Search NASA⌕ Search

SEARCH · Search NASA

Results for “chirping”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Broadband 920-nm mirror thin film damage competition

The 2023 Laser Damage conference thin-film damage competition was devoted to a survey on the state-of-the-art broadband near-IR multilayer dielectric (MLD) mirrors designed for ultra-short pulsed laser applications. The requirements for the coatings were a minimum reflection of 99.5% at 45-deg incidence angle for S-polarization from 830 nm to 1010 nm and group delay dispersion (GDD) < ± 50fs 2 . The participants were allowed to select the coating materials, coating design, and coating deposition method. Samples were damage tested at a single testing facility to enable direct comparison among the participants using a 25 ± 5 fs optical parametric chirped-pulse amplification (OPCPA) laser system operating at 5 Hz. The testing results from this set of 37 samples showed that dense coatings by ion-beam sputtering (IBS), magnetron sputtering (MS), and electron-beam ion assisted deposition (e-beam IAD) exhibited highest damage initiation onset (laser-induced damage threshold or LIDT) while e-beam coatings were low performers. In addition, multilayer coatings using tantala and/or hafnia as high index materials were top performers. Furthermore, this competition included for the first time the measurement of the damage growth onset (laser-induced damage growth threshold or LDGT). This latter performance metric plays an important role in establishing the safe operational conditions for larger aperture ultrashort pulsed lasers. Information pertaining to the morphology of the damage sites and their evolution under subsequent exposure to different laser fluences leading to damage growth is presented. Finally, not all coating samples in the survey met the GDD requirements stated above and associated measurements are discussed in the context of the present and past thin-film damage competitions focused on similar broadband near-IR MLD coatings.

23 broadband high reflectors↗

A highly efficient, 10-J output signal amplifier for ultra-intense all-OPCPA systems

Optical parametric chirped-pulse amplification (OPCPA) using high-energy Nd:glass lasers has the potential to produce ultra-intense pulses (>10 23 W/cm 2 ). We report on the performance of the final high-efficiency amplifier in an OPCPA system based on large-aperture (63 x 63-mm 2 ) partially deuterated potassium dihydrogen phosphate (DKDP) crystals. Here, the seed beam (170 nm, 240 mJ) was provided by the preceding OPCPA stages. The maximum pump-to-signal conversion efficiency of 37% was achieved with a 52-mm-long DKDP crystal and 40-J pump energy at 527 nm due to the flattop super-Gaussian pump beam profile and flat-in-time pulse shape. The 11.8-J output signal was compressed to 19 fs.

42 ENGINEERING↗

Rotational Millimeter-Wave Shoe Scanner Using the Discrete Fourier Transform for Backprojection-Based Image Reconstruction

An active 3D microwave / millimeter-wave shoe scanner was previously developed at the Pacific Northwest National Laboratory (PNNL) using two linear arrays scanned over a rectilinear aperture. The radar system chirps a frequency sweep from 10-40 GHz. These frequencies allow imaging through optically opaque material such as leather, rubber, plastics, and other dielectrics. The system was designed to detect concealed items in the soles of shoes while allowing people to leave their shoes on through a security checkpoint. To shrink the footprint of the system, a new iteration of the design has been developed that scans the two linear arrays over a circular aperture. This new footprint opens the possibility of it being installed in the floor of a cylindrical millimeter-wave body scanner. The backprojection-based multilayer dielectric image reconstruction developed at PNNL can easily handle arbitrary spatial sampling, accommodating the new rotational shoe scanner design. Commonly, the fast Fourier transform (FFT) is used to efficiently compute the range response from the data collected by the system as a preprocessing step to the backprojection algorithm. It was found that converting to range using the discrete Fourier transform (DFT) directly has some advantages over the FFT. For example, nonlinear and non-uniform frequency sweeps can easily be compensated for during the computation of the DFT and only the range bins of interest need to be computed and their spacing can be chosen arbitrarily. Because the range conversion step of the image reconstruction is the fastest part of the process there is very little speed penalty for using the DFT over the FFT and it can even increase the speed of image reconstruction when the ranges of interest are fewer than the total span that is calculated in the FFT.

Millimeter-wave imaging, microwave imaging, shoe s↗

Laser system design and critical technologies for the NSF OPAL project

The three-year NSF OPAL project is completing the preliminary design of a 2 x 25-PW all-optical parametric chirped-pulse amplification (OPCPA) system capable of delivering 500-J, 20-fs pulses. The design includes two Alpha beamlines that can be co-timed and pointed into two experimental areas for high-intensity research in several configurations. Additionally, a more flexible 2-PW Beta beam can be used in place of one Alpha beam to allow a wider range of focusing geometries and synchronized electron-beam generation for diverse experimental applications. Here, building on the development of the mid-scale MTW-OPAL prototype system, the NSF OPAL project also focuses on advancing essential technologies, such as large-grating fabrication techniques and actively-cooled disk amplifiers.

42 ENGINEERING↗

Improving inverse Compton sources by avoiding non-linearities

We present a new, more nuanced understanding of non-linear effects in inverse Compton sources. Deleterious non-linear effects can arise even at low laser intensities, a regime previously viewed as linear. After laying out a survey of non-linear phenomena which degrade the effectiveness of inverse Compton sources, we discuss two powerful techniques designed to avoid these non-linearities. Starting with the known technique of non-linear longitudinal chirping of the laser pulse in the high laser field regime, we show that the simple stretching of the laser pulse, while keeping the energy constant, can significantly increase the spectral density of the scattered radiation in many operating regimes. Our numerical simulations show that combining these two techniques avoids detrimental non-linearities and improves the performance of inverse Compton sources over an order of magnitude.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Advanced laser development and plasma-physics studies on the multiterawatt laser

The Multi-Terawatt (MTW) laser, built initially as the prototype front-end for a petawatt laser system, is a 1053-nm hybrid system with gain from optical parametric chirped-pulse amplification (OPCPA) and Nd:glass. Here, compressors and target chambers were added, making MTW a complete laser facility (output energy up to 120 J, pulse duration from 20 fs to 2.8 ns) for studying high-energy-density physics and developing short-pulse laser technologies and target diagnostics. Further extensions of the laser support ultrahigh-intensity laser development of an all-OPCPA system and a Raman plasma amplifier. A short summary of the variety of scientific experiments conducted on MTW is also presented.

47 OTHER INSTRUMENTATION↗

Impact of the optical parametric amplification phase on laser pulse compression

Optical parametric chirped-pulse amplification (OPCPA) is an effective way to generate ultrashort pulses that has been used extensively for a variety of applications requiring high peak intensities. Precise control and measurement of a system’s spectral and spatial phases are required for Fourier transform–limited pulse compression and diffraction-limited focusing. Phase accumulated during optical parametric amplification (OPA) can degrade the compressibility and focusability of the pulse, reducing peak intensity. We used analytic and numerical analysis of OPA to study the influence of crystal parameters, wavefront of the pump and signal, and their relative optical alignment on the accumulated phase. Here, we show that the accumulated signal phase is largely independent of amplifier saturation and, with significant local wavefront gradients in the signal or pump beam, the quality of the compressed pulses can be degraded. We use first-order expressions for the pump- and signal-angle sensitivity to evaluate an OPCPA system consisting of a highly deuterated potassium dihydrogen phosphate (DKDP) amplifier designed to support bandwidth for 15 fs pulses centered at 920 nm.

47 OTHER INSTRUMENTATION↗

Temporal contrast degradation from mid-spatial-frequency surface error on stretcher mirrors

Temporal contrast degradation due to mid-spatial-frequency error in chirped-pulse amplification stretcher optics is studied. Third-order cross-correlation measurements reveal a temporal peak that appears when using two different mirrors processed by magnetorheological finishing, despite an improvement in rms roughness compared to a third unprocessed mirror. Simulations based on measured power spectral density show how the actual impact on contrast is different from measurements using a typical bandwidth-limited third-order cross correlator. Furthermore, strategies are proposed to avoid this type of contrast degradation while exploiting computer numerically controlled polishing techniques for enhancement of surface figure and roughness.

47 OTHER INSTRUMENTATION↗

Intense infrared lasers for strong-field science

The advent of chirped-pulse amplification in the 1980s and femtosecond Ti:sapphire lasers in the 1990s enabled transformative advances in intense laser–matter interaction physics. Whereas most of experiments have been conducted in the limited near-infrared range of 0.8–1 μm, theories predict that many physical phenomena such as high harmonic generation in gases favor long laser wavelengths in terms of extending the high-energy cutoff. Significant progress has been made in developing few-cycle, carrier-envelope phase-stabilized, high-peak-power lasers in the 1.6–2 μm range that has laid the foundation for attosecond X ray sources in the water window. Even longer wavelength lasers are becoming available that are suitable to study light filamentation, high harmonic generation, and laser–plasma interaction in the relativistic regime. Long-wavelength lasers are suitable for sub-bandgap strong-field excitation of a wide range of solid materials, including semiconductors. In the strong-field limit, bulk crystals also produce high-order harmonics. In this review, we first introduce several important wavelength scaling laws in strong-field physics, then describe recent breakthroughs in short- (1.4–3 μm), mid- (3–8 μm), and long-wave (8–15 μm) infrared laser technology, and finally provide examples of strong-field applications of these novel lasers. Furthermore, some of the broadband ultrafast infrared lasers will have profound effects on medicine, environmental protection, and national defense, because their wavelengths cover the water absorption band, the molecular fingerprint region, as well as the atmospheric infrared transparent window.

43 PARTICLE ACCELERATORS↗

Scattering of an utlrashort laser pulse by a spherical air bubble

The scattering of an ultrashort laser pulse by an air bubble in water is investigated by means of the Lorenz-Mie theory and the Debye expansion. A 70 fs, 800 nm pulse is considered as a plane wave with a Gaussian temporal envelope. The transient response is treated with the theory derived from Gouesbet and Gréhan [ Part. Part. Syst. Charact. 17 , 213 –224 ( 2000 ) ], taking now into account chromatic dispersion and absorption of water. It is observed that contrary to the case of water droplet in air, the Debye modes p ≥ 1 start their transient scattering at the same time and the same angle (≈90 ° ) and for a large size parameter, they differentiate as time elapses. A parametric study on the size parameter and the spatial extension of the pulse is performed to identify regimes where the different Debye mode are distinguishable in time. Dependence on the scattering angle is also treated. Finally, by considering pulse chirp, it is shown that the laser/bubble distance has an influence on the separability of modes p = 0 and p = 1.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Encoding the complete electric field of an ultraviolet ultrashort laser pulse in a near-infrared nonlinear-optical signal

We introduce a variation on the cross-correlation frequency-resolved optical gating (XFROG) technique that uses a near-infrared (NIR) nonlinear-optical signal to characterize pulses in the ultraviolet (UV). Using a transient-grating XFROG beam geometry, we create a grating using two copies of the unknown UV pulse and diffract a NIR reference pulse from it. We show that, by varying the delay between the UV pulses creating the grating, the UV pulse intensity-and-phase information can be encoded into a NIR signal. We also implemented a modified generalized-projections phase-retrieval algorithm for retrieving the UV pulses from these spectrograms. We performed proof-of-principle measurements of chirped pulses and double pulses, all at 400 nm. This approach should be extendable deeper into the UV and potentially even into the extreme UV or x-ray range.

47 OTHER INSTRUMENTATION↗

Bandwidth extension and conversion efficiency improvements beyond phase matching limitations using cavity-enhanced OPCPA

The conversion efficiency and phase matching bandwidth of ultrafast optical parametric amplification (OPA) are constrained by the dispersion and nonlinear coefficient of the employed crystal as well as pulse shaping effects. In our work we show that an enhancement cavity resonant with the pump seeded at the full repetition rate of the pump laser can automatically reshape the small-signal gain in optical parametric chirped-pulse amplification (OPCPA) to achieve close-to-optimal operation. This new method termed cavity-enhanced OPCPA or C-OPCPA significantly increases both the gain bandwidth and the conversion efficiency, in addition to boosting gain for high-repetition-rate amplification. The goal in C-OPCPA is to arrive at a condition of impedance matching at all temporal coordinates, such that, in the absence of linear losses, all the incident pump power is dissipated in the nonlinear loss element, i.e., converted to signal and idler. The use of a low finesse enhancement cavity resonant with a low average power (<1W) and a high repetition rate (78MHz) pump source is shown to achieve more than 50% conversion efficiency into signal and idler from the coupled pump in an optical parametric process, whereas an equivalent amount of pump power in a single-pass configuration leads to negligible conversion. Additionally, the gain bandwidth is extended by a factor of 3-4 beyond the phase-matching limit. Our empirical observations are corroborated by a numerical analysis of depletion optimizing the single-pass case, which assesses the underlying impedance matching that is responsible for the observed performance improvements.

47 OTHER INSTRUMENTATION↗

Measuring an ultrashort, ultraviolet pulse in a slowly responding, absorbing medium

Frequency-resolved optical gating (FROG) is a common technique for measuring ultrashort laser pulses using an instantaneous, nonlinear-optical interaction as a fast time-gate to measure the pulse intensity and phase. But at high frequencies, materials are often absorbing and it is not always possible to find a medium with a fast nonlinear-optical response. Here we show that an ultrashort, ultraviolet (UV) pulse can be measured in a strongly absorbing medium, using the absorption as the nonlinear-optical time-gate. To do this, we build on our recent implementation of FROG, known as induced-grating cross-correlation FROG (IG XFROG), where an unknown, higher-frequency pulse creates a transient grating that is probed with a lower-frequency, more easily detectable reference pulse. We demonstrate this with an 800 nm reference pulse to characterize 400 nm or 267 nm pulses using ZnS as the nonlinear-optical medium, which is absorptive at and below 400 nm. By scanning the delay between the two UV pulses which create the transient grating, we show that the phase-sensitive instantaneous four-wave-mixing contribution to the nonlinear signal field can be detected and separated from the slower, incoherent part of the response. Measuring a spectrally-resolved cross-correlation in this way and then applying a simple model for the response of the medium, we show that a modified generalized projections (GP) phase-retrieval algorithm can be used to extract the pulse amplitude and phase. We test this approach by measuring chirped UV pulses centered at 400 nm and 267 nm. Since interband absorption (or even photoionization) is not strongly wavelength-dependent, we expect IG XFROG to be applicable deeper into the UV.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Milliradian precision ultrafast pulse control for spectral phase metrology

A pulse-shaper-based method for spectral phase measurement and compression with milliradian precision is proposed and tested experimentally. Measurements of chirp and third-order dispersion are performed and compared to theoretical predictions. The single-digit milliradian accuracy is benchmarked by a group velocity dispersion measurement of fused silica.

Stamm, Jacob↗

Post-compression of long-wave infrared 2 picosecond sub-terawatt pulses in bulk materials

We have experimentally demonstrated the post-compression of a long-wave infrared (9.2 μm) 150 GW peak power pulse from 2 ps to less than 500 fs using a sequence of two bulk materials with negative group velocity dispersion (GVD). The compression resulted in up to 1.6-fold increase of the peak power and up to 2.8-fold increase of the intensity in the center of a quasi-Gaussian beam. The partial decoupling of the self-phase modulation and chirp compensation stages by using two materials with significantly different ratios of nonlinear refractive index to GVD provides accurate optimization of the compression mechanism and promises a viable path to scaling peak powers to supra-terawatt levels. During the preparatory study, we measured, for the first time to our knowledge, the nonlinear refractive indices of NaCl, KCl, and BaF 2 for picosecond pulses in the long-wave infrared region.

43 PARTICLE ACCELERATORS↗

Survey of spatio-temporal couplings throughout high-power ultrashort lasers

The investigation of spatio-temporal couplings (STCs) of broadband light beams is becoming a key topic for the optimization as well as applications of ultrashort laser systems. This calls for accurate measurements of STCs. Yet, it is only recently that such complete spatio-temporal or spatio-spectral characterization has become possible, and it has so far mostly been implemented at the output of the laser systems, where experiments take place. In this survey, we present for the first time STC measurements at different stages of a collection of high-power ultrashort laser systems, all based on the chirped-pulse amplification (CPA) technique, but with very different output characteristics. This measurement campaign reveals spatio-temporal effects with various sources, and motivates the expanded use of STC characterization throughout CPA laser chains, as well as in a wider range of types of ultrafast laser systems. In this way knowledge will be gained not only about potential defects, but also about the fundamental dynamics and operating regimes of advanced ultrashort laser systems.

Jeandet, Antoine (ORCID:0000000345493067)↗

Effect of the pump beam profile and wavefront on the amplified signal wavefront in optical parametric amplifiers

We present a theoretical and experimental analysis of the signal phase introduced by the pump-beam wavefront and spatial profile during optical parametric amplification (OPA) process. The theory predicts the appearance of an additional wavefront in the amplified signal beam that is proportional to the spatial derivative of the pump-beam wavefront. The effect of the pump-beam profile on the signal-beam wavefront is also investigated. Our experiments tested these theoretical predictions by comparing the wavefront of the signal beam before and after amplification in a multi-joule broadband OPA. The measured signal wavefront was shown to have the expected dependence on the pump-beam profile and wavefront. These results can be considered when designing petawatt-scale ultrabroadband optical parametric chirped-pulse–amplification systems.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Numerical investigation of gas-filled multipass cells in the enhanced dispersion regime for clean spectral broadening and pulse compression

We show via numerical simulations that the regime of enhanced frequency chirp can be achieved in gas-filled multipass cells. Our results demonstrate that there exists a region of pulse and cell parameters for which a broad and flat spectrum with a smooth parabolic-like phase can be generated. This spectrum is compatible with clean ultrashort pulses, whose secondary structures are always below the 0.5% of its peak intensity such that the energy ratio (the energy contained within the main peak of the pulse) is above 98%. This regime makes multipass cell post-compression one of the most versatile schemes to sculpt a clean intense ultrashort optical pulse.

Segundo Staels, V. W. (ORCID:0000000200056157)↗