Search NASA⌕ Search

SEARCH · Search NASA

Results for “alarms”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Search strategy effects on PN acquisition performance

The present paper focusses on 'random' and 'expanding window' PN acquisition search strategies and analytically develops the PN acquisition time statistics as functions of salient system parameters such as prediction SNR, detection and false alarm probabilities and a priori information on epoch location. The significance of this analysis is its general applicability to arbitrary postdetection processing schemes. Computed performance results account for the above salient parameters, wherein sequential detection is employed in conjunction with random and selected expanding window search strategies.

Weinberg, A.↗

Proposed fast-response oxygen monitoring and control system for the Langley 8-foot high-temperature tunnel

A fast-response oxygen monitoring and control system, based on a Y2O3-stabilized ZrO2 sensor, was developed and tested in the laboratory. The system is capable of maintaining oxygen concentration in the CH4-O2-air combustion product gases at 20.9 + or - 1.0 percent. If the oxygen concentration in the exhaust stream differs from that in normal air by 25 percent or more, an alarm signal is provided for automatic tunnel shutdown. The overall prototype system response time was reduced from about 1 sec in the original configuration to about 0.2 sec. The basis of operation and the results of laboratory tests of the system are described.

Singh, J. J.↗

Survey of NASA research on crash dynamics

Ten years of structural crash dynamics research activities conducted on general aviation aircraft by the National Aeronautics and Space Administration (NASA) are described. Thirty-two full-scale crash tests were performed at Langley Research Center, and pertinent data on airframe and seat behavior were obtained. Concurrent with the experimental program, analytical methods were developed to help predict structural behavior during impact. The effects of flight parameters at impact on cabin deceleration pulses at the seat/occupant interface, experimental and analytical correlation of data on load-limiting subfloor and seat configurations, airplane section test results for computer modeling validation, and data from emergency-locator-transmitter (ELT) investigations to determine probable cause of false alarms and nonactivations are assessed. Computer programs which provide designers with analytical methods for predicting accelerations, velocities, and displacements of collapsing structures are also discussed.

Thomson, R. G.↗

Source circuit design considerations

The cost of several circuit configurations for large (5MW) array fields were investigated to assess the relative costs of high and low voltage configurations. Three source circuit NOC voltages were evaluated: 400V (ungrounded), 800V (+ or 400V center grounded), and 2000V (+ or - 1000V center grounded). Four source circuit configurations were considered for each of the three NOC voltages. The configurations correspond to source circuit currents of 15, 30, 45, and 60 amperes, respectively. Conceptual layouts for 5MW building blocks for each of the above configurations were developed. The designs were optimized to minimize BOS electrical and structural costs. Only the BOS electrical costs were evaluated. The designs were broken down into the following elements for cost: (1) basic source circuit intermodule wiring, bypass diodes and associated hardware, source circuit to J-Box wiring, etc; (2) J-Box blocking diodes, varistors, heat sinks, and housing; (3) disconnects source circuit disconnects, fuses, and housing; (4) bus cabling J-Box to PCU interface wiring, and trenching; (5) interface bus bar, group disconnects, and fuses; and (6) fault detection shunts, signal wire, electronics, and alarm. It is concluded that high voltage low current circuits are not economical, at higher currents high and low voltage circuit costs approach each other, high voltage circuits are not likely to offer near term advantage, and development work/manufacturer stimulation is needed to develop low cost high voltage hardware.

Noel, G. T.↗

Fault-tolerant system considerations for a redundant strapdown inertial measurement unit

The development and evaluation of a fault-tolerant system for the Redundant Strapdown Inertial Measurement Unit (RSDIMU) being developed and evaluated by the NASA Langley Research Center was continued. The RSDIMU consists of four two-degree-of-freedom gyros and accelerometers mounted on the faces of a semi-octahedron which can be separated into two halves for damage protection. Compensated and uncompensated fault-tolerant system failure decision algorithms were compared. An algorithm to compensate for sensor noise effects in the fault-tolerant system thresholds was evaluated via simulation. The effects of sensor location and magnitude of the vehicle structural modes on system performance were assessed. A threshold generation algorithm, which incorporates noise compensation and filtered parity equation residuals for structural mode compensation, was evaluated. The effects of the fault-tolerant system on navigational accuracy were also considered. A sensor error parametric study was performed in an attempt to improve the soft failure detection capability without obtaining false alarms. Also examined was an FDI system strategy based on the pairwise comparison of sensor measurements. This strategy has the specific advantage of, in many instances, successfully detecting and isolating up to two simultaneously occurring failures.

Motyka, P.↗

Node synchronization for the Viterbi decoder

At very low signal to noise ratios such as those that Voyager 2 will encounter at Uranus, the performance of the Reed-Solomon/Viterbi concatenated coding system could be seriously degraded by loss of node synchronization by the Viterbi decoder. This problem is described and now it can be almost completely avoided with a simple outboard hardware 'node synchronizer'. This device makes statistical decisions about node sync based on the hard quantized undecoded data stream. In a worst case Voyager-like environment, our method will detect and correct a true loss of node sync (thought to be a very rare event) within several hundred bits; many of these false alarms for our technique is on the order several years. Previously announced in STAR as N83-28028

Lorden, G.↗

Vigilance and task load - In search of the inverted U

The 'Inverted-U Hypothesis' states that for a given task, there is an optimal level of workload or demand that yields the highest level of performance. A departure in either direction will result in a monotonically lower performance level, hence an inverted-U-shaped relationship between task demand and quality of performance. Most studies to date have failed to demonstrate the left-hand branch of the curve, that is, the regime in which performance presumably rises as load increases. The purpose of this study was to explore whether low-level additional demand on the monitor would result in improved performance. Four groups of subjects performed a visual monitoring task for 48 min, then two of the four groups were given additional tasks, and a third had potentially distracting information on its display. Results indicated that the two groups with additional demand detected more signals than did the control group or the control-plus-distraction group. There were no significant differences in false alarms.

Wiener, E. L.↗

Spill-Detector-and-Shutoff Device

Overflow in liquid chromatography systems rapidly detected and stopped. Spill-detector-and-shutoff device incorporated into liquid-chromatography system. When liquid from output nozzle spills on liquid sensor, device automatically shuts off pump and releases solenoid to pinch off flow in tube. Device uses common type of alarm circuit reset manually before normal operation resumes.

Jarvis, M. R.↗

Frequency-Discriminating Acoustic-Event Counter

Broadband events rejected. Acoustic-event counter discriminates against signals that simultaneously exceed preset amplitude thresholds in both low and high-frequency bands of its spectrum. Counter acts as spectral analyzer for mechanical vibrations. In combination with broadband acoustic transducer discriminates between signals and noise in acoustical destructive or nondestructive testing, vibration monitoring for machinery, burglar alarms, and other monitoring/warning systems.

Sugg, F. E.↗

Fast-Response Oxygen-Monitoring and Control System

Oxygen sensor is Y2O3-stabilized ZrO2 ceramic disk maintained at 843 degrees C. Overall system response time reduced to about 0.2 second, equal to or less than 1 percent of tunnel run time. When test gas oxygen concentration differs from normal air concentration by 25 percent or more, alarm sounds, and emergency tunnel shutdown signal operates. New ZrO2 sensors intended for hypersonic-vehicle testing.

Singh, J. J.↗

Flight test configuration for verifying inertial sensor redundancy management techniques

The Redundant Strapdown Inertial Measurement Unit presently tested in flight configuration consists of a semioctahedral array of four dynamically tuned, two-degree-of-freedom (TDOF) gyros and four TDOF accelerometers which can provide dual, fail-operational performance for integrated avionics systems. Attention is given to the multilevel algorithm used for the detection and isolation of three ranges of sensor failure in an integrated avionics context. A technique for the generation of accelerometer and gyro error thresholds which is sensitive to dynamic sensor errors and separation effects is presented, together with simulation results. Emphasis is placed on the ensuring of highly reliable data for flight control/navigation functions, while minimizing false or missed alarms.

Bryant, W. H.↗

A new technique to infer convective rainfall from satellite infrared cloud observations

GLAS-2, a modified version of the GLAS-1 technique developed by Negri et al. (1984) for estimating convective precipitation from GEO-satellite IR data, is introduced and demonstrated on the data set for the Florida Area Cumulus Experiment in 1980. In GLAS-2, rain cells are located by identification of all local blackbody-temperature minima below 253 K in an array of GOES digital data, and rain parameters are assigned on the basis of the one-dimensional cloud model of Adler and Mack (1984). The demonstration results are presented in graphs and tables and compared with those of GLAS-1 and a number of other methods as well as radar and rain-gage measurements. The false-alarm rate for GLAS-2 is found to be 0.54, somewhat better than that of other satellihte methods; further improvements are suggested.

Negri, A. J.↗

Measuring Water-Layer Thickness

Technique uses optical proximity detector. Detector consists of sensing probe, cartridge containing photocell and light source, and electronics package, housed in metal carrying case. Light transmitted from fiber-optic probe reflected by observed surface and transmitted back through probe to photoreceiver, output of which indicated on digital voltmeter or other suitable instrument. Sensor used to detect presence of bubbles or particles in water stream or to trigger alarm when condensing water becomes present in bottom of supposedly dry tank. Fiber-optic probes of sizes up to 0.285 in. (7.24 mm) with varying sensitivities and configurations available for use with system.

Faulcon, N.↗

Operational considerations in monitoring oxygen levels at the National Transonic Facility

Laboratory monitoring of the level of oxygen in sample gas mixtures is a process which can be performed with accurate and repeatable results. Operations at the National Transonic Facility require the storage and pumping of large volumes of liquid nitrogen. To protect against the possibility of a fault resulting in a localized oxygen deficient atmosphere, the facility is equipped with a monitoring system with an array of sensors. During the early operational stages, the system produced recurrent alarms, none of which could be traced to a true oxygen deficiency. A thorough analysis of the system was undertaken with primary emphasis placed on the sensor units. These units sense the partial pressure of oxygen which, after signal conditioning, is presented as a % by volume indication at the system output. It was determined that many of the problems experienced were due to a lack of proper accounting for the partial pressure/% by volume relationship, with a secondary cause being premature sensor failure. Procedures were established to consider atmospherically induced partial pressure variations. Sensor rebuilding techniques were examined, and those elements contributing to premature sensor failure were identified. The system now operates with a high degree of confidence and reliability.

Zalenski, M. A.↗

Ultrasonic Ranging System With Increased Resolution

Master-oscillator frequency increased. Ultrasonic range-measuring system with 0.1-in. resolution provides continuous digital display of four distance readings, each updated four times per second. Four rangefinder modules in system are modified versions of rangefinder used for automatic focusing in commercial series of cameras. Ultrasonic pulses emitted by system innocuous to both people and equipment. Provides economical solutions to such distance-measurement problems as posed by boats approaching docks, truck backing toward loading platform, runway-clearance readout for tail of airplane with high angle attack, or burglar alarm.

Meyer, William E.↗

Testing Long-Term Exposure To Vacuum

Facility for studying long-term effects of vacuum on materials described in report. Vacuum storage system maintains specimens at constant temperature and high vacuum. Enables specimens to be removed easily and safely for analysis. Nitrogen storage system maintains specimens at 77 degree F in pure, dry nitrogen gas under gauge pressure of 2 to 4 psi. Enables comparison of control specimens with specimens exposed to vacuum. Instrumentation-and-control system measures and records operating parameters and generates control signals and alarm indications as necessary.

Clark, D. L.↗

A computer controlled signal preprocessor for laser fringe anemometer applications

The operation of most commercially available laser fringe anemometer (LFA) counter-processors assumes that adjustments are made to the signal processing independent of the computer used for reducing the data acquired. Not only does the researcher desire a record of these parameters attached to the data acquired, but changes in flow conditions generally require that these settings be changed to improve data quality. Because of this limitation, on-line modification of the data acquisition parameters can be difficult and time consuming. A computer-controlled signal preprocessor has been developed which makes possible this optimization of the photomultiplier signal as a normal part of the data acquisition process. It allows computer control of the filter selection, signal gain, and photo-multiplier voltage. The raw signal from the photomultiplier tube is input to the preprocessor which, under the control of a digital computer, filters the signal and amplifies it to an acceptable level. The counter-processor used at Lewis Research Center generates the particle interarrival times, as well as the time-of-flight of the particle through the probe volume. The signal preprocessor allows computer control of the acquisition of these data.Through the preprocessor, the computer also can control the hand shaking signals for the interface between itself and the counter-processor. Finally, the signal preprocessor splits the pedestal from the signal before filtering, and monitors the photo-multiplier dc current, sends a signal proportional to this current to the computer through an analog to digital converter, and provides an alarm if the current exceeds a predefined maximum. Complete drawings and explanations are provided in the text as well as a sample interface program for use with the data acquisition software.

Oberle, Lawrence G.↗

Performance analysis of a generalized upset detection procedure

A general procedure for upset detection in complex systems, called the data block capture and analysis upset monitoring process is described and analyzed. The process consists of repeatedly recording a fixed amount of data from a set of predetermined observation lines of the system being monitored (i.e., capturing a block of data), and then analyzing the captured block in an attempt to determine whether the system is functioning correctly. The algorithm which analyzes the data blocks can be characterized in terms of the amount of time it requires to examine a given length data block to ascertain the existence of features/conditions that have been predetermined to characterize the upset-free behavior of the system. The performance of linear, quadratic, and logarithmic data analysis algorithms is rigorously characterized in terms of three performance measures: (1) the probability of correctly detecting an upset; (2) the expected number of false alarms; and (3) the expected latency in detecting upsets.

Blough, Douglas M.↗