Search NASA⌕ Search

SEARCH · Search NASA

Results for “building control systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Modular Autonomous Systems Technology Framework: A Distributed Solution for System Monitoring and Control

The Modular Autonomous Systems Technology (MAST) framework is a tool for building distributed, hierarchical autonomous systems. Originally intended for the autonomous monitoring and control of spacecraft, this framework concept provides support for variable autonomy, assume-guarantee contracts, and efficient communication between subsystems and a centralized systems manager. MAST was developed at NASA's Johnson Space Center (JSC) and has been applied to an integrated spacecraft example scenario.

Badger, Julia M.↗

Dynamic Assurance of Autonomous Systems through Ground Control Software∗

Assurance cases are being increasingly acknowledged as a way to build trust in complex systems with autonomous capabilities [1]. An assurance case is a comprehensive, defensible, and valid justification that a system will function as intended for the specific mission and operating environment. Such justifications for systems with autonomous capabilities are often based on various probabilistic quantifications [2]. Due to the dynamic nature of the environmental conditions in which these systems operate, as well as the changing nature of the autonomous systems themselves, these probabilistic quantifications cannot be simply estimated once during design time. Rather, they need to be continually evaluated during systems operations to ensure that the assurance case justifications are valid. We refer to the assurance case that combines both the static and dynamic elements as a Dynamic Assurance Case (DAC).

dynamic assurance case↗

Potential for integrated optical circuits in advanced aircraft with fiber optic control and monitoring systems

Fiber optic technology is expected to be used in future advanced weapons platforms as well as commercial aerospace applications. Fiber optic waveguides will be used to transmit noise free, high speed data between a multitude of computers as well as audio and video information to the flight crew. Passive optical sensors connected to control computers with optical fiber interconnects will serve both control and monitoring functions. Implementation of fiber optic technology has already begun. Both the military and NASA have several programs in place. A cooperative program, called FOCSI (Fiber Optic Control System Integration), between NASA Lewis and the NAVY to build, environmentally test and flight demonstrate sensor systems for propulsion and flight control systems is currently underway. Integrated Optical Circuits (IOC's) are also being given serious consideration for use in advanced aircraft systems. IOC's will result in miniaturization and localization of components to generate, detect optical signals and process them for use by the control computers. In some complex systems IOC's may be required to perform calculations optically if the technology is ready, replacing some of the electronic systems used today. IOC's are attractive because they will result in rugged components capable of withstanding severe environments in advanced aerospace vehicles. Manufacturing technology developed for microelectronic integrated circuits applied to IOC's will result in cost effective manufacturing. This paper reviews the current FOCSI program and describes the potential role of IOC's in FOCSI applications.

Robert Baumbick↗

A multiphase flow model of water droplets dielectrophoretic-induced air dehumidification phenomena

Air humidity in indoor spaces plays a critical role in human comfort and health. Dehumidification systems are used for building humidity controls, but they can take significant energy consumption, especially in geographic locations with high outdoor humidity and warm climates. Consequently, there is a growing demand for innovative dehumidification processes that consume minimal energy. Dielectrophoretic air dehumidification represents one such promising approach. However, it has not garnered significant attention due to the absence of engineering models and simulation tools capable of evaluating its performance and limitations at large-scale airflows. A new numerical multiphase CFD model, which is also experimentally validated, is developed in a customized Reacting Foam solver based on OpenFOAM® version 9. The newly developed model seeks to decrease substantial energy consumption and lower costs by leveraging the dielectrophoretic phenomenon to regulate moisture levels in the air. The solver integrates a hybrid Eulerian-Lagrangian framework to track the droplet's trajectory and growth rate while solving the continuum equations for the moist air. An electrospray produces electrically charged droplets, which grow during their in-flight trajectories as water vapor condenses onto their surfaces. The role of electrostatic forces in promoting vapor condensation within a high-gradient electrical field is investigated, and the dielectrophoretic vapor nucleation process on charged water droplets is discussed. The CFD model was validated against results from the literature and from proof-of-concept experiments conducted by the authors, which showed a 2 % air dehumidification with a single electrospray and airflow rate of 5 cubic feet per minute. The simulation results indicated that augmenting the number of electrically charged spray droplets increased the dehumidification of the air to 25 %. The initial mean droplet diameter, the orientation of the injector and relative humidity significantly influence the assessment of dehumidification. As a result, scaling up this approach to larger airflow volumes is identified as a potential future research direction.

42 ENGINEERING↗

Market Barriers and Drivers for the Next Generation Fault Detection and Diagnostic Tools

Commercial buildings in the U.S. consume as much as 30% excess energy compared to buildings that operate fault free and efficiently. Fault detection and diagnostic (FDD) platforms help to continually identify operational inefficiencies and maintain low-carbon performance. However, the recommendations generated by FDD tools need to be implemented by technicians, resulting in delays or lost savings opportunities. Recent research advances showed fault AUTOcorrection integrating with commercial FDD offerings filled this gap. Seven innovative AUTOcorrection algorithms were integrated into two FDD platforms and deployed across four buildings. The enhanced tools successfully correct faults focusing on incorrectly programmed schedules, override not released, control hunting, rogue zone, and suboptimal setpoints. Although its technical efficacy has been proven in the field, fault AUTO-correction is still early in the deployment cycle and opportunities and barriers need to be understood to reach its full potential in market transformation. This paper broadly introduces the new technology that automatically corrects HVAC faults. The authors describe in detail technology potential, market barriers, and enablers for scalability based on field testing results and interviews with the FDD providers and facility managers. The interviewees agreed that AUTO-correction can reduce the extent to which savings are dependent upon human intervention, scale building operators’ ability to act on FDD findings (especially for facilities with small operation teams), and achieve significant savings. To enable scalable deployment, future efforts are needed to overcome the barriers such as cybersecurity and accountability concerns from building operators and standardization of control parameters used in building automation systems.

Pritoni, Marco↗

Leading University Students to the Edge of Space

For over 16 years, the Louisiana Space Grant Consortium (LaSPACE), the NASA Balloon Program Office (BPO), and the NASA Columbia Scientific Balloon Facility (CSBF) have collaborated in a series of high altitude balloon-based programs involving hands-on authentic learning experiences that expose university students and other participants to technical skills, teamwork dynamics, and effective communication methods. Such programs go beyond what is possible to achieve in a normal classroom and help prepare future engineers and scientists for a successful aerospace workforce career. In our collaborative effort, LaSPACE has focused on the program content and student mentoring while NASA BPO and CSBF provide balloon flight support and operations. The entry-level Louisiana Aerospace Catalyst Experiences for Students (LaACES) builds students’ skills in basic electronics, sensor interfacing, real-time programming, mechanical development, and project management. These skills are then applied to the design, development, fabrication, and flight of a small (∼500 gram) balloon payload. Finally, the payloads are flight-tested to an altitude of ∼30 km using a 2 kg latex sounding balloon. The LaACES program includes a set of lectures, activities, and Arduino Mega based electronic kits that are used for skill building and as a core control system for the student payload. The more advanced High Altitude Student Platform (HASP) is designed to carry ∼twelve 3 to 20 kg student payloads to an altitude of about 36 kilometers with flight durations of 10 to 20 hours using a ∼311,500 cubic meter, zero pressure balloon. HASP provides all student payloads with power, downlink telemetry, uplink commanding, and real-time HD video for instrument control and assessment during the flight. While originally developed for university students, these programs have been adapted to projects focused on high school teachers as well as affecting minorities underrepresented in aerospace related science and engineering fields. We are now in the process of adapting the LaACES materials to a pre-engineering curriculum for high school students as well as for widespread access over the internet. During this presentation, we will provide details of both the LaACES and HASP programs, how these programs have engaged participants from all demographic groups, and our current plans for continuing and expanding upon our success.

University↗

Lunar Latitude and Terrain Radiator Sensitivity Study

The thermal environment on the moon is highly complex and diverse. The lunar surface near the equator develops extreme hot average temperatures during the lunar day due to solar flux vectors that are nearly orthogonal to the surface. The lunar poles have a cold and uniquely complex thermal environment with low solar elevation angles and permanently shadowed regions located just kilometers from some of the most highly illuminated regions of the moon. Likewise, the topography can range from very flat crater basins to dramatically tall features such as mountains and crater rims. Consequently, when sizing the radiators of a lunar surface vehicle, the specific thermal environment found in the targeted landing or deployment zone must be well understood to build robust appropriately scaled thermal control systems. Here described are parametric studies that characterize the sensitivity of lunar radiator performance to lunar terrain and latitude. Heat rejection is calculated for different radiator tilt angles in a variety of terrain environments. Radiator performance as a function of underside thermal condition is also characterized at lunar latitudes ranging from equatorial to polar. Impacts of latitude and terrain on radiator performance are quantified, and regions are identified where the thermal environment is more or less favorable for specific radiator designs.

Lunar Vehicle Radiator↗

Lunar Latitude and Terrain Radiator Sensitivity Study

The thermal environment on the moon is highly complex and diverse. The lunar surface near the equator develops extreme hot average temperatures during the lunar day due to solar flux vectors that are nearly orthogonal to the surface. The lunar poles have a cold and uniquely complex thermal environment with low solar elevation angles and permanently shadowed regions located just kilometers from some of the most highly illuminated regions of the moon. Likewise, the topography can range from very flat crater basins to dramatically tall features such as mountains and crater rims. Consequently, when sizing the radiators of a lunar surface vehicle, the specific thermal environment found in the targeted landing or deployment zone must be well understood to build robust, appropriately scaled thermal control systems. Here described are parametric studies that characterize the sensitivity of lunar radiator performance to lunar terrain and latitude. Heat rejection is calculated for different radiator tilt angles in a variety of terrain environments. Radiator performance as a function of underside thermal condition is also characterized at lunar latitudes ranging from equatorial to polar. Impacts of latitude and terrain on radiator performance are quantified, and regions are identified where the thermal environment is more or less favorable for specific radiator designs.

Lunar Vehicle Radiator↗

Lunar Latitude and Terrain Radiator Sensitivity Study

The thermal environment on the moon is highly complex and diverse. The lunar surface near the equator develops extreme hot average temperatures during the lunar day due to solar flux vectors that are nearly orthogonal to the surface. The lunar poles have a cold and uniquely complex thermal environment with low solar elevation angles and permanently shadowed regions located just kilometers from some of the most highly illuminated regions of the moon. Likewise, the topography can range from very flat crater basins to dramatically tall features such as mountains and crater rims. Consequently, when sizing the radiators of a lunar surface vehicle, the specific thermal environment found in the targeted landing or deployment zone must be well understood to build robust, appropriately scaled thermal control systems. Here described are parametric studies that characterize the sensitivity of lunar radiator performance to lunar terrain and latitude. Heat rejection is calculated for different radiator tilt angles in a variety of terrain environments. Radiator performance as a function of underside thermal condition is also characterized at lunar latitudes ranging from equatorial to polar. Impacts of latitude and terrain on radiator performance are quantified, and regions are identified where the thermal environment is more or less favorable for specific radiator designs.

Lunar Thermal Analysis↗

Lunar Latitude and Terrain Radiator Sensitivity Study

The thermal environment on the moon is highly complex and diverse. The lunar surface near the equator develops extreme hot average temperatures during the lunar day due to solar flux vectors that are nearly orthogonal to the surface. The lunar poles have a cold and uniquely complex thermal environment with low solar elevation angles and permanently shadowed regions located just kilometers from some of the most highly illuminated regions of the moon. Likewise, the topography can range from very flat crater basins to dramatically tall features such as mountains and crater rims. Consequently, when sizing the radiators of a lunar surface vehicle, the specific thermal environment found in the targeted landing or deployment zone must be well understood to build robust appropriately scaled thermal control systems. Here described are parametric studies that characterize the sensitivity of lunar radiator performance to lunar terrain and latitude. Heat rejection is calculated for different radiator tilt angles in a variety of terrain environments. Radiator performance as a function of underside thermal condition is also characterized at lunar latitudes ranging from equatorial to polar. Impacts of latitude and terrain on radiator performance are quantified, and regions are identified where the thermal environment is more or less favorable for specific radiator designs.

Lunar Vehicle Radiator↗

Modernizing the Legacy Fission Wire Measurement System for the Advanced Test Reactor-Critical Facility

Operational lifetime extensions of existing research reactors have emphasized the need for refurbishment, replacements, and upgrades to supporting equipment and instrumentation. The Advanced Test Reactor (ATR) at Idaho National Laboratory (INL), which entered service in 1967, has recently completed the sixth core internals change-out and has scheduled operations until at least 2040. Reactor maintenance and operational risk management is critically important in the research reactor community, however supporting measurement systems sometimes get overlooked when maintenance is planned. The Fission Wire Measurement System (FWMS) is a custom measurement system designed in the 1960s to measure the beta-particle activity of irradiated uranium-aluminum fission wires. This measurement is conducted to determine the fission rate profile of the Advanced Reactor Test Critical (ATR-C) facility. The ATR-C is an open-pool, low-power test reactor that was purpose driven to resemble ATR and is used to qualify experiment configurations and verify core models prior to full-power experiment irradiations in ATR. A power distribution measurement in ATR-C uses uranium-aluminum wires that are distributed throughout the ATR-C core to validate simulation and modeling results. These measurements require 340 to 1500 wires to be irradiated and measured within a 12-hour window. The activity of the wires is measured in the required time with the FWMS, which was put into service in 1965 at the Radiation Measurements Laboratory (RML). The system consists of 4 measurement channels and one reference channel, each with a 2-pi proportional gas flow detector and the measurement channels each have an automated sample changer. This legacy system is crucial to the continued operations of ATR and has undergone some minor hardware upgrades since 1965, however the system presently relies on custom control boards, custom gas ion chambers, analog amplifiers/discriminators, and a user interface (UI) for the system written in outdated code. Much of the equipment and software is custom with no commercial replacements or support and limited documentation. The existing control software requires an operating system that is no longer supported, creating more vulnerabilities to continued operations. A project is underway with a third-party vendor to design, build, and document a new control and data acquisition system (CDAS) for the FWMS. The new upgrade will replace the control system, computer, UI, sample changer motors, and main power supply while maintaining the interface with existing detector hardware. The upgraded system will be operated in parallel with the current hardware and software to conduct validation testing. This equipment upgrade demonstrates the commitment at ATR to ensuring successful operations and potential future research reactors at INL.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Environmental control and air distribution system and method of using the same

An indoor environmental control and air distribution system for a building includes: an air handling unit; a manifold connected to the air handling unit having a chamber formed by a plurality of walls and a plurality of orifices formed through at least one of the walls; air distribution conduits each independently having a first end connected to the orifices of the manifold and a second end extending out from the manifold into different zones throughout the building; and an airflow modulating device having one or more airflow regulating dampers independently configured to move into at least two positions in which each position provides a different percentage of total air volume to each air distribution conduit. A method of using the indoor environmental control and air distribution system is also included.

Poerschke, Andrew↗

Environmental control and air distribution system and method of using the same

An indoor environmental control and air distribution system for a building includes: an air handling unit; a manifold connected to the air handling unit having a chamber formed by a plurality of walls and a plurality of orifices formed through at least one of the walls; air distribution conduits each independently having a first end connected to the orifices of the manifold and a second end extending out from the manifold into different zones throughout the building; and an airflow modulating device having one or more airflow regulating dampers independently configured to move into at least two positions in which each position provides a different percentage of total air volume to each air distribution conduit. A method of using the indoor environmental control and air distribution system is also included.

Poerschke, Andrew↗

Virtual storage capability of residential buildings for sustainable smart city via model-based predictive control

This paper evaluates the virtual storage capability of a residential air-conditioning (AC) system by utilizing the building mass as a thermal storage to enable sustainable cities through model-based predictive control (MPC). The control-oriented building model was developed with a grey-box model structure based on the experimental data to predict the indoor air temperature. Based on the model, the operation cost-saving potential of the MPC was investigated in a single house with different comfort levels, electricity prices, and prediction horizons. The cost-saving of the MPC was approximately 10.6 % compared to the conventional control. The MPC was expanded to a residential building cluster considering the peak demand charge. In an hourly shedding and load-up scenario, the performances of the MPC and the heuristic prior-based control (PBC) are promising. When shedding was enforced all day, the peak demand saving of the MPC was 36~38 %, whereas that of the PBC was 25.7 % compared to the baseline. In addition, the monthly electricity bill, including the operation and peak demand cost, was investigated with different demand charge rates and weather conditions. The total saving decreased with a low demand charge rate and hot conditions, and the operation cost saving was compromised with more aggressive demand shedding.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparing the economic performance of ice storage and batteries for buildings with on-site PV through model predictive control and optimal sizing

Integrating renewable energy and energy storage systems provides a way of operating the electrical grid system more energy efficiently and stably. Thermal storage and batteries are the most common devices for integration. However, it is not clear which integrated storage system performs better in terms of overall economics. Ice storage has low initial and maintenance costs, but there is an efficiency penalty for charging of storage and it can only shift electrical loads associated with building cooling requirements. A battery's round-trip efficiency, on the contrary, is quite consistent and batteries can be used to shift both HVAC and non-HVAC loads. However, batteries have greater initial costs and a shorter life. Finally, this research presents a tool, using model predictive control and optimal sizing, and provides a case study for comparing life-cycle economics of battery and ice storage systems for commercial buildings that have chillers for cooling and an on-site photovoltaic system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Spacecraft Cabin Air Quality Control and Its Application to Tight Buildings

Air quality is an important consideration not only for the external environment, but also for the indoor environment. Most people spend a majority of their lives indoors and the air that they breathe is important to their physical and emotional well being. Since most modern building designs have focused on energy efficiency, less fresh air is brought from the outside. As a result, pollutants from building materials, furniture, cleaning, and cooking have no place to go. To make matters worse, most ventilation systems do not include any means for removing pollutants from the recycled air. Unfortunately, pollution at even a small level can result in eye, throat, and lung irritation in addition to chronic headaches, nausea, and fatigue. A spacecraft cabin, which represents the worst case in tight building design, requires special consideration of air quality since any effects pollutants may have on a crewmember can potentially place a mission or other crewmembers at risk. A detailed approach has been developed by the National Aeronautics and Space Administration (NASA) to minimize cabin atmosphere pollution and provide the crew with an environment which is as free of pollutants as possible. This approach is a combination of passive and active contamination control concepts involving the evaluation and selection of materials to be used onboard the spacecraft, the establishment of air quality standards to ensure crew health, and the use of active control means onboard the spacecraft to further ensure an acceptable atmosphere. This approach has allowed NASA to prevent illness by providing crewmembers with a cabin atmosphere which contains pollutant concentrations up to 100 times lower than those specified for terrestrial indoor environments. Standard building construction, however, does not take into account the potentially harmful effects of materials used in the construction process on the health of future occupants and relies primarily on remedial rather than preventive techniques when addressing contamination. This approach results in a building that theoretically has low operating costs, but may actually have high costs associated with lost work days, increased medical claims, decreased productivity, and problem remediation. A similar approach to NASA's may be adopted by the building construction community which can tap the extensive database of material offgassing properties that has been collected to support the space program. Many materials used by NASA are commercially available and are frequently used in building construction. In addition, computer models which have been developed for assessing various methods of active contamination control can be applied to building ventilation system design and the analysis of their economics. Through using NASA' s experience, the expense associated with the current remedial approach can be avoided.

Perry, J. L.↗

Development of a water source heat pump hardware-in-the-loop (HIL) testing facility for smart building applications

Over the last decade, the global fight against climate change through electrification has led to an increase in research on building heating, ventilation, and air conditioning (HVAC) systems that utilize intelligent control algorithms to provide demand-side grid service while maintaining the thermal comfort of building occupants. As the pivotalpoint between building electricity consumption and indoor thermal comfort, high-efficiency electrical heatpumps are at the center of these emerging studies, and various grid-interactive and occupant-comfort control algorithms have been developed for them. The impact of these algorithms on the heatpump operation andperformance under different weather, building load, and grid requests calls for investigation and verification via experimental tests with actual heat pumps integrated with real-time building and grid responses. This study presents a Water-Source Heat Pump Hardware-in-The-Loop (HIL) Test Facility developed with the capability to perform such tests. The hardware configuration for this testfacility introduces a hydronic system that emulates the conditions for the heat pump water-side, and a duct system that emulates conditions for the heat pump airside. Both data acquisition and emulator control are implemented through the National Instruments (NI) LabVIEW software running on an NI PXIplatform. The HIL mechanism based on the hardware-software integration that allows the testbed to communicate with a generic simulation environment is also discussed. Currently, the test facility setup includes a single heatpump and virtual building model in EnergyPlus coupled with an occupant behavioral model in MATLAB. Preliminary test results of the current setup demonstrate the building load emulator's ability to track the simulated gone temperature with a Root Mean Square Deviation (RSME) below 0.12°C (0.216°F). An uncertainty analysis based on sensor accuracies shows that the heat pump coefficient of performance (COP) can be measured with a relative uncertainty of 10.4% in cooling and 3.7% in heating. Apartfrom the current testing on a single heat pump, the test facility also provides the flexibility to include additional heat pumps to form a heat pump cluster, as well as coupling the heat pump with active thermal storage to provide enhanced demandflexibility.

Calfa, Caleb↗