Search NASA⌕ Search

SEARCH · Search NASA

Results for “astromaterial”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Atom Probe Tomography and Three-Dimensional Atomic Scale Characterisation of Interplanetary Dust Particles: Inorganic and Organic, Hydrous and Anhydrous Assemblages

Interplanetary dust particles (IDPs)preserve primordial fragments from our Solar System and external stellar systems, sampled from a vast range of dust forming bodies that often display smaller degrees of parent body processing than is seen in meteorites. IDPs preserve some of the smallest astromaterials from our Solar System, many of which are believed to be among the most important materials for studying physical and chemical processing, and formation mechanisms occurring within the interstellar medium (ISM), Solar Nebula and external planetary systems[1]. However, their formation processes and provenance are poorly constrained, owing in part to spatial resolution limitations of traditional analytical techniques. Atom probe tomography (APT) uses a pulsed laser to field-evaporate material at the atomic scale from needle-shaped samples, and time-of-flight spectrometry for 3D reconstruction of element and isotope distribution in samples after data acquisition. This technique has the highest spatial resolution available of any technique used within the geoscience field[2]. However, measuring multi-phase specimens and porous media in APT can be challenging, two primary characteristics of IDPs. Here we present a custom method for APT needle design and the first results of a 3Datomic scale study of interplanetary dust particles, salt crystals and extraterrestrial insoluble and soluble organic matter designed to overcome the challenges of studying IDP-like materials.

N D Nevill↗

Microbial Bioburden on NASA Cleanroom Surfaces: Cell Counting and Fluorescence in situ Hybridization

Spacecraft assembly cleanrooms can harbor a low number of microbial cells that could contaminate hardware designed for life detection missions (known as “bioburden”). We are evaluating epifluorescence microscopy and fluorescence in situ hybridization (FISH) as rapid, accurate, and cost-effective methods to complement other contamination detection techniques. This study is part of a larger effort to characterize background organic contamination and the efficacy of cleaning procedures in Johnson Space Center (JSC) Astromaterials Curation Laboratories and Goddard Space Flight Center (GSFC) spacecraft assembly rooms. The low level of biomass required careful use of blanks during each stage of sample collection and preparation. FISH was performed using general archaeal and bacterial probes, as well as some group-specific probes. While some active bacteria were identified, a large majority of them were dead or inactive, and thus were difficult to identify by standard FISH. Our results are consistent with other studies that show that the bioburden present in clean rooms includes active, dormant, and dead cells.

C J Huff↗

Center for Isotope Cosmochemistry and Geochronology at NASA Johnson Space Center

The Center for Isotope Cosmochemistry and Geochronology (CICG) at the NASA Johnson Space Center, led by Justin Simon, applies novel elemental and isotopic analytical techniques to understand solar system formation, from processes occurring during the earliest Solar Nebula, to the evolution of planetary bodies during planet formation and differentiation. CICG consists of an integrated suite of labs including dedicated spaces for specialized handling and preparation of meteorites and planetary return samples, metal-free clean chemistry, and mass spectrometry. In addition to a Thermo-Scientific Triton thermal ionization mass spectrometer (TIMS) for high precision isotopic analyses in processed samples, CICG houses two additional mass spectrometry instruments with added laser ablation capabilities for high spatial resolution in-situ measurements: (1) a Thermo-Scientific Element-XR inductively coupled mass spectrometer (ICP-MS) with a Teledyne Photon Machines Analyte Excite+ laser ablation system, and (2) a Nu Sapphire 1700 multi-collector ICP-MS, a large geometry instrument with a multi-pole collision cell for interference removal, with an Applied Spectra J200 tandem laser induced breakdown spectroscopy (LIBS) femto-second laser ablation system. We detail the analytical capabilities of CICG in the context of current and future research projects related to the studies of protoplanetary disk evolution via early-formed Solar System solids, volatile abundances and distribution within the inner solar system, and geochemical and temporal investigations related to planet formation and differentiation. We also highlight opportunities through the relationship with the Center of the Advancement of Space Safety and Mission Assurance Research (CASSMAR) at the University of Texas at El Paso. CICG is open to collaborations and participates in the NASA Facility for Astromaterials Research (NFAR) program, which accepts research proposals for access to the unique facility capabilities.

Jacob B. Setera↗

Results of the Preliminary Analysis of Asteroid Ryugu Regolith Samples Returned by the Hayabusa2 Mission

As an example of the range of measurements now made for special astromaterials, this paper briefly summarizes the results of recent analyses of samples from asteroid 162173 Ryugu. The JAXA Hayabusa2 spacecraft returned 5.5g of regolith material from Ryugu on December 5, 2020 to the Woomera Range, Australia. Six preliminary sample analysis teams consisting of over 200 scientists worldwide measured the basic characteristics of the returned samples, revealing the basic history of asteroid Ryugu.

Asteroids↗

XRF Characterization of MMOD Impact Damage

Introduction The Hypervelocity Impact Technology (HVIT) Group at the NASA Johnson Space Center (JSC) has performed over 150 post flight MMOD inspections on returned space-ex-posed hardware and collected over 1,600 samples. Determination of the impactor source typically requires an analysis of the projectile residue in the damage feature. At this time, about 20% of the samples have been processed. Types of Samples Samples in the HVIT group collection can be classified into two types. Indirect (non-destructive) samples are produced when a pliable material (e.g., adhesive tape or dental mold) is inserted into an impact feature. With this type of sampling technique, crater material and (hopefully) projectile residue material is embedded in the sample media and can detected using further chemical characterizing techniques. Direct (destructive) sampling involves the in-tact extraction of material from the spacecraft and is done in a manner that the entire impact feature can be excised intact. This technique provides the greatest chance of successfully determining impactor source due to the entirety of the projectile remnants being present within the collected sample. Updated Projectile Residue Detection Techniques Previous assessments of projectile provenance have involved the use of samples that are first mounted in epoxy, sectioned to expose the crater interior, imaged with a scanning electron microscope (SEM), then any observed impactor residue was then analyzed using an energy dispersive spectrometer (EDS). This technique, while proven, may be supplemented with other types of elemental analysis techniques that can observe major element chemistry, in order to improve throughput of sample analysis. The Astromaterials Research and Exploration Science (ARES) Division at JSC, for example, operates a Bruker M4 Tornado micro-X-Ray fluorescence (XRF) spectrometer, capable of creating elemental maps of areas around these small impact features in a couple of hours, with a spot size <20 μm. The potential advantage with this technique lies in sample preparation, as no polishing or conductive coatings are needed. Early trials attempted to deter-mine impactor composition by collecting spectra from intact samples by aiming the X-Rays directly into the impact feature, but the signal:noise ratio was too low for confident material identification. Sample preparation for XRF then relies on sectioning the samples parallel to the impactor trajectory in order to expose the largest area of subsurface damage possible, thus maximizing the signal from any small impactor remnants. Complementary to the use of XRF for sample analysis, ARES also houses a Nikon XTH 320 micro-X-Ray computed tomography (XCT). This instrument can be used to create 3D visualizations of impact damage for the determination of crater volumes and dimensions, as well as for the determination of the best place to section each sample for the subsequent XRF analysis.

J L Hyde↗

Characterization Of Early Solar System Aqueous Fluids

The most direct and convincing evidence for the presence of water and organic molecules on protoplanetary bodies is provided by fluid inclusions trapped in secondary minerals. Our research has demonstrated that early solar system fluids have survived as fluid inclusions in a few astromaterials that escaped significant shock, terrestrial alteration, and invasive sample handling. Our long-term goal is to measure bulk molecular and isotopic composition of individual fluid inclusions in meteorites and samples collected directly from asteroids to provide ground truth regarding the nature and evolution of aqueous fluids in the early solar system. Our current protocol is to locate candidate fluid inclusions using X-Ray Computed Tomography, and then make compositional measurements of individual fluid inclusions by coordinated Raman spectrometry, Transmission Electron Microscopy and, most recently, Time of Flight – Secondary Ion Mass Spectrometry.

Michael Zolensky↗

Application of Long-Path Gas Cell Assisted Infrared Spectroscopy for Detection of Lunar Volatiles and Advanced Curation Efforts

The motivation behind analyzing gaseous samples from the Permanently Shadowed Regions (PSRs) on the lunar surface is built upon the volatiles observed during the LCROSS mission. Advanced curation techniques under cold conditions are essential to the critical scientific analysis of these returned samples. The detection of various volatiles in returned samples by gas-phase infrared (IR) spectroscopy is known to be a powerful tool to understand the resources present in planetary bodies and Astro-materials. The identification and quantification of volatile compounds in returned planetary samples and regolith simulants by advanced and custom-built analytical devices are areas of primary research interest in our group and the Planetary Exploration & Astromaterials Research Laboratory (PEARL) facility. In this context, we discuss recent advancements and experimental results for quick analysis of the major volatiles detected by the LCROSS (water, CO 2 , CH 3 OH, and NH 3 ) by a long-path gas cell/FTIR (Fourier Transform Infrared) spectrometer system. The applicability of this system is demonstrated by qualitative analysis of a series of volatiles measured individually. In addition, the linear dependence of absorption intensity on headspace sample volumes was checked by measuring gas-phase IR absorption spectra of increasing volumes of pure CO 2 gas aliquots. Finally, the instrument performance was evaluated by measuring the relative concentration of NH 3 (g) in methanol solution.

Curation↗

Qualitative Headspace GCMS Analysis of Lunar Regolith and Volatile Simulant Mixtures

Introduction: Future Artemis missions aim to return the volatile-bearing samples collected near lunar polar craters. We, as advanced curation scientists, are responsible for developing techniques and methodologies for preserving the integrity of returned samples and the science value those samples contain. The extent to which that preservation is possible, and the trade-offs preservation requires (e.g. monetary costs, sample volume limitations) all must be considered. Even less-than pristine volatile-bearing samples will be of tremendous value to the scientific community seeking to unravel the history of lunar surface volatiles and, more broadly, volatiles in the solar system. A sample collected on the lunar surface will experience at least five distinctive periods during which any changes here referred to as “alteration” will certainly occur at some scale: collection on the lunar surface; transportation back to Earth; long-term storage; curatorial processing; and allocation/distribution. The Planetary Exploration and Astromaterials Research Lab (PEARL) seeks to understand temperature and pressure effects on returned volatile samples by working with high-fidelity volatile-containing regolith simulants, setting the foundation for the future of cold curation. This abstract is focused on gas-surface interactions between LCROSS volatiles and readily available lunar regolith simulants. Experiments involved analyzing differences in headspace gas composition for various combinations of volatile and regolith simulants using gas chromatography/mass spectrometry (GC/MS). Experimental Procedure: The volatile simulants were chosen based on the molecules detected during the LCROSS mission.1 Stock solutions of condensed lunar volatile analytes were: methanol, 7 N ammonia in methanol, and 0.4% hydrogen sulfide in water. The regolith simulants used were primarily JSC-1A and NU-LHT-4M. Additional regolith simulant control studies were conducted with <150 μm sieved sand and KBr. A nested vial sample preparation approach separated the liquid stock solutions from the regolith, eliminating potential matrix effects between liquid and solid phases. Fifteen microliter aliquots of liquid volatile simulants were added to a 2 mL liquid GC vial and capped in atmosphere. An 18G needle punctured the 2 mL GC vial immediately before being transferred and sealed in a 20 mL GC vial containing 0-0.3 g of regolith simulant, see Figure 1. Separating the analytes ensures any changes observed in the total headspace gases is a result of gas-surface and/or gas-gas interactions. Equipment and Method: Initial GC/MS method development for the separation and identification of relevant headspace gases can be found in Amick, et al. 2023.2 The only hardware change is a different column: a TG-1701MS 30 m × 0.25 mm × 1.00 μm column. The vials were sampled at 10°C, room temperature (~25°C) and 50°C. Low temperature samples were kept in a chilled autosampler stage for at least 1 hour prior to sampling. High temperature samples were agitated at 50°C for 5 minutes immediately prior to injection onto the column. Headspace chromatograms were collected for each combination of temperature, regolith, and volatile simulant, including controls without one or both types of analytes, in triplicate. The chromatogram elution window for each analyte or significant atmospheric gas was identified using the peak mass spectrum cross-referenced with Figure 1.Picture of the nested vial set-up. a NIST MS library search. Each analyte peak was integrated after filtering the mass spectrum trace for the parent or most unique mass-to-charge ratio. For example, the mass-to-charge ratio used to identify, filter for, and integrate the carbon dioxide peak was centered around 44 m/z. Results: Figure 2 shows the integrated peak area for hydrogen sulfide in all combinations of regolith simulants, temperatures, and the addition of ammonia in methanol solution. Multiple repeat experiments with H2S and regolith simulants have confirmed hydrogen sulfide is removed from the headspace within 1 hour when exposed to JSC-1A, NU-LHT-4M and sand (not pictured). The consumption of H2S by lunar regolith simulants at different temperatures indicates surface chemistry will be an integral component in sample integrity and preservation. It is important to note that while the effect of surface chemistry on gaseous hydrogen sulfide is intriguing, further investigation into more chemically accurate regolith simulants is necessary and ongoing. The sulfur in hydrogen sulfide is in its most reduced state while off-the-shelf, terrestrially sourced JSC-1A and NU-LHT-4M are more oxidized than most lunar materials,3which likely leads to different oxidation-reduction reactions than would be expected in lunar regolith. Figure 3 shows the integrated peak area of carbon dioxide for each sample combination that contained ammonia in methanol solution. The addition of ammonia to the GC vials results in a consistent and reproducible decrease in carbon dioxide gas, even at 50°C. The effect became more pronounced when JSC-1A or NU-LHT-4M were present. This set of experiments demonstrated that the sample composition will affect the chemical and physical state of each component present. Future spectroscopic and microscopy experiments will be geared towards identifying the cause for the CO2(g) concentration decrease and the consumption of hydrogen sulfide. As cold and volatile curation scientists, this information provides necessary insight on how to appropriately handle and analyze volatile bearing returned samples, as well as predict the effect chemical composition has on the various sample phases we will analyze upon return to Earth. Unlike traditional curation of geologic materials, the molecules in a sample cannot be identified or processed using the naked eye or even an optical microscope. Volatile curation will require a combination of analytical techniques, including but not limited to highly sensitive gas and solid/condensed phase spectroscopy. This set of experiments has demonstrated the need for more detailed studies of volatile mixtures with mineralogically and geochemically analogous lunar regolith simulants to prepare for the curation of volatile-rich lunar samples from the south polar region of the Moon. References: [1] Colaprete, A., et al. (2010) Science, 330, (463-468). [2] Amick, C. L., et al.(2023) Houston, Texas, [3] Heiken, G. H., et al.(1991) (778-778)

Cecilia L Amick↗

2023 Cleanroom Monitoring for OSIRIS-REx

OSIRIS-REx is an asteroid sample return mission that delivered asteroid regolith from Bennu to Earth on 9/24/2023 [1]. Cleanroom monitoring of OSIRIS-REx Curation facilities has been ongoing since 2021 when construction of the OSIRIS-REx lab at Johnson Space Center (JSC) was completed [2]. The monitoring continues inside of the OSIRIS-REx lab in Houston. Monitoring was also conducted on a temporary cleanroom constructed inside a hangar at the Utah Test and Training Range (UTTR) to initially receive the Sample Return Capsule (SRC) upon its landing there. The following reports on cleanroom monitoring that has taken place in the months leading up to as well as after OSIRIS-REx return. Monitoring techniques used include particle counts, deployment of Si wafer witness plates (Balazs, Inc.) and Al foil witness plates, gas sampling (Balazs, Inc.) and microbiological monitoring. We collected particle counts at both the lab at JSC as well as the temporary cleanroom at UTTR. Particle counts were taken monthly from six locations in the lab at JSC. Particle counts were taken from seven locations at UTTR in July, August, and September. The UTTR cleanroom particle counts were taken daily in the five days leading to OSIRIS-REx return as well as consistently the day of return (every 2 minutes and 15 seconds 7:21 am- 6:27 pm) from one location inside the cleanroom. The particle counts at UTTR consistently stayed well within the ranges of its required ISO 7 equivalent classification (352,000 maximum particles/ m3 ≥ 0.5 μm). Most analysis showed that the particle counts were far below ISO 7 requirements (highest measured count was 61,484 particles/ m3 ≥ 0.5 um). but the elevated instances correlated to exterior hangar doors being open. Particle counts were reduced when keeping exterior hangar doors closed. The particle counts at JSC have stayed consistently within their ISO 5 equivalent classification (3,520 maximum particles/ m3 ≥ 0.5 um). In most instances, the counts are much better except in one instance where the count measured 13,381 particles/ m3 ≥ 0.5 um. The high spike in particle counts in the JSC lab correlated with the air handlers being shut down temporarily the previous day. The particle counts taken in the same location quickly reduced and measured 0 when taken a month later with the air handlers on. We deployed 8-inch semiconductor polished Si wafer witness plates for 24-hour periods inside of the OSIRIS-REx Curation lab at JSC (in July, August, September, and November 2023) and the cleanroom at UTTR (July and September 2023) to test for possible organic and inorganic contaminants. We also deployed these wafers inside of the OSIRIS-REx Touch-and-Go sample Acquisition Mechanism (TAGSAM) glovebox (where Bennu sample processing occurs) and desiccator (Bennu sample storage) at JSC in August 2023. These samples were all sent to Balazs for analysis via Thermal Desorption Gas Chromatography Mass Spectroscopy (TD-GC-MS) to quantify organic compounds and vapor phase decomposition inductively coupled plasma mass spectrometry (VPD-ICP-MS) to quantify inorganic contaminants. We collected air samples using an adsorbent tube connected to a pump for six hours (100 mL/minute) inside of both the JSC lab and the UTTR cleanroom. These samples were taken at JSC in July, August, September, November, and December and at UTTR in July and September. Additionally, a sample was taken just outside of the TAGSAM glovebox airlock door in July. These samples were sent to Balazs for analysis of volatile organics in air. Overall, the OSIRIS-REx lab at JSC and cleanroom at UTTR yielded very low organic and inorganic contaminants (similar results to Genesis lab at JSC which is ISO 4 equivalent) except for boron, which is attributed to the borosilicate glass in the fan filter units. We collected monthly surface and air samples inside the JSC lab to monitor potential microbial contamination. We report the recovery rate for each sampling event, which is defined as the number of samples exhibiting bacterial or fungal growth divided by the total number of samples collected. Since the lab was commissioned in 2021 the median recovery rate is 29%. This recovery rate is consistent with other ISO 5 equivalent labs used to curate astromaterials collections. Increases in recovery rate correspond to construction and/or extra activity in the lab. However, increases in recovery rate do not reliably correlate to increases in particle counts, which highlights the need for a dedicated microbial monitoring program for biologically sensitive collections. We sampled the temporary clean room at UTTR in July, August, and September of 2023 to monitor potential microbial contamination. The recovery rate decreased from 80% in August to 29% in September. However, in all instances, the diversity of bacteria and fungi was higher in the UTTR cleanroom than in the JSC lab. We routinely collected more than twenty different organisms from the UTTR cleanroom. In the JSC lab the median diversity is 2 organisms. Based on these results we hypothesize that microbes from UTTR could be transported back to JSC with the Bennu samples. To mitigate this risk, in September of 2023, we implemented additional cleaning procedures in the JSC lab to reduce the bioburden on surfaces that could come into direct contact with hardware used to process Bennu samples. Since adopting these additional cleaning measures, the median recovery rate has decreased to 14%. We did not observe an increase in fungal or bacterial diversity in the lab in the October sampling. We will continue to monitor this trend closely for the next several months. Supported by NASA under Award NNH09ZDA007O and Contract NNM10AA11C.

Rachel Comstock Funk↗

XSPACE: An LPI-ARES (JSC) Facility for Curation of Meteorites

The XSPACE (eXtraterrestrial SamPle, Analyses, Curation, and Exploration) laboratory is a facility dedicated to the classification and curation of non-Antarctic meteorites. A partnership between the Lunar and Planetary Institute (LPI) and the Astromaterials Research and Exploration Science (ARES) division of NASA, Johnson Space Center (JSC), XSPACE has been approved as an official meteorite repository by the Nomenclature Committee of the Meteoritical Society.

J B Balta↗

High Precision and Spatial Resolution Chemical Interrogation of Planetary Materials Using fs-LA/LIBS in Tandem With Multi-Collector ICP-MS

Combining femtosecond laser ablation (fs-LA) with laser-induced breakdown spectroscopy (LIBS), together with multi-collector inductively coupled plasma mass spectrometry (MC-ICPMS), can provide remarkable insights into the composition, structure, and therefore geologic history of planetary materials and their terrestrial analogs. Using the Applied Spectra iX-fs-Tandem LA-LIBS Instrument and the Nu SP1700 MC-ICP-MS housed within the Center for Isotope Cosmochemistry and Geochronology at NASA Johnson Space Center, we present preliminary tandem fs-LA-(MC)-ICP-MS/LIBS measurements of planetary analog materials. The synergistic integration of fs-LA-LIBS offers high spatial resolution elemental mapping, enabling the identification of microscale variations within samples. Simultaneously, the MC-ICP-MS can deliver precise isotopic analyses, and integrating the two datasets yields a wealth of geochemical information for a given sample. LA-based chemical mapping experiment designs are contingent on the information sought (i.e., quantitative, or semi-quantitative) and the preferred or available volume of material removed for the analysis. For example, occasionally, there are significant limitations in the depth of ablation due to the sample value, the amount of material available, or simply the need to coordinate with other in-situ techniques. In these limited sample scenarios, the “depth-controlled” chemical maps allow for precise post-mapping ion-polishing of the sample, while the isotopic and elemental maps can be used for targeting future analyses (e.g., conventional LA analyses, SIMS analyses, and micro milling for solution ICP-MS/TIMS). The emerging methodology will establish a powerful tool for investigation of astromaterials and materials returned by future planetary sample science missions.

Jacob B Setera↗

The UCLA Cosmochemistry Database

The UCLA Cosmochemistry Database was initiated as part of a data-rescue and -storage project aimed at archiving a variety of cosmochemical data acquired at University of California, Los Angeles (UCLA). The data collection includes elemental compositions of extraterrestrial materials analyzed by UCLA cosmochemists over the last five decades. The analytical techniques include atomic absorption spectrometry (AAS) and neutron activation analysis (NAA) at UCLA. The data collection is stored on the Astromaterials Data System (Astromat). We provide both interactive tables and downloadable datasheets for users to access all data. The UCLA Cosmochemistry Database archives cosmochemical data that are essential tools for increasing our understanding of the nature and origin of extraterrestrial materials. Future studies can reference the data collection in the examination, analysis, and classification of newly acquired extraterrestrial samples.

Bidong Zhang↗

The Collection, Usage, and Preliminary Examination of the Apollo Sample Suite: Lessons for Artemis

Apollo Sample Collection and Usage: From 1969 to 1972 there were six Apollo missions to the surface of the Moon during which the astronauts collected 382 kg of rock and regolith (~2200 samples). The samples collected fall into these general categories: rocks (~66% by mass), rake samples (~4%), bulk regolith (~24%), and specialty regolith (deep drill cores, drive tubes, sealed bulk regolith) samples (~6%). In each category there are a variety of different subtypes available for study, e.g., among the bulk regolith samples there are also skim, trench, and (partially) shaded regolith samples each sampling unique types or depths of regolith. This variety of subsamples has enabled a multitude of different studies over the past 55 years (>3400 individual requests). We are still averaging ~50 unique requests and have allocated >500 individual Apollo samples annually for the past 10 years (2020 excepted). Looking at the 4,675 non-ANGSA (Apollo Next Generation Sample Analysis) samples allocated over the past 10 years, the proportions of allocated samples do not precisely align with the abundance (by mass) of those samples withing the collection: Rock (69.4 %); Rake (10.8 %); Bulk Regolith (15.5 %); Drive Tube (3.3 %); Core/Specialty (1.0 %). Apollo Preliminary Examination (PE): The PE process differs significantly for the various sample types enumerated above; we focus on regolith and rock samples here. During the Apollo mission era, the PE process evolved over the course of the missions; below is what was done for the Apollo 17 mission. For regolith samples, the PE process was: (1) documented bags containing regolith are opened, photographed, and described; (2) large rocks are removed and treated separately; (3) 25% to 33% of the bulk soil is scooped out, weighed, and stored in reserve; (4) the remaining sample is sieved to produce the size fractions <1, 1- 2, 2-4, and 4-10 mm, all of which are weighed. For rock samples, the process is: (1) removing rocks from the container(s) it came back from the Moon in; (2) rematching any materials that spalled off the rock to their original location; (3) numbering, weighing, and basic photographic documentation; (4) dusting with a gentle N2 gas jet; (5) Orthogonal photography; (6) detailed description of the textures and features of the rock; (7) rock modelling and measurement; (8) stereophotography; (9) determination of the orientation of the rock on the lunar surface. Drive tubes and deep drill cores were not characterized during PE beyond an initial weight and a sketch of the interior tube materials derived from 2D medical X-ray images. Catalogs: The ongoing utility of the Apollo samples is enabled by the robust cataloguing process for the samples [3-5], which allows the scientific community to accurately request samples uniquely suited to their proposed studies. A common misconception, however, is the amount of detail that goes into the initial catalog (e.g., [6]) for a collection from the preliminary examination (PE) period, versus what goes into the catalogs that come later in the life cycle of the samples from that mission (e.g., [7]). The only required data for a PE catalog is a weight, a basic photograph, and a description of the nature of the sample. Artemis PE: Over the past few years, the ongoing ANGSA project studied previously unopened Apollo 17 double drive tube samples 73001/2 [1], and a PE of the drive tubes was done. The PE took the existing core dissection process (developed during PE of Apollo cores in the 1970s, 1980s), and modernized it [7]. The main lesson from the ANGSA PE relative to future missions was that the physical work done during PE of lunar samples has not changed much over the past 5 decades. The use of “modern” technology during PE (e.g., XCT; multispectral analyses) resulted in an enhanced initial understanding of the 73001 and 73002 drive tubes, but greatly increased the time required. The lessons learned from recent astromaterial PEs (e.g., ANGSA and OREx) are important to consider when planning for Artemis, but the unique nature of the Artemis Campaign means many lessons learned from these mission will not be applicable. Given the time constraints (6 months) and likely number of samples that will be returned by Artemis (>200), the Artemis PE catalog will necessarily look much more like [4] than [6].

J Gross↗

Genesis Solar Wind – Capture, Return, Curate and Analyze: Looking Backward Reviewing Sample Collection Hardware

Genesis, as the first U.S. spacecraft to return astromaterial samples since Apollo, not only integrated the mission planning and flight teams, but also the science and sample curation teams during the mission development period. Since Genesis is a sample return mission, the Science Team was essential in certifying the collectors (sample containers for solar atoms). Burnett and the science team defined the purity of collector materials and ability to analyze solar wind composition to the precision required for planetary science. The science team’s choices included a variety of very pure materials which are described, including rationale for selection. The JPL Project Scientist networked with specialty vendors refining specifications and fabricating several of the materials. JPL engineering team designed and fabricated the collector arrays. LANL designed and built an electrostatic concentrator. JSC procured these materials with exacting specifications.

SOLAR WIND↗

Abundant Ammonia and Nitrogen-Rich Soluble Organic Matter in Samples From Asteroid (101955) Bennu

Organic matter in meteorites reveals clues about early Solar System chemistry and the origin of molecules important to life, but terrestrial exposure complicates interpretation. Samples returned from the B-type asteroid Bennu by the Origins, Spectral Interpretation, Resource Identifcation, and Security–Regolith Explorer mission enabled us to study pristine carbonaceous astromaterial without uncontrolled exposure to Earth’s biosphere. Here we show that Bennu samples are volatile rich, with more carbon, nitrogen and ammonia than samples from asteroid Ryugu and most meteorites. Nitrogen-15 isotopic enrichments indicate that ammonia and other N-containing soluble molecules formed in a cold molecular cloud or the outer protoplanetary disk. We detected amino acids (including 14 of the 20 used in terrestrial biology), amines, formaldehyde, carboxylic acids, polycyclic aromatic hydrocarbons and N-heterocycles (including all fve nucleobases found in DNA and RNA), along with ~10,000 N-bearing chemical species. All chiral non-protein amino acids were racemic or nearly so, implying that terrestrial life’s left-handed chirality may not be due to bias in prebiotic molecules delivered by impacts. The relative abundances of amino acids and other soluble organics suggest formation and alteration by low-temperature reactions, possibly in NH3-rich fuids. Bennu’s parent asteroid developed in or accreted ices from a reservoir in the outer Solar System where ammonia ice was stable.

Daniel P Glavin↗

Raising TRL of Your Lunar Payload

Preparing payloads for the lunar surface requires rigorous testing that accurately captures the extreme environmental and operational conditions. This presentation provides an overview of the lunar relevant test capabilities at NASA JSC’s Astromaterials Research and Exploration Science (ARES) laboratories as well as the Energy System Test Area (ESTA) Lunar Development and Test Facility. These facilities allow teams to assess hardware performance in dusty vacuum environments, characterize interactions with high fidelity lunar regolith simulants, evaluate mechanical and thermal durability, and understand the effects of micrometeoroid and orbital debris impacts—critical factors for certifying payloads that will operate on the lunar surface or in orbit. While Lunar power challenges such as variable illumination, extreme temperatures, and dust driven degradation will be briefly summarized, the focus of this talk is on how JSC’s test infrastructure enables developers to validate designs, reduce mission risk, and ensure compatibility with CLPS and Artemis objectives. NASA JSC’s expertise and experience help industry, academic, and government teams prepare robust hardware ready for successful delivery and operation on the surface of the Moon.

Lunar Regolith Simulant↗

Raising TRL of Your Lunar Payload

Preparing payloads for the lunar surface requires rigorous testing that accurately captures the extreme environmental and operational conditions. This presentation provides an overview of the lunar relevant test capabilities at NASA JSC’s Astromaterials Research and Exploration Science (ARES) laboratories as well as the Energy System Test Area (ESTA) Lunar Development and Test Facility. These facilities allow teams to assess hardware performance in dusty vacuum environments, characterize interactions with high fidelity lunar regolith simulants, evaluate mechanical and thermal durability, and understand the effects of micrometeoroid and orbital debris impacts—critical factors for certifying payloads that will operate on the lunar surface or in orbit. While Lunar power challenges such as variable illumination, extreme temperatures, and dust driven degradation will be briefly summarized, the focus of this talk is on how JSC’s test infrastructure enables developers to validate designs, reduce mission risk, and ensure compatibility with CLPS and Artemis objectives. NASA JSC’s expertise and experience help industry, academic, and government teams prepare robust hardware ready for successful delivery and operation on the surface of the Moon.

Laboratories↗

Sierra Gorda 009: A New Member of the Metal-Rich G Chondrites Grouplet

We investigated the metal-rich chondrite Sierra Gorda (SG) 009, a member of the new G chondrite grouplet (also including NWA 5492, GRO 95551). G chondrites contain 23% metal, very reduced silicates, and rare oxidized mineral phases (Mg-chromite, FeO-rich pyroxene). G chondrites are not related to CH-CB chondrites, based on bulk O, C and N isotopic compositions, mineralogy and geochemistry. G chondrites have no fine-grained matrix or matrix lumps enclosing hydrated material typical for CH-CB chondrites. G chondrites’ average metal compositions are similar to H chondrites. Siderophile and lithophile geochemistry indicate sulfidization and fractionation of the SG 009 metal and silicates, unlike NWA 5492 and GRO 05551. The G chondrites have average O isotopic compositions DELTA 17O >0 ‰ ranging between bulk enstatite (E) and ordinary (O) chondrites. An Al-rich chondrule from SG 009 has DELTA 17O <0 ‰ indicating some heterogeneity in oxygen isotopic composition of G chondrite components. SG 009’s bulk carbon and nitrogen isotopic compositions correspond to E and O chondrites. Neon isotopic composition reflects a mixture of cosmogenic and solar components, and cosmic ray exposure age of SG 009 is typical for O, E, and R chondrites. G chondrites are closely related to O, E, and R chondrites and may represent a unique metal-rich parent asteroid containing primitive and fractionated material from the inner Solar System. Oxidizing and reducing conditions during SG 009 formation may be connected with a chemical micro-environment and possibly could indicate that G chondrites may have formed by a planetesimal collision resulting in the lack of matrix.

chondrite↗