Search NASA⌕ Search

SEARCH · Search NASA

Results for “actuation devices”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Control of a flexible planar truss using proof mass actuators

A flexible structure was modeled and actively controlled by using a single space realizable linear proof mass actuator. The NASA/UVA/UB actuator was attached to a flexible planar truss structure at an optimal location and it was considered as both passive and active device. The placement of the actuator was specified by examining the eigenvalues of the modified model that included the actuator dynamics, and the frequency response functions of the modified system. The electronic stiffness of the actuator was specified, such that the proof mass actuator system was tuned to the fourth structural mode of the truss by using traditional vibration absorber design. The active control law was limited to velocity feedback by integrating of the signals of two accelerometers attached to the structure. The two lower modes of the closed-loop structure were placed further in the LHS of the complex plane. The theoretically predicted passive and active control law was experimentally verified.

Minas, Constantinos↗

Optimal control of systems with capacity: Related noises

In the ordinary theory of optimal control (LQR and Kalman filter), the variances of the actuators and the sensors are assumed to be known (not related to the capacities of the devices). This assumption is not true in practice. Generally, a device with greater capacity to exert actuating forces and a sensor capable of sensing greater sensing range will generate noise of greater power spectral density. When the ordinary theory of optimal control is used to estimate the errors of the outputs in such cases it will lead to faulty results, because the capacities of such devices are unknown before the system is designed. The performance of the system designed by the ordinary theory will not be optimal as the variances of the sensors and the actuators are neither known nor constant. The interaction between the control system and structure could be serious because the ordinary method will lead to greater feedback (Kalman gain) matrices. Methods which can optimize the performance of systems when noises of the actuators and the sensors are related to their capacities are developed. These methods will result in smaller feedback (Kalman gain) matrix.

Ruan, Milfang↗

Fast Electromechanical Switches Based on Carbon Nanotubes

Electrostatically actuated nanoelectromechanical switches based on carbon nanotubes have been fabricated and tested in a continuing effort to develop high-speed switches for a variety of stationary and portable electronic equipment. As explained below, these devices offer advantages over electrostatically actuated microelectromechanical switches, which, heretofore, have represented the state of the art of rapid, highly miniaturized electromechanical switches. Potential applications for these devices include computer memories, cellular telephones, communication networks, scientific instrumentation, and general radiation-hard electronic equipment. A representative device of the present type includes a single-wall carbon nanotube suspended over a trench about 130 nm wide and 20 nm deep in an electrically insulating material. The ends of the carbon nanotube are connected to metal electrodes, denoted the source and drain electrodes. At bottom of the trench is another metal electrode, denoted the pull electrode (see figure). In the off or open switch state, no voltage is applied, and the nanotube remains out of contact with the pull electrode. When a sufficiently large electric potential (switching potential) is applied between the pull electrode and either or both of the source and drain electrodes, the resulting electrostatic attraction bends and stretches the nanotube into contact with the pull electrode, thereby putting the switch into the "on" or "closed" state, in which substantial current (typically as much as hundreds of nanoamperes) is conducted. Devices of this type for use in initial experiments were fabricated on a thermally oxidized Si wafer, onto which Nb was sputter-deposited for use as the pull-electrode layer. Nb was chosen because its refractory nature would enable it to withstand the chemical and thermal conditions to be subsequently imposed for growing carbon nanotubes. A 200- nm-thick layer of SiO2 was formed on top of the Nb layer by plasma-enhanced chemical vapor deposition. In the device regions, the SiO2 layer was patterned to thin it to the 20-nm trench depth. The trenches were then patterned by electron- beam lithography and formed by reactive- ion etching of the pattern through the 20-nm-thick SiO2 to the Nb layer.

Kaul, Anupama↗

Anisotropic Laminar Piezocomposite Actuator Incorporating Machined PMN-PT Single Crystal Fibers

The design, fabrication, and testing of a flexible, laminar, anisotropic piezoelectric composite actuator utilizing machined PMN-32%PT single crystal fibers is presented. The device consists of a layer of rectangular single crystal piezoelectric fibers in an epoxy matrix, packaged between interdigitated electrode polyimide films. Quasistatic free-strain measurements of the single crystal device are compared with measurements from geometrically identical specimens incorporating polycrystalline PZT-5A and PZT-5H piezoceramic fibers. Free-strain actuation of the single crystal actuator at low bipolar electric fields (+/- 250 V/mm) is approximately 400% greater than that of the baseline PZT-5A piezoceramic device, and 200% greater than that of the PZT-5H device. Free-strain actuation under high unipolar electric fields (0-4kV/mm) is approximately 200% of the PZT-5A baseline device, and 150% of the PZT-5H alternate piezoceramic device. Performance increases at low field are qualitatively consistent with predicted increases based on scaling the low-field d33 piezoelectric constants of the respective piezoelectric materials. High-field increases are much less than scaled d33 estimates, but appear consistent with high-field freestrain measurements reported for similar bulk single-crystal and piezoceramic compositions. Measurements of single crystal actuator capacitance and coupling coefficient are also provided. These properties were poorly predicted using scaled bulk material dielectric and coupling coefficient data. Rules-of-mixtures calculations of the effective elastic properties of the single crystal device and estimated actuation work energy densities are also presented. Results indicate longitudinal stiffnesses significantly lower (50% less) than either piezoceramic device. This suggests that single-crystal piezocomposite actuators will be best suited to low induced-stress, high strain and deflection applications.

Wilkie, W. Keats↗

Anisotropic Piezocomposite Actuator Incorporating Machined PMN-PT Single Crystal Fibers

The design, fabrication, and testing of a flexible, planar, anisotropic piezoelectric composite actuator utilizing machined PMN-32%PT single crystal fibers is presented. The device consists of a layer of rectangular single crystal piezoelectric fibers in an epoxy matrix, packaged between interdigitated electrode polyimide films. Quasistatic free-strain measurements of the single crystal device are compared with measurements from geometrically identical specimens incorporating polycrystalline PZT-5A and PZT-5H piezoceramic fibers. Free-strain actuation of the single crystal actuator at low bipolar electric fields (+/- 250 V/mm) is approximately 400% greater than that of the baseline PZT-5A piezoceramic device, and 200% greater than that of the PZT-5H device. Free-strain actuation under high unipolar electric fields (0-4kV/mm) is approximately 200% of the PZT-5A baseline device, and 150% of the PZT-5H alternate piezoceramic device. Performance increases at low field are qualitatively consistent with predicted increases based on scaling the low-field d(sub 33) piezoelectric constants of the respective piezoelectric materials. High-field increases are much less than scaled d(sub 33) estimates, but appear consistent with high-field freestrain measurements reported for similar bulk single-crystal and piezoceramic compositions. Measurements of single crystal actuator capacitance and coupling coefficient are also provided. These properties were poorly predicted using scaled bulk material dielectric and coupling coefficient data. Rules-of-mixtures calculations of the effective elastic properties of the single crystal device and estimated actuation work energy densities are also presented. Results indicate longitudinal stiffnesses significantly lower (50% less) than either piezoceramic device. This suggests that single-crystal piezocomposite actuators will be best suited to low induced-stress, high strain and deflection applications.

Wilkie, W. Keats↗

Solar vane actuator Patent

Design and characteristics of device for sensing solar radiation and providing spacecraft attitude control to maintain direction with respect to incident radiation

Acord, J. D.↗

Rotationally actuated prosthetic helping hand

A prosthetic device has been developed for below-the-elbow amputees. The device consists of a cuff, a stem, a housing, two hook-like fingers, an elastic band for holding the fingers together, and a brace. The fingers are pivotally mounted on a housing that is secured to the amputee's upper arm with the brace. The stem, which also contains a cam, is rotationally mounted within the housing and is secured to the cuff, which fits over the amputee's stump. By rotating the cammed stem between the fingers with the lower arm, the amputee can open and close the fingers.

Norton, William E.↗

Methods and Apparatus for Pulsed-DC Dielectric Barrier Discharge Plasma Actuator and Circuit

A plasma generating device intended to induce a flow in a fluid via plasma generation includes a dielectric separating two electrodes and a power supply. The first electrode is exposed to a fluid flow while the second electrode is positioned under the dielectric. The power supply is electrically coupled to a switch and the first and second electrodes. When the power supply is energized by repeated action of the switch, it causes a pulsed DC current between the electrodes which causes the fluid to ionize generating a plasma. The generation of the plasma induces a force with a velocity component in the fluid.

Corke, Thomas C.↗

Electro-Active Transducer Using Radial Electric Field To Produce/Motion Sense Out-Of-Plane Transducer

An electro-active transducer includes a ferroelectric material sandwiched by first and second electrode patterns. When the device is used as an actuator, the first and second electrode patterns are configured to introduce an electric field into the ferroelectric material when voltage is applied to the electrode patterns. When the device is used as a sensor. the first and second electrode patterns are configured to introduce an electric field into the ferroelectric material when the ferroelectric material experiences deflection in a direction substantially perpendicular thereto. In each case, the electrode patterns are designed to cause the electric field to: i) originate at a region of the ferroelectric material between the first and second electrode patterns. and ii) extend radially outward from the region of the ferroelectric material (at which the electric field originates) and substantially parallel to the ferroelectric material s plane.

Bryant, Robert G.↗

Magnetostrictive direct drive motor

Highly magnetostrictive materials such as Tb.3Dy.7Fe2, commercially known as TERFENOL-D, have been used to date in a variety of devices such as high power actuators and linear motors. The larger magnetostriction available in twinned single crystal TERFENOL-D, approx. 2000 ppm at moderate magnetic field strengths, makes possible a new generation of magnetomechanical devices. NASA researchers are studying the potential of this material as the basis for a direct microstepping rotary motor with torque densities on the order of industrial hydraulics and five times greater than that of the most efficient, high power electric motors. Such a motor would be a micro-radian stepper, capable of precision movements and self-braking in the power-off state. Innovative mechanical engineering techniques are juxtaposed on proper magnetic circuit design to reduce losses in structural flexures, inertias, thermal expansions, eddy currents, and magneto-mechanical coupling, thus optimizing motor performance and efficiency. Mathematical models are presented, including magnetic, structural, and both linear and nonlinear dynamic calculations and simulations. In addition, test results on prototypes are presented.

Naik, Dipak↗

Development of shape memory metal as the actuator of a fail safe mechanism

A small, compact, lightweight device was developed using shape memory alloy (SMA) in wire form to actuate a pin-puller that decouples the flanges of two shafts. When the SMA is heated it contracts producing a useful force and stroke. As it cools, it can be reset (elongated in this case) by applying a relatively small force. Resistive heating is accomplished by running a current through the SMA wire for a controlled length of time. The electronics to drive the device are not elaborate or complicated, consisting of a timed current source. The total available contraction is 3 percent of the length of the wire. This device, the engineering properties of the SMA, and the tests performed to verify the design concept are described.

Ford, V. G.↗

Improvements to the Tendon-Actuated Lightweight In-Space MANipulator (TALISMAN)

Devices for manipulating and precisely placing payloads are critical for efficient space operations including berthing of spacecraft, in-space assembly, construction and repair. Key to the success of many NASA space activities has been the availability of long-reach crane-like devices such as the Shuttle Remote Manipulation System (SRMS) and the Space Station Remote Manipulation System (SSRMS). These devices have been used for many operations including berthing visiting spacecraft to the International Space Station, deployment of spacecraft, space station assembly, astronaut positioning, payload transfer, and spacecraft inspection prior to atmospheric re-entry. Retiring the Space Transportation System has led to the removal of the SRMS from consideration for in-space missions, thus creating a capability gap. Recognizing this gap, work was initiated at NASA on a new architecture for long-reach space manipulators. Most current devices are constructed by joining revolute joints with carbon composite tubes, with the joints accounting for the majority of the device mass. For example in the case of the SRMS, the entire device mass is 410 kg (904 lbm); the joint structure, motors, gear train, cabling, etc., accounts for the majority of the system mass because the carbon composite tubes mass is 46 kg (101 lbm). An alternate space manipulator concept, the Tendon-Actuated Lightweight In-Space MANipulator (TALISMAN) was created to address deficiencies in the current state-of-the-art in long-reach manipulators. The antagonistic tendon actuated joint architecture allows the motors actuating the joint to be removed from the joint axis, which simplifies the joint design while simultaneously providing mechanical advantage for the motors. The improved mechanical advantage, in turn, reduces the size and power requirements for the motor and gear train. This paper will describe recent architectural improvements to the TALISMAN design that: 1) improve the operational robustness of the system by enabling maneuvers not originally possible by varying the TALISMAN geometry; 2) enable efficient active antagonistic control of a joint while sharing cable between antagonistic tension networks; and 3) uses a unique arrangement of differential capstans to reduce motor torque requirements by an order of magnitude. The paper will also summarize recent efforts to enable autonomous deployment of a TALISMAN including the deployment concept of operations and associated hardware system design. The deployment forces are provided by the same motor systems that are used for articulation, thus reducing the mass associated with the deployment system. The deployment approach is being tested on a TALISMAN prototype which is designed to provide the same operational performance as a shuttle-class manipulator. The prototype has been fabricated and is operational in a new facility at NASA Langley Research Center that has a large area (15.2 m by 21.3 m [50 ft by 70 ft]) air-bearing floor.

Doggett, William R.↗

Miniature Piezoelectric Shaker Mechanism for Autonomous Distribution of Unconsolidated Sample to Instrument Cells

To perform in-situ measurements on Mars or other planetary bodies many instruments require powder produced using some sampling technique (drilling/coring) or sample processing technique (core crushing) to be placed in measurement cells. This usually requires filling a small sample cell using an inlet funnel. In order to minimize cross contamination with future samples and ensure the sample is transferred from the funnel to the test cell with minimal residual powder the funnel is shaken. The shaking assists gravity by fluidizing the powder and restoring flow of the material. In order to counter cross contamination or potential clogging due to settling during autonomous handling a piezoelectric shaking mechanism was designed for the deposition of sample fines in instrument inlet funnels. This device was designed to be lightweight, consume low power and demonstrated to be a resilient solid state actuator that can be mechanically and electrically tuned to shake the inlet funnel. In the final design configuration tested under nominal Mars Ambient conditions the funnel mechanism is driven by three symmetrically mounted piezoelectric flexure actuators that are out of the funnel support load path. The frequency of the actuation can be electrically controlled and monitored and mechanically tuned by the addition of tuning mass on the free end of the actuator. Unlike conventional electromagnetic motors these devices are solid state and can be designed with no macroscopically moving parts. This paper will discuss the design and testing results of these shaking mechanisms.

powder movement↗

Preloaded latching device

A latching device is disclosed which is lever operated sequentially to actuate a set of collet fingers to provide a radial expansion and to actuate a force mechanism to provide a compressive gripping force for attaching first and second devices to one another. The latching device includes a body member having elongated collet fingers which, in a deactuated condition, is insertable through bores on the first and second devices so that gripping terminal portions on the collet fingers are proximate to the end of the bore of the first device while a spring assembly on the body member is located proximate to the outer surface of a second device. A lever is rotatable through 90 deg to move a latching rod to sequentially actuate and expand collet fingers and to actuate the spring assembly by compressing it. During the first 30 deg of movement of the lever, the collet fingers are actuated by the latching rod to provide a radial expansion and during the last 60 deg of movement of the lever, the spring assembly acts as a force mechanism and is actuated to develop a compressive latching force on the devices. The latching rod and lever are connected by a camming mechanism. The amount of spring force in the spring assembly can be adjusted; the body member can be permanently attached by a telescoping assembly to one of the devices; and the structure can be used as a pulling device for removing annular bearings or the like from blind bores.

Wesselski, Clarence J.↗

Combined actuator and latch for cartridge powered actuator

Combined attenuator and latch stops and latches in place a given mass which is to be moved a discrete distance to effect a desired condition. This device is used in a retraction actuator driven by a pyrotechnic thruster, and can be tailored to meet specific design requirements.

Murphy, D. W.↗

Generating Real-Time Robotics Control Software from SysML

In this paper, we outline an approach for autogenerating real-time robotics control code from hierarchical state machines and hardware configurations encoded in Systems Modeling Language (SysML). We propose a software architecture that provides an abstract SysML layer with access to device state information and a set of primitive device commands, such as move actuator and release brake, allowing a user to build up a complete functional state machine directly in SysML. The SysML diagram is then exported to a standard SCXML file format and subsequently used to auto-generate hardware control code. Once this architecture is in place, the only explicit code elements that need to be written are the primitive device commands, which can be easily unit tested and reused across different systems. The motivation for this work was the need for a test bed that enables the rapid prototyping of mechanisms and control algorithms for a spacecraft that could ultimately be used for preparing Martian rock samples for their return to Earth. To this end, our software system was also designed to allow for the run-time specification of the hardware layout in SysML, with the hardware-level control functions kept agnostic to the specific parameters or communication bus of any particular device. Further, we outline a system for specifying both the state machine and hardware configuration in the MagicDraw IDE in such a way that the system can be simulated before any code is generated. The resultant software system is easy to debug, understand, and allows users to choose how much information is encoded as a visual or text-based representation.

Godart, Peter↗

High-Fidelity Piezoelectric Audio Device

ModalMax is a very innovative means of harnessing the vibration of a piezoelectric actuator to produce an energy efficient low-profile device with high-bandwidth high-fidelity audio response. The piezoelectric audio device outperforms many commercially available speakers made using speaker cones. The piezoelectric device weighs substantially less (4 g) than the speaker cones which use magnets (10 g). ModalMax devices have extreme fabrication simplicity. The entire audio device is fabricated by lamination. The simplicity of the design lends itself to lower cost. The piezoelectric audio device can be used without its acoustic chambers and thereby resulting in a very low thickness of 0.023 in. (0.58 mm). The piezoelectric audio device can be completely encapsulated, which makes it very attractive for use in wet environments. Encapsulation does not significantly alter the audio response. Its small size (see Figure 1) is applicable to many consumer electronic products, such as pagers, portable radios, headphones, laptop computers, computer monitors, toys, and electronic games. The audio device can also be used in automobile or aircraft sound systems.

Woodward, Stanley E.↗

NASA Tech Briefs, November 1995

The contents include: 1) Mission Accomplished; 2) Resource Report: Marshall Space Flight Center; 3) NASA 1995 Software of the Year Award; 4) Microbolometers Based on Epitaxial YBa2Cu3O(sub 7-x) Thin Films; 5) Garnet Random-Access Memory; 6) Fabrication of SNS Weak Links on SOS Substrates; 7) High-Voltage MOSFET Switching Circuit; 8) Asymmetric Switching for a PWM H-Bridge Power Circuit; 9) Better Ohmic Contacts for InP Semiconductor Devices; 10) Low-Bandgap Thermovoltaic Materials and Devices; 11) Digital Frequency-Differencing Circuit; 12) Imaging Magnetometer; 13) Computer-Assisted Monitoring of a Complex System; 14) Buffered Telemetry Demodulator; 15) Compact Multifunction Inspection Head; 16) Optical Detection of Fractures in Ceramic Diaphragms; 17) Eddy-Current Detection of Cracks in Reinforced Carbon/Carbon; 18) Apparent Thermal Conductivity of Multilayer Insulation; 19) Optimizing Misch-Metal Compositions in Metal Hydride Anodes; 20) Device for Sampling Surface Contamination; 21) Probabilistic Failure Assessment for Fatigue; 22) Probabilistic Fatigue and Flaw-Propagation Analysis; 23) Windows Program for Driving the TDU-850 Printer; 24) Subband/Transform MATLAB Functions for Processing Images; 25) Computing Equilibrium Chemical Compositions; 26) Program Processes Thermocouple Readings; 27) ICAN-Second-Generation Integrated Composite Analyzer; 28) Integrated Composite Analyzer with Damping Capabilities; 29) Computing Efficiency of Transfer of Microwave Power; 30) Program Calculates Power Demands of Electronic Designs; 31) Cost-Estimation Program; 32) Program Estimates Areas Required by Electronic Designs; 33) Program to Balance Mapped Turbopump Assemblies; 34) BiblioTech; 35) Controlling Mirror Tilt With a Bimorph Actuator; 36) Burst-Disk Device Simulates Effect of Pyrotechnic Device; 37) Bearing-Mounting Concept Accommodates Thermal Expansion; 38) Parallel-Plate Acoustic Absorbers for Hot Environments; 39) Adjustable-Length Strut Withstands Large Cyclic Loads; 40) Tool Indicates Contact Angles in Bearing Raceways; 41) Gravity Slides With Magnetic Braking; 42) High-Torque, Lightweight, Pneumatically Driven Wrench for Small Spaces; 43) Device for Testing Compatibility of an O-Ring; 44) Magnetic Heat Pump Containing Flow Diverters; 45) Variable-Tilt Helicopter Rotor Mast; 46) "Beach-Ball" Robotic Rovers; 47) Apparatus Would Measure Temperatures of Ball Bearings; 48) Flexible Borescope for Inspecting Ducts; 49) Texturing Copper To Reduce Secondary Emission of Electrons; 50) Automated Laser Cutting in Three Dimensions; 51) Algorithm Helps Monitor Engine Operation; 52) Flexible Revision of Data-Processing Communications; 53) Software for Managing the Use of Land; 54) Thermal Strap Increases Cryocooling Efficiency; 55) Reversible Nut With Engagement Indication; 56) Control Algorithms for Kinematically Redundant Manipulators; 57) Computed Hydrogen-Flow Splits in a Rocket Engine; 58) Pressure and Thermal Modeling of Rocket Launches; 59) Field of View of a Spacecraft Antenna: Analysis and Software; 60) Digital Controller for Laser-Beam-Steering Subsystem; 61) More About Beam-Steering Subsystem for Laser Communication; 62) Digital Controller for Laser-Beam-Steering Subsystem: Part 2; 63) Interface Circuit Board for Space-Shuttle Communications; 64) Automated Planning of Spacecraft Telecommunications; 65) Artifacts of Spectral Analysis of Instrument Readings; 66) Neural-Network Controller for Vibration Suppression; 67) Adaptive Finite-Element Computation in Fracture Mechanics; 68) Attitude Control for the Cassini Spacecraft; 69) Analytical Model for Fluid Dynamics in a Microgravity Environment; 70) Study of Rocket-Engine Joints Bonded by NVCU/NARloy-Z; 71) Improved Silicon Nitride for Advanced Heat Engines; 72) Parameters for Welding Aluminum/Lithium Alloys; 73) Lightweight Composite Intertank Structure; 74) Foil Patches Seal Small Vacuum Leaks; 75) Data Base on Cables and Connectors; 76) Effect of Clock Mode on Radiation Hardnessf an ADC; and 77) Fault-Tolerant Control for a Robotic Inspection System.

Source record↗