At least 253 records · Page 14

Dosimetry protocol for the forthcoming clinical trials in synchrotron stereotactic radiation therapy (SSRT)

Purpose: An adequate dosimetry protocol for synchrotron radiation and the specific features of the ID17 Biomedical Beamline at the European Synchrotron Radiation Facility are essential for the preparation of the forthcoming clinical trials in the synchrotron stereotactic radiation therapy (SSRT). The main aim of this work is the definition of a suitable protocol based on standards of dose absorbed to water. It must allow measuring the absolute dose with an uncertainty within the recommended limits for patient treatment of 2%-5%. Methods: Absolute dosimetry is performed with a thimble ionization chamber (PTW semiflex 31002) whose center is positioned at 2 g cm{sup -2} equivalent depth in water. Since the available synchrotron beam at the ESRF Biomedical Beamline has a maximum height of 3 mm, a scanning method was employed to mimic a uniform exposition of the ionization chamber. The scanning method has been shown to be equivalent to a broad beam irradiation. Different correction factors have been assessed by using Monte Carlo simulations. Results: The absolute dose absorbed to water at 80 keV was measured in reference conditions with a 2% global uncertainty, within the recommended limits. The dose rate was determined to be in the range between 14 and 18 Gy/min, that is to say, a factor two to three times higher than the 6 Gy/min achievable in RapidArc or VMAT machines. The dose absorbed to water was also measured in a RW3 solid water phantom. This phantom is suitable for quality assurance purposes since less than 2% average difference with respect to the water phantom measurements was found. In addition, output factors were assessed for different field sizes. Conclusions: A dosimetry protocol adequate for the specific features of the SSRT technique has been developed. This protocol allows measuring the absolute dose absorbed to water with an accuracy of 2%. It is therefore satisfactory for patient treatment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modeling Grid Data Flows for Transmission and Distribution Operations: Review, Design, Next Steps

Operational scenarios of the power grids grow multifold to accommodate the diverse needs of both the utilities and end consumers, and the various other stakeholders in-between. To comprehensively model and apply analytics to support objectives and business functions of grid sectors, a reliable approach to characterize and design data flows is crucial. The flows bridge business functions with communications protocols, stakeholders such as the grid actors, and data interfaces comprising different data objects. Additionally, constraints applied to the flow such as cybersecurity, trust, privacy, and ownership among others intersect these entities, requiring the delineation of their interactions under different scenarios. This paper aims to not only highlight relevant research in the space of grid data flows, but also proposes, for the transmission-distribution sector, a novel modeling approach that marries the aforementioned entities: objectives, business functions, data interfaces, communication protocols, data stakeholders, and flow constraints. It elaborates on the design philosophy and the significance of each entity within the model and applies it to an example function of fault location, isolation and service restoration (FLISR). Finally, the next steps to extend the application of this data flow model for other practical operational scenarios are discussed.

Sundararajan, Aditya [ORNL] (ORCID:000000033577854↗

Green chemistry design in polymers derived from lignin: review and perspective

The use of lignin for material and chemical applications has gained interest in recent times due to the environmental focus on using biomass for renewable materials as well as the motivation to valorize lignin as part of an integrated biorefinery. While a wealth of publications can be found for lignin-derived materials, and several reviews can be found on the topic, there are no reviews that outline and critically assess the sustainability of these protocols based on the criterion of the 12 Principles of Green Chemistry. This review assesses the literature for lignin- derived polymers over the past 20 years and highlights attempts to use biobased accompanying reagents, green solvents or solvent-less protocols, reports that replace traditionally toxic precursors (e.g. diisocyanates for polyurethanes), use mild conditions, valorize additional waste streams and prepare materials particularly biodegradable or recyclable. Here, the following work is a comprehensive and critical assessment of the green and sustainable nature of the state-of-the art of lignin-derived polymers (polyurethane, polyester, epoxy, phenolic resin, and others) utilizing actual biomass in the synthetic protocol. Each section of this review highlights and assesses published protocols that use a particularly green approach in one or more steps of the synthetic sequence. While many reports still contain traditional petroleum-derived and toxic methods along with more sustainable methods, the outline of all such green methods is able to create a landscape amidst lignin-derived polymer synthesis that points the way toward safer and more environmentally friendly materials.

36 MATERIALS SCIENCE↗

Minimize Solvent Oxidation with NO X Pre-Scrubbing

A novel method to remove nitrogen dioxide (NO 2 ) from the flue gas of coal-fired power plants with CO 2 capture was further developed for commercial implementation. The technology leverages the equipment and chemistry in an existing (sulfur dioxide) SO 2 polishing scrubber upstream of the main CO 2 capture unit to remove the NO 2 , preventing degradation of the CO 2 capture solvent and formation of nitrosamines (environmental hazards). The research in this report focuses on further evaluation of the chemical additives and operating conditions associated with the NO 2 removal process to define conditions for commercial scale testing and deployment. Experimental work systematically evaluated a series of potential additives to minimize the oxidation of sulfite in a representative SO 2 pre-scrubber solution (sulfite, in turn, absorbs NO 2 ). The additive combinations and concentrations were varied alongside important process conditions such as temperature, oxygen concentration, and metals present in solution to mimic the conditions expected in a commercial system. Important results of the parametric experimental work include identifying a new, potent sulfite oxidation inhibitor, revealing the importance of combining inhibitors with metal chelating agents, validation of a low-cost additive process, and development of a new semi-empirical model to represent mechanisms associated with sulfite oxidation. In addition, the experimental work reveled the impact of operating at higher temperatures (representative of a field test unit), which will guide the selection and concertation of additives as well. Engineering analysis found that waste solutions from the pre-scrubber with NO 2 additives may potentially be integrated with existing processes on site (e.g., flue gas desulfurization unit). In addition, techno-economic analysis identified potential net savings as large as $1.30/tonne CO 2 captured and quantified the potential benefit of low cost additive options actively being pursued by the development team. Finally, the experimental results and engineering analysis supported the development of a detailed field testing plan and protocol to evaluate the technology at near-commercial scale. The field test preparation included development of procedures to introduce chemical additives to an existing SO 2 polishing unit and identification of representative flue gas conditions based on a review of existing plants. These activities will have direct bearing on operation and design of commercial units.

20 FOSSIL-FUELED POWER PLANTS↗

Programmable Heisenberg interactions between Floquet qubits

Abstract The trade-off between robustness and tunability is a central challenge in the pursuit of quantum simulation and fault-tolerant quantum computation. In particular, quantum architectures are often designed to achieve high coherence at the expense of tunability. Many current qubit designs have fixed energy levels and consequently limited types of controllable interactions. Here by adiabatically transforming fixed-frequency superconducting circuits into modifiable Floquet qubits, we demonstrate an XXZ Heisenberg interaction with fully adjustable anisotropy. This interaction model can act as the primitive for an expressive set of quantum operations, but is also the basis for quantum simulations of spin systems. To illustrate the robustness and versatility of our Floquet protocol, we tailor the Heisenberg Hamiltonian and implement two-qubit iSWAP, CZ and SWAP gates with good estimated fidelities. In addition, we implement a Heisenberg interaction between higher energy levels and employ it to construct a three-qubit CCZ gate, also with a competitive fidelity. Our protocol applies to multiple fixed-frequency high-coherence platforms, providing a collection of interactions for high-performance quantum information processing. It also establishes the potential of the Floquet framework as a tool for exploring quantum electrodynamics and optimal control.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High throughput structure–property relationship for additively manufactured 316L/IN625 alloy mixtures leveraging 2-step Bayesian estimation

While the fabrication of graded materials by directed energy deposition (DED) has led to accelerated materials discovery, the ability to rapidly explore sufficiently large material composition spaces is limited due to the time-intensive nature of conventional materials characterization techniques. The present study investigates the viability of small punch test (SPT) protocols for rapidly evaluating DED-fabricated alloy mixtures of stainless steel 316L (316L) and Inconel 625 (IN625). The SPT protocols evaluated in this study include both the recently established two-step Bayesian estimation framework as well as the empirical relationships established in prior literature. It is shown that these protocols are capable of reliably and quantitatively tracking the changes in the mechanical properties of the alloy mixtures studied. Enhancement of mechanical properties was observed with the addition of IN625 to 316L, which is attributed to the austenite stabilization in the matrix and the formation of fine δ - Ni3Nb precipitates. It is shown that CALPHAD-based Scheil model simulations predicted the formation of different precipitate phases for each composition. The novel protocols presented in this paper open new avenues for high throughput material explorations for additive manufacturing.

2-step Bayesian estimation↗

Assessment of wafer scale MoS 2 atomic layers grown by metal–organic chemical vapor deposition using organo-metal, organo-sulfide, and H 2 S precursors

Transition Metal Dichalcogenides (TMDs) are a unique class of materials that exhibit attractive electrical and optical properties which have generated significant interest for applications in microelectronics, optoelectronics, energy storage, and sensing. Considering the potential of these materials to impact such applications, it is crucial to develop a reliable and scalable synthesis process that is compatible with modern industrial manufacturing methods. Metal–organic chemical vapor deposition (MOCVD) offers an ideal solution to produce TMDs, due to its compatibility with large-scale production, precise layer control, and high material purity. Optimization of MOCVD protocols is necessary for effective TMD synthesis and integration into mainstream technologies. Additionally, improvements in metrology are necessary to measure the quality of the fabricated samples more accurately. In this work, we study MOCVD of wafer-scale molybdenum disulfide (MoS 2 ) utilizing two common chalcogen precursors, H 2 S and DTBS. We then develop a metrology platform for wafer scale samples quality assessment. For this, the coalesced films were characterized using Raman spectroscopy, atomic force microscopy, transmission electron microscopy, X-ray photoelectron spectroscopy, and Kelvin probe force microscopy. We then correlate the structural analysis of these grown films with electrical performance by using aerosol jet printing to fabricate van der Pauw test structures and assess sheet resistance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An Automated Microfluidic Assay for Photonic Crystal Enhanced Detection and Analysis of an Antiviral Antibody Cancer Biomarker in Serum

Here, we report on the implementation of an automated platform for detecting the presence of an antibody biomarker for human papillomavirus-associated oropharyngeal cancer from a single droplet of serum, in which a nanostructured photonic crystal surface is used to amplify the output of a fluorescence-linked immunosorbent assay. The platform is comprised of a microfluidic cartridge with integrated photonic crystal chips that interfaces with an assay instrument that automates the introduction of reagents, wash steps, and surface drying. Upon assay completion, the cartridge interfaces with a custom laser-scanning instrument that couples light into the photonic crystal at the optimal resonance condition for fluorescence enhancement. The instrument is used to measure the fluorescence intensity values of microarray spots corresponding to the biomarkers of interest, in addition to several experimental controls that verify correct functioning of the assay protocol. In this work, we report both dose-response characterization of the system using anti-E7 antibody introduced at known concentrations into serum and characterization of a set of clinical samples from which results were compared with a conventional enzyme-linked immunosorbent assay (ELISA) performed in microplate format. Finally, the demonstrated capability represents a simple, rapid, automated, and high-sensitivity method for multiplexed detection of protein biomarkers from a low-volume test sample.

59 BASIC BIOLOGICAL SCIENCES↗

A Privacy-Preserving Cyber Threat Intelligence Sharing System

Cyber Threat Intelligence (CTI) is a key resource for developing defensive strategies against potential cyber adversaries. Entities typically access CTI through open-source platforms, national agencies, or specialized commercial services. However, the bi-directional exchange of CTI is hindered by organizational trust boundaries, which complicate the sharing processes between entities and CTI providers. Centralized CTI services benefit from receiving suspicious cyber observables such as IP addresses, domain names, and email addresses from various entities. The aggregation allows for the correlation of widespread adversarial activities to enhance the alert and response mechanisms across the network of involved parties. Despite these benefits, openly sharing such observables incurs potential legal, regulatory, and reputational risks for the disclosing entities.This paper introduces a system designed to facilitate the secure exchange of cyber observables across trust boundaries without compromising the anonymity of the sharing entities. Here, we propose an architecture that leverages common web protocols alongside zero-knowledge proofs to authenticate members while maintaining anonymity. Additionally, we outline a privacy model tailored for STIX (Structured Threat Information eXpression) cyber observables to minimize the risk of inadvertently disclosing private information. Through our threat models, we assess the privacy implications of our proposed system and demonstrate its potential to enhance collaborative cyber defense efforts without exposing entities to undue risk.

BBS+ Signatures↗

SU-F-J-163: In Vivo Quantification of Sequence Parameter Effect On Geometric Distortion Caused by Implanted Titanium Brachytherapy Applicator

Purpose: The use of MR to plan and evaluate brachytherapy treatment for cervical cancer is increasing given the availability of MR conditional or safe applicators and MRI’s proven superiority to CT for characterizing soft tissue lesions. The titanium applicators, however, cause geometric distortions or imaging artifacts, which reduce the utility of MRI for dosimetry. We sought to quantify the observed volume of the same applicator on a previously optimized T2 sequence in comparison to the conventional T2 sequence and CT obtained for brachytherapy planning. Methods: Prior work with testing in phantoms showed that increases in readout bandwidth yielded reductions in artifact area and distortion measurements even with voxel increases. Following IRB approval, nine patients with titanium tandem & ovoid applicator (Varian Medical Systems) in place were scanned with a standard periprocedural protocol which included sagittal T2 fast spin echo (FSE) acquisition (res 0.98×0.78×4.0 mm{sup 3}; BW 200Hz). An additional T2-weighted FSE sequence (res 0.98×0.98×3–4 mm{sup 3}; BW500Hz) with increased readout bandwidth, readout voxel size, and echo train length was added to the protocol. Volume measurements of the applicator (from tip to cervical stop) were hand-segmented in Velocity AI 3.1 (Velocity Medical Solutions) for the two T2 FSE sequences and a planning CT obtained shortly after MRI. Differences were analyzed using a paired t-test. Results: Average apparent volumes of the applicator on standard T2 sequence, decreased bandwidth T2 sequence and CT were 5.922±1.283 cm{sup 3}, 4.544±1.524 cm3, and 2.304±0.509 cm{sup 3} respectively. Conclusion: Apparent volumes of a brachytherapy applicator can be compared in vivo. The modified sequence results in decreased apparent size of the cervical applicator. Both MR sequence volumes were larger than the planning CT, which was expected. Future work will focus on the diagnostic quality of the new sequence and quantifying any geometric shifts after CT to MRI registration based on anatomical landmarks.

60 APPLIED LIFE SCIENCES↗

Duke Forest FACE (FACTS-I): Meteorological and Soil Data

This dataset, collected from Duke Forest Free Air CO2 Enrichment (FACE) – Forest-Atmosphere Carbon Transfer and Storage (FACTS-I) experiment, includes variables describing the meteorological conditions above canopy, within canopy, and soil depending on the variable. The Duke FACE experiment was located in a loblolly pine (Pinus taeda L.) plantation established in 1983. Naturally regenerated broadleaved species including sweetgum (Liquidambar styraciflua L.) and tulip poplar (Liriodendron tulipifera L.), mostly in the overstory, and winged elm (Ulmus alata Michx.) and red maple (Acer rubrum L.) were common in the understory. The FACE experiment commenced with two plots (plots 7-8) in 1994 (Oren et al. 2001), with six additional plots (plots 1-6) coming online on 27 August 1996. The CO2 enrichment was terminated on 31 October 2010 and post-enrichment data collection continued through 2012. Complete fertilization was applied annually to half of plots 7-8 from 1998 to 2004. The nutrient addition experiment expanded to half of plot 1-6 with a common protocol of N-fertilization in 2005. N-fertilization continued until 2012. The data range varied by sensor availability. A summary of information about variable name and data range can be found in the ‘FileDescription_[variable_name].txt’ files.

54 ENVIRONMENTAL SCIENCES↗

Duke Forest FACE (FACTS-I): Plant and Soil Response Data

This dataset describing the responses of plant and soil pools and fluxes to elevated atmospheric CO2 concentration and increased nitrogen supply was collected from Duke Forest Free Air CO2 Enrichment (FACE) – Forest-Atmosphere Carbon Transfer and Storage (FACTS-I) experiment from 1996 to 2012. The dataset includes data files for allometry (diameter at breast height, tree height, and height to live crown base), leaf area index, biomass (stem, branch, foliage, and root biomass, tree density, and basal area), net primary productivity (stem, branch, foliage, reproductive, and coarse root NPP), sap flux density, soil CO2 efflux, and stem temperature. Data files were formatted as .csv (Microsoft Excel or other spreadsheet programs can be used to read the format) and file descriptions, including variable name, unit, and data range, can be found in ‘FileDescription_[data_name].txt’ files. The Duke FACE experiment was in a loblolly pine (Pinus taeda L.) plantation established in 1983. Naturally regenerated broadleaved species including sweetgum (Liquidambar styraciflua L.) and tulip poplar (Liriodendron tulipifera L.), mostly in the overstory, and winged elm (Ulmus alata Michx.) and red maple (Acer rubrum L.) were common in the understory. The FACE experiment commenced with two plots (plots 7-8) in 1994 (Oren et al. 2001), with six additional plots (plots 1-6) coming online on 27 August 1996. CO2 enrichment was terminated on 31 October 2010 and post-enrichment data collection continued through 2012. Complete fertilization was applied annually to half of plots 7-8 from 1998 to 2004. The nutrient addition experiment expanded to half of plots 1-6 with a common protocol of N-fertilization in 2005 and continued until 2012. The levels of treatment in this dataset were expressed as ambient CO2 (AMB) or elevated CO2 (ELE) for CO2 treatment and control soil (CONT) or fertilized soil (FERT) for N treatment, respectively.

54 ENVIRONMENTAL SCIENCES↗

FINAL REPORT - Development of High Pressure Hydrogen Storage Tank for Storage and Gaseous Truck Delivery

The “Development of High Pressure Hydrogen Storage Tanks for Storage and Gaseous Truck Delivery” project [DE-FG36-08GO18062] was initiated on 01 July 2008. Hexagon Lincoln (then Lincoln Composites) received grant funding from the U.S. Department of Energy to support the design and development of an improved bulk hauling and storage solution for hydrogen in terms of cost, safety, weight and volumetric efficiency. The development of this capability required parallel development and qualification of large all-composites pressure vessels, a custom ISO container to transport and store said tanks, and performance of trade studies to identify optimal operating pressure for the system. Qualification of the 250 bar TITAN® module was completed in 2009 with supervision from the American Bureau of Shipping [ABS], and the equipment has been used internationally for bulk transportation of fuel gases since 2010. Phase 1 of the project was successfully completed in 2012 with the issuance of USDOT SP 14951, the special permit authorizing the manufacture, marking, sale and use of TITAN® Mobile Pipeline® equipment in the United States. The introduction of tube trailers with light weight composite tankage has meant that 2 to 3 times as much gaseous fuel can be transported with each trip. This increased hauling efficiency offers dramatically reduced operating costs and has enabled a profitable business model for over-the-road compressed natural gas delivery. The economic drivers of this business opportunity vary from country to country and region to region, but in many places gas distribution companies have realized profitable operations. Additional testing was performed in 2015 to characterize hydrogen-specific operating protocols for use of TITAN® systems in CHG service at 250 bar. This program demonstrated that existing compression and decompression methodologies can efficiently and safely fill and unload lightweight bulk hauling systems. Hexagon Lincoln and U.S. DOE agreed to continue into Phase 2 of the project without pursuing the development of higher pressure capabilities as originally planned. At 250 bar, development of equipment for hydrogen transport is supported by strong activity in the adjacent natural gas transportation sector. Trade studies performed since 2011 indicate optimization of hauling efficiency and system cost for hydrogen transport at about 350 bar (5076 psi). However, due to reduced efficiency of compression of natural gas above 250 bar, 350 bar operation is not an attractive option for natural gas transportation. The CHG market is not developed at this time, and it is difficult to forecast the arrival of significant revenues. On the investment side, the cost to fully qualify a large tank module at 350 bar is estimated at $3MM to $5MM. There is insufficient CHG market definition to support a stand-alone business case for this investment without near term revenue in the adjacent CNG transportation market. Therefore development of a 350 bar TITAN® system was deferred and not pursued under this project. Hexagon Lincoln continues to support the development of tankage and equipment for operation at 350 bar and above; with 700 bar vehicle tanks and 950 bar tanks for ground storage applications. Phase 2 activities were focused on reducing system cost, increasing system capacity, increasing system safety and characterization of polymer material performance specific to hydrogen pressure vessel usage. With the successful launch of TITAN® modules and trailers in natural gas transportation, over 600 units have been produced through the end of 2016, resulting in improved purchasing power for raw materials and manufactured components. This has allowed Hexagon Lincoln to approach the current project goals for system cost. At $590/kg of compressed hydrogen delivered, the system cost of the baseline TITAN® module is below the project’s 2015 target of $730/kg H2 delivered, and very close to the project’s 2020 target of $575/kg H2 delivered. [Based on product pricing in 1Q2017.] Emphasis was placed on configuration of larger capacity systems within the vehicle weights and dimensions allowed on federal and state highways in the United States and other countries. These activities resulted in the design and development of integrated tube trailer systems that have increased delivery capacities by 45%. The hydrogen delivery capacity of our largest system is 845 kg, exceeding the project’s 2015 target of 700 kg H2 delivered. Emerging technologies offering improvement of the safety systems used on the equipment were investigated, with particular focus on improving the reliability and cost of the emergency venting system for fire protection. Finally, investment in our materials laboratory improved detection and characterization of hydrogen-induced damage in polymer materials, supporting the development of operational protocols to avoid damage to pressure vessel liners and valve components.

08 HYDROGEN↗

Optimization of electroporation method and promoter evaluation for type-1 methanotroph, Methylotuvimicrobium alcaliphilum

Methanotrophic bacteria are promising hosts for methane bioconversion to biochemicals or bioproducts. However, due to limitations associated with long genetic manipulation timelines and, lack of choice in genetic tools required for strain engineering, methanotrophs are currently not employed for bioconversion technologies. In this study, a rapid and reproducible electroporation protocol is developed for type 1 methanotroph, Methylotuvimicrobium alcaliphilum using common laboratory solutions, analyzing optimal electroshock voltages and post-shock cell recovery time. Successful reproducibility of the developed method was achieved when different replicative plasmids were assessed on lab adapted vs. wild-type M. alcaliphilum strains (DASS vs. DSM19304). Overall, a ∼ 3-fold decrease in time is reported with use of electroporation protocol developed here, compared to conjugation, which is the traditionally employed approach. Additionally, an inducible (3-methyl benzoate) and a constitutive (sucrose phosphate synthase) promoter is characterized for their strength in driving gene expression.

59 BASIC BIOLOGICAL SCIENCES↗

The Cementitious Barriers Partnership Experimental Programs and Software Advancing DOE’s Waste Disposal/Tank Closure Efforts – 15436

The U.S. Department of Energy Environmental Management (DOE-EM) Office of Tank Waste Management-sponsored Cementitious Barriers Partnership (CBP) is chartered with providing the technical basis for implementing cement-based waste forms and radioactive waste containment structures for long-term disposal. DOE needs in this area include the following to support progress in final treatment and disposal of legacy waste and closure of High-Level Waste (HLW) tanks in the DOE complex: long-term performance predictions, flow sheet development and flow sheet enhancements, and conceptual designs for new disposal facilities. The DOE-EM Cementitious Barriers Partnership is producing software and experimental programs resulting in new methods and data needed for end-users involved with environmental cleanup and waste disposal. Both the modeling tools and the experimental data have already benefited the DOE sites in the areas of performance assessments by increasing confidence backed up with modeling support, leaching methods, and transport properties developed for actual DOE materials. In 2014, the CBP Partnership released the CBP Software Toolbox –“Version 2.0” which provides concrete degradation models for 1) sulfate attack, 2) carbonation, and 3) chloride initiated rebar corrosion, and includes constituent leaching. These models are applicable and can be used by both DOE and the Nuclear Regulatory Commission (NRC) for service life and long-term performance evaluations and predictions of nuclear and radioactive waste containment structures across the DOE complex, including future SRS Saltstone and HLW tank performance assessments and special analyses, Hanford site HLW tank closure projects and other projects in which cementitious barriers are required, the Advanced Simulation Capability for Environmental Management (ASCEM) project which requires source terms from cementitious containment structures as input to their flow simulations, regulatory reviews of DOE performance assessments, and Nuclear Regulatory Commission reviews of commercial nuclear power plant (NPP) structures which are part of the overall US Energy Security program to extend the service life of NPPs. In addition, the CBP experimental programs have had a significant impact on the DOE complex by providing specific data unique to DOE sodium salt wastes at Hanford and SRS which are not readily available in the literature. Two recent experimental programs on cementitious phase characterization and on technetium (Tc) mobility have provided significant conclusions as follows: recent mineralogy characterization discussed in this paper illustrates that sodium salt waste form matrices are somewhat similar to but not the same as those found in blended cement matrices which to date have been used in long-term thermodynamic modeling and contaminant sequestration as a first approximation. Utilizing the CBP generated data in long-term performance predictions provides for a more defensible technical basis in performance evaluations. In addition, recent experimental studies related to technetium mobility indicate that conventional leaching protocols may not be conservative for direct disposal of Tc-containing waste forms in vadose zone environments. These results have the potential to influence the current Hanford supplemental waste treatment flow sheet and disposal conceptual design.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The cementitious barriers partnership experimental programs and software advancing DOE's waste disposal/tank closure efforts - 15436

The U.S. Department of Energy Environmental Management (DOE-EM) Office of Tank Waste Management sponsored Cementitious Barriers Partnership (CBP) is chartered with providing the technical basis for implementing cement-based waste forms and radioactive waste containment structures for long-term disposal. DOE needs in this area include the following to support progress in final treatment and disposal of legacy waste and closure of High-Level Waste (HLW) tanks in the DOE complex: - Long-term performance predictions and - Flow sheet development and flow sheet enhancements - Conceptual designs for new disposal facilities The DOE-EM Cementitious Barriers Partnership is producing software and experimental programs resulting in new methods and data needed for end-users involved with environmental cleanup and waste disposal. Both the modeling tools and the experimental data have already benefited the DOE sites in the areas of performance assessments by increasing confidence backed up with modeling support, leaching methods, and transport properties developed for actual DOE materials. In 2014, the CBP Partnership released the CBP Software Toolbox - 'Version 2.0' which provides concrete degradation models for: 1) sulfate attack, 2) carbonation, 3) chloride initiated rebar corrosion, and includes constituent leaching. These models are applicable and can be used by both DOE and the Nuclear Regulatory Commission (NRC) for service life and long-term performance evaluations and predictions of nuclear and radioactive waste containment structures across the DOE complex (Figure 1) including Future SRS salt-stone and HLW tank performance assessments and special analyses - Hanford site HLW tank closure projects and other projects in which cementitious barriers are required - The Advanced Simulation Capability for Environmental Management (ASCEM) project which requires source terms from cementitious containment structures as input to their flow simulations - Regulatory reviews of DOE performance assessments - Nuclear Regulatory Commission reviews of commercial nuclear power plant (NPP) structures which are part of the overall US Energy Security program to extend the service life of NPPs In addition, the CBP experimental programs have had a significant impact on the DOE complex by providing specific data unique to DOE sodium salt wastes at Hanford and SRS which are not readily available in the literature. Two recent experimental programs on cementitious phase characterization and on technetium (Tc) mobility have provided significant conclusions as summarized below: Recent mineralogy characterization discussed in this paper illustrates that sodium salt waste form matrices are somewhat similar to but not the same as those found in blended cement matrices which to date have been used in long-term thermodynamic modeling and contaminant sequestration as a first approximation. Utilizing the CBP generated data in long-term performance predictions provides for a more defensible technical basis in performance evaluations. - In addition, recent experimental studies related to technetium mobility indicate that conventional leaching protocols may not be conservative for direct disposal of Tc- containing waste forms in vadose zone environments. These results have the potential to influence the current Hanford supplemental waste treatment flow sheet and disposal conceptual design. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Certifying the Performance of Fixative Technologies under Open Air Demolition Activities for D and D - 20096

Department of Energy (DOE) facilities undergoing deactivation and decommissioning (D and D) activities struggle with safety concerns of residual radioactive contamination leftover after gross decontamination efforts have concluded. The positive effects of implementing fixative technologies for decommissioning and maintenance is known across the DOE complex. However, there is no standardized metric in place that quantifies the performance of these technologies such as incombustible fixative platforms that immobilize the contamination in a solid polymer material under normal operating conditions or when exposed to stressors. The primary focus of this research is to provide the empirical data necessary to properly characterize the effects of implementing fixative technologies on mitigating the release of contamination. In addition, this effort has been used to identify and establish uniform testing protocols to quantify operational parameters of fixating platforms and properly credit such systems under a variety of operational conditions and stressors that can arise during open air demolition efforts (e.g. impact, water, thermal, etc.). The established protocols will be provided to the ASTM International E10.03 Subcommittee on Radiological Protection for Decontamination and Decommissioning of Nuclear Facilities and Components for the potential of formal standardization. Attributes to be addressed during testing are material compromise from impact stress, thermal stress for incombustible fixative materials, and immobilization factors (how well an immobilizing platform is capable of retaining fixated material during thermal and impact stressors). In developing these test methods, a greater understanding of the material's behavior under anticipated and unanticipated events, such as decommissioning activities and contingency events as outlined in the Basis of Interim Operations (BIO), can be successfully characterized. There are several key components of the experimental methodology that is essential in empirically certifying fixative technologies. A surrogate contaminant with a unique signature has been utilized with the implementation of a uniform contamination process of test coupons that is quantifiable and replicable for direct fixative comparisons. A modular test chamber has also been used to apply the various stressors of interest. Collection of released contamination that includes airborne and resettled contaminant particles and analyzed using mass spectrometry. This research directly supports DOE complex-wide concerns in terms of final disposition of nuclear facilities and the considerations made during their time between ceasing facility operation and final disposition. The results of this effort aims to provide a standardized road map and logical decision flow to better facilitate fixative technologies into D and D activities required to achieve the desired facility end state. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Total metals & anion concentration data; Slate River floodplain, Crested Butte, CO; May 2020-September 2020

This data package includes processed and undiluted measurements for metal and anion concentrations from pore water (groundwater) samples from the Slate River floodplain of Crested Butte, CO, a focus field site for the SLAC Floodplain Hydro-Biogeochemistry SFA. The data was generated as part of the work targeting the overarching research question for the SLAC SFA: How do ubiquitous subsurface interfaces mediate molecular-scale biogeochemical processes and groundwater quality in floodplains and watersheds? Samples were collected between May and September of 2020. These measurements were all recorded at the Arizona Laboratory for Emerging Contaminants (ALEC) at the University of Arizona located in Tucson, AZ. Groundwater samples were extracted from a network of installed rhizon (Rhizosphere Research Products, part no. 19.60.21F, 0.6 micrometer mesh size) and piezometer wells within the river floodplain. All water samples were shaded from sun exposure during extraction from the subsurface and preserved at 4C until measured at ALEC.Analysis by ICP-MS:Measurements for total metals were made on the Agilent 7700x ICP-MS (for total metals) – Agilent Technologies, Santa Clara, CA.The analytical QA/QC protocol was adapted from US EPA Method 200.8 for analysis by ICP-MS. Calibration standards were prepared from multi-element stock solution (Sigma-Aldrich Multielement standard solution for ICP, St. Louis, MO) using matrix matched to sample solutions (either 2% HCl or HNO3 from AriStar Plus,grade acids from VWR Scientific). Calibration curves include at least 7 points with correlation coefficients > 0.995. The QC protocol includes a continuing calibration blank (CCB), a continuing calibration verification (CCV) solution and at least one quality control sample (QCS) to be analyzed just after calibration and again after every 12 samples and at the completion of the run. The QCS solutions are from an independent source, such as NIST SRM 1643e - Trace Elements in Water, or QCS solutions from High Purity Standards (Charleston, SC). Acceptable QC responses must be between 90 and 110% of the certified value. An internal standard (Rh) is added via on-line addition into the sample line using a mixing tee.Analysis by Ion Chromatography (Anions):The protocol follows Method 4110 in Standard Methods for Examination of Water and Wastewater.The instrument used is the Thermo Scientific Dionex ICS-6000 using AS+AG22 column set for anion analysis with isocratic method using sodium carbonate eluent. Detection is by chemical suppression of eluent conductivity. Quality control solutions and mixed analyte standards purchased from Inorganic Ventures, Christiansburg, VA.All files are in csv format.

54 ENVIRONMENTAL SCIENCES↗