Search NASA⌕ Search

SEARCH · Search NASA

Results for “beam splitters”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Ultraviolet-visible optical isolators based on CeF{sub 3} Faraday rotator

The first ultraviolet (UV) and visible optical isolators based on CeF{sub 3} are demonstrated. CeF{sub 3} possesses unique properties as Faraday rotator for the UV-visible wavelength region: a wide transparency range (wavelength of >300 nm) and an outstanding Verdet constant. In contrast, currently used terbium-gallium garnets and magneto-optical glasses possess a low transparency in the visible and a small Verdet constant in the UV, respectively. The optical isolator prototypes consist of a CeF{sub 3} rod, a single ring magnet, and a couple of beam splitters. The ring magnets have been designed to guarantee a homogeneous magnetic field; for it, numerical simulations have been carried out. The two prototypes are very compact and operate in the UV at 355 and in the visible at 405 nm, respectively. The performance of these devices indicates the high potential of CeF{sub 3} as a new UV-visible Faraday rotator, specially for shorter wavelengths where at present there are no optical isolators available.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measuring arbitrary-order coherences: Tomography of single-mode multiphoton polarization-entangled states

A scheme is discussed for measuring Nth-order coherences of two orthogonally polarized light fields in a single spatial mode at very limited experimental cost. To implement the scheme, the only measurements needed are the Nth-order intensity moments after the light beam has passed through two quarter-wave plates, one half-wave plate, and a polarizing beam splitter for specific settings of the wave plates. It is shown that this method can be applied for arbitrarily large N. A set of explicit values is given for the settings of the wave plates, constituting an optimal measurement of the Nth-order coherences for any N. For Fock states the method introduced here corresponds to a full state tomography. Applications of the scheme to systems other than polarization optics are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Reliable source of conditional states from single-mode pulsed thermal fields by multiple-photon subtraction

We demonstrate the effect of multiple-photon subtraction on the generation of conditional states in the pulsed regime. Our experimental scheme relies on a beam splitter (BS) and a pair of linear photodetectors that are able to resolve up to tens of photons. We use a single-mode thermal field at the input port of the BS to test the reliability of our scheme, and we show good agreement with the theory by fully characterizing the conditional outgoing states in terms of photon-number statistics and non-Gaussianity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cavity quantum electro-optics. II. Input-output relations between traveling optical and microwave fields

In a previous paper [Phys. Rev. A 81, 063837 (2010)], I proposed a quantum model of the cavity electro-optic modulator, which can coherently couple an optical cavity mode to a microwave resonator mode and enable quantum operations on the two modes, including laser cooling of the microwave resonator, electro-optic entanglement, and backaction-evading optical measurement of a microwave quadrature. In this sequel, I focus on the quantum input-output relations between traveling optical and microwave fields coupled to the cavity electro-optic modulator. With red-sideband optical pumping, the relations are shown to resemble those of a beam splitter for the traveling fields, so that in the ideal case of zero parasitic loss and critical coupling, microwave photons can be coherently up converted to ''flying'' optical photons with unit efficiency, and vice versa. With blue-sideband pumping, the modulator acts as a nondegenerate parametric amplifier, which can generate two-mode squeezing and hybrid entangled photon pairs at optical and microwave frequencies. These fundamental operations provide a potential bridge between circuit quantum electrodynamics and quantum optics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Balancing efficiencies by squeezing in realistic eight-port homodyne detection

We address measurements of covariant phase observables (CPOs) by means of realistic eight-port homodyne detectors. We do not assume equal quantum efficiencies for the four photodetectors and investigate the conditions under which the measurement of a CPO may be achieved. We show that balancing the efficiencies using an additional beam splitter allows us to achieve a CPO at the price of reducing the overall effective efficiency, and prove that it is never a smearing of the ideal CPO achievable with unit quantum efficiency. An alternative strategy based on employing a squeezed vacuum as a parameter field is also suggested, which allows one to increase the overall efficiency in comparison to the passive case using only a moderate amount of squeezing. Both methods are suitable for implementation with current technology.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Statistical strength of experiments to reject local realism with photon pairs and inefficient detectors

Because of the fundamental importance of Bell's theorem, a loophole-free demonstration of a violation of local realism (LR) is highly desirable. Here, we study violations of LR involving photon pairs. We quantify the experimental evidence against LR by using measures of statistical strength related to the Kullback-Leibler (KL) divergence, as suggested by van Dam et al.[W. van Dam, R. D. Gill, and P. D. Grunwald, IEEE Trans. Inf. Theory. 51, 2812 (2005)]. Specifically, we analyze a test of LR with entangled states created from two independent polarized photons passing through a polarizing beam splitter. We numerically study the detection efficiency required to achieve a specified statistical strength for the rejection of LR depending on whether photon counters or detectors are used. Based on our results, we find that a test of LR free of the detection loophole requires photon counters with efficiencies of at least 89.71%, or photon detectors with efficiencies of at least 91.11%. For comparison, we also perform this analysis with ideal unbalanced Bell states, which are known to allow rejection of LR with detector efficiencies above 2/3.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Visibility bound caused by a distinguishable noise particle

We investigate how the distinguishability of a 'noise' particle degrades interference of the 'signal' particle. The signal, represented by an equatorial state of a photonic qubit, is mixed with noise, represented by another photonic qubit, via linear coupling on a beam splitter. We report on the degradation of the signal photon interference depending on the degree of indistinguishability between the signal and noise photons. When the photons are completely distinguishable in principle but technically indistinguishable, the visibility drops to the value 1/{radical}(2). As the photons become more indistinguishable, the maximal visibility increases and reaches the unit value for completely indistinguishable photons. We have examined this effect experimentally using a setup with a fiber-optics two-photon Mach-Zehnder interferometer.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An extreme ultraviolet Michelson interferometer for experiments at free-electron lasers

We present a Michelson interferometer for 13.5 nm soft x-ray radiation. It is characterized in a proof-of-principle experiment using synchrotron radiation, where the temporal coherence is measured to be 13 fs. The curvature of the thin-film beam splitter membrane is derived from the observed fringe pattern. The applicability of this Michelson interferometer at intense free-electron lasers is investigated, particularly with respect to radiation damage. This study highlights the potential role of such Michelson interferometers in solid density plasma investigations using, for instance, extreme soft x-ray free-electron lasers. A setup using the Michelson interferometer for pseudo-Nomarski-interferometry is proposed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray Optics for BES Light Source Facilities

Each new generation of synchrotron radiation sources has delivered an increase in average brightness 2 to 3 orders of magnitude over the previous generation. The next evolution toward diffraction-limited storage rings will deliver another 3 orders of magnitude increase. For ultrafast experiments, free electron lasers (FELs) deliver 10 orders of magnitude higher peak brightness than storage rings. Our ability to utilize these ultrabright sources, however, is limited by our ability to focus, monochromate, and manipulate these beams with X-ray optics. X-ray optics technology unfortunately lags behind source technology and limits our ability to maximally utilize even today’s X-ray sources. With ever more powerful X-ray sources on the horizon, a new generation of X-ray optics must be developed that will allow us to fully utilize these beams of unprecedented brightness. The increasing brightness of X-ray sources will enable a new generation of measurements that could have revolutionary impact across a broad area of science, if optical systems necessary for transporting and analyzing X-rays can be perfected. The high coherent flux will facilitate new science utilizing techniques in imaging, dynamics, and ultrahigh-resolution spectroscopy. For example, zone-plate-based hard X-ray microscopes are presently used to look deeply into materials, but today’s resolution and contrast are restricted by limitations of the current lithography used to manufacture nanodiffractive optics. The large penetration length, combined in principle with very high spatial resolution, is an ideal probe of hierarchically ordered mesoscale materials, if zone-plate focusing systems can be improved. Resonant inelastic X-ray scattering (RIXS) probes a wide range of excitations in materials, from charge-transfer processes to the very soft excitations that cause the collective phenomena in correlated electronic systems. However, although RIXS can probe high-energy excitations, the most exciting and potentially revolutionary science involves soft excitations such as magnons and phonons; in general, these are well below the resolution that can be probed by today’s optical systems. The study of these low-energy excitations will only move forward if advances are made in high-resolution gratings for the soft X-ray energy region, and higher-resolution crystal analyzers for the hard X-ray region. In almost all the forefront areas of X-ray science today, the main limitation is our ability to focus, monochromate, and manipulate X-rays at the level required for these advanced measurements. To address these issues, the U.S. Department of Energy (DOE) Office of Basic Energy Sciences (BES) sponsored a workshop, X-ray Optics for BES Light Source Facilities, which was held March 27–29, 2013, near Washington, D.C. The workshop addressed a wide range of technical and organizational issues. Eleven working groups were formed in advance of the meeting and sought over several months to define the most pressing problems and emerging opportunities and to propose the best routes forward for a focused R&D program to solve these problems. The workshop participants identified eight principal research directions (PRDs), as follows: Development of advanced grating lithography and manufacturing for high-energy resolution techniques such as soft X-ray inelastic scattering. Development of higher-precision mirrors for brightness preservation through the use of advanced metrology in manufacturing, improvements in manufacturing techniques, and in mechanical mounting and cooling. Development of higher-accuracy optical metrology that can be used in manufacturing, verification, and testing of optomechanical systems, as well as at wavelength metrology that can be used for quantification of individual optics and alignment and testing of beamlines. Development of an integrated optical modeling and design framework that is designed and maintained specifically for X-ray optics. Development of nanolithographic techniques for improved spatial resolution and efficiency of zone plates. Development of large, perfect single crystals of materials other than silicon for use as beam splitters, seeding monochromators, and high-resolution analyzers. Development of improved thin-film deposition methods for fabrication of multilayer Laue lenses and high-spectral-resolution multilayer gratings. Development of supports, actuator technologies, algorithms, and controls to provide fully integrated and robust adaptive X-ray optic systems. Development of fabrication processes for refractive lenses in materials other than silicon. The workshop participants also addressed two important nontechnical areas: our relationship with industry and organization of optics within the light source facilities. Optimization of activities within these two areas could have an important effect on the effectiveness and efficiency of our overall endeavor. These are crosscutting managerial issues that we identified as areas that needed further in-depth study, but they need to be coordinated above the individual facilities. Finally, an issue that cuts across many of the optics improvements listed above is routine access to beamlines that ideally are fully dedicated to optics research and/or development. The success of the BES X-ray user facilities in serving a rapidly increasing user community has led to a squeezing of beam time for vital instrumentation activities. Dedicated development beamlines could be shared with other R&D activities, such as detector programs and novel instrument development. In summary, to meet the challenges of providing the highest-quality X-ray beams for users and to fully utilize the high-brightness sources of today and those that are on the horizon, it will be critical to make strategic investments in X-ray optics R&D. This report can provide guidance and direction for effective use of investments in the field of X-ray optics and potential approaches to develop a better-coordinated program of X-ray optics development within the suite of BES synchrotron radiation facilities. Due to the importance and complexity of the field, the need for tight coordination between BES light source facilities and with industry, as well as the rapid evolution of light source capabilities, the workshop participants recommend holding similar workshops at least biannually.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Single-Crystal X-Ray Spectropolarimeter

X-ray spectropolarimetry is a diagnostics technique suitable for measuring intense electron beams and strong magnetic fields in hot, dense plasmas. To increase the accuracy achievable, we investigated the possibility of measuring both orthogonal components of linear polarization simultaneously using a single crystal. We demonstrated experimentally for the first time that crystals with cubic symmetry can be used as polarizing beam splitters. We also found that the polarization-splitting planes in cubic crystals can be accessed in two crystal orientations, a property that can be used to decrease the clutter in polarized spectra. In parallel, we developed a ray-tracing code and are working to add the crystal reflectivity to instrument modeling codes, to help us interpret the spectra and to design spectroscopic and spectropolarimetric instruments. This work is motivated by the need to perform measurements of important quantities in difficult experimental conditions, such as the axial magnetic field at stagnation in magnetized liner inertial fusion loads.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gate tuneable beamsplitter in ballistic graphene

We present a beam splitter in a suspended, ballistic, multiterminal, bilayer graphene device. By using local bottomgates, a p-n interface tilted with respect to the current direction can be formed. We show that the p-n interface acts as a semi-transparent mirror in the bipolar regime and that the reflectance and transmittance of the p-n interface can be tuned by the gate voltages. Moreover, by studying the conductance features appearing in magnetic field, we demonstrate that the position of the p-n interface can be moved by 1 μm. The herein presented beamsplitter device can form the basis of electron-optic interferometers in graphene.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Passive scheme with a photon-number-resolving detector for monitoring the untrusted source in a plug-and-play quantum-key-distribution system

A passive scheme with a beam splitter and a photon-number-resolving (PNR) detector is proposed to verify the photon statistics of an untrusted source in a plug-and-play quantum-key-distribution system by applying a three-intensity decoy-state protocol. The practical issues due to statistical fluctuation and detection noise are analyzed. The simulation results show that the scheme can work efficiently when the total number of optical pulses sent from Alice to Bob is above 10{sup 8}, and the dark count rate of the PNR detector is below 0.5 counts/pulse, which is realizable with current techniques. Furthermore, we propose a practical realization of the PNR detector with a variable optical attenuator combined with a threshold detector.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantum state engineering, purification, and number-resolved photon detection with high-finesse optical cavities

We propose and analyze a multifunctional setup consisting of high-finesse optical cavities, beam splitters, and phase shifters. The basic scheme projects arbitrary photonic two-mode input states onto the subspace spanned by the product of Fock states |n>|n> with n=0,1,2,.... This protocol does not only provide the possibility to conditionally generate highly entangled photon number states as resource for quantum information protocols but also allows one to test and hence purify this type of quantum states in a communication scenario, which is of great practical importance. The scheme is especially attractive as a generalization to many modes allows for distribution and purification of entanglement in networks. In an alternative working mode, the setup allows for quantum nondemolition number resolved photodetection in the optical domain.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Strong Einstein-Podolsky-Rosen entanglement from a single squeezed light source

Einstein-Podolsky-Rosen (EPR) entanglement is a criterion that is more demanding than just certifying entanglement. We theoretically and experimentally analyze the low-resource generation of bipartite continuous-variable entanglement, as realized by mixing a squeezed mode with a vacuum mode at a balanced beam splitter, i.e., the generation of so-called vacuum-class entanglement. We find that in order to observe EPR entanglement the total optical loss must be smaller than 33.3 %. However, arbitrarily strong EPR entanglement is generally possible with this scheme. We realize continuous-wave squeezed light at 1550 nm with up to 9.9 dB of nonclassical noise reduction, which is the highest value at a telecom wavelength so far. Using two phase-controlled balanced homodyne detectors we observe an EPR covariance product of 0.502{+-}0.006<1, where 1 is the critical value. We discuss the feasibility of strong Gaussian entanglement and its application for quantum key distribution in a short-distance fiber network.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nanoscale defect detection by heterodyne interferometry

We construct an instrument that facilitates the measurement of nanoscale defects. It is based on heterodyne interferometry with phase measurement that utilizes a polarizing beam splitter to form a measuring signal and an oscillating cantilever tip that acts as a scanning probe to get the measurement values of sample topography. The dependence of the tip displacement on the variation of tip-sample distance and the comb scanning of the sample topography are investigated by experiments. The results prove that the tip displacement increases and is enough to be discriminated in various positions where the sample is approached. The system has been successfully utilized to measure the defect characterization by measuring the pitch of the standard sample. The results also show that the heterodyne system has good repeatability, a large measurement range, and high accuracy, with a measurement stability of 0.5 nm.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Modelling an electro-optical modulator based on a vertical p – n junction in a silicon-on-insulator structure

We report the results of numerical simulation of a Mach – Zehnder electro-optical modulator using beam splitters based on multimode interference in a silicon-on-insulator structure. The control is provided due to the depletion effect in the vertical p – n junction, which can be fabricated using the self-alignment technology. An optimal modulator design is proposed, which impedance is matched with an external 50-Ω load, for which, with a reverse bias of – 5 V and an active length of 1.7 mm, the optical frequency bandwidth of ∼ 50 GHz can be achieved. A special doping profile of the p – n junction of the modulator is presented, which provides an optical frequency bandwidth of 30 GHz with a reverse bias of –3 V and a modulator length of 2.5 mm. Such modulators can be used in integrated optics, optical communications and radio photonics devices. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multiplex and simultaneous measurement of displacement and temperature using tapered fiber and fiber Bragg grating

A simple method to work out the multiplexing of tapered fiber based sensors is proposed and demonstrated. By cascading a tapered fiber with a fiber Bragg grating (FBG), the sensor head is provided with a wavelength identification, different FBGs provide the sensor heads with different reflective peaks and they can be distinguished in optical spectrum. By compositing several such sensor heads with a multi-channel beam splitter, a star-style topological structure sensor for multipoint sensing is achieved. At the same time, the output intensity at the peak wavelength is sensitive to one external physical parameter applied on the related FBG-cascaded tapered fiber and the central wavelength of the peak is only sensitive to temperature, so that that parameter and temperature can be measured simultaneously. A sensor for dual-point measurement of the displacement and temperature simultaneously is experimentally demonstrated by using a 2 x 2 coupler in this paper. Experiment results show that the sensor works well and the largest sensitivities reach to 0.11 dB/{mu}m for displacement in the range of 0-400 {mu}m, and {approx}0.0097 nm/ deg. C for temperature between 20 deg. C and 70 deg. C.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Causality, apparent 'superluminality', and reshaping in barrier penetration

We consider tunneling of a nonrelativistic particle across a potential barrier. It is shown that the barrier acts as an effective beam splitter which builds up the transmitted pulse from the copies of the initial envelope shifted in the coordinate space backward relative to the free propagation. Although along each pathway causality is explicitly obeyed, in special cases reshaping can result an overall reduction of the initial envelope, accompanied by an arbitrary coordinate shift. In the case of a high barrier the delay amplitude distribution (DAD) mimics a Dirac {delta} function, the transmission amplitude is superoscillatory for finite momenta and tunneling leads to an accurate advancement of the (reduced) initial envelope by the barrier width. In the case of a wide barrier, initial envelope is accurately translated into the complex coordinate plane. The complex shift, given by the first moment of the DAD, accounts for both the displacement of the maximum of the transmitted probability density and the increase in its velocity. It is argued that analyzing apparent 'superluminality' in terms of spacial displacements helps avoid contradiction associated with time parameters such as the phase time.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗