no balancing action is needed. If the error is less than a predetermined negative value, a Cell Bad Flag is set. If the error is positive, then cell balancing is needed, but a hysteretic zone is added to prevent the bypass circuit from triggering repeatedly near zero error. This approach keeps the cells within a predetermined voltage range.

Button, Robert