Search NASA⌕ Search

SEARCH · Search NASA

Results for “capacity value”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

High Power Density, Carbon Neutral Electrical Power Generation for Air Vehicles

The synergistic integration of a Solid Oxide Fuel Cell-Combustor (SOFC-C) with a turbogenerator (TG) will provide a very high fuel-to-electricity conversion efficiency while maintaining high power-to-weight ratio during high-altitude flight. The proposed SOFC-C-TG power generation technology exceeds the REEACH technical performance targets (TPT). This unique concept addresses many of the challenges faced in all electric propulsion-based aviation. The system has high part-load efficiency (more than 65% lower heating value (LHV)) during long cruise times, load following capability, high-power capacity at high altitudes adapting to low temperatures and pressures, rapid startup time of less than 30 minutes (proven with current SOFC technology), high power density (more than 3.2 kW/kg), efficient thermal management, and a foundation for a compact, efficient electrical storage and power generation system (ESPG). The SOFC-C concept achieves the technology targets by reducing the complexity of traditional fuel cell-gas turbine hybrid systems (FC-GT). The SOFC-C does not require heat exchangers and dramatically reduces the balance of plant increasing power density and performance in efficiency. The reduction in mass through elimination of heat exchangers, external reformer, and other components dramatically decreases the overall thermal dampening of the system which enables rapid startup and load following capability. Direct control of the cathode inlet temperature of the SOFC-C enables rapid warm-up of the SOFC tubes with the ability to reach operating temperature and full power in less than 30 minutes.

03 NATURAL GAS↗

Deployment Pathways for Long Duration Energy Storage

We apply a least-cost generation expansion model of the continental United States to assess how optimal investments in long-duration energy storage (LDES) technologies are impacted by changes in system generation portfolios and technology costs, assessing 369 capacity expansion scenarios in total. The expansion model considers 8,760 h of chronological operations for the entire target year, 2040. We find that low-cost LDES technologies can reduce generation investments and system costs. Specifically, once the costs for 24- and 100-h storage reach $38/kWh and $14/kWh, respectively, substantial deployments are observed. The distribution of storage investments across durations is strongly influenced by the system generation portfolio. We also demonstrate that a high-fidelity temporal representation is required to capture the value of LDES in generation expansion. Finally, we conduct a regression analysis of our capacity expansion results and find that LDES deployments are positively correlated with the combined wind and solar capacity share and negatively correlated with peaking and baseload shares.

Levin, Todd↗

Endogenizing Probabilistic Resource Adequacy Risks in Deterministic Capacity Expansion Models

In this work, we demonstrate how power system capacity expansion models can understate the stochastic effects of thermal outages when considering resource availabilities on an hourly expected value basis, yielding system designs with multiple orders of magnitude more shortfall risk than stated adequacy targets. We develop a novel approximation approach to efficiently endogenize awareness of this risk in a deterministic, linear capacity expansion framework. We compare this approach to exogenous tuning of an energy reserve margin, the leading alternative method to compensate for unmodeled probabilistic shortfall risk. Empirical results from a test system show that the new endogenous method cost-effectively meets all regional reliability targets with a single optimization solve, and produces a near-identical system design as the incumbent method without the need for repeated re-optimizations to find an appropriate reserve level. The endogenous method may also use iterative re-optimizations to further improve solution quality, although these incremental benefits were modest in the system studied.

capacity expansion modeling↗

A Technical and Economic Assessment of LWR Flexible Operation for Generation and Demand Balancing to Optimize Plant Revenue

With increased penetration of subsidized variable renewable energy (VRE) resources and competition from low natural gas prices, existing light water reactor (LWR) nuclear power plants (NPPs) are struggling to remain economically competitive. This work examines the potential economic competitiveness of various thermal energy storage (TES) technologies when coupled directly or indirectly with a NPP. To highlight their relative economic competitiveness, we contrast several energy storage solutions in stochastic dispatch optimization. We leverage data from recent work analyzing a range of TES technologies with varying capital costs, performance, and technology readiness level (TRL) to establish our case. We explore inserting these technologies into an electricity market with existing nuclear generation and large projected variable renewable energy (VRE) penetration. Although these technologies' projected capital costs may make them unlikely candidates in their current state, this analysis demonstrates a high-fidelity techno-economic analysis of energy storage. Furthermore, as the projected cost of energy storage technologies evolves, this analysis sets a precedent for similar future investigations. One region with projected trends that may be unfavorable for existing nuclear capacity is the New York Independent System Operator (NYISO) market. New York state’s baseload generation has been historically provided by fossil-fired and nuclear assets. However, amid economic pressures from subsidized VREs and low natural gas prices, the state has recently deactivated Indian Point nuclear power plant units 2 and 3. Furthermore, the state plans to meet its zero-emission generation target by 2040 by replacing fossil-fired capacity with significant investments in VRE resources like wind and solar photovoltaic (PV) and battery storage. Increased intermittent resource penetration lowers the baseload power requirement, adding further economic pressure to the state’s three remaining NPPs still in operation. With three NPPs still in operation in New York, this work analyzes potential economic benefits to NPPs on the New York grid when directly or indirectly coupled with various TES technologies. This work requires two modeling steps to analyze the potential economic benefits of various system configurations of the TES directly or indirectly coupled with nuclear. First, this analysis leverages capacity expansion modeling by experts at the Electric Power Research Institute (EPRI). Using their deterministic capacity expansion model, U.S. Regional Economy, Greenhouse Gas, and Energy (US-REGEN), EPRI analysts evaluated the capacity and generation evolution of the New York state energy market under four projection scenarios. These four projection scenarios were developed to represent the potential evolution of the capacity and generation in NYISO from 2015 to 2050 under various economic, technology, and policy constraints. The results from these capacity expansion models are then used as boundary conditions in the second modeling step. The second modeling step uses the Holistic Energy Resource Optimization Network (HERON) for a set of stochastic techno-economic analyses (STEAs) to investigate the potential increase in the economic viability of various configurations of the TES. With no current capacity expansion capabilities, HERON takes the data generated from US-REGEN for 2050 to generate synthetic load, solar, and wind data. Then HERON economically optimizes the capacity and dispatch of the various TES configurations. The potential economic benefit is the differential net present value (NPV) of the TES configurations from the no-TES baseline. As a stochastic techno-economic analysis package, HERON introduces uncertainty into the economic metrics, while US-REGEN trades resolution for reduced computational complexity. Using HERON also allows the modeling of direct thermal coupling, a feature not common in capacity and dispatch models. As expected, with high capital costs, the costs of introducing energy storage for all the technologies considered outweighed the potential economic benefit of this strategy for flexible plant operation. The benefit of this analysis is primarily in demonstrating a workflow that examines innovative solutions to increase NPP revenue via TES coupling. HERON’s stochastic capacity and dispatch optimization process used in this work has proven an effective tool in observing and evaluating the impact of introducing storage technologies in a grid energy system.

25 ENERGY STORAGE↗

1.2.2.405 HydroWIRES Topic D1: Capacity Expansion Model (CEM) Enhancements

Long-term grid planning tools have difficulty representing detailed hydropower operating characteristics, which depend not only on technological specifications but also on water management practices and regulations. As a result, the value of hydropower is incompletely characterized, and the potential role of hydropower in the performance and resiliency of the future electric grid is not fully understood. This work will fill that gap by developing new ways to represent hydropower resource, technology, and operational characteristics in electric sector capacity expansion models and implementing them in the open-source version of the National Renewable Energy Laboratory's Regional Energy Deployment System (ReEDS) model. ReEDS is a well-established national scale grid planning tool used since 2003 by the U.S. Department of Energy and others to explore the evolution of the U.S. electric sector. Improvements will include a comprehensive national resource assessment for pumped storage hydropower and methods for modeling multiple hydropower technology categories characterized by technical, regulatory, and economic characteristics. The project will provide guiding principles and strategies for improving hydropower modeling in capacity expansion models and deliver a first-of-its kind versatile PSH dataset. All data, code, and methods will be publicly available, allowing the industry to better identify the value of hydropower in the future electricity system and make more informed planning decisions.

capacity expansion↗

Multi-Stage Modeling With Recourse Decisions for Solving Stochastic Complementarity Problems With an Application in Energy

This paper presents a multi-stage model with recourse decisions for solving complementarity problems in a competitive electricity market under uncertainty, while also considering renewable energy technologies and battery storage utilization. The model is based on a Nash-Cournot formulation of imperfect competition among power producers. We analyze the value of variable renewable energy (VRE) and battery storage under different uncertainties, such as demand level and VRE availability. To illustrate the proposed model, we apply it to three- bus five-player model and analyze different cases varying costs, including a user-optimal perspective (with market power) and a system-optimal perspective (with central planning). We also consider the potential for congestion in the system by restricting the transmission capacity between a single interface that connects two buses. Our findings show that increasing the battery storage capacity results in a decrease in the need for perfect information about future uncertainties. Additionally, as the model allows for more uncertainty, it becomes more apparent that the stochastic mixed complementarity problem (MCP) has an advantage over a deterministic equivalent. We propose the use of the Value of the Stochastic Equilibrium Solution (VSES) as a quality metric to compare the stochastic MCP with its deterministic equivalent. Overall, expanding battery storage capacity can lower the maximum, mean, and variance values of delivered prices, but there are diminishing returns to this approach.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Coprecipitation of Fe/Cr Hydroxides at Organic–Water Interfaces: Functional Group Richness and (De)protonation Control Amounts and Compositions of Coprecipitates

Iron/chromium hydroxide coprecipitation controls the fate and transport of toxic chromium (Cr) in many natural and engineered systems. Organic coatings on soil and engineered surfaces are ubiquitous; however, mechanistic controls of these organic coatings over Fe/Cr hydroxide coprecipitation are poorly understood. Here, Fe/Cr hydroxide coprecipitation was conducted on model organic coatings of humic acid (HA), sodium alginate (SA), and bovine serum albumin (BSA). The organics bonded with SiO 2 through ligand exchange with carboxyl (-COOH), and the adsorbed amounts and pK(a) values of -COOH controlled surface charges of coatings. The adsorbed organic films also had different complexation capacities with Fe/Cr ions and Fe/Cr hydroxide particles, resulting in significant differences in both the amount (on HA > SA(-COOH) >> BSA(-NH 2 )) and composition (Cr/Fe molar ratio: on BSA(-NH2) >> HA > SA(-COOH)) of heterogeneous precipitates. Negatively charged -COOH attracted more Fe ions and oligomers of hydrolyzed Fe/Cr species and subsequently promoted heterogeneous precipitation of Fe/Cr hydroxide nanoparticles. Organic coatings containing -NH 2 were positively charged at acidic pH because of the high pK(a) value of the functional group, limiting cation adsorption and formation of coprecipitates. Meanwhile, the higher local pH near the -NH 2 coatings promoted the formation of Cr(OH) 3 . Finally, this study advances fundamental understanding of heterogeneous Fe/Cr hydroxide coprecipitation on organics, which is essential for successful Cr remediation and removal in both natural and engineered settings, as well as the synthesis of Cr-doped iron (oxy)hydroxides for material applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluating the Grid Impact of Oregon Offshore Wind [Slides]

This analysis used high-resolution offshore wind data and a detailed production cost model (PCM) of the Western Interconnection to explore the value and operational impact of integrating offshore wind along Oregon's coastline. Leveraging local technical stakeholder expertise and input, we determined a set of scenarios to explore. These scenarios vary both offshore wind capacities and the Western Interconnection generation and transmission infrastructure. From the scenario modeling and analysis, we identified the following key findings. In addition, we simulated a subset of the scenarios for a range of historical weather years (2007-2013), to understand the robustness of our findings to different weather conditions. Trans-coastal transmission constraints and congestion are the key drivers to the curtailment of Oregon offshore wind. Once power can be delivered into the Willamette Valley, there are few system constraints that lead to a significant curtailment of offshore wind off the coast of Oregon. Approximately 2.6 GW of installed offshore wind capacity can be integrated into Oregon's power system without major upgrades to trans-coastal transmission while avoiding significant curtailment. The system value provided by offshore wind ranges between $\$65$ /MWh and $\$85$ /MWh across the various scenarios considered. Offshore wind heavily influences the flow of the cross Cascade transmission. Across all scenarios, we found a robust relationship of approximately 500-550 MW decrease in the hourly flow of the cross Cascade transmission for every 1,000 MW of hourly offshore wind generation. However, we also found there was not a strong relationship between the highest cross-Cascade transmission flow hours and high offshore wind generation, limiting the extent to which offshore wind can be considered a non-wires alternative to cross cascade transmission. Depending on the meteorological year, 880-1,580 MW and 1,650-3,100 MW can be counted on to serve coastal loads with 2.6 GW and 5 GW of offshore wind capacity, respectively. Offshore wind allows for more optimal daily and hourly scheduling of hydropower, while still complying with various technical and regulatory constraints on the water resource. Oregon offshore wind has the potential to contribute to the evening net load peak in California (i.e., mitigate duck curve challenges), however transmission congestion between California and Oregon limits this contribution. Co-located storage at the point of interconnection for offshore wind reduces curtailment when trans-coastal transmission is not upgraded, providing a non-wires alternative to increase offshore wind capacity beyond 2.6 GW.

17 WIND ENERGY↗

Bill Savings vs. Backup Power: Evaluating operational tradeoffs for home solar+storage systems [Slides]

This study explores tradeoffs between the use of home solar+storage systems for backup power versus day-to-day utility bill savings. The study focuses specifically on the “reserve setting” available with most home battery storage systems, which allow the customer to maintain some minimum level of storage in reserve in case of an unforeseen power interruption. The more capacity that is held in reserve, the greater the customer’s ability to ride-through possible power interruptions, but less capacity is then available to manage utility bills on a day-to-day basis. This study evaluates this operational tradeoff across a diverse set of locations and residential electricity tariff structures, relying on Berkeley Lab’s PRESTO model to stochastically simulate power interruption events, and exploring a range of sensitivities, including variations in customer value of lost load (VoLL), interruption frequency, and other key drivers. The results show that, in most circumstances, the opportunity cost of holding storage capacity in reserve, in terms of foregone bill saving, tends to outweigh any gains in reliability value associated with mitigated power interruptions. This finding is robust across tariff structures and across most of the sensitivities considered, including those related to rate level, customer load level, and storage sizing. There are a limited set of circumstances where raising the reserve setting improves the overall customer value (comprised of bill savings plus reliability value). Specifically, that exception occurs when all of the following conditions apply: (a) the customer resides in a location with exceptionally poor reliability, (b) the customer has exceptionally high VoLL; (c) the customer is on a net billing rate or on a TOU rate that allows grid discharging but not grid charging; and (d), depending on the location, the price arbitrage differential on that rate is relatively small. In all other circumstances analyzed, total customer value declines with reserve level.

14 SOLAR ENERGY↗

Renewable-Storage Hybrids in a Decarbonized Electricity Supply

We explore the potential impacts of growing industry interest in hybrid systems comprising PV and battery technologies on the results and findings of the Solar Futures Study (2021). Through comparison of Solar Futures Study scenarios with and without PV-battery hybrid configurations enabled (in the same grid planning model), we find that the highest net-value hybrid configuration depends strongly on power sector carbon policy, which increases the value of more forward-looking designs. While the availability of PV-battery hybrid configurations primarily displaces standalone PV and battery capacity, we find that it (a) increases solar's share of total capacity and generation and (b) reduces required transmission expansion and associated costs under scenarios that combine aggressive cost reductions and power sector decarbonization policy. Results will also be presented for the complementarity and economic value of wind-PV hybrids with varying amounts of energy storage.

complementarity↗

Exploring the dependence of gas cooling and heating functions on the incident radiation field with machine learning

ABSTRACT Gas cooling and heating functions play a crucial role in galaxy formation. But, it is computationally expensive to exactly compute these functions in the presence of an incident radiation field. These computations can be greatly sped up by using interpolation tables of pre-computed values, at the expense of making significant and sometimes even unjustified approximations. Here, we explore the capacity of machine learning to approximate cooling and heating functions with a generalized radiation field. Specifically, we use the machine learning algorithm XGBoost to predict cooling and heating functions calculated with the photoionization code cloudy at fixed metallicity, using different combinations of photoionization rates as features. We perform a constrained quadratic fit in metallicity to enable a fair comparison with traditional interpolation methods at arbitrary metallicity. We consider the relative importance of various photoionization rates through both a principal component analysis (PCA) and calculation of SHapley Additive exPlanation (shap) values for our XGBoost models. We use feature importance information to select different subsets of rates to use in model training. Our XGBoost models outperform a traditional interpolation approach at each fixed metallicity, regardless of feature selection. At arbitrary metallicity, we are able to reduce the frequency of the largest cooling and heating function errors compared to an interpolation table. We find that the primary bottleneck to increasing accuracy lies in accurately capturing the metallicity dependence. This study demonstrates the potential of machine learning methods such as XGBoost to capture the non-linear behaviour of cooling and heating functions.

79 ASTRONOMY AND ASTROPHYSICS↗

Magnetic ground state of La 2 LiMoO 6 : A comparison with other Mo 5+ ( S=1/2 ) double perovskites

La 2 LiMoO 6 is a double perovskite (DP) with P2 1 /n symmetry based on the Mo5+ ion, 4d1, t2g1, S=1/2. It is isostructural with Sr 2 YMoO 6 , the magnetic ground state of which is apparently a very unusual collective spin singlet or valence-bond glass state as is the case for cubic (Fm-3m) Ba 2 YMoO 6 . Initial studies of La 2 LiMoO 6 suggested a different ground state from the other DPs but no clear conclusions could be drawn. A more detailed study is presented here including magnetic susceptibility, heat capacity, and elastic neutron-scattering results. This DP is now well characterized as an antiferromagnet, T N =18K, via observation of magnetic Bragg peaks in neutron scattering and an anomaly in the magnetic heat capacity. The ordering wave vector is k=( 1/21/2 0), consistent with a type I face-centered-cubic magnetic structure, and the ordered moment on Mo 5+ is 0.32(11)μ B , much reduced from the spin-only value of 1μ B . The index, f=|v c |/T N ~3, indicates a low level of frustration. The heat-capacity data above T N can be interpreted in terms of a one-dimensional spin-correlation model, as can the low-temperature data which follow a T 1 power law. This is consistent with an earlier suggestion. The difference with isostructural Sr 2 YMoO 6 is attributed to differences in the local distortion of the Mo–O octahedron and the resulting orbital ordering.

36 MATERIALS SCIENCE↗

A High‐Rate Li–CO 2 Battery Enabled by 2D Medium‐Entropy Catalyst

Abstract Lithium‐air batteries based on CO 2 reactant (Li–CO 2 ) have recently been of interest because it has been found that reversible Li/CO 2 electrochemistry is feasible. In this study, a new medium‐entropy cathode catalyst, (NbTa) 0.5 BiS 3 , that enables the reversible electrochemistry to operate at high rates is presented. This medium entropy cathode catalyst is combined with an ionic liquid‐based electrolyte blend to give a Li–CO 2 battery that operates at high current density of 5000 mA g −1 and capacity of 5000 mAh g −1 for up to 125 cycles, far exceeding reported values in the literature for this type of battery. The higher rate performance is believed to be due to the greater stability of the multi‐element (NbTa) 0.5 BiS 3 catalyst because of its higher entropy compared to previously used catalysts with a smaller number of elements with lower entropies. Evidence for this comes from computational studies giving very low surface energies (high surface stability) for (NbTa) 0.5 BiS 3 and transmission electron microscopystudies showing the structure being retained after cycling. In addition, the calculations indicate that Nb‐terminated surface promotes Li–CO 2 electrochemistry resulting in Li 2 CO 3 and carbon formation, consistent with the products found in the cell. These results open new direction to design and develop high‐performance Li–CO 2 batteries.

25 ENERGY STORAGE↗

Urban cells: Extending the energy hub concept to facilitate sector and spatial coupling

The rapid growth of urban areas and concerns over climate change make it vital to improve the energy sustainability of cities. Understanding the complex interactions within different sectors (sectoral) and localities (spatial) of cities plays a crucial role in improving efficiency and sustainability, which is extremely challenging due to the complex urban morphology. State-of-the-art energy concepts do not facilitate a detailed consideration of both sectoral and spatial coupling that energy infrastructure maintains at the urban scale. This has become a significant challenge when designing interconnected urban energy infrastructure. The Urban Cell concept is introduced to address this bottleneck. A novel computational model using a modular approach is introduced to create an interconnected urban infrastructure, including the energy, building, and transportation sectors. Optimal sizing of the distributed energy system (including renewables, energy storage, and dispatchable sources) and optimal urban morphology is determined within a modular unit. A game-theoretic approach is used to model the interactions between urban cells (modular units). The study revealed that the urban cell concept can reduce the net present value of the interconnected energy infrastructure by 37% while increasing the installed renewable energy capacity by 25%. This demonstrates the benefit potential of urban cells and the importance of considering interactions between different sectors and different parts within a city. The Urban Cell concept can be used to present the complex interactions maintained within a city.

Perera, ATD↗

Evaluation of the energy balance of chemical looping combustion of solid fuels using CuO-based oxygen carriers

Chemical looping combustion (CLC) can inherently capture the CO2 generated during thermal energy production. When using CuO-based oxygen carriers, the reactions in both the fuel reactor (FR) and air reactor (AR) are exothermic, facilitating autothermal operation. To prevent the oxygen carrier from becoming agglomerated while ensuring a sufficient oxygen release rate, it is necessary to predict the FR temperature and remove an appropriate amount of heat from the AR when burning high-rank fuels. Here in this work, the energy balance of a CuO-based CLC system firing various solid fuels (biomass, coal, and petroleum coke) was investigated by establishing a thermodynamic model using FactSage. The energy distribution characteristics of the FR were quantified based on a virtual five-step thermodynamic sequence. The effects of fuel properties, oxygen carrier properties, and operating conditions on the energy balance were evaluated systematically. The results indicate that the temperature difference between the FR and AR is not very sensitive to the heating value of the fuel, while the CuO loading of the oxygen carrier, the heat capacity of the support material, and the flow rate of the fluidizing gas have significant impact. The insights obtained in this work will help improve the design and heat management of CLC.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Field tunable magnetic transitions of CsCo 2 (MoO 4 ) 2 (OH): a triangular chain structure with a frustrated geometry

The sawtooth chain compound CsCo 2 (MoO 4 ) 2 (OH) is a complex magnetic system and here, we present a comprehensive series of magnetic and neutron scattering measurements to determine its magnetic phase diagram. The magnetic properties of CsCo 2 (MoO 4 ) 2 (OH) exhibit a strong coupling to the crystal lattice and its magnetic ground state can be easily manipulated by applied magnetic fields. There are two unique Co 2+ ions, base and vertex, with J bb and J bv magnetic exchange. The magnetism is highly anisotropic with the b-axis (chain) along the easy axis and the material orders antiferromagnetically at T N = 5 K. There are two successive metamagnetic transitions, the first at H c 1 = 0.2 kOe into a ferrimagnetic structure, and the other at H c 2 = 20 kOe to a ferromagnetic phase. Heat capacity measurements in various fields support the metamagnetic phase transformations, and the magnetic entropy value is intermediate between S = 3/2 and 1/2 states. The zero field antiferromagnetic phase contains vertex magnetic vectors (Co(1)) aligned parallel to the b-axis, while the base vectors (Co(2)) are canted by 34° and aligned in an opposite direction to the vertex vectors. The spins in parallel adjacent chains align in opposite directions, creating an overall antiferromagnetic structure. Further, at a 3 kOe applied magnetic field, adjacent chains flip by 180° to generate a ferrimagnetic phase. An increase in field gradually induces the Co(1) moment to rotate along the b-axis and align in the same direction with Co(2) generating a ferromagnetic structure. The antiferromagnetic exchange parameters are calculated to be J bb = 0.028 meV and J bv = 0.13 meV, while the interchain exchange parameter is considerably weaker at J ch = (0.0047/N ch ) meV. Our results demonstrate that the CsCo 2 (MoO 4 ) 2 (OH) is a promising candidate to study new physics associated with sawtooth chain magnetism and it encourages further theoretical studies as well as the synthesis of other sawtooth chain structures with different magnetic ions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Physical properties investigation of tetragonal Ba T 2 P 2 (T = Ru, Pd)

The structural, thermal, electrical transport, and magnetic properties of ternary compounds BaT 2 P 2 (T = Ru, Pd) are reported together with electronic structure calculations. Our results show that BaRu 2 P 2 crystallises in the layered tetragonal ThCr 2 Si 2 -type structure (space group I4/mmm) whereas BaPd 2 P 2 adopts the primitive tetragonal CeMg 2 Si 2 -type structure (space group P4/mmm). The combined experimental results and electronic structure calculations suggest metallic and diamagnetic ground states for both materials. Electrical transport measurements further indicate non-Fermi liquid behaviour at low temperatures. Notably, BaRu 2 P 2 exhibits an anomalous feature in the magnetic susceptibility at T ~ 260 K, similar to that observed in BaRu 2 As 2 . A comparison between the bare density of states obtained from electronic structure calculations and the experimentally estimated values suggests the presence of strong correlation effects in the material. Furthermore, the heat capacity of BaPd 2 P 2 , calculated using the full phonon dispersion relation, is in good agreement with the experimental data, particularly at low temperatures, highlighting the significant contribution of optical phonon branches to C P in this temperature range.

flat bands↗

Agent-Based Simulation of Price-Demand Dynamics in Multi-Service Charging Station

As the adoption of electric vehicles and hydrogen fuel-cell vehicles grows, understanding how dynamic pricing strategies influence charging and refueling behaviors becomes crucial for optimizing local energy markets. This paper proposes a simulation-based analysis of a hydrogen-electricity integrated charging station that serves both types of vehicles. A multi-agent simulation framework is developed to model the interactions between vehicles and the station, incorporating price- and delay-sensitive behaviors in decision-making. The station can dynamically adjust energy prices, while vehicles optimize their charging or refueling choices based on their utility values. A series of sensitivity analyses are conducted to evaluate how electricity pricing, infrastructure capacity, and waiting behavior impact station performance. Results highlight that moderate electricity prices maximize user participation without sacrificing profit, infrastructure should be right-sized to demand to avoid over- or underutilization, and delay-toleration also affects service outcomes, which may reach the maximum service coverage at the threshold of 45 minutes.

Wang, Xudong [University of Tennessee, Knoxville (↗