Numerical study of chemically reacting flows using an LU scheme

A new computational fluid dynamic code has been developed for the study of mixing and chemical reactions in the flow fields of ramjets and scramjets. The code employs an implicit finite volume, lower-upper symmetric successive overrelaxation scheme for solving the complete two-dimensional Navier-Stokes equations and species transport equations in a fully-coupled and very efficient manner. The combustion processes are modeled by an 8-species, 14-step finite rate chemistry model whereas turbulence is simulated by a Baldwin-Lomax algebraic model. The validity of the code is demonstrated by comparing the numerical calculations with both experimental data and previous calculations of a cold flow helium injection into a straight channel and premixed hydrogen-air reacting flows in a ramped duct. The code is then used to calculate the mixing and chemical reactions of a hydrogen jet transversely injected into a supersonic airstream. Results are presented describing the flow field, the recirculation regions in front and behind the injector, and the chemical reactions.

Shuen, Jian Shun↗

Flight Tests of a 1/6-Scale Model of the Hawker P 1127 Jet VTOL Airplane

An experimental investigation has been made to determine the dynamic stability and control characteristics of a 1/6-scale flying model of the Hawker P lIP7 jet vertical-take-off-and-landing (VTOL) airplane in hovering and transition flight. The model was powered by a counter-rotating ducted fan driven by compressed-air jets at the tips of the fan blades. In hovering flight the model was controlled by jet-reaction controls which consisted of yaw and pitch jets at the extremities of the fuselage and a roll jet on each wing tip. In forward flight the model was controlled by conventional ailerons and rudder and an all-movable horizontal tail. In hovering flight the model could be flown smoothly and easily, but the roll control was considered too weak for rapid maneuvering or hovering in gusty air. Transitions from hovering to normal forward flight and back to hovering could be made smoothly and consistently and with only moderate changes in longitudinal trim. The model had a static longitudinal instability or pitch-up tendency throughout the transition range, but the rate of divergence in the pitch-up was moderate and the model could be controlled easily provided the angle of attack was not allowed to become too high. In both the transition and normal forward flight conditions the lateral motions of the model were difficult to control at high angles of attack, apparently because of low directional stability at small angles of sideslip. The longitudinal stability of the model in normal forward flight was generally satisfactory, but there was a decided pitch-up tendency for the flap-down condition at high angles of attack. In the VTOL landing approach condition, with the jets directed straight down or slightly forward, the nose-down pitch trim required was greater than in the transitions from hovering to forward flight, but the longitudinal instability was about the same. Take-offs and landings in still air could be made smoothly although there was a slight unfavorable ground effect on lift and a nose-down change in pitch trim near the ground. Short take-offs and landings could be made smoothly and consistently although the model experienced a decided nose-up change in pitching moment as it climbed out of ground effect.

Smith, Charles C., Jr.↗

A temperature correlation for the radiation resistance of a thick-walled circular duct exhausting a hot gas

It is often useful to know the radiation impedance of an unflanged but thick-walled circular duct exhausting a hot gas into relatively cold surroundings. The reactive component is shown to be insensitive to temperature, but the resistive component is shown to be temperature dependent. A temperature correlation is developed permitting prediction of the radiation resistance from a knowledge of the temperature difference between the ambient air and the gas flowing from the duct, and a physical basis for this correlation is presented.

Mahan, J. R.↗

Solar heating system

A system is disclosed for using solar energy to heat the interior of a structure. The system utilizes a low cost solar collector to heat a recirculating air mass which then flows through a series of interconnected ducts and passageways without the use of exterior fans or blowers. Heat is transferred from the air mass to the structure's interior and the air mass is then reheated.

Jensen, R. N.↗

Assessment of the 3420 Building Filtered Exhaust Stack Sampling Probe Location: Stack Verification Following Fan and Air Blender Additions

The Pacific Northwest National Laboratory (PNNL) 3420 Building, which is part of the Physical Sciences Facility (PSF), houses radiological capabilities that results in the requirement that emissions monitoring must be conducted for potential radionuclides in the exhaust air discharge of this building. The air monitoring system is required to conform to Title 40 of the Code of Federal Regulations part 61 (40 CFR 61) Subpart H, which in turns requires a sampling probe in the exhaust stream to conform to the criteria of American National Standards Institute / Health Physics Society (ANSI/HPS) N13.1-2011, Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stack and Ducts of Nuclear Facilities. To support the air emissions permit for the 3420 Building on the PNNL campus, stack testing that used computational fluid dynamics (CFD) modeling as a surrogate stack and verification tests of velocity uniformity and flow angle on the retrofitted facility stack was performed. The ANSI/HPS N13.1-2011 criteria for the air monitoring probe location are that velocity uniformity, gaseous tracer uniformity, and particulate tracer uniformity must be less than or equal to 20%COV. Furthermore, no point in the sampling location may have a gaseous tracer concentration that varies from the mean concentration by more than 30%. Additionally, the flow angle at the sampling location must not be more than 20°. The CFD modeling of the stack, as reported by Recknagle et al. (2018) demonstrated that the stack meets the criteria at the probe location. The velocity uniformity and flow angle results from the 3420 stack verification tests, performed in October 2020, demonstrated that the CFD model results may be used to support the qualification of the stack sampling location. The measured velocity uniformity verification test result was 1.4%COV. This value is well within the uniformity criterion, which is that the velocity uniformity be =20%COV. Additionally, this value is well within the criterion that the actual stack measurement must be within 5% of the surrogate stack result of 2.1%COV when all four fans were operating. Additionally, the measured average flow angle at the 3420 stack monitor location was 15.5 degrees. Although this is higher than expected based on the CFD model, the result is =20 degrees, so the criterion is met. Based on these stack verification test results, the reconfigured 3420 Building filtered exhaust stack meets the qualification criteria given in the ANSI/HPS N13.1-2011 standard. Further changes to the system configuration or operating conditions that are outside the bounds described in this and the CFD report (Recknagle et al., 2018) may require additional tests and additional analysis to determine compliance with the standard.

3420 Building↗

, Experimental Investigation of Electrically Charged Water Droplets Two-Phase Cross-Flow Interactions with Humid

Electrically charged water droplets can capture water vapor molecules in surrounding moist air and promote vapor condensation. This concept unfolds an alternative to mechanical cooling-based air dehumidification systems that separate sensible and latent cooling loads in HVAC applications. The effect of dielectrophoresis, electro-hydrodynamic, and micro-diffusive flows due to highly electrically charged water droplets traveling through moist air were investigated as new methods to reduce the air’s water vapor content. This paper presents new experimental data on humidification and power consumption for a system consisting of highly energized electrosprays in combination with mist eliminators. Electrosprays produced highly charged water spray cones crossing the air perpendicularly and upwardly. The moist air stream was circulated in a horizontal duct at 22C, 80% relative humidity, and 0.24 ms-1 airspeed. Mist eliminators made of stainless wire clothes of 36 and 25 μm pore diameter were used to screen the droplets growing during their flight trajectory. The mist eliminators blocked some of the largest diameter droplets. Still, they could not prevent re-evaporation of the droplets into the bulk air from the droplets deposited on their wire clothes. The equilibrium between the dielectrophoresis condensation from the electrosprays and the droplets’ re-evaporation phenomena resulted in reduced humidification when compared to conventional-type spray evaporative cooling systems. However, to dehumidify the air, the droplets injected by the electrosprays must be separated entirely and promptly removed from the bulk airflow at the end of their flight trajectory.

Electrostatic droplets, Electrospray, humidificati↗

Intercooler cooling-air weight flow and pressure drop for minimum drag loss

An analysis has been made of the drag losses in airplane flight of cross-flow plate and tubular intercoolers to determine the cooling-air weight flow and pressure drop that give a minimum drag loss for any given cooling effectiveness and, thus, a maximum power-plant net gain due to charge-air cooling. The drag losses considered in this analysis are those due to (1) the extra drag imposed on the airplane by the weight of the intercooler, its duct, and its supports and (2) the drag sustained by the cooling air in flowing through the intercooler and its duct. The investigation covers a range of conditions of altitude, airspeed, lift-drag ratio, supercharger-pressure ratio, and supercharger adiabatic efficiency. The optimum values of cooling air pressure drop and weight flow ratio are tabulated. Curves are presented to illustrate the results of the analysis.

Reuter, J George↗

The effects of air leaks on solar air heating systems

This paper presents the results of an investigation to determine the effects of leakages in collector and duct work on the system performance of a typical single-family residence solar air heating system. Positive (leakage out) and negative (leakage in) pressure systems were examined. Collector and duct leakage rates were varied from 10 to 30 percent of the system flow rate. Within the range of leakage rates investigated, solar contribution to heated space and domestic hot water loads was found to be reduced up to 30 percent from the no-leak system contribution with duct leakage equally divided between supply and return duct; with supply duct leakage greater than return leakage a reduction of up to 35 percent was noted. The negative pressure system exhibited a reduction in solar contribution somewhat larger than the positive pressure system for the same leakage rates.

Elkin, R.↗

Novel Tilting Ducted-Fan Aerial Vehicle Configurations

There has been recent renewed interested in ducted-fan, powered-lift vertical takeoff and landing aircraft vehicles for uninhabited aerial vehicle and urban aerial mobility aerial applications. Early work was conducted in the 1950’s to the late 1980’s into ducted-fan vehicles, especially at the time for military missions. The focus of ducted-fan research began to shift to UAV’s and personal air transportation in the 2000’s. Work in the early 2000’s fostered interest into ducted-fan aerial vehicles for vertical lift planetary aerial vehicle missions, especially for missions to Titan, a moon of Saturn. For example, early work at NASA Ames conducted the first known investigation into oval ducts (with internal tandem fans) to be used for these aerial vehicles. The use of twin oval ducts (with internal tandem fans) allowed the use of quadrotor-style rotor rpm control for vehicle trim (in hover, for transition to high-speed forward flight the addition of a tilt-actuator to pitch the twin oval ducts forward to be aligned with the freestream needed to be added to the control approach. This current study explores open-rotor, single isolated ducted-fan, and full vehicle configuration aerodynamic performance for hover, transition, and cruise regimes for novel tilting ducted-fan aerial vehicle configurations. The objective of this study is to better understand the design aerodynamics trade space for noncircular tilting ducted-fans. The primary analysis tool used in this paper is the mid-fidelity computational fluid dynamics RotCFD tool. Several interesting and largely unexplored rotor-on-rotor (or fan-on-fan), duct-on-rotor, rotor- on-duct, and duct-on-airframe are examined in this paper. Many of these aerodynamic interactions are the key to overall aerial vehicle performance. Limited parametric sweeps of rotor-to-rotor spacing (and, therefore, sizing and shape of the enveloping ducts) for the various duct configurations will also be performed. The trade-offs between duct thrust augmentation in hover versus improved transition controllability versus improved cruise L/D will be discussed for various novel duct configurations. These ducted-fan configurations include oval ducts, ‘figure-eight’ ducts, and ‘B-shaped’ ducts, among others.

Ducted-Fan↗

Method of Matching Performance of Compressor Systems with that of Aircraft Power Sections

A method is developed of easily determining the performance of a compressor system relative to that of the power section for a given altitude. Because compressors, reciprocating engines, and turbines are essentially flow devices, the performance of each of these power-plant components is presented in terms of similar dimensionless ratios. The pressure and temperature changes resulting from restrictions of the charge-air flow and from heat transfer in the ducts connecting the components of the power plant are also expressed by the same dimensionless ratios and the losses are included in the performance of the compressor. The performance of a mechanically driven, single-stage compressor in relation to the performance of a conventional air-cooled engine operating at sea-level conditions is presented as an example of the application of the method.

Bullock, Robert O.↗

Heat Transfer in a Superelliptic Transition Duct

Local heat transfer measurements were experimentally mapped using a transient liquid-crystal heat transfer technique on the surface of a circular-to-rectangular transition duct. The transition duct had a length-to-diameter ratio of 1.5 and an exit-plane aspect ratio of 3. The crosssectional geometry was defined by the equation of a superellipse. The cross-sectional area was the same at the inlet and exit but varied up to 15 percent higher through the transition. The duct was preheated to a uniform temperature (nominally 64 C) before allowing room temperature air to be suddenly drawn through it. As the surface cooled, the resulting isothermal contours on the duct surface were revealed using a surface coating of thermochromic liquid crystals that display distinctive colors at particular temperatures. A video record was made of the surface temperature and time data for all points on the duct surfaces during each test. Using this surface temperature-time data together with the temperature of the air flowing through the model and the initial temperature of the model wall, the heat transfer coefficient was calculated by employing the classic one-dimensional, semi-infinite wall heat transfer conduction model. Test results are reported for inlet diameter-based Reynolds numbers ranging from 0.4x106 to 2.4x106 and two grid-generated freestream turbulence intensities of about 1 percent, which is typical of wind tunnels, and up to 16 percent, which may be more typical of real engine conditions.

Poinsatte, Philip↗

Cloud Condensation Nuclei Measurements in Tropical Cyclones

The first measurements of cloud condensation nuclei (CCN) within and around tropical cyclones were made with the Desert Research Institute (DRI) CCN spectrometer (Hudson 1909) from a NOAA P-3 Hurricane Hunter aircraft throughout the 2001 season. Two penetrations of the closed eye of Hurricane Erin off the northeast US coast on Sept. 10 showed concentrations consistently well in excess of 1000 per cubic cm at approximately 1.4% supersaturation. Simultaneous condensation nuclei (CN--total particle) concentrations were consistently well in excess of 2000 per cubic cm throughout these closed eye penetrations. These within eye measurements at 4 km altitude for exceeded CCN and CN measurements just outside of the storm at similar altitudes--300 and 600 per cubic cm respectively. These CCN and CN concentrations within this closed eye were far above concentrations in maritime air masses; they are characteristic of continental or polluted air masses. Although there was a possibility that Saharan duct may have gotten into this storm these sub tenth micrometer particles are much too small and much too numerous to be dust. Such high concentrations may have originated from European air pollution, which may have been transported by similar airflow patterns to those that carry Saharan dust across the Atlantic. These high concentrations may be a manifestation of descending air that brings higher concentrations that are often characteristic of the upper troposphere (Clarke and Kapustin 2002). Later in the month measurements in Humberto showed highly variable CCN and CN concentrations that ranged from lots than 5 per cubic cm to more than 1000 per Cubic cm over km scale distances within and around the open eye of this tropical storm/hurricane. These very low concentrations suggest strong cloud scavenging.

Hudson, J. G.↗

All-metal muffler for ducts

Steel- or aluminum-skinned baffles absorb sound from air flowing over them. Because there is no bulk filler, muffler does not collect contaminants. If dirt accumulates on skin, it can be washed away without damaging muffler.

Soderman, P. T.↗

Effects of interstage diffuser flow distortion on the performance of a 15.41-centimeter tip diameter axial power turbine

The performance of a variable-area stator, axial flow power turbine was determined in a cold-air component research rig for two inlet duct configurations. The two ducts were an interstage diffuser duct and an accelerated-flow inlet duct which produced stator inlet boundary layer flow blockages of 11 percent and 3 percent, respectively. Turbine blade total efficiency at design point was measured to be 5.3 percent greater with the accelerated-flow inlet duct installed due to the reduction in inlet blockage. Blade component measurements show that of this performance improvement, 35 percent occurred in the stator and 65 percent occurred in the rotor. Analysis of inlet duct internal flow using an Axisymmetric Diffuser Duct Code (ADD Code) were in substantial agreement with the test data.

Mclallin, K. L.↗

Effects of interstage diffuser flow distortion on the performance of a 15.41-centimeter tip diameter axial power turbine

The performance of a variable-area stator, axial flow power turbine was determined in a cold-air component research rig for two inlet duct configurations. The two ducts were an interstage diffuser duct and an accelerated-flow inlet duct which produced stator inlet boundary layer flow blockages of 11 percent and 3 percent, respectively. Turbine blade total efficiency at design point was measured to be 5.3 percent greater with the accelerated-flow inlet duct installed due to the reduction in inlet blockage. Blade component measurements show that of this performance improvement, 35 percent occurred in the stator and 65 percent occurred in the rotor. Analysis of inlet duct internal flow using an Axisymmetric Diffuser Duct Code (ADD Code) were in substantial agreement with the test data.

Mclallin, K. L.↗

CARS temperature measurements in a hypersonic propulsion test facility

Static-temperature measurements performed in a reacting vitiated air-hydrogen Mach-2 flow in a duct in Test Cell 2 at NASA LaRC by using a coherent anti-Stokes Raman spectroscopy (CARS) system are discussed. The hypersonic propulsion Test Cell 2 hardware is outlined with emphasis on optical access ports and safety features in the design of the Test Cell. Such design considerations as vibration, noise, contamination from flow field or atmospheric-borne dust, unwanted laser- and electrically-induced combustion, and movement of the sampling volume in the flow are presented. The CARS system is described, and focus is placed on the principle and components of system-to-monochromator signal coupling. Contour plots of scramjet combustor static temperature in a reacting-flow region are presented for three stations, and it is noted that the measurements reveal such features in the flow as maximum temperature near the model wall in the region of the injector footprint.

Jarrett, O., Jr.↗

Application of jet-shear-layer mixing and effervescent atomization to the development of a low-NO(x) combustor

An investigation was conducted to develop appropriate technologies for a low-NO(x), liquid-fueled combustor. The combustor incorporates an effervescent atomizer used to inject fuel into a premixing duct. Only a fraction of the combustion air is used in the premixing process to avoid autoignition and flashback problems. This fuel-rich mixture is introduced into the remaining combustion air by a rapid jet-shear-layer-mixing process involving radial fuel-air jets impinging on axial air jets in the primary combustion zone. Computational analysis was used to provide a better understanding of the fluid dynamics that occur in jet-shear-layer mixing and to facilitate a parametric analysis appropriate to the design of an optimum low-NO(x) combustor. A number of combustor configurations were studied to assess the key combustor technologies and to validate the modeling code. The results from the experimental testing and computational analysis indicate a low-NO(x) potential for the jet-shear-layer combustor. Key parameters found to affect NO(x) emissions are the primary combustion zone fuel-air ratio, the number of axial and radial jets, the aspect ratio and radial location of the axial air jets, and the radial jet inlet hole diameter. Each of these key parameters exhibits a low-NO(x) point from which an optimized combustor was developed. Using the parametric analysis, NO(x) emissions were reduced by a factor of 3 as compared with the emissions from conventional, liquid-fueled combustors operating at cruise conditions. Further development promises even lower NO(x) with high combustion efficiency.

Colantonio, Renato Olaf↗