Search NASA⌕ Search

SEARCH · Search NASA

Results for “artifacts”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Circadian rhythmometry of mammalian radiosensitivity

In the case of human bone marrow, the largest number of mitoses is seen in the evening in diurnally active men, mitotic activity being at a minimum in the morning. The opposite pattern is observed for nocturnal animals such as rats and mice on a regimen of light during the daytime alternating with darkness during the night hours. The entirety of these rhythms plays an important role in the organism's responses to environmental stimuli, including its resistance to potentially harmful agents. Conditions under which circadian rhythms can be observed and validated by inferential statistical means are discussed while emphasizing how artifacts of the laboratory environment can be shown to obscure circadian periodic variations in radiosensitivity.

Haus, E.↗

Breadboard linear array scan imager using LSI solid-state technology

The performance of large scale integration photodiode arrays in a linear array scan (pushbroom) breadboard was evaluated for application to multispectral remote sensing of the earth's resources. The technical approach, implementation, and test results of the program are described. Several self scanned linear array visible photodetector focal plane arrays were fabricated and evaluated in an optical bench configuration. A 1728-detector array operating in four bands (0.5 - 1.1 micrometer) was evaluated for noise, spectral response, dynamic range, crosstalk, MTF, noise equivalent irradiance, linearity, and image quality. Other results include image artifact data, temporal characteristics, radiometric accuracy, calibration experience, chip alignment, and array fabrication experience. Special studies and experimentation were included in long array fabrication and real-time image processing for low-cost ground stations, including the use of computer image processing. High quality images were produced and all objectives of the program were attained.

Tracy, R. A.↗

Reexamination of the correlation of galaxies and QSO's

It is shown that the correlation of the separation in the sky between certain QSO's and the nearest bright galaxy to them with the galaxy's redshift could be an artifact of the sampling procedure or small number statistics. The overall association between 3C QSO's and bright galaxies remains as suggestive, but not compelling, evidence for a physical relationship.

Noerdlinger, P. D.↗

Applied photo interpretation for airbrush cartography

New techniques of cartographic portrayal have been developed for the compilation of maps of lunar and planetary surfaces. Conventional photo interpretation methods utilizing size, shape, shadow, tone, pattern, and texture are applied to computer processed satellite television images. The variety of the image data allows the illustrator to interpret image details by inter-comparison and intra-comparison of photographs. Comparative judgements are affected by illumination, resolution, variations in surface coloration, and transmission or processing artifacts. The validity of the interpretation process is tested by making a representational drawing by an airbrush portrayal technique. Production controls insure the consistency of a map series. Photo interpretive cartographic portrayal skills are used to prepare two kinds of map series and are adaptable to map products of different kinds and purposes.

Inge, J. L.↗

Applied photo interpretation for airbrush cartography

Lunar and planetary exploration has required the development of new techniques of cartographic portrayal. Conventional photo-interpretive methods employing size, shape, shadow, tone, pattern, and texture are applied to computer-processed satellite television images. Comparative judgements are affected by illumination, resolution, variations in surface coloration, and transmission or processing artifacts. The portrayal of tonal densities in a relief illustration is performed using a unique airbrush technique derived from hill-shading of contour maps. The control of tone and line quality is essential because the mid-gray to dark tone densities must be finalized prior to the addition of highlights to the drawing. This is done with an electric eraser until the drawing is completed. The drawing density is controlled with a reflectance-reading densitometer to meet certain density guidelines. The versatility of planetary photo-interpretive methods for airbrushed map portrayals is demonstrated by the application of these techniques to the synthesis of nonrelief data.

Inge, J. L.↗

Implantable electrode for recording nerve signals in awake animals

An implantable electrode assembly consisting of collagen and metallic electrodes was constructed to measure simultaneously neural signals from the intact nerve and bioelectrical noises in awake animals. Mechanical artifacts, due to bodily movement, were negligibly small. The impedance of the collagen electrodes, measured in awake cats 6-7 days after implantation surgery, ranged from 39.8-11.5 k ohms at a frequency range of 20-5 kHz. Aortic nerve activity and renal nerve activity, measured in awake conditions using the collagen electrode, showed grouped activity synchronous with the cardiac cycle. Results indicate that most of the renal nerve activity was from postganglionic sympathetic fibers and was inhibited by the baroceptor reflex in the same cardiac cycle.

Ninomiya, I.↗

Measurements of radon concentrations in the lunar atmosphere

The radon concentrations in the lunar atmosphere were determined by measuring the Po-210 progeny activity in artifacts returned from the moon. Experiments performed on a section of the polished aluminum strut from Surveyor 3 and data obtained from the Apollo 16 Cosmic Ray Detector Experiment Teflon thermal shield are compared with other values of the lunar radon concentration obtained at different times and different locations and by various techniques. Possible sources and release mechanisms compatible with all of the data are discussed. An experimental procedure to determine the relative retention coefficients of various types of material for radon progeny in a simulated lunar environment is described. The results of several experiments are given, and their effect on lunar radon progeny measurements is discussed. An analytical procedure is given for the analysis of a Teflon matrix for trace constituents.

Brodzinski, R. L.↗

Variable threshold zonal filtering

Variable threshold zonal filtering is an active nonlinear image enhancement technique designed to avoid ringing artifacts which filtering can introduce near sharp brightness transitions in the original scene. The filtering procedure can be implemented in the Fourier domain or by subtractive box filtering. It is shown, in reference to a Landsat scene of Iceland, that while conventional box filtering produces severe ringing, zonal filtering results in a more uniform display of local detail.

Schwartz, A. A.↗

An electrode system for tetrapolar electrical impedance plethysmography of the finger

A rigid band electrode system is described which facilitates location of the recording electrodes of a tetrapolar impedance plethysmograph used for measuring pulsations of blood in a finger segment. The electrodes can be relocated accurately, and the volume of the finger segment under study can be precisely defined. The new system ensures good electrical contact and minimizes movement artifacts in the plethysmograph trace by holding the finger segment in a firm position.

Montgomery, L. D.↗

Thermal shock and erosion resistant tantalum carbide ceramic material

Ceramic tantalum carbide artifacts with high thermal shock and mechanical erosion resistance are provided by incorporating tungsten-rhenium and carbon particles in a tantalum carbide matrix. The mix is sintered by hot pressing to form the ceramic article which has a high fracture strength relative to its elastic modulus and thus has an improved thermal shock and mechanical erosion resistance. The tantalum carbide is preferable less than minus 100 mesh, the carbon particles are preferable less than minus 100 mesh, and the tungsten-rhenium particles are preferable elongate, having a length to thickness ratio of at least 2/1. Tungsten-rhenium wire pieces are suitable as well as graphite particles.

Honeycutt, L., III↗

Class of near-perfect coded apertures

Coded aperture imaging of gamma ray sources has long promised an improvement in the sensitivity of various detector systems. The promise has remained largely unfulfilled, however, for either one of two reasons. First, the encoding/decoding method produces artifacts, which even in the absence of quantum noise, restrict the quality of the reconstructed image. This is true of most correlation-type methods. Second, if the decoding procedure is of the deconvolution variety, small terms in the transfer function of the aperture can lead to excessive noise in the reconstructed image. It is proposed to circumvent both of these problems by use of a uniformly redundant array (URA) as the coded aperture in conjunction with a special correlation decoding method.

Cannon, T. M.↗

Calibration and performance of the Viking lander cameras

The paper discusses Viking lander cameras which have an angular resolution of 0.12 deg, and (for broadband imaging) a resolution of 0.04 deg, used for the acquisition of data in six spectral bands for color and near-infrared imaging. Attention is given to photogrammetric calibration techniques used in the determination of spatial and spectral brightness variations from image data. The effects of sampling on the achievable photogrammetric precision are described along with techniques for preflight spectral calibrations and the corrections required for degradation in the infrared response of the detectors. The effects of the known internal reflections on the qualitative images (such as the appearance of artifact clouds) are presented, noting their effects on skyline radiometry. The qualitative and quantitative effects of the signal quantization are briefly reviewed.

Patterson, W. R., III↗

Effect of foam age on toxicity of pyrolysis gases from polyurethane flexible foams

The toxicity of the pyrolysis gases from some samples of polyurethane flexible foams appears to have decreased with age, while other samples seem to exhibit no significant change with age in this respect. The changes observed were greater than could be accounted for by variations in the material, or test variations or artifacts.

Hilado, C. J.↗

A long-range and long-life telemetry data-acquisition system for heart rate and multiple body temperatures from free-ranging animals

The system includes an implantable transmitter, external receiver-retransmitter collar, and a microprocessor-controlled demodulator. The size of the implant is suitable for animals with body weights of a few kilograms or more; further size reduction of the implant is possible. The ECG is sensed by electrodes designed for internal telemetry and to reduce movement artifacts. The R-wave characteristics are then specifically selected to trigger a short radio frequency pulse. Temperatures are sensed at desired locations by thermistors and then, based on a heartbeat counter, transmitted intermittently via pulse interval modulation. This modulation scheme includes first and last calibration intervals for a reference by ratios with the temperature intervals to achieve good accuracy even over long periods. Pulse duration and pulse sequencing are used to discriminate between heart rate and temperature pulses as well as RF interference.

Lund, G. F.↗

Smoke density studies with the Arapahoe and NBS chambers

Smoke density studies on twelve cellulosic and five synthetic materials using the Arapahoe and NBS smoke chambers show an empirical relationship between smoke weight as per cent of initial weight in the Arapahoe test and maximum specific optical density under piloted conditions in the NBS test. The NBS optical density data under piloted conditions exhibited sensitivity to test artifacts such as type of pilot burner.

Hilado, C. J.↗

Does the emission measure decrease during the start of a soft X-ray flare

It is suggested that the apparent emission dip found in soft X-ray flare observations, interpreted as the emission from a single temperature plasma, is an artifact. According to this hypothesis, the flare phenomenon represents a combination of flare plus a stable active region plasma. A small amount of hot flare plasma will dominate the total emission, and the calculated isothermal plasma parameters will trend towards those of the hot flare plasma, so that a decrease in emission measure will be inferred. It is claimed that observed data fit the model of a stable plasma plus a flare plasma better than it does the model of a single plasma, in accordance with a chi square statistic. The model of stable plasma plus flare plasma is also supported by the observation that the plasma parameters in the postflare condition are indistinguishable from those during preflare.

Wolfson, C. J.↗

Beta-galactosidase and selective neutrality

Three hypotheses to explain the amino acid composition of proteins are inconsistent (about 10 to the minus 9th) with the experimental data for beta-galactosidase from Escherichia coli. The exceptional length of this protein, 1021 residues, permits rigorous tests of these hypotheses without complication from statistical artifacts. Either this protein is not at compositional equilibrium, which is unlikely from knowledge about other proteins, or the evolution of this protein and its coding gene have not been selectively neutral. However, the composition of approximately 60% of the molecule is consistent with either a selectively neutral or nonneutral evolutionary process.

Holmquist, R.↗

Weight control and restraint of laboratory rats

The use of restrained and confined rats in some procedures used in combustion toxicology introduces the problems of obtaining rats of the appropriate size for the apparatus, and of identifying any artifacts resulting from the use of restraint alone. Feeding studies indicate that controlled feeding of fast-growing strains such as the Sprague-Dawley can hold rat size essentially constant for significant periods of time. The undesirable aspects are the need to cage the animals individually, with resultant psychological as well as metabolic effects. Restraint studies of slow-growing strains such as the Fischer 344 indicate that denying access to food and water for periods of several hours at a time interrupts normal gain only temporarily.

Hilado, C. J.↗