Search NASA⌕ Search

SEARCH · Search NASA

Results for “chirping”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

249 records · Page 14

AT2025ulz and S250818k: Zooming in with the Hubble Space Telescope

AT2025ulz is an optical/near-infrared transient discovered during follow-up of the candidate gravitational wave (GW) event S250818k. Its young age (≲1 day), rapid decline, and strong color evolution over the first 48 hr classify it as a potential kilonova candidate. In this work, we present the results of our observing campaign, carried out with the Gran Telescopio Canarias and the Hubble Space Telescope (HST). Although the early time evolution of AT2025ulz resembles some aspects of a kilonova, its rapid onset (∼3 hr after the GW trigger) and luminosity (a factor of ∼5 brighter than AT2017gfo in g band) are difficult to reproduce. Only a small subset of our kilonova models matches its multicolor light curve, and the inferred ejecta mass is uncomfortably large given the low chirp mass (≲0.87 M ⊙ ) of the GW candidate. HST observations place the transient within a nearby (z = 0.08489) spiral galaxy with ongoing star formation and measure a color (F336W − F160W ≈ 1.4 mag) that is too blue to match with a kilonova. Our data support the classification of AT2025ulz as a supernova, initially undergoing a shock-cooling phase and later entering its photospheric phase and spectroscopically identified via its broad absorption features.

79 ASTRONOMY AND ASTROPHYSICS↗

The real-time data processing and acquisition system for Project 8 Phase II

In Phase II of the Project 8 neutrino mass experiment, electrons from the decays of tritium or 83 m Kr are detected via their ≈ 26GHz cyclotron radiation while contained within a circular waveguide. The signal from a given electron is characterized as a brief chirp, lasting ≲ 10ms and changing in frequency by ≲ 1MHz/ms. To detect these signals, the Project 8 collaboration developed a Data Acquisition (DAQ) system tailored to the signal properties. The DAQ is responsible for simultaneously selecting up to three 100MHz-wide frequency windows to study, detect, and trigger on likely signals from different electron kinetic energies, and for writing the relevant data to disk. We describe the Phase II DAQ system in detail and address how the system was used for data-taking operations.

Ashtari Esfahani, A. [Washington U., Seattle; Shar↗

Alfven eigenmodes and fast ion transport in negative triangularity DIII-D plasmas

The first energetic particle experiments in negative triangularity tokamak plasmas have been carried out on DIII-D. Alfvén eigenmode (AE) activity and associated fast ion transport comparable to that in positive triangularity is observed during the current ramp portion of all plasmas with early beam heating indicating negative triangularity does not confer a special advantage with respect to AE induced transport. In these discharges, a range of mode activity driven by the sub-Alfvénic (Vbeam/VA < 0.5) 80 kV neutral beams is found including beta induced Alfvén acoustic eigenmodes, beta induced Alfvén eigenmodes, reversed shear Alfvén eigenmodes (RSAEs) and toroidicity induced Alfvén eigenmodes (TAEs). Mode intermittency and possibly chirping appears to be more common than comparable positive triangularity and/or oval discharges but overall, the unstable spectra and mode amplitudes observed on magnetics, CO2 interferometry, and electron cyclotron emission in a set of matched positive and negative triangularity cases at moderate beam power is similar. Large levels of Alfvén eigenmode induced fast ion transport are found in both positive and negative triangularity with up to 70% central fast ion pressure deficits relative to classical predictions early during the current ramp phase for discharges with 3 MW injected 80 kV neutral beam power. The deficit in both cases is reduced toward zero as the current penetrates and eventually reaches classical levels during current flattop with qmin ≈ 1. Fast ion transport in negative triangularity plasmas measured using a beam modulation technique show very similar levels to those measured in oval plasmas over the range of tested beam powers (Pbeam ≈ 2–7 MW). This similarity is found despite quite different unstable spectra in the highest beam power case where a mixture of coherent and quasi-coherent modes in the TAE frequency range are observed in negative triangularity and a spectrum of more typical narrowband TAEs and RSAEs is observed for the oval plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Synthetic-aperture radar (SAR) imaging with range-resolved reflection data

SAR imaging may be performed with range-resolved reflection data, where a spread-spectrum signal, such as a code division multiple access (CDMA) signal, is transmitted instead of a simple frequency chirp. The reflected spread-spectrum signal may be analyzed to gather range-resolved reflection data. Range-resolved reflection data may be gathered at each angular view. This data may be used to construct a more accurate approximation of the Fourier transform of the desired image than can be done by a conventional SAR approach. The image may be reconstructed from this Fourier transform using Fourier inversion techniques similar to those used in conventional SAR approaches. The range-resolved reflection scheme generally requires somewhat more processing to recover the image as compared with conventional SAR systems, but provides a significantly more stable image with less degradation from effects that plague conventional SAR systems. This can eliminate the need for phase coherency altogether and also eliminate “phase drift,” which leads to image distortion. This may be especially well suited for high resolution imaging of relatively large targets.

47 OTHER INSTRUMENTATION↗

Simultaneous real-time measurement of composition, flow, attenuation, density, and pipe-wallthickness in multiphase fluids

Apparatus (10) and methods for making simultaneous measurements of composition (water-cut), fluid flow, and sound attenuation in a multiphase fluid flowing (15) through a pipe (12) in real-time, using the same apparatus (10) are described. Additionally, the apparatus (10) provides real-time pipe wall thickness monitoring for observing pipe corrosion or internal deposition. Knowledge of wall thickness is necessary to correct for water-cut (oil-water composition) automatically by adjusting the liquid path length internal to the pipe (spool). The use of short duration frequency chirp excitation signals (24) enables the apparatus to provide information that can be used to extract multiple levels of information from the same measurement in multiphase fluids including the presence of a significant quantity of gas (˜60% gas volume fraction) in different flow regimes. Besides measuring steady flow, this device is useful for measurements during fast changing flows, such as for a rod-pumped well. Measurements up to about 1000 times a second can reliably be made.

Sinha, Dipen N.↗

Acoustic gas volume fraction measurement in a multiphase flowing liquid

Apparatus and methods for the measurement of gas volume fraction of produced oil are described. A first method measures the response of a pipe containing the produced oil excited by a source of vibration in the form of an acoustic frequency chirp containing a linearly varying range of frequencies in the tens of kilohertz range encompassing at least one resonant mode of the pipe. As the gas volume fraction increases, the location of the peak maximum of the measured frequency spectrum responsive to the excitation increases in frequency, and the height of the peak maximum increases, thereby permitting a linear calibration curve to be obtained. A second method measures the response of a pipe containing the produced oil to excitation by a continuous source of vibration having a chosen frequency above those which excite flexural vibrations in the pipe and simultaneously excite acoustic waves in the fluid contained in the pipe, known as the coincidence frequency. Gas present in the fluid will interrupt sound propagation or reverberation, thereby generating fluctuations in the amplitude of the measured vibrations of the pipe. The amplitude fluctuation level provides a measure of the gas volume present inside the pipe. A third method measures the response of a pipe containing the produced oil to excitation by a high-bandwidth, short pulse having a chosen center frequency above the coincidence frequency. Gas present in the fluid will interrupt pulse propagation, thereby generating fluctuations in the amplitude of the measured vibrations of the pipe.

Sinha, Dipen N.↗

Ultra-broadband voltage-controlled oscillator linearization for frequency modulated continuous wave MMW imaging systems

Millimeter-wave (MMW) imaging systems require high resolution and spurious free dynamic range (SFDR) to produce images with low artifacts. In these systems, lateral resolution is determined by the center frequency and the ratio of the aperture size to the distance to the target. The downrange resolution is determined by the system bandwidth; for very fine downrange resolution of a target, or material layers/discontinuities, the bandwidth must be very broad. Additionally, the response over the bandwidth must be measured very rapidly to support high speed acquisition over large apertures. A voltage-controlled oscillator (VCO) is a standard means of generating the ultra-broadband frequency chirp. This paper investigates the use of a broadband VCO for use in MMW imaging systems, a linear-phase calibration technique, and digital-to-analog converter (DAC) parameter considerations for controlling the VCO.

FMCW, homodyne, VCO, DAC, difference frequency, SF↗

Optimizing qubit control pulses for state preparation

In the burgeoning field of quantum computing, the precise design and optimization of quantum pulses are essential for enhancing qubit operation fidelity. This study focuses on refining the pulse engineering techniques for superconducting qubits, employing a detailed analysis of square and Gaussian pulse envelopes under various approximation schemes. We evaluated the effects of coherent errors induced by naive pulse designs. Furthermore, we identified the sources of these errors in the Hamiltonian model’s approximation level. We mitigated these errors through adjustments to the external driving frequency and pulse durations, thus implementing a pulse scheme with stroboscopic error reduction. Our results demonstrate that these refined pulse strategies improve performance and reduce coherent errors. Moreover, the techniques developed herein are applicable across different quantum architectures, such as ion-trap, atomic, and photonic systems.

Chirp modulation↗

Substitution Reactions in the Pyrolysis of Acetone Revealed through a Modeling, Experiment, Theory Paradigm

The development of high-fidelity mechanisms for chemically reactive systems is a challenging process that requires the compilation of rate descriptions for a large and somewhat ill-defined set of reactions. The present unified combination of modeling, experiment, and theory provides a paradigm for improving such mechanism development efforts. Here we combine broadband rotational spectroscopy with detailed chemical modeling based on rate constants obtained from automated ab initio transition state theory-based master equation calculations and high-level thermochemical parametrizations. Broadband rotational spectroscopy offers quantitative and isomer-specific detection by which branching ratios of polar reaction products may be obtained. Using this technique, we observe and characterize products arising from H atom substitution reactions in the flash pyrolysis of acetone (CH 3 C(O)CH 3 ) at a nominal temperature of 1800 K. The major product observed is ketene (CH 2 CO). Minor products identified include acetaldehyde (CH 3 CHO), propyne (CH 3 CCH), propene (CH 2 CHCH 3 ), and water (HDO). Literature mechanisms for the pyrolysis of acetone do not adequately describe the minor products. The inclusion of a variety of substitution reactions, with rate constants and thermochemistry obtained from automated ab initio kinetics predictions and Active Thermochemical Tables analyses, demonstrates an important role for such processes. Furthermore, the pathway to acetaldehyde is shown to be a direct result of substitution of acetone's methyl group by a free H atom, while propene formation arises from OH substitution in the enol form of acetone by a free H atom.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Modeling Seismic Recordings of High-Frequency Guided Infrasound on Mars

NASA's Interior Exploration using Seismic Investigations, Geodesy and Heat Transport (InSight) mission records several high-frequency (>0.5 Hz) dispersive seismic signals on Mars. These signals are due to the acoustic-to-seismic coupling of infrasound generated by the entry and impact of meteorites. This dispersion property is due to infrasound propagating in a structured atmosphere, and we refer to this dispersive infrasound as guided infrasound. We propose to model the propagation of guided infrasound and the seismic coupling to the ground analytically; we use a 1D layered atmosphere on a three-layer solid subsurface medium. The synthetic ground movements fit the observed dispersive seismic signals well and the fitting indicates that the regolith beneath InSight is about 40-m in thickness. We also examine and validate the previously-published subsurface models derived from InSight ambient seismic vibration data.

58 GEOSCIENCES↗

Terawatt-class femtosecond long-wave infrared laser

We utilized a nonlinear post-compression technique to generate 675-fs, 9.2-μm CO 2 laser pulses with a peak power of 1.6 TW. This achievement represents the highest peak power ever attained in the femtosecond pulse format within the long-wave infrared (LWIR) spectral range. The successful implementation of this post-compression technique opens avenues for the development of few-cycle, multi-terawatt 9–10 μm lasers, crucial for applications currently relying on near-infrared solid-state lasers, and which stand to benefit from the scaling of laser wavelengths into the long-wave infrared region.

43 PARTICLE ACCELERATORS↗

Harnessing Ultra-Intense Long-Wave Infrared Lasers: New Frontiers in Fundamental and Applied Research

This review explores two main topics: the state-of-the-art and emerging capabilities of high-peak-power, ultrafast (picosecond and femtosecond) long-wave infrared (LWIR) laser technology based on CO2 gas laser amplifiers, and the current and advanced scientific applications of this laser class. The discussion is grounded in expertise gained at the Accelerator Test Facility (ATF) of Brookhaven National Laboratory (BNL), a leading center for ultrafast, high-power CO2 laser development and a National User Facility with a strong track record in high-intensity physics experiments. We begin by reviewing the status of 9–10 μm CO2 laser technology and its applications, before exploring potential breakthroughs, including the realization of 100 terawatt femtosecond pulses. These advancements will drive ongoing research in electron and ion acceleration in plasma, along with applications in secondary radiation sources and atmospheric energy transport. Throughout the review, we highlight how wavelength scaling of physical effects enhances the capabilities of ultra-intense lasers in the LWIR spectrum, expanding the frontiers of both fundamental and applied science.

43 PARTICLE ACCELERATORS↗

Final Report

Explore the source record for details and available documents.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗