Search NASA⌕ Search

SEARCH · Search NASA

Results for “array detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

SU-F-T-365: Clinical Commissioning of the Monaco Treatment Planning System for the Novalis Tx to Deliver VMAT, SRS and SBRT Treatments

Purpose: To commission the Monaco Treatment Planning System for the Novalis Tx machine. Methods: The commissioning of Monte-Carlo (MC), Collapsed Cone (CC) and electron Monte-Carlo (eMC) beam models was performed through a series of measurements and calculations in medium and in water. In medium measurements relied Octavius 4D QA system with the 1000 SRS detector array for field sizes less than 4 cm × 4 cm and the 1500 detector array for larger field sizes. Heterogeneity corrections were validated using a custom built phantom. Prior to clinical implementation, an end to end testing of a Prostate and H&N VMAT plans was performed. Results: Using a 0.5% uncertainty and 2 mm grid sizes, Tables I and II summarize the MC validation at 6 MV and 18 MV in both medium and water. Tables III and IV show similar comparisons for CC. Using the custom heterogeneity phantom setup of Figure 1 and IGRT guidance summarized in Figure 2, Table V lists the percent pass rate for a 2%, 2 mm gamma criteria at 6 and 18 MV for both MC and CC. The relationship between MC calculations settings of uncertainty and grid size and the gamma passing rate for a prostate and H&N case is shown in Table VI. Table VII lists the results of the eMC calculations compared to measured data for clinically available applicators and Table VIII for small field cutouts. Conclusion: MU calculations using MC are highly sensitive to uncertainty and grid size settings. The difference can be of the order of several per cents. MC is superior to CC for small fields and when using heterogeneity corrections, regardless of field size, making it more suitable for SRS, SBRT and VMAT deliveries. eMC showed good agreement with measurements down to 2 cm − 2 cm field size.

60 APPLIED LIFE SCIENCES↗

R&D of a high-performance DIRC detector for a future electron-ion collider

An Electron-Ion Collider (EIC) is proposed as the next big scientific facility to be built in the United States, costing over $1 billion in design and construction. Each detector concept for the electron/ion beam interaction point is integrated into a large solenoidal magnet. The necessity for excellent hadronic particle identification (pion/kaon/proton) in the barrel region of the solenoid has pushed research and development (R&D) towards a new, high-performance Detection of Internally Reflected Cherenkov light (DIRC) detector design. The passage of a high energy charged particle through a fused silica bar of the DIRC generates optical Cherenkov radiation. A large fraction of this light propagates by total internal reflection to the end of the bar, where the photon trajectories expand in a large volume before reaching a highly segmented photo-detector array. The spatial and temporal distribution of the Cherenkov light at the photo-detector array allows one to reconstruct the angle of emission of the light relative to the incident charged particle track. In order to reach the desired performance of 3sigma pi/K separation at 6 GeV/c particle momentum a new 3-layer spherical lens focusing optic with a lanthanum crown glass central layer was designed to have a nearly at focal plane. In order to validate the EIC DIRC simulation package, a synergistic test beam campaign was carried out in 2015 at the CERN PS with the PANDA Barrel DIRC group using a prototype DIRC detector. Along with the analysis of the CERN test beam data, measurements of the focal plane of the 3-layer lens were performed using a custom-built laser setup at Old Dominion University. Radiation hardness of the lanthanum crown glass was tested using a 160 keV X-ray source and a monochromator at the Catholic University of America. Results of these test-bench experiments and the analysis of the 2015 CERN test beam data are presented here.

43 PARTICLE ACCELERATORS↗

Application of the Rossi-alpha method to simulations of HEU and organic scintillators

The International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook contains thousands of high-quality benchmark measurements that include detailed descriptions of experiment designs and exhaustive accounting of uncertainties. These benchmarks are used extensively by the criticality safety and nuclear data communities. A subcritical benchmark involving bare, highly enriched uranium (HEU) has yet to be accepted to the handbook. The Measurement of Uranium Subcritical and Critical (MUSiC) was proposed to address this gap. MUSiC will be performed at the National Criticality Experiments Research Center (NCERC) and will leverage bare HEU hemisphere shells that can be assembled in a variety of configurations. The measurement has the following key benefits: it will be the first set of fast, subcritical measurements of HEU to be submitted to ICSBEP; ten configurations will be measured spanning from nearly no multiplication to critical (e.g., it is a measurement of similar systems with different re activities); measurements of an all-HEU system will be of value for nuclear data validation, providing results that assist in determining biases in both measurements and simulations. A variety of detector systems will be used including a Neutron Multiplicity Array Detector (NoMAD) system (similar to the MC-15), four small volume 0.635 cm (#8960;) × 7.59 cm 3He detectors (ideal for measuring prompt neutron decay constants due to their fast recovery speed), and an array of eight 5.08 cm (#8960;) × 5.08 cm EJ-309 organic scintillator detectors. The focus of this work is the simulation of the subcritical MUSiC configurations including the EJ-309 detectors and the application of the Rossi-α method. The EJ-309 organic scintillator detector array is a new detection system that will be deployed at NCERC. Organic scintillators are ideal for measurements of fast, subcritical systems due to their short time response on the order of nanoseconds.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-P-49: Comparison of Mapcheck 2 Commission for Photon and Electron Beams

Purpose: We will investigate the performance variation of the MapCheck2 detector array with different array calibration and dose calibration pairs from different radiation therapy machine. Methods: A MapCheck2 detector array was calibrated on 3 Elekta accelerators with different energy of photon (6 MV, 10 MV, 15 MV and 18 MV) and electron (6 MeV, 9 MeV, 12 MeV, 15 MeV, 18 MeV and 20 MeV) beams. Dose calibration was conducted by referring a water phantom measurement following TG-51 protocol and commission data for each accelerator. A 10 cm × 10 cm beam was measured. This measured map was morphed by applying different calibration pairs. Then the difference was quantified by comparing the doses and similarity using gamma analysis of criteria (0.5 %, 0 mm). Profile variation was evaluated on a same dataset with different calibration pairs. The passing rate of an IMRT QA planar dose was calculated by using 3 mm and 3% criteria and compared with respect to each calibration pairs. Results: In this study, a dose variation up to 0.67% for matched photons and 1.0% for electron beams is observed. Differences of flatness and symmetry can be as high as 1% and 0.7% respectively. Gamma analysis shows a passing rate ranging from 34% to 85% for the standard 10 × 10 cm field. Conclusion: Our work demonstrated that a customized array calibration and dose calibration for each machine is preferred to fulfill a high standard patient QA task.

60 APPLIED LIFE SCIENCES↗

Antenna-coupled TES bolometers used in BICEP2, Keck Array, and Spider

We have developed antenna-coupled transition-edge sensor bolometers for a wide range of cosmic microwave background (CMB) polarimetry experiments, including Bicep2, Keck Array, and the balloon borne Spider. These detectors have reached maturity and this paper reports on their design principles, overall performance, and key challenges associated with design and production. Our detector arrays repeatedly produce spectral bands with 20%–30% bandwidth at 95, 150, or 230 GHz. The integrated antenna arrays synthesize symmetric co-aligned beams with controlled side-lobe levels. Cross-polarized response on boresight is typically ∼0.5%, consistent with cross-talk in our multiplexed readout system. End-to-end optical efficiencies in our cameras are routinely 35% or higher, with per detector sensitivities of NET ∼ 300 μK{sub CMB}√s. Thanks to the scalability of this design, we have deployed 2560 detectors as 1280 matched pairs in Keck Array with a combined instantaneous sensitivity of ∼9 μK{sub CMB}√s, as measured directly from CMB maps in the 2013 season. Similar arrays have recently flown in the Spider instrument, and development of this technology is ongoing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CZT Virtual Frisch-grid Detector: Principles and Applications

Cadmium Zinc Telluride (CdZnTe or CZT) is a very attractive material for using as room-temperature semiconductor detectors, because it has a wide bandgap and a high atomic number. However, due to the material's poor hole mobility, several special techniques were developed to ensure its suitability for radiation detection. Among them, the virtual Frisch-grid CZT detector is an attractive option, having a simple configuration, yet delivering an outstanding spectral performance. The goal of our group in Brookhaven National Laboratory (BNL) is to improve the performance of Frisch-ring CZT detectors; most recently, that effort focused on the non-contacting Frisch-ring detector, allowing us to build an inexpensive, large-volume detector array with high energy-resolution and a large effective area. In this paper, the principles of virtual Frisch-grid detectors are described, especially BNL's innovative improvements. The potential applications of virtual Frisch-grid detectors are discussed, and as an example, a hand-held gamma-ray spectrometer using a CZT virtual Frischgrid detector array is introduced, which is a self-contained device with a radiation detector, readout circuit, communication circuit, and high-voltage supply. It has good energy resolution of 1.4% (FWHM of 662-keV peak) with a total detection volume of {approx}20 cm{sup 3}. Such a portable inexpensive device can be used widely in nonproliferation applications, non-destructive detection, radiation imaging, and for homeland security. Extended systems based on the same technology have potential applications in industrial- and nuclear-medical-imaging.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of active interrogation methods for source location in a scattering and absorbing medium, consisting of PGNAA, and an AmBe quasi-forward biased directional source

Source location of Special Nuclear Material (SNM) encompassing 95% 235 U and 239 Pu is identified by utilizing a directional source from Patent No: US20190013109A1 using Prompt Gamma Neutron Activation Analysis (PGNAA) and neutron spectroscopy simulated with Monte-Carlo N-Particle transport 6.2 (MCNP). BC-408, HPGe, LaBr 3 detector arrays were used to identify the location of the SNM using total counts incident on each detector, and PGNAA photopeaks from HPGe and LaBr 3 detector arrays in a polyethylene shield. The conducted simulations varied the volume and location of the SNM in the MCNP input files to observe how the source location method behaved. PGNAA photopeaks used for source identification include 61 keV from fission, 2.223 MeV prompt gamma from hydrogen, 511 keV annihilation, and a single and double escape peaks from the prompt gamma interaction from hydrogen. The capabilities of each detector systems to acquire well resolved photopeaks with a 1% relative error or less, and total relative error for F4 and F8 tallies were less than 0.015% relative error. Source predictions of the SNM with uneven amounts of polyethylene shielding between the source and detectors was observed to overpredict and give invalid source location predictions. Source locations of the SNM with even amounts of polyethylene material between the source and each detector were found to be valid. With a 1 Ci 241 Am source activity, it was determined that 1630 s were needed to obtain the results for each detector system with the quasi-forward directional AmBe source. Coupling source and material identification together would increase acquisition time but would only require one system to determine.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Computed Tomography of Dry Cask Storage for Used Fuel

The demand for dry cask storage for used nuclear fuel is on the rise due to the continuous operation of currently existing nuclear plants which are reaching or have reached the capacity of their used fuel pools. Dry cask storage allows used fuel that has already been cooled in the used fuel pool for at least five years to be surrounded by an inert gas inside a specially designed and licensed cask. Currently, 75 of the 78 U.S.A reactor sites either have or are pursuing an independent spent fuel storage installation (ISFSI) for dry cask fuel storage [1] with over 2,000 casks already loaded [2]. Cask loading will only continue to increase until a final repository solution is operational or the U.S. begins to recycle fuel. The challenge of monitoring the condition of the used fuel inside the cask without exposing the used fuel has been apparent since the 1980s. The objective of the University of Florida (UF) project is ultimately to investigate the feasibility of imaging the used fuel assemblies’ location and evaluating the inner structural condition using emission source computed tomography (CT). A combination of radiation transport models will be used to simulate gamma-rays and neutrons traversing through the used fuel, structure, and cask body materials. In the simulations, multiple linear detector arrays will record the radiation outside the cask wall and will be placed at various angles in order to model rotating a linear detector array around the entire cask. The combination of data from all the detectors will give the planar radiation projection onto the detectors, more commonly called the Radon transform, of the structure of used fuel assemblies. This project can be processed with filtered back projection or other more advanced reconstructive imaging algorithms to recreate the fuel structures. A majority of the historical work done for used fuel has been on verification, diversion detection, and burnup credit validation in order to meet regulatory guidelines. One of the more commonly used systems for single assembly verification is the Fork Detector developed at Los Alamos National Laboratory in 1988 [3]. A group at the Idaho National Laboratory developed a Compton Dry-Cask Imaging Scanner that has the ability to detect empty vs full storage positions but it suffered a setback when transported to the Doel Nuclear Power Plant near Antwerp, Belgium; the system was unable to detect full energy peaks because of the additional scattering caused by a thick ballistic steel shield [4]. As detectors, computational power, and modeling improves, a few groups have leveraged these advancements and started to investigate CT hoping, that despite the difficulties, the technique can give information on fuel condition. So far the groups have mostly limited the tomographic work to a per assembly basis [5] [6] [7], rather than the full dry cask as the University of Florida plans to investigate. The downsides of CT versus simpler verification and validation are the amount of data required and the time it takes to acquire that data. Given that dry casks are intended to sit undistributed for up to 60 years, a scanning time of several weeks to several months is not unreasonable if such systems do not require human operators beyond the initial setup.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Computed Tomography of Dry Cask Storage for Used Fuel

The demand for dry cask storage for used nuclear fuel is on the rise due to the continuous operation of currently existing nuclear plants which are reaching or have reached the capacity of their used fuel pools. Dry cask storage allows used fuel that has already been cooled in the used fuel pool for at least five years to be surrounded by an inert gas inside a specially designed and licensed cask. Currently, 75 of the 78 U.S.A reactor sites either have or are pursuing an independent spent fuel storage installation (ISFSI) for dry cask fuel storage with over 2,000 casks already loaded. Cask loading will only continue to increase until a final repository solution is operational or the U.S. begins to recycle fuel. The challenge of monitoring the condition of the used fuel inside the cask without exposing the used fuel has been apparent since the 1980's. The objective of the University of Florida (UF) project is ultimately to investigate the feasibility of imaging the used fuel assemblies' location and evaluating the inner structural condition using emission source computed tomography (CT). A combination of radiation transport models will be used to simulate gamma-rays and neutrons traversing through the used fuel, structure, and cask body materials. In the simulations, multiple linear detector arrays will record the radiation outside the cask wall and will be placed at various angles in order to model rotating a linear detector array around the entire cask. The combination of data from all the detectors will give the planar radiation projection onto the detectors, more commonly called the Radon transform, of the structure of used fuel assemblies. This project can be processed with filtered back projection or other more advanced reconstructive imaging algorithms to recreate the fuel structures. A majority of the historical work done for used fuel has been on verification, diversion detection, and burnup credit validation in order to meet regulatory guidelines. One of the more commonly used systems for single assembly verification is the Fork Detector developed at Los Alamos National Laboratory in 1988. A group at the Idaho National Laboratory developed a Compton Dry-Cask Imaging Scanner that has the ability to detect empty vs full storage positions but it suffered a setback when transported to the Doel Nuclear Power Plant near Antwerp, Belgium; the system was unable to detect full energy peaks because of the additional scattering caused by a thick ballistic steel shield. As detectors, computational power, and modeling improves, a few groups have leveraged these advancements and started to investigate CT hoping, that despite the difficulties, the technique can give information on fuel condition. So far the groups have mostly limited the tomographic work to a per assembly basis , rather than the full dry cask as the University of Florida plans to investigate. The downsides of CT versus simpler verification and validation are the amount of data required and the time it takes to acquire that data. Given that dry casks are intended to sit undistributed for up to 60 years, a scanning time of several weeks to several months is not unreasonable if such systems do not require human operators beyond the initial setup. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Dosimetric validation of a commercial Monte Carlo based IMRT planning system

Purpose: Recently a commercial Monte Carlo based IMRT planning system (Monaco version 1.0.0) was released. In this study the dosimetric accuracy of this new planning system was validated. Methods: Absolute dose profiles, depth dose curves, and output factors calculated by Monaco were compared with measurements in a water phantom. Different static on-axis and off-axis fields were tested at various source-skin distances for 6, 10, and 18 MV photon beams. Four clinical IMRT plans were evaluated in a water phantom using a linear diode detector array and another six IMRT plans for different tumor sites in solid water using a 2D detector array. In order to evaluate the accuracy of the dose engine near tissue inhomogeneities absolute dose distributions were measured with Gafchromic EBT film in an inhomogeneous slab phantom. For an end-to-end test a four-field IMRT plan was applied to an anthropomorphic lung phantom with a simulated tumor peripherally located in the right lung. Gafchromic EBT film, placed in and around the tumor area, was used to evaluate the dose distribution. Results: Generally, the measured and the calculated dose distributions agreed within 2% dose difference or 2 mm distance-to-agreement. But mainly at interfaces with bone, some larger dose differences could be observed. Conclusions: Based on the results of this study, the authors concluded that the dosimetric accuracy of Monaco is adequate for clinical introduction.

61 RADIATION PROTECTION AND DOSIMETRY↗

Design and validation of a cold load for characterization of cosmic microwave background stage 4 detectors

We present the design and validation of a variable temperature cryogenic blackbody source, hereinafter called a cold load, that will be used to characterize detectors to be deployed by cosmic microwave background stage 4 (CMB-S4), the next-generation ground-based cosmic microwave background (CMB) experiment. Although cold loads have been used for detector characterization by previous CMB experiments, this cold load has three innovative design features: (1) the ability to operate from the 1-K stage of a dilution refrigerator (DR), (2) a He3 gas-gap heat switch to reduce cooling time, and (3) the ability to couple small external optical signals to measure detector optical time constants under low optical loading. The efficacy of this design was validated using a 150-GHz detector array previously deployed by the Spider experiment. Thermal tests showed that the cold load can be heated to temperatures required for characterizing CMB-S4’s detectors without significantly impacting the temperatures of other cryogenic stages when mounted to the DR’s 1-K stage. In addition, optical tests demonstrated that external signals can be coupled to a detector array through the cold load without imparting a significant optical load on the detectors, which will enable measurements of the CMB-S4 detectors’ optical time constants.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Combining {gamma}-ray and particle spectroscopy in Cologne

To gain additional information on nuclear structure, the new silicon-detector array SONIC, consisting of up to eight {Delta}E-E telescopes, was installed inside the existing HPGe-detector array HORUS in Cologne. Its main purpose is the study of inelastic scattering using p-, d- and {alpha}-beams of a 10 MV Tandem accelerator. The array has already been tested with two experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The New Maia Detector System: Methods For High Definition Trace Element Imaging Of Natural Material

Motivated by the need for megapixel high definition trace element imaging to capture intricate detail in natural material, together with faster acquisition and improved counting statistics in elemental imaging, a large energy-dispersive detector array called Maia has been developed by CSIRO and BNL for SXRF imaging on the XFM beamline at the Australian Synchrotron. A 96 detector prototype demonstrated the capacity of the system for real-time deconvolution of complex spectral data using an embedded implementation of the Dynamic Analysis method and acquiring highly detailed images up to 77 M pixels spanning large areas of complex mineral sample sections.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fuel Cycle Research & Development Technical Monthly – May 2012

Management and Integration LANL - Initial coordination meetings with NE and NA-20 were held the first week of May. Additional meetings, to include NA-82 and the new Proliferation and Terrorism Risk Assessment task are scheduled for June. Work package planning as part of the NTD transition is ongoing. Microcalorimetry LANL - Some parts to attempt repair of a malfunctioning water chiller that has been holding up work on the current detector array have arrived. We will attempt to begin running the compressor/cryostat next week to resume work on commissioning the detector array. We have also been working on a backup plan to temporarily move our system to a different lab space. Completed data analysis and prepared a paper summarizing Pu measurements for peer-review journal. Two members of our team presented work at the SORMA West 2012 conference. Completed data analysis and prepared a milestone report summarizing the development of Monte Carlo tools to study systematic errors. Electrochemical Sensor INL - The second sensor test was stopped short due to the work stand-down. Some activities related to this work have resumed, but not all. The sensor used during the second test was removed from the furnace and it showed cracks and later crumbled when being rinsed for sample preparation. The sensor material will be submitted to SEM analysis once work is resumed in the facilities where analysis is performed. A third sensor test has started. Tests with different arrangements will continue and will be oriented based on post-test analysis of the first three sensor tests. Materials with different annealing temperatures will also be prepared for analysis. Lead slowing down spectrometer LANL - Continued work on perturbation method for LSDS analysis. We are running simulations to delineate issues and are checking additional data libraries to see whether there are differences in simulation results. Electrochemical sensor INL - The second sensor test was stopped short due to the work stand-down. Some activities related to this work have resumed, but not all. The sensor used during the second test was removed from the furnace and it showed cracks and later crumbled when being rinsed for sample preparation. The sensor material will be submitted to SEM analysis once work is resumed in the facilities where analysis is performed. A third sensor test has started. Tests with different arrangements will continue and will be oriented based on post-test analysis of the first three sensor tests. Materials with different annealing temperatures will also be prepared for analysis. Fast Neutron Multiplicity analysis INL - The University of Michigan team continues its work on the post-experiment analysis of the validation data from JRC ISPRA, as well as scoping studies using the simulation tool MCNPX-PoliMi. At INL, our new staff member working on this project is now working to model performance capabilities for the fast-neutrons scintillator design concepts. At INL our primary analysis approach is focused on the Feynman mean-to-variance approach. At the University of Michigan, the primary analysis approach is multiplicity coincidence analysis. Fast Neutron Imaging to Quantify Nuclear Materials ORNL - Completed additional measurements of the two 'trainer' configurations as well as calibration measurements with sources on an x-y stage. The imager was shipped to Pantex for an NA-22 obligation at the end of May. Lead Slowing Down Spectrometer LANL - Continued to look into He4 detector. A Swiss company was located that makes He4 detectors and associated electronics. Had a teleconference with them to assess the possible help we can get from them. We are also looking in to constructing one locally. Ongoing perturbation calculations are providing information on the fundamental systematic error limits of LSDS. In order to achieve separating the contribution of Pu and 235U to the signal, there will need to be tight controls on systematic errors. Multi-isotope Process Monitor PNNL - Attended a training call in advanced multivariate classification and analysis methods. These methods were applied to the multivariate analysis of fuel characteristics based on simulated gamma. Work continued on a computational framework to quantify the impact of gamma-ray counting statistical precision on principal component regression (PCR) analysis of a multi-component (i.e. multi-isotope) gammaray spectrum. Tests of the simulation framework are anticipated to begin in early June. Development of a proposal to instrument H-Canyon is being prepared in conjunction with SRNL and the NNSA's NGSI program is ongoing.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Calibration of a novel four-dimensional diode array

Purpose: The aim of this work is to develop effective calibration methods for a novel four-dimensional (4D) diode array for pretreatment verification of intensity-modulated radiation therapy (IMRT) and rotational therapy. Methods: A novel 4D diode array (ArcCHECK, Sun Nuclear, Melbourne, FL) was developed to meet the needs of appropriate and efficient quality assurance for IMRT and especially rotational radiotherapy. The diode array presents a consistent detector image in beam's eye view at arbitrary gantry angles due to isotropic arrangement of diodes in a three-dimensional (3D) cylindrical phantom. The 50 ms simultaneous update of all diodes on the detector array (fourth dimension) makes it capable of time-resolved beam delivery analysis with any rotational delivery techniques. The calibration procedure consisted of delivering and measuring a series of calibration beams with 5.8 deg. angular spacing surrounding the cylindrical diode array. Correction factors for diode intrinsic sensitivity and directional response dependence were derived from these measurements. A real-time algorithm to derive gantry angles based on the detector signal was developed to interpolate and apply the corresponding angular correction factors. Results: The calibration was validated with ion chamber scanned beam profiles in a 3D water tank. Excellent agreement was observed between diode array measurement and treatment planning system calculation. The accuracy of the gantry angle derivation algorithm was within 1 deg. which caused a less than 0.2% dosimetric uncertainty. Conclusions: With the proposed calibration method and the automatic gantry angle derivation algorithm, the 4D diode array achieved isotropic detector response and is suitable for both IMRT and rotational therapy pretreatment verification.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Shell structure in neutron rich nuclei by means of binary reactions

Nuclear structure studies far from stability rely mainly on the availability of radioactive nuclear beams but can complementary be addressed by means of high intensity beams of stable ions. In such contest, deep-inelastic and multinucleon transfer reactions are a powerful tool to populate yrast and non yrast states in neutron-rich nuclei. Particularly successful is here the combination of large acceptance spectrometers with highly segmented gamma-detector arrays. Such devices can provide the necessary channel selectivity to identify very rare signals. The AGATA gamma-ray detector array coupled to the PRISMA spectrometer at the Legnaro National Laboratories (LNL) in Italy is one example. Large data sets have been collected at LNL for nuclei close to the N=20, 28, 40, 50 and 82 shell closures.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Instrument Control Software for Spectrophotometers

SRNL has developed instrument control software for diode array spectrophotometers that can be used for real time monitoring of dynamic systems. This software has evolved through several iterations as instruments have been developed for use in processing facilities at Savannah River Site. There are several noteworthy features of the software. The wavelength calibration is checked and updated in real time against reference emission lines that are designed into the instrument light source. Nonlinearities and offsets associated with the intensity response of the instruments are characterized, and absorbance spectra are appropriately corrected. These actions are necessary for accurate calculation of an absorbance spectrum from the intensity responses of two individual diode array detectors. The corrections also result in the spectra obtained for a particular sample by two (or more) different diode array detector pairs being nearly identical. This property assures consistent measurements at multiple locations with different instruments. It also permits the use of a single analyte calibration across many instruments without modification and without loss of accuracy

47 OTHER INSTRUMENTATION↗

Lateral distribution of pulse height in a parallel-plate avalanche counter

The nuclear γ-ray spectroscopy enters a new era when the first engineering run of GRETINA [1], a new generation of γ-ray tracking arrays, was successfully carried out at LBNL in early April, 2011. A parallel effort has been setup to develop the auxiliary charged-particle detector arrays with a matching position resolution to fully exploit the potential of GRETINA. Improving the position resolution of the existing charged-particle detector array, CHICO [2], is a part of this coordinated effort. The proposal to upgrade CHICO was approved by DOE/SC at the end of FY10. The goal is to redesign the cathode board and amplifier to improve the resolution for both and coordinates to better than one degree to match that of GRETINA. This project is scheduled to complete by the summer of 2012.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗