Search NASA⌕ Search

SEARCH · Search NASA

Results for “calibration interferometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Investigating the Martian Environment with the Mars Global Surveyor Thermal Emission Spectrometer

The Thermal Emission Spectrometer (TES) onboard Mars Global Surveyor (MGS) is being used to investigate the surface and atmosphere of Mars and the martian moons Phobos and Deimos. As such, it builds upon infrared observations obtained by previous spacecraft, e.g.. Mariner 9 and Viking Orbiters. The objectives of the TES experiment are: (1) determine and map surface minerals. rocks. and ices; (2) study the atmospheric dust composition. particle size, and spatial and temporal distribution; (3) investigate condensate clouds, CO2 and H2O, location. temperature, and height; (4) investigate polar cap deposits, e.g., growth, retreat, and energy balance; (5) measure the thermo-physical properties of surface materials; and (6) characterize the atmospheric structure and dynamics. The TES instrument is based upon a Michelson interferometer and collects data in the 1700-200 per cm region (about 6-50 micron at 5 or 10 per cm resolution. There are also broad-band bolometric (4.5100 microns and solar reflectance (0.3-2.7 microns) channels. The TES was designed to have a noise equivalent spectral radiance of 1.2 x l0(exp -8) per W per square cm per sr per cm corresponding to a signal-to-noise ratio of 490 at 1000 per cm (10 mm) for a 270 K scene and preflight data suggest a radiometric accuracy of about 1.2 x 10(exp -8) per W per square cm per sr per cm. In-flight observations indicate a small systematic calibration offset of about 1.2 x 10(exp -7) per W per square cm per sr per cm is present in the TES data. MGS achieved Mars orbital insertion September 11, 1997, and entered the initial aerobraking phase. MGS should have reached a circular orbit by early 1998. However, structural damage to one solar panel occurred during its deployment in the cruise phase and ultimately required an assessment of the extent of the damage and a much slower aerobraking period. This has delayed reaching the final circular orbit until March 1999. TES and the other MGS science instruments began operating just after orbital insertion and continued to obtain data until November 1998 when the TES was turned off to reduce power consumption on the spacecraft. TES data obtained during orbits 2 to 53 have previously been published and clearly illustrate the variety of scientific questions that can be addressed with them.

Roush, T. L.↗

Verification Challenges of Dynamic Testing of Space Flight Hardware

The Six Degree-of-Freedom Dynamic Test System (SDTS) is a test facility at the National Aeronautics and Space Administration (NASA) Johnson Space Center in Houston, Texas for performing dynamic verification of space structures and hardware. Some examples of past and current tests include the verification of on-orbit robotic inspection systems, space vehicle assembly procedures and docking/berthing systems. The facility is able to integrate a dynamic simulation of on-orbit spacecraft mating or demating using flight-like mechanical interface hardware. A force moment sensor is utilized for input to the simulation during the contact phase, thus simulating the contact dynamics. While the verification of flight hardware presents many unique challenges, one particular area of interest is with respect to the use of external measurement systems to ensure accurate feedback of dynamic contact. There are many commercial off-the-shelf (COTS) measurement systems available on the market, and the test facility measurement systems have evolved over time to include two separate COTS systems. The first system incorporates infra-red sensing cameras, while the second system employs a laser interferometer to determine position and orientation data. The specific technical challenges with the measurement systems in a large dynamic environment include changing thermal and humidity levels, operational area and measurement volume, dynamic tracking, and data synchronization. The facility is located in an expansive high-bay area that is occasionally exposed to outside temperature when large retractable doors at each end of the building are opened. The laser interferometer system, in particular, is vulnerable to the environmental changes in the building. The operational area of the test facility itself is sizeable, ranging from seven meters wide and five meters deep to as much as seven meters high. Both facility measurement systems have desirable measurement volumes and the accuracies vary within the respective volumes. In addition, because this is a dynamic facility with a moving test bed, direct line-of-sight may not be available at all times between the measurement sensors and the tracking targets. Finally, the feedback data from the active test bed along with the two external measurement systems must be synchronized to allow for data correlation. To ensure the desired accuracy and resolution of these systems, calibration of the systems must be performed regularly. New innovations in sensor technology itself are periodically incorporated into the facility s overall measurement scheme. In addressing the challenges of the measurement systems, the facility is able to provide essential position and orientation data to verify the dynamic performance of space flight hardware.

Winnitoy, Susan↗

SIM Configuration Evolution

The Space Interferometry Mission (SIM) is a space-based 10 m baseline Michelson interferometer. Planned for launch in 2005 aboard a Delta III launch vehicle, or equivalent, its primary objective is to measure the positions of stars and other celestial objects with an unprecedented accuracy of 4 micro arc seconds. With such an instrument, tremendous advancement can be expected in our understanding of stellar and galactic dynamics. Using triangulation from opposite sides of the orbit around the sun (i.e. by using parallax) one can measure the distance to any observable object in our galaxy. By directly measuring the orbital wobble of nearby stars, the mass and orbit of planets can be determined over a wide range of parameters. The distribution of velocity within nearby galaxies will be measurable. Observations of these and other objects will improve the calibration of distance estimators by more than an order of magnitude. This will permit a much better determination of the Hubble Constant as well as improving our overall understanding of the evolution of the universe. SIM has undergone several transformations, especially over the past year and a half since the start of Phase A. During this phase of a project, it is desirable to perform system-level trade studies, so the substantial evolution of the design that has occurred is quite appropriate. Part of the trade-off process has addressed two major underlying architectures: SIM Classic; and Son of SIM. The difference between these two architectures is related to the overall arrangement of the optical elements and the associated metrology system. Several different configurations have been developed for each architecture. Each configuration is the result of design choices that are influenced by many competing considerations. Some of the more important aspects will be discussed. The Space Interferometry Mission has some extremely challenging goals: millikelvin thermal stability, nanometer stabilization of optics, picometer measurement of wavefront, and others. In order to meet these goals, a significant amount of technological development is required. Although there has been a program operating for about a decade developing technologies specifically to address the challenges of space-based interferometry, there still remains a tremendous effort to achieve the incredible accuracy required of SIM. The projected viability of some of these areas has influenced design choices during the evolution of the many configurations that have been developed. For instance, the perceived complexity of the IR laser metrology system used to measure and control the positions of key optical elements was the strongest discriminator between the two architectures, and led to a decision to select SOS rather than Classic in early 1998. More recently, an appreciation of the sensitivity to beam-walk within the SOS architecture is forcing a reconsideration of that decision. At the time of submission of this abstract, there is some hope that a full-aperture metrology system may alleviate this issue. In addition to describing the current configuration of SIM, the influence of a few selected areas on the evolution of the configuration will be discussed.

Aaron, Kim M.↗

Machine Straightness Error Measurement Based on Optical Fiber Fabry–Pérot Interferometer Monitoring Technique

Abstract In this research, we propose an Error Separation Technique (EST) based on optical fiber sensors for on-machine straightness error measurement. Two fiber optic Fabry–Pérot interferometers have been developed serving as two displacement sensors. The displacement distance is computed according to the reflected spectrum from interferometers, which can achieve a sub-micrometer resolution. The two-point method has been employed to separate the straightness error of the slides and the profile error of a fine-polished standard block. The spacing distance between two interferometers is determined by the diameter of optical fibers so that the EST's resolution has the potential to reach the sub-millimeter scale. In the experiment, the straightness error has been measured on a commercially available computer numerical control machine tool, and the measurement has been conducted on its x-axis. The spacing distance between two optical fiber sensors is 1.5 mm which equals the EST's resolution along the machine tool's x-axis. The separated profile error of the measured standard block is around 30 µm which has been verified by a high precision Coordinate Measurement Machine (CMM). The magnitude of the separated straightness error is around 40 µm. This technique is flexible and simple to be conducted, which can contribute to the micro-machine tool calibration and other straightness error applications.

Engineering↗

CubeSat Infrared Atmospheric Sounder (CIRAS) NASA InVEST Technology Demonstration

Infrared sounders measure the upwelling radiation of the Earth in the Midwave Infrared (MWIR) and Longwave Infrared (LWIR) region of the spectrum with global daily coverage from space. The observed radiances are assimilated into weather forecast models and used to retrieve lower tropospheric temperature and water vapor for climate studies. There are several operational sounders today including the Atmospheric Infrared Sounder (AIRS) on Aqua, the Crosstrack Infrared Sounder (CrIS) on Suomi NPP and JPSS, and the Infrared Atmospheric Sounding Interferometer (IASI) on the MetOp spacecraft. The CubeSat Infrared Atmospheric Sounder (CIRAS) is a NASA In-flight Validation of Earth Science Technologies (InVEST) program to demonstrate three new instrument technologies in an imaging sounder configuration. The first is a 2D array of High Operating Temperature Barrier Infrared Detector (HOT-BIRD) material, selected for its high uniformity, low cost, low noise and higher operating temperatures than traditional materials. The detectors are hybridized to a commercial ROIC and commercial camera electronics. The second technology is a MWIR Grating Spectrometer (MGS) designed to provide imaging spectroscopy for atmospheric sounding in a CubeSat volume. The MGS employs an immersion grating or grism, has no moving parts, and is based on heritage spectrometers including the OCO-2. The third technology is a Black Silicon infrared blackbody calibration target. The Black Silicon offers very low reflectance over a broad spectral range on a flat surface and is more robust than carbon nanotubes. JPL will also develop the mechanical, electronic and thermal subsystems for the CIRAS payload. The spacecraft will be a commercially available CubeSat. The integrated system will be a complete 6U CubeSat capable of measuring temperature and water vapor profiles with good lower tropospheric sensitivity. The low cost of CIRAS enables multiple units to be flown to improve temporal coverage or measure 3D Atmospheric Motion Vector (AMV) winds. CIRAS will launch in 2019 and is only a technology demonstration. However, what we learn will benefit future instruments that support operational weather forecasting and climate studies.

Pagano, Thomas S.↗

The Re-Analysis of Ozone Profile Data from a 41-Year Series of SBUV Instruments

In this study we present the validation of ozone profiles from a number of Solar Back Scattered Ultra Violet (SBUV) and SBUV/2 instruments that were recently reprocessed using an updated (Version 8.6) algorithm. The SBUV dataset provides the longest available record of global ozone profiles, spanning a 41-year period from 1970 to 2011 (except a 5-year gap in the 1970s) and includes ozone profile records obtained from the Nimbus-4 BUV and Nimbus-7 SBUV instruments, and a series of SBUV(/2) instruments launched on NOAA operational satellites (NOAA 09, 11, 14, 16, 17, 18, 19). Although modifications in instrument design were made in the evolution from the BUV instrument to the modern SBUV(/2) model, the basic principles of the measurement technique and retrieval algorithm remain the same. The long term SBUV data record allows us to create a consistent, calibrated dataset of ozone profiles that can be used for climate studies and trend analyses. In particular, we focus on estimating the various sources of error in the SBUV profile ozone retrievals using independent observations and analysis of the algorithm itself. For the first time we include in the metadata a quantitative estimate of the smoothing error, defined as the error due to profile variability that the SBUV observing system cannot inherently measure. The magnitude of the smoothing error varies with altitude, latitude, season and solar zenith angle. Between 10 and 1 hPa the smoothing errors for the SBUV monthly zonal mean retrievals are of the order of 1 %, but start to increase above and below this layer. The largest smoothing errors, as large as 15-20%, were detected in in the troposphere. The SBUV averaging kernels, provided with the ozone profiles in version 8.6, help to eliminate the smoothing effect when comparing the SBUV profiles with high vertical resolution measurements, and make it convenient to use the SBUV ozone profiles for data assimilation and model validation purposes. The smoothing error can also be minimized by combining layers of data, and we will discuss recommendations for this approach as well. The SBUV ozone profiles have been intensively validated against satellite profile measurements obtained from the Microwave Limb Sounders (MLS) (on board the UARS and AURA satellites), Stratospheric Aerosol and Gas Experiment (SAGE) and Michelson Interferometer for Passive Atmospheric Sounding (MIPAS). Also, we compare coincident and collocated SBUV ozone retrievals with observations made by ground-based instruments, such as microwave spectrometers, lidars, Umkehr instruments and balloon-borne ozonosondes. Finally, we compare the SBUV ozone profiles with output from the NASA GSFC GEOS-CCM model. In the stratosphere between 25 and 1 hPa the mean biases and standard deviations are within 5% for monthly mean ozone profiles. Above and below this layer the vertical resolution of the SBUV algorithm decreases and the effects of vertical smoothing should be taken into account. Though the SBUV algorithm has a coarser vertical resolution in the lower stratosphere and troposphere, it is capable of precisely estimating the integrated ozone column between the surface and 25 hPa. The time series of the tropospheric - lower stratospheric ozone column derived from SBUV agrees within 5% with the corresponding values observed by an ensemble of ozone sonde stations in North Hemisphere. Drift of the ozone time series obtained from each SBUV(/2) instrument relative to ground based and satellite measurements are evaluated and some features of individual SBUV(l2) instruments are discussed. In addition to evaluating individual instruments against independent observations, we also focus on the instrument to instrument consistency in the series. Overall, Version 8.6 ozone profiles obtained from two different SBUV(l2) instruments compare within a couple of percent during overlap periods and are consistently varying in time, with some exceptions. Some of the noted discrepancies might bssociated with ozone diurnal variations, since the difference in the local time of the observations for a pair of SBUV(l2) instruments could be several hours. Other issues include the potential short-term drift in measurements as the instrument orbit drifts, and measurements are obtained at high solar zenith angles (>85 ). Based on the results of the validation, a consistent, calibrated dataset of SBUV ozone profiles has been created based on internal calibration only.

Kramarova, Natalya↗

Precise Measurement of Carbon Dioxide Column by Passive Ground Based Sensor

Over the past four years we have developed a family of differential radiometers based upon the Fabry-Perot interferometers that exhibit very great sensitivity to changes in the atmospheric column of carbon dioxide, oxygen, and water vapor. Our instruments employ a solid Fabry-Perot etalon that is tuned to the proper wavelength by changing its temperature. The thickness of the etalon has been selected so that its multiple pass bands align with regularly space absorption features of the molecule under investigation. Using multiple absorption features improves the optical throughput of the instrument and improves the stability of the instrument response with respect to environmental changes. We are presently working to extend this technique to the carbon 13 isotope of carbon dioxide and to methane. Our instruments are intrinsically rugged and can be fabricated in a small package at relatively low cost.. As such they hold promise for widespread use in ground based networks for calibration and validation of satellite instruments such as OCO and GOSAT. Results will be presented for long term ground based operations of these systems. The effects of atmospheric scattering, pointing errors, pressure broadening and temperature effects will be discussed with regard to achieving precision better than .5% required for validation of carbon dioxide column measured from space. Finally we will outline the approach for extension of this methodology to additional molecular species of interest.

Heaps, William S.↗

Nulling Data Reduction and On-Sky Performance of the Large Binocular Telescope Interferometer

The Large Binocular Telescope Interferometer (LBTI) is a versatile instrument designed for high angular resolution and high-contrast infrared imaging (1.5-13 micrometers). In this paper, we focus on the mid-infrared (8-13 micrometers) nulling mode and present its theory of operation, data reduction, and on-sky performance as of the end of the commissioning phase in 2015 March. With an interferometric baseline of 14.4 m, the LBTI nuller is specifically tuned to resolve the habitable zone of nearby main-sequence stars, where warm exozodiacal dust emission peaks. Measuring the exozodi luminosity function of nearby main-sequence stars is a key milestone to prepare for future exo-Earth direct imaging instruments. Thanks to recent progress in wavefront control and phase stabilization, as well as in data reduction techniques, the LBTI demonstrated in 2015 February a calibrated null accuracy of 0.05% over a 3 hr long observing sequence on the bright nearby A3V star Beta Leo. This is equivalent to an exozodiacal disk density of 15-30 zodi for a Sun-like star located at 10 pc, depending on the adopted disk model. This result sets a new record for high-contrast mid-infrared interferometric imaging and opens a new window on the study of planetary systems.

circumstellar matter aEuro" techniques: interferom↗

Field Results from New Tensor Borehole Optical Fiber Strainmeter Installations in Oklahoma and Utah

The time evolving strain field contains a wealth of information that can be used to interpret subsurface behavior. For example, injecting or removing fluids from reservoirs or aquifers causes deformation that can be used as a diagnostic signal in some cases, while it can interfere with geodetic interpretations in other cases. We've previously demonstrated the feasibility of measuring the strain tensor at a depth of 30m caused by injection into a reservoir at 530m. The observed strain signals were interpreted using four independent analytic and numerical methods that resulted in estimates of the poroelastic properties and geometry of the reservoir that was consistent with data from well logs. However, studies like these are only possible if these deformations can be reliably measured. Years of lab and field work has culminated in the development of a novel borehole strainmeter capable of resolving multiple components of strain using embedded optical fibers configured as Michelson interferometers. It features four horizontal gauges separated by 45° to resolve the horizontal strain tensor as well as a vertical strain gauge and a sixth null component for state-of-health monitoring. The downhole sensing package also includes an open pipe through its center for grout circulation during single-trip deployments and a fully welded stainless steel exterior for robustness and longevity. These instruments have a resolution of 2x10-13 strain that can easily measure the solid earth tides. Preliminary data are available from four strainmeters in shale at our Oklahoma site and four in compacted sand and gravel in Utah. These are deployed from 40-60m, except one of the strainmeters in Oklahoma is deployed at 500m. The data include strains from the initial grout curing, comparisons to predicted earth tide models and in-situ calibration results, barometric pressure admittances and spectral analyses as well as signals from underground injections and surface waves from teleseismic events. Preliminary analyses indicate behavior consistent with other strainmeter deployments, and comparison to data from a Gladwin strainmeter at the Oklahoma site validate the performance of the new design. Analyses from a suite of six well tests at the Oklahoma site show for the first time how the strain tensor field varies with location during well testing.

DeWolf, Scott↗

Fabry-Perot Based Radiometers for Precise Measurement of Greenhouse Gases

Differential radiometers based upon the Fabry-Perot interferometer have been developed and demonstrated that exhibit very great sensitivity to changes in the atmospheric column of carbon dioxide, oxygen, and water vapor. These instruments employ a solid Fabry-Perot etalon that is tuned to the proper wavelength by changing the temperature. By choosing the thickness of the etalon its multiple pass bands can be made to align with regularly space absorption features of the molecule under investigation. Use of multiple absorption features improves the optical throughput of the instrument and improves the stability of the instrument response with respect to environmental changes. Efforts are underway at Goddard to extend this technique to the carbon 13 isotope of carbon dioxide and to methane. These instruments are intrinsically rugged and can be made rather small and inexpensively. They therefore hold promise for widespread use in ground based networks for calibration of satellite instruments such as OCO and GOSAT. Results will be presented for ground based and airborne operations for these systems. The effects of atmospheric scattering, pointing errors, pressure broadening and temperature effects will be discussed with regard to achieving precision better than .5% required for validation of carbon dioxide column measured from space. Designs permitting the extension of the technique to an even larger number of atmospheric species will be discussed along with theoretical analysis of potential system performance.

Heaps, William S.↗

Octofitter: Fast, Flexible, and Accurate Orbit Modeling to Detect Exoplanets

As next-generation imaging instruments and interferometers search for planets closer to their stars, they must contend with increasing orbital motion and longer integration times. These compounding effects make it difficult to detect faint planets but also present an opportunity. Increased orbital motion makes it possible to move the search for planets into the orbital domain, where direct images can be freely combined with the radial velocity and proper motion anomaly, even without a confirmed detection in any single epoch. In this paper, we present a fast and differentiable multimethod orbit-modeling and planet detection code called Octofitter. This code is designed to be highly modular and allows users to easily adjust priors, change parameterizations, and specify arbitrary function relations between the parameters of one or more planets. Octofitter further supplies tools for examining model outputs including prior and posterior predictive checks and simulation-based calibration. We demonstrate the capabilities of Octofitter on real and simulated data from different instruments and methods, including HD 91312, simulated JWST/NIRISS aperture masking interferometry observations, radial velocity curves, and grids of images from the Gemini Planet Imager. We show that Octofitter can reliably recover faint planets in long sequences of images with arbitrary orbital motion. This publicly available tool will enable the broad application of multiepoch and multimethod exoplanet detection, which could improve how future targeted ground- and space-based surveys are performed. Finally, its rapid convergence makes it a useful addition to the existing ecosystem of tools for modeling the orbits of directly imaged planets.

79 ASTRONOMY AND ASTROPHYSICS↗

Phase Doppler Interferometry for Efficient Cloud Drop Size Distribution, Number Density, and LWC Measurements

Threats to aviation safety as a result of super-cooled large drops (SLD) has been addressed by the FAA rules change (14 CFR Part 25) with the additional icing certification requirement. SLD clouds often consist of bi-modal drop size spectra leading to significant problems in simulating and characterizing these conditions in situ and in icing wind tunnels. Legacy instrumentation for measuring drop size distributions and liquid water content are challenged under these conditions. The large size range measurement problem is addressed with the development of the Phase Doppler Interferometer, Flight Probe Dual-Range (PDI FPDR). The method is described in this report along with the measurement capabilities including the dynamic measurement range and overall working size range. The PDI instrument bases drop size measurements on the light wavelength as the measurement length scale. The light wavelength is a much more robust scale, especially as compared to the light scattering intensity. Additionally, methods for accurately characterizing the sample volume in situ based on measured drop velocity and transit time are reviewed, given the importance of this parameter for merging results and measuring LWC. Droplet coincidence in the sample volume can be problematic so this condition is treated with an innovative signal parsing approach. Measurement examples acquired in the NASA IRT are provided. Measurements of LWC showed good agreement with the Artium Particle Imaging (PI) instrument but diverged from the tunnel calibration results for larger MVD values.

42 ENGINEERING↗

Midcourse Space Experiment Data Certification and Technology Transfer

The University of Alabama in Huntsville contributes to the Technical Management of the Midcourse Space Experiment Program, to the Certification of the Level 2 data produced by the Midcourse Space Experiment's suite of in-orbit imaging radiometers, imaging spectra-radiometers and an interferometer and to the Transfer of the Midcourse Space Experiment Technology to other Government Programs. The Technical Management of the Midcourse Space Experiment Program is expected to continue through out the spacecraft's useful life time, 5 years after its 1996 launch. The Transfer of Midcourse Space Experiment Technology to other government elements is expected to be on a demand basis by the United States Government and other organizations. The University of Alabama Huntsville' contribution specifically supports the nine Ultraviolet Visible Imagers and Spectrographic Imagers (UVISI) and the Pointing and Alignment of all eleven of the science instruments. The science instruments effectively cover the 0.1 to 28 micron spectral region. The Midcourse Space Experiment spacecraft, launched April 24, 1996, is expected to have a 5 year useful lifetime with a 12 month lifetime for the cryogenically cooled IR sensor. A pre-launch, ground based calibration of the instruments provided a basis for the pre-launch certification of the Level 2 data base these instruments produce. With the spacecraft in-orbit the certification of the instruments' Level 2 data base is being extended to the in-orbit environment.

Pollock, David B.↗

The Space Interferometry Mission

The Space Interferometry Mission (SIM) is the next major space mission in NASA's Origins program after SIRTF. The SIM architecture uses three Michelson interferometers in low-earth orbit to provide 4 microarcsecond precision absolute astrometric measurements on approx. 40,000 stars. SIM will also provide synthesis imaging in the visible waveband to a resolution of 10 milliarcsecond, and interferometric nulling to a depth of 10(exp -4). A near-IR (1-2 micron) capability is being considered. Many key technologies will be demonstrated by SIM that will be carried over directly or can be readily scaled to future Origins missions such as TPF. The SIM spacecraft will carry a triple Michelson interferometer with baselines in the 10 meter range. Two interferometers act as high precision trackers, providing attitude information at all time, while the third one conducts the science observations. Ultra-accurate laser metrology and active systems monitor the systematic errors and to control the instrument vibrations in order to reach the 4 microarcsecond level on wide-angle measurements. SIM will produce a wealth of new astronomical data. With an absolute positional precision of 4 microarcsecond, SIM will improve on the best currently available measures (the Hipparcos catalog) by 2 or 3 orders of magnitude, providing parallaxes accurate to 10% and transverse velocities to 0.2 km/s anywhere in the Galaxy, to stars as faint as 20th magnitude. With the addition of radial velocities, knowledge of the 6-dimension phase space for objects of interest will allow us to attack a wide array of previously inaccessible problems such as: search for planets down to few earth masses; calibration of stellar luminosities and by means of standard candles, calibration of the cosmic distance scale; detecting perturbations due to spiral arms, disk warps and central bar in our galaxy; probe of the gravitational potential of the Galaxy, several kiloparsecs out of the galactic plane; synthesis imaging of circumstellar disks around young stellar objects; imaging the narrow-line regions of AGNs in the optical; direct distance determination of a half dozen nearby spiral galaxies using rotational kinematics, thereby sidestepping reddening and metallicity issues in the calibration of distance estimators like Tully-Fisher; imaging exozodiacal dust disks (when operating in its nulling mode, SIM will be sensitive, at a distance of (beta) Pic (20 pc), to scales ranging from 0.2 to 5 AU).

Unwin, Stephen C.↗

Absorption Laser Differential Interferometry for Simultaneous Colinear Flow Property and Fluctuation Measurements

An absorption laser differential interferometer (A-LDI) was constructed and tested in an effort to simultaneously and colinearly measure flow properties (pressure, temperature, concentration) and flow fluctuations (changes in optical path length). Whereas typical LDI and focused LDI (FLDI) systems use fixed wavelength lasers as the light source (often either green at approximately 532 nm or red at approximately 630 nm), a tunable 760 nm diode laser was used to probe the A-band absorption spectrum of molecular oxygen. The A-LDI system was used to measure O2 absorption and flow fluctuations in a sub-atmospheric pressure-controlled test cell, with absorption profiles from direct absorption and wavelength modulation absorption matching simulated results, while simultaneously being sensitive to high frequency fluctuations from jets of either compressed air or 100% O2 from a gas bottle. The A-LDI system was also installed at the NASA Langley Research Center Probe Calibration Tunnel to assess the freestream flow state in a Mach 3.5 flow. LDI measurements of the freestream indicated increasing amplitudes of flow fluctuations with increasing stagnation pressure at a fixed stagnation temperature, while absorption results demonstrated sensitivity to freestream pressure changes.

Joshua M. Weisberger↗

Demonstration of Imaging Fourier Transform Spectrometer (FTS) Performance for Planetary and Geostationary Earth Observing

The combination of massively parallel spatial sampling and accurate spectral radiometry offered by imaging FTS makes it extremely attractive for earth and planetary remote sensing. We constructed a breadboard instrument to help assess the potential for planetary applications of small imaging FTS instruments in the 1 - 5 micrometer range. The results also support definition of the NASA Geostationary Imaging FTS (GIFTS) instrument that will make key meteorological and climate observations from geostationary earth orbit. The Planetary Imaging FTS (PIFTS) breadboard is based on a custom miniaturized Bomen interferometer that uses corner cube reflectors, a wishbone pivoting voice-coil delay scan mechanism, and a laser diode metrology system. The interferometer optical output is measured by a commercial infrared camera procured from Santa Barbara Focalplane. It uses an InSb 128x128 detector array that covers the entire FOV of the instrument when coupled with a 25 mm focal length commercial camera lens. With appropriate lenses and cold filters the instrument can be used from the visible to 5 micrometers. The delay scan is continuous, but slow, covering the maximum range of +/- 0.4 cm in 37.56 sec at a rate of 500 image frames per second. Image exposures are timed to be centered around predicted zero crossings. The design allows for prediction algorithms that account for the most recent fringe rate so that timing jitter produced by scan speed variations can be minimized. Response to a fixed source is linear with exposure time nearly to the point of saturation. Linearity with respect to input variations was demonstrated to within 0.16% using a 3-point blackbody calibration. Imaging of external complex scenes was carried out at low and high spectral resolution. These require full complex calibration to remove background contributions that vary dramatically over the instrument FOV. Testing is continuing to demonstrate the precise radiometric accuracy and noise characteristics.

Revercomb, Henry E.↗

Midcourse Space Experiment Data Certification and Technology Transfer

The University of Alabama in Huntsville contributes to the Technical Management of the Midcourse Space Experiment Program, to the Certification of the Level 2 data produced by the Midcourse Space Experiment's suite of in-orbit imaging radiometers, imaging spectro-radiometers and an interferometer and to the Transfer of the Midcourse Space Experiment Technology to other Government Programs. The Technical Management of the Midcourse Space Experiment Program is expected to continue through out the spacecraft's useful life time. The Transfer of Midcourse Space Experiment Technology to other government elements is expected to be on a demand basis by the United States Government and other organizations. The University, of Alabama Huntsville' contribution specifically supports the Principal Investigator's Executive Committee, the Deputy Principal Investigator for Data Certification and Technology Transfer team, the nine Ultraviolet Visible Imagers and Spectrographic Imagers (UVISI) and the Pointing and Alignment of all eleven of the science instruments. The science instruments effectively cover the 0.1 to 28 micron spectral region. The Midcourse Space Experiment spacecraft, launched April 24, 1996, is expected to have a 5 year useful lifetime. The cryogenically cooled IR sensor, SPIRIT III, performed through February, 1997 when its cryogen expired. A pre-launch, ground based calibration of the instruments provided a basis for the pre-launch certification of the Level 2 data base these instruments produce. With the spacecraft in-orbit the certification of the instrument's Level 2 data base was extended to the in-orbit environment.

Pollock, David B.↗

The Tianlai Cylinder Pathfinder Array: System Functions and Basic Performance Analysis

The Tianlai Cylinder Pathfinder is a radio interferometer array designed to test techniques for 21 cm intensity mapping in the post-reionization Universe, with the ultimate aim of mapping the large scale structure of the Universe and measuring cosmological parameters such as the dark energy equation of state. Each of its three parallel cylinder reflectors are oriented in the north-south direction, and the array has a large field of view. As the Earth rotates, the northern sky is observed by drift scanning. The array is located in Hongliuxia, a radio quiet site in Xinjiang, and saw its first light in September 2016. In this first paper on the data analysis of the Tianlai cylinder array, we describe the system functions of the array, the commissioning observations during 2016- 2018, and present its basic performance characteristics. We show examples of the interferometric visibility data, then using the observational data, we derive the actual beam profile in the east-west direction, the bandpass response, and calibrate the complex gains for the array elements either with a strong astronomical point source, or with an artificial calibrator source. Based on the preliminary analysis of the data, we derive the system temperature and sensitivity of the array.

79 ASTRONOMY AND ASTROPHYSICS↗