Search NASA⌕ Search

SEARCH · Search NASA

Results for “buildings”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

A comparison of wake characteristics of model and prototype buildings in transverse winds

Previously measured mean velocity and turbulence intensity profiles in the wake of a 26.8-m long building 3.2 m high and transverse to the wind direction in an atmospheric boundary layer several hundred meters thick were compared with profiles at corresponding stations downstream of a 1/50-scale model on the floor of a large meteorological wind tunnel in a boundary layer 0.61 m in thickness. The validity of using model wake data to predict full scale data was determined. Preliminary results are presented which indicate that disparities result from differences in relative depth of logarithmic layers, surface roughness, and the proximity of upstream obstacles.

Logan, E., Jr.↗

Concorde noise-induced building vibrations: John F. Kennedy International Airport

Outdoor and indoor noise levels resulting from aircraft flyovers and certain nonaircraft events were recorded at eight homesites and a school along with the associated vibration levels in the walls, windows, and floors at these test sites. Limited subjective tests were conducted to examine the human detection and annoyance thresholds for building vibration and rattle caused by aircraft noise. Both vibration and rattle were detected subjectively in several houses for some operations of both the Concorde and subsonic aircraft. Seated subjects more readily detected floor vibrations than wall or window vibrations. Aircraft noise generally caused more window vibrations than common nonaircraft events such as walking and closing doors. Nonaircraft events and aircraft flyovers resulted in comparable wall vibration levels, while floor vibrations were generally greater for nonaircraft events than for aircraft flyovers. The relationship between structural vibration and aircraft noise is linear, with vibration levels being accurately predicted from overall sound pressure levels (OASPL) measured near the structure. Relatively high levels of structural vibration measured during Concorde operations are due more to higher OASPL levels than to unique Concorde-source characteristics.

Mayes, W. H.↗

JPL Energy Consumption Program (ECP) documentation: A computer model simulating heating, cooling and energy loads in buildings

The engineering manual provides a complete companion documentation about the structure of the main program and subroutines, the preparation of input data, the interpretation of output results, access and use of the program, and the detailed description of all the analytic, logical expressions and flow charts used in computations and program structure. A numerical example is provided and solved completely to show the sequence of computations followed. The program is carefully structured to reduce both user's time and costs without sacrificing accuracy. The user would expect a cost of CPU time of approximately $5.00 per building zone excluding printing costs. The accuracy, on the other hand, measured by deviation of simulated consumption from watt-hour meter readings, was found by many simulation tests not to exceed + or - 10 percent margin.

Lansing, F. L.↗

Solar heating and cooling system for an office building at Reedy Creek Utilities

The solar energy system installed in a two story office building at a utilities company, which provides utility service to Walt Disney World, is described. The solar energy system application is 100 percent heating, 80 percent cooling, and 100 percent hot water. The storage medium is water with a capacity of 10,000 gallons hot and 10,000 gallons chilled water. Performance to date has equaled or exceeded design criteria.

Source record↗

Learning to build large structures in space

The paper examines some of the key technologies and forms of construction know-how that will have to be developed and tested for eventual application to building large structures in space. Construction of a shuttle-tended space construction/demonstration platform would comprehensively demonstrate large structure technology, develop construction capability, and furnish a construction platform for a variety of operational large structures. Completion of this platform would lead to demonstrations of the Satellite Power System (SPS) concept, including microwave transmission, fabrication of 20-m-deep beams, conductor installation, rotary joint installation, and solar blanket installation.

Hagler, T.↗

C/STOL flight in wind disturbed by the presence of buildings

This paper investigates the behavior of winds about block geometries characteristic of building shapes and of the flight performance of aircraft with characteristics of a DC-8 and a DHC-6 as they fly through the wind fields. The two-dimensional equations of motion for the aircraft are written to include variable winds and wind shear components. The paper also presents a discussion of the influence of those terms in the equations of motion which explicitly contain effects due to wind shear. Also included is a study of the aircrafts' flight paths over the obstacles with both a fixed stick and an automatic landing system.

Frost, W.↗

Ignitability of some insulation and building materials

A variety of insulation and building materials were evaluated for ignitability, using a screening test method developed at the University of San Francisco. Ignitability tended to be greater with the more efficient insulation materials because the insulating qualities resulted in a more rapid rise in temperature at the exposed surface. The use of a noncombustible facing material is recommended to provide protection from surface ignition.

Hilado, C. J.↗

Human Response to Aircraft-Noise-Induced Building Vibration

The effects of noise induced building structure vibration and the rattle of objects on human response to aircraft flyover noise were investigated in a series of studies conducted in both the field and the laboratory. The subjective detection thresholds for vibration and rattle were determined as well as the effect of vibration and rattle upon aircraft noise annoyance.

Cawthorn, J. M.↗

The application of photovoltaic roof shingles to residential and commercial buildings

The recent development of a shingle-type solar-cell module makes it possible to incorporate easily photovoltaic power generation into the sloping roofs of residential or commercial buildings. These modules, which use a closely packed array of nineteen 53-mm-diameter circular solar cells, are capable of producing 101 watts/sq m of module area under standard operating conditions. This module performance is achievable by the use of solar cells with an average efficiency of 13.3 percent at 1 kW/sq m air-mass-1.5 insolation and at a cell temperature of 28 C. When these modules are mounted on a sloping south-facing roof which is insulated on the rear surface, the annual energy generated at the maximum power operating point will vary from 255.6 to 137.3 kWh/sq m of module area depending on the site location, with Albuquerque, NM, and Seattle, WA, representing the highest and lowest values of the thirteen sites considered.

Shepard, N. F., Jr.↗

A study of standard building blocks for the design of fault-tolerant distributed computer systems

This paper presents the results of a study that has established a standard set of four semiconductor VLSI building-block circuits. These circuits can be assembled with off-the-shelf microprocessors and semiconductor memory modules into fault-tolerant distributed computer configurations. The resulting multi-computer architecture uses self-checking computer modules backed up by a limited number of spares. A redundant bus system is employed for communication between computer modules.

Rennels, D. A.↗

Fault tolerance using self-checking building-block computers

The paper attempts to define and characterize a set of VLSI (very large scale integration) building-block circuits which can be used to combine existing microprocessors and memories into a wide variety of fault-tolerant computing systems. Such VLSI circuits would transform fault-tolerant computing into an off-the-shelf technology and enable its routine use for new applications. The self-checking computer module (SCCM) is the basic component out of which fault-tolerant computer systems are constructed. Several fault-tolerant configurations of SCCM are discussed, including the standby redundant uniprocessor, the voted/hybrid uniprocessor, and the distributed computer network.

Rennels, D. A.↗

Solar--heated and cooled office building--Dalton, Georgia

Modern energy efficient building is heated and cooled by five rows of flat plate solar collectors; its domestic hot water needs are also met. Final report includes detailed drawings and photographs, manufacturer's literature, performance specifications, acceptance test data, and performance verification statements. Operation and maintenance manual is also attached.

Source record↗

Solar-energy landmark Building-Columbia, Missouri

Report includes design, cost, installation, maintenance, and performance details for attractive solar installation which supplies space heating for four-story Visitors Center. 176 hydronic flat-plate collectors, water-to-water heat exchanger, and 5,000-gallon storage tank comprise system which provides 71 percent of building's heat. Natural-gas-fired boiler supplies auxiliary hot water to heating system when necessary.

Source record↗

Building with integral solar-heat storage--Starkville, Mississippi

Column supporting roof also houses rock-storage bin of solar-energy system supplying more than half building space heating load. Conventional heaters supply hot water. Since bin is deeper and narrower than normal, individual pebble size was increased to keep airflow resistance at minimum.

Source record↗

Solar energy system installed at the North Georgia APDC office building

A hydronic, automatic drain-down solar heating and cooling system is described. The system provides solar heat exchange from a 2,001 square foot effective collector area and supplies 65-70 percent of the building's cooling demand, 90-95 percent of the heating demand, and domestic hot water. The acceptance test plan and results, system operation and maintenance, and predicted system performance are presented.

Source record↗

Subcontracted activities related to TES for building heating and cooling

The subcontract program elements related to thermal energy storage for building heating and cooling systems are outlined. The following factors are included: subcontracts in the utility load management application area; life and stability testing of packaged low cost energy storage materials; and development of thermal energy storage systems for residential space cooling. Resistance storage heater component development, demonstration of storage heater systems for residential applications, and simulation and evaluation of latent heat thermal energy storage (heat pump systems) are also discussed. Application of thermal energy storage for solar application and twin cities district heating are covered including an application analysis and technology assessment of thermal energy storage.

Martin, J.↗

Improving Building Construction Specifications in State and Local Governments

State and local governments can benefit from master specifications systems that centralize data on all types of building materials, products, and processes. Most of these systems are organized according to the MASTERFORMAT system, which, along with guide specifications that require the insertion or deletion of standardized information, resulted from the specific needs of users and providers. For jurisdictions preparing their own specifications, staff time and cost are reduced. For those subcontracting the preparation, master specifications provide a means of evaluating the specifications submitted. Current management specification systems described include SPECINTACT, OMSPEC, MASTERPEC, and the NAVFAC, Corps of Engineers, and GSA guide specifications.

Source record↗