Search NASA⌕ Search

SEARCH · Search NASA

Results for “code requirements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Recommendations for Minimum Required Diagnostics Information for Electric Vehicle Charging Infrastructure

The rapid growth of electrified transportation, including light- and medium-duty electric vehicles (EVs) as a mobility solution requires a reliable EV charging infrastructure. To advance charging reliability, the ChargeX Consortium reports “Recommendations for Minimum Required Error Codes for Electric Vehicle Charging Infrastructure” and “Implementation Guide for Minimum Required Error Codes in Electric Vehicle Charging Infrastructure” have provided recommendations for a set of minimum required error codes (MRECs), their functional and responsibility classifications, and a guide for their implementation using OCPP versions 1.6J and 2.0.1. These reports outline a recommended practice for consistent error reporting and interpretation, which is essential for communicating issues uniformly across the complex and diverse EV charging ecosystem. However, MRECs are just one part of diagnosing issues, another critical part is obtaining enough information about the current state and performance of the various charging components to identify root causes for each of the error codes. This additional diagnostics data can be used by technicians or automated systems to understand the context around an issue, allowing for timely resolution, decreased maintenance costs, and increased charging reliability. During everyday operations, data is regularly collected and analyzed across the ecosystem. Although sharing of all that available data would be great for diagnostics, concerns on data ownership, privacy, and OEM intellectual property pose a challenge. To overcome this obstacle, this report proposes a set of Minimum Required Diagnostic Information (MRDI) and recommends that the industry implement these uniformly across the North American EV charging ecosystem. MRDI provides a means to exchange only data deemed necessary for root cause determination.

32 - ENERGY CONSERVATION, CONSUMPTION, AND UTILIZA↗

Field Testing of Compartmentalization Methods for Multifamily Construction

The 2012 International Energy Conservation Code (IECC) has an airtightness requirement of 3 air changes per hour at 50 Pascals test pressure (3 ACH50) for single-family and multifamily construction (in climate zones 3–8). The Leadership in Energy & Environmental Design certification program and ASHRAE Standard 189 have comparable compartmentalization requirements. ASHRAE Standard 62.2 will soon be responsible for all multifamily ventilation requirements (low rise and high rise); it has an exceptionally stringent compartmentalization requirement. These code and program requirements are driving the need for easier and more effective methods of compartmentalization in multifamily buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building Energy Codes and Grid-Interactive Efficient Buildings: How building energy codes can enable a more dynamic and energy-efficient built environment

This report considers the role of national model codes to promote grid-interactive efficient buildings (GEBs) as part of the modernization of the U.S. electricity grid. It introduces GEBs, describes their ability to support a clean, resilient grid, and considers challenges and approaches for incorporating GEB measures into national model energy codes and standards. Desirable traits of GEB include being low energy, low peaking, and responsive to grid needs, and minimizing the curtailment of renewable energy resources. In addition, the future grid incurs a time and locational value on these types of building services. Accounting for these considerations in future code development requires a continuation and expansion of code-minimum energy efficiency requirements and inclusion of demand responsive and load flexibility measures while ensuring annual use and cost reductions. Also, efforts to include GEB measures in codes will be limited until they are fully developed into an American National Standards Institute (ANSI)-approved standard. Then it would be straightforward to address GEB measures through points or packages and/or scoring requirements. Otherwise, the building code would have to describe each specific grid responsive strategy. This document reviews topics pertinent to considering codes in this context. Specifically, the study presents the status and direction of current building energy codes, the future smart grid, low-energy buildings, and grid-integrated buildings. The report concludes with recommendations for future code development activities to support low-energy, grid-interactive buildings in order to provide added value to building owners, the grid, and society.

24 POWER TRANSMISSION AND DISTRIBUTION↗

iTOUGH2 Universal Optimization Using the PEST Protocol

iTOUGH2 (http://www-esd.lbl.gov/iTOUGH2) is a computer program for parameter estimation, sensitivity analysis, and uncertainty propagation analysis [Finsterle, 2007a, b, c]. iTOUGH2 contains a number of local and global minimization algorithms for automatic calibration of a model against measured data, or for the solution of other, more general optimization problems (see, for example, Finsterle [2005]). A detailed residual and estimation uncertainty analysis is conducted to assess the inversion results. Moreover, iTOUGH2 can be used to perform a formal sensitivity analysis, or to conduct Monte Carlo simulations for the examination for prediction uncertainties. iTOUGH2's capabilities are continually enhanced. As the name implies, iTOUGH2 is developed for use in conjunction with the TOUGH2 forward simulator for nonisothermal multiphase flow in porous and fractured media [Pruess, 1991]. However, iTOUGH2 provides FORTRAN interfaces for the estimation of user-specified parameters (see subroutine USERPAR) based on user-specified observations (see subroutine USEROBS). These user interfaces can be invoked to add new parameter or observation types to the standard set provided in iTOUGH2. They can also be linked to non-TOUGH2 models, i.e., iTOUGH2 can be used as a universal optimization code, similar to other model-independent, nonlinear parameter estimation packages such as PEST [Doherty, 2008] or UCODE [Poeter and Hill, 1998]. However, to make iTOUGH2's optimization capabilities available for use with an external code, the user is required to write some FORTRAN code that provides the link between the iTOUGH2 parameter vector and the input parameters of the external code, and between the output variables of the external code and the iTOUGH2 observation vector. While allowing for maximum flexibility, the coding requirement of this approach limits its applicability to those users with FORTRAN coding knowledge. To make iTOUGH2 capabilities accessible to many application models, the PEST protocol [Doherty, 2007] has been implemented into iTOUGH2. This protocol enables communication between the application (which can be a single 'black-box' executable or a script or batch file that calls multiple codes) and iTOUGH2. The concept requires that for the application model: (1) Input is provided on one or more ASCII text input files; (2) Output is returned to one or more ASCII text output files; (3) The model is run using a system command (executable or script/batch file); and (4) The model runs to completion without any user intervention. For each forward run invoked by iTOUGH2, select parameters cited within the application model input files are then overwritten with values provided by iTOUGH2, and select variables cited within the output files are extracted and returned to iTOUGH2. It should be noted that the core of iTOUGH2, i.e., its optimization routines and related analysis tools, remains unchanged; it is only the communication format between input parameters, the application model, and output variables that are borrowed from PEST. The interface routines have been provided by Doherty [2007]. The iTOUGH2-PEST architecture is shown in Figure 1. This manual contains installation instructions for the iTOUGH2-PEST module, and describes the PEST protocol as well as the input formats needed in iTOUGH2. Examples are provided that demonstrate the use of model-independent optimization and analysis using iTOUGH2.

15 GEOTHERMAL ENERGY↗

SURVEY OF COUPLING SCHEMES IN TRADITIONAL COUPLED NEUTRONICS AND THERMAL-HYDRAULICS CODES

The design and the analysis of nuclear power plants (NPPs) require computational codes to predict the behavior of the NPP nuclear components and other systems (i.e., reactor core, primary coolant system, emergency core cooling system, etc.). Coupled calculations are essential to the conduct of deterministic safety assessments. Inasmuch as the physical phenomena that govern the performance of a nuclear reactor are always present simultaneously, ideally computational modeling of a nuclear reactor should include coupled codes that represent all of the active physical phenomena. Such multi-physics codes are under development at several institutions and are expected to become operational in the future. However, in the interim, integrated codes that incorporate modeling capabilities for two to three physical phenomena will remain useful. For example, in the conduct of safety analyses, of paramount importance are codes that couple neutronics and thermal-hydraulics, especially transient codes. Other code systems of importance to safety analyses are those that couple primary system thermal-hydraulics to fission product chemistry, neutronics to fuel performance, containment behavior and structural mechanics to thermal-hydraulics, etc. This paper surveys the methods used traditionally in the coupling of neutronic and thermal-hydraulics codes. The neutron kinetics codes are used for computing the space-time evolution of the neutron flux and, hence, of the power distribution. The thermal-hydraulics codes, which compute mass, momentum and energy transfers, model the coolant flow and the temperature distribution. These codes can be used to compute the neutronic behavior and the thermal-hydraulic states separately. However, the need to account with fidelity for the dynamic feedback between the two sets of properties (via temperature and density effects on the cross section inputs into the neutronics codes) and the requirement to model realistically the transient response of nuclear power plants and to assess the associated emergency systems and procedures imply the necessity of modeling the neutronic and thermal-hydraulics simultaneously within a coupled code system. The focus of this paper is a comparison of the methods by which the coupling between neutron kinetics and thermal-hydraulics treatments has been traditionally achieved in various code systems. As discussed in the last section, the modern approaches to multi-physics code development are beyond the scope of this paper.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Assessing Occupant and Outdoor Air Impacts on Indoor Air Quality in New California Homes

In 2008 the State of California adopted new building codes that required the use of mechanical ventilation systems in homes that meet the requirements of ASHRAE Standard 62.2. The standard requires both a dwelling unit mechanical ventilation system and exhaust fans in kitchens and bathrooms. A field study was undertaken to evaluate the IAQ and ventilation performance of homes built to these requirements. For ventilation system performance, the airflows of all mechanical ventilation systems were measured and their use was monitored for a one-week period. To evaluate IAQ, key pollutants were measured indoors and outdoors during the week, and occupants completed satisfaction surveys. The key pollutants included: formaldehyde, humidity, PM2.5 and NO2. Passive samplers were used to determine average concentrations for the week. Active samplers were used to develop time-series results that can be used to correlate pollutant concentrations with occupant activities. Other ventilation/IAQ related parameters were also recorded, such as stove top temperatures to indicate cooking, exterior door contact switches to know when large openings were being used for ventilation and sensors to determine when clothes dryers were being used. The building envelope and duct leakage were measured to enable estimates of infiltration and duct leakage effects. This paper presents an overview of the test procedures and preliminary results from several homes. The results show that although average concentrations may be reasonable compared to available standards (with the exception of formaldehyde), occupants have a strong impact on pollutant variability and source strength and that outdoor concentrations cannot be ignored. Overall, these mechanically ventilated homes have reasonable IAQ. The homes and duct systems are moderately tight, though not excessively so, by US standards. Significant concerns have been expressed regarding compliance with the ventilation requirements in the California building code. However, almost all the ventilation systems in this study complied with the ventilation air flow requirements and on average were significantly higher than the minimum required air flow rates.

Walker, IS↗

Assessment and Mitigation of Radiation, EMP, Debris & Shrapnel Impacts at Megajoule-Class Laser Facilities

The generation of neutron/gamma radiation, electromagnetic pulses (EMP), debris and shrapnel at mega-Joule class laser facilities (NIF and LMJ) impacts experiments conducted at these facilities. The complex 3D numerical codes used to assess these impacts range from an established code that required minor modifications (MCNP - calculates neutron and gamma radiation levels in complex geometries), through a code that required significant modifications to treat new phenomena (EMSolve - calculates EMP from electrons escaping from laser targets), to a new code, ALE-AMR, that is being developed through a joint collaboration between LLNL, CEA, and UC (UCSD, UCLA, and LBL) for debris and shrapnel modelling.

36 MATERIALS SCIENCE↗

MetaboDirect: an analytical pipeline for the processing of FT-ICR MS-based metabolomic data

Background: Microbiomes are now recognized as the main drivers of ecosystem function ranging from the oceans and soils to humans and bioreactors. However, a grand challenge in microbiome science is to characterize and quantify the chemical currencies of organic matter (i.e., metabolites) that microbes respond to and alter. Critical to this has been the development of Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS), which has drastically increased molecular characterization of complex organic matter samples, but challenges users with hundreds of millions of data points where readily available, user-friendly, and customizable software tools are lacking. Results: Here, we build on years of analytical experience with diverse sample types to develop MetaboDirect, an open-source, command-line-based pipeline for the analysis (e.g., chemodiversity analysis, multivariate statistics), visualization (e.g., Van Krevelen diagrams, elemental and molecular class composition plots), and presentation of direct injection high-resolution FT-ICR MS data sets after molecular formula assignment has been performed. When compared to other available FT-ICR MS software, MetaboDirect is superior in that it requires a single line of code to launch a fully automated framework for the generation and visualization of a wide range of plots, with minimal coding experience required. Among the tools evaluated, MetaboDirect is also uniquely able to automatically generate biochemical transformation networks (ab initio) based on mass differences (mass difference network-based approach) that provide an experimental assessment of metabolite connections within a given sample or a complex metabolic system, thereby providing important information about the nature of the samples and the set of microbial reactions or pathways that gave rise to them. Finally, for more experienced users, MetaboDirect allows users to customize plots, outputs, and analyses. Conclusion: Application of MetaboDirect to FT-ICR MS-based metabolomic data sets from a marine phage-bacterial infection experiment and a Sphagnum leachate microbiome incubation experiment showcase the exploration capabilities of the pipeline that will enable the research community to evaluate and interpret their data in greater depth and in less time. It will further advance our knowledge of how microbial communities influence and are influenced by the chemical makeup of the surrounding system. The source code and User’s guide of MetaboDirect are freely available through (https://github.com/Coayala/MetaboDirect) and (https://metabodirect.readthedocs.io/en/latest/), respectively.

54 ENVIRONMENTAL SCIENCES↗

Performance portability for the CMS Reconstruction with Alpaka

For CMS, Heterogeneous Computing is a powerful tool to face the computational challenges posed by the upgrades of the LHC, and will be used in production at the High Level Trigger during Run 3. In principle, to offload the computational work on non-CPU resources, while retaining their performance, different implementations of the same code are required. This would introduce code-duplication which is not sustainable in terms of maintainability and testability of the software. Performance portability libraries allow to write code once and run it on different architectures with close-to-native performance. The CMS experiment is evaluating performance portability libraries for the near term future.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Model Energy Codes End-Use Opportunity Analysis

Model energy codes (ASHRAE Standard 90.1 and IECC) has significantly impacted programs and policies aimed at improving energy efficiency both in United States and across the globe. Standard 90.1, first published in 1975 (originally referred to as Standard 90) provides minimum energy efficiency guidelines for designing, constructing, operating, and maintaining new construction and renovated buildings. It is updated continuously, with new editions published every 3 years. Pacific Northwest National Laboratory (PNNL) conducts simulated energy and cost savings analysis of model energy codes to determine their expected impact and to track progress toward net-zero goals and efficiency targets. Additionally, the simulation outputs are examined to assess how energy is used across primary systems within prominent U.S. commercial building types to understand how energy is used in each building type at the end-use level and to identify areas for improvements in future code cycles. This end-use opportunity analysis of model energy codes provides ASHRAE technical committees and other interested parties a better understanding of how the Standard affects various building systems and end uses, specifically, those in the Standard that most prominently influence energy efficiency. Additionally, findings provide industry stakeholders guidance in identifying building types and end-uses with the most potential for energy efficiency improvements through energy codes and those that may require beyond code measures to meet energy use reduction targets. This paper summarizes features and functionalities of a webtool created by PNNL to explore and visualize the End-Use opportunity analysis.

ASHRAE 90.1, Energy Codes, Tableau↗

Sost , independent of the non-coding enhancer ECR5, is required for bone mechanoadaptation

Here, sclerostin ( Sost ) is a negative regulator of bone formation that acts upon the Wnt signaling pathway. Sost is mechanically regulated at both mRNA and protein level such that loading represses and unloading enhances Sost expression, in osteocytes and in circulation. The non-coding evolutionarily conserved enhancer ECR5 has been previously reported as a transcriptional regulatory element required for modulating Sost expression in osteocytes. Here we explored the mechanisms by which ECR5 , or several other putative transcriptional enhancers regulate Sost expression, in response to mechanical stimulation. We found that in vivo ulna loading is equally osteoanabolic in wildtype and Sost –/– mice, although Sost is required for proper distribution of load-induced bone formation to regions of high strain. Using Luciferase reporters carrying the ECR5 non-coding enhancer and heterologous or homologous h SOST promoters, we found that ECR5 is mechanosensitive in vitro and that ECR5 -driven Luciferase activity decreases in osteoblasts exposed to oscillatory fluid flow. Yet, ECR5 –/– mice showed similar magnitude of load-induced bone formation and similar periosteal distribution of bone formation to high-strain regions compared to wildtype mice. Further, we found that in contrast to Sost –/– mice, which are resistant to disuse-induced bone loss, ECR5 –/– mice lose bone upon unloading to a degree similar to wildtype control mice. ECR5 deletion did not abrogate positive effects of unloading on Sost , suggesting that additional transcriptional regulators and regulatory elements contribute to load-induced regulation of Sost .

59 BASIC BIOLOGICAL SCIENCES↗

Verification of a specialized hydrodynamic simulation code for modeling deflagration and detonation of high explosives

A specialized hydrodynamic simulation code has been developed and verified for the simulation of one-dimensional unsteady problems involving the detonation and deflagration of high explosives. To model all the relevant physical processes in these problems, a code is required to simulate compressible hydrodynamics, unsteady thermal conduction, and chemical reactions with complex rate laws. Several verification exercises are presented which test the implementation of these capabilities. The code also requires models for physics processes such as equations of state and conductivity for pure materials and mixtures as well as rate laws for chemical reactions. Additional verification tests are required to ensure that these models are implemented correctly. Though this code is limited in the types of problems it can simulate, its computationally efficient formulation allows it to be used in calibration studies for reactive burn models for high explosives. Furthermore, this study demonstrates how a series of verification tests can be used to ensure that the various physics processes needed to simulate complex phenomenon can be tested to ensure that they are correctly implemented.

97 MATHEMATICS AND COMPUTING↗

Methodology for Developing the REScheckTM Software through Version 4.2

This report explains the methodology used to develop Version 4.2 of the REScheck software developed for the 1992, 1993, and 1995 editions of the MEC, and the 1998, 2000, 2003, and 2006 editions of the IECC, and the 2006 edition of the International Residential Code (IRC). Although some requirements contained in these codes have changed, the methodology used to develop the REScheck software for these five editions is similar. REScheck assists builders in meeting the most complicated part of the code-the building envelope Uo-, U-, and R-value requirements in Section 502 of the code. This document details the calculations and assumptions underlying the treatment of the code requirements in REScheck, with a major emphasis on the building envelope requirements.

99 GENERAL AND MISCELLANEOUS↗

Preserving Envelope Efficiency in Performance Based Code Compliance

The City of Seattle 2012 Energy Code (Seattle 2014), one of the most progressive in the country, is under revision for its 2015 edition. Additionally, city personnel participate in the development of the next generation of the Washington State Energy Code and the International Energy Code. Seattle has pledged carbon neutrality by 2050 including buildings, transportation and other sectors. The United States Department of Energy (DOE), through Pacific Northwest National Laboratory (PNNL) provided technical assistance to Seattle in order to understand the implications of one potential direction for its code development, limiting trade-offs of long-lived building envelope components less stringent than the prescriptive code envelope requirements by using better-than-code but shorter-lived lighting and heating, ventilation, and air-conditioning (HVAC) components through the total building performance modeled energy compliance path. Weaker building envelopes can permanently limit building energy performance even as lighting and HVAC components are upgraded over time, because retrofitting the envelope is less likely and more expensive. Weaker building envelopes may also increase the required size, cost and complexity of HVAC systems and may adversely affect occupant comfort. This report presents the results of this technical assistance. The use of modeled energy code compliance to trade-off envelope components with shorter-lived building components is not unique to Seattle and the lessons and possible solutions described in this report have implications for other jurisdictions and energy codes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Implementation of ASME Code, Section XI, Code Case N-770, on Alternative Examination Requirements for Class 1 Butt Welds Fabricated with Alloy 82/182

In May 2010, the NRC issued a proposed notice of rulemaking that includes a provision to add a new section to its rules to require licensees to implement ASME Code Case N-770, ‘‘Alternative Examination Requirements and Acceptance Standards for Class 1 PWR Piping and Vessel Nozzle Butt Welds Fabricated with UNS N06082 or UNS W86182 Weld Filler Material With or Without the Application of Listed Mitigation Activities, Section XI, Division 1,’’ with 15 conditions. Code Case N-770 contains baseline and inservice inspection (ISI) requirements for unmitigated butt welds fabricated with Alloy 82/182 material and preservice and ISI requirements for mitigated butt welds. The NRC stated that application of ASME Code Case N-770 is necessary because the inspections currently required by the ASME Code, Section XI, were not written to address stress corrosion cracking Alloy 82/182 butt welds, and the safety consequences of inadequate inspections can be significant. The NRC expects to issue the final rule incorporating this code case into its regulations in the spring 2011 time frame. This paper discusses the new examination requirements, the conditions that NRC is imposing , and the major concerns with implementation of the new Code Case.

alloy 82/182↗

Software Requirements for a Point Kinetics Neutronics Code for Simulating TREAT Reactor Transients

This document provides the software requirements for a computer code to perform point kinetics-based simulations of nuclear reactor transients. These requirements address all aspects of code development and use, including input and output parameters and structure, software capabilities, and supporting documentation. This software is intended to replace the existing point kinetics code TREKIN, which is currently used for the analysis of the Transient Reactor Test Facility (TREAT).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Spray: Sparse Reductions of Arrays in OPEN MP

We present SPRAY, an open-source header-only C++ library for sparse reductions of arrays. SPRAY is meant for applications in which a large array is collaboratively updated by multiple threads using an associative and commutative operation such as +=. Especially when each thread accesses only parts of the array, SPRAY can perform significantly better than OPENMP's built-in reduction clause or atomic updates, while also using less memory than the former. SPRAY provides both an easy-to-use interface that can serve as a drop-in replacement for OPENMP reductions and a selection of reducer objects that accumulate the final result in different thread-safe ways. We demonstrate SPRAY through multiple test cases including the LULESH shock hydrodynamics code and a transpose-matrix-vector multiplication for sparse matrices stored in CSR format. SPRAY reductions outperform built-in OPENMP reductions consistently, in some cases improving run time and memory overhead by 20X, and even beating domain-specific approaches such as Intel MKI, by over 2X in some cases. Furthermore, SPRAY reductions have a minimal impact on the code base, requiring only a few lines of source code changes. Once in place, SPRAY reduction schemes can be switched easily, allowing performance portability and tuning opportunities by separating performance-critical implementation details from application code.

OpenMP↗