Search NASA⌕ Search

SEARCH · Search NASA

Results for “cold”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

The JA‐responsive MYC2‐ BADH ‐ like transcriptional regulatory module in Poncirus trifoliata contributes to cold tolerance by modulation of glycine betaine biosynthesis

Summary Glycine betaine (GB) is known to accumulate in plants exposed to cold, but the underlying molecular mechanisms and associated regulatory network remain unclear. Here, we demonstrated that PtrMYC2 of Poncirus trifoliata integrates the jasmonic acid (JA) signal to modulate cold‐induced GB accumulation by directly regulating PtrBADH‐l , a betaine aldehyde dehydrogenase (BADH)‐like gene. PtrBADH‐l was identified based on transcriptome and expression analysis in P. trifoliata . Overexpression and VIGS (virus‐induced gene silencing)‐mediated knockdown showed that PtrBADH‐l plays a positive role in cold tolerance and GB synthesis. Yeast one‐hybrid library screening using PtrBADH‐l promoter as baits unraveled PtrMYC2 as an interacting candidate. PtrMYC2 was confirmed to directly bind to two G‐box cis ‐acting elements within PtrBADH‐l promoter and acts as a transcriptional activator. In addition, PtrMYC2 functions positively in cold tolerance through modulation of GB synthesis by regulating PtrBADH‐l expression. Interestingly, we found that GB accumulation under cold stress was JA‐dependent and that PtrMYC2 orchestrates JA‐mediated PtrBADH‐l upregulation and GB accumulation. This study sheds new light on the roles of MYC2 homolog in modulating GB synthesis. In particular, we propose a transcriptional regulatory module PtrMYC2‐PtrBADH‐l to advance the understanding of molecular mechanisms underlying the GB accumulation under cold stress.

Ming, Ruhong↗

Increased Quasi Stationarity and Persistence of Winter Ural Blocking and Eurasian Extreme Cold Events in Response to Arctic Warming. Part I: Insights from Observational Analyses

Abstract Part I of this study examines the relationship among winter cold anomalies over Eurasia, Ural blocking (UB), and the background conditions associated with Arctic warming over the Barents and Kara Seas (BKS) using reanalysis data. It is found that the intensity, persistence, and occurrence region of UB-related Eurasian cold anomalies depend strongly on the strength and vertical shear (VS) of the mean westerly wind (MWW) over mid–high-latitude Eurasia related to BKS warming. Observational analysis reveals that during 1951–2015 UB days are 64% (54%) more frequent during weak MWW (VS) winters, with 26.9 (28.4) days per winter, than during strong MWW (VS) winters. During weak MWW or VS winters, as frequently observed during 2000–15, persistent and large UB-related warming is seen over the BKS together with large and widespread midlatitude Eurasian cold anomalies resulting from increased quasi stationarity and persistence of the UB. By contrast, when the MWW or VS is strong as frequently observed during 1979–99, the cold anomaly is less intense and persistent and confined to a narrow region of Europe because of a rapid westward movement of the strong UB. For this case, the BKS warming is relatively weak and less persistent. The midlatitude cold anomalies are maintained primarily by reduced downward infrared radiation (IR), while the surface heat fluxes, IR, and advection all contribute to the BKS warming. Thus, the large BKS warming since 2000 weakens the meridional temperature gradient, MWW, and VS, which increases quasi stationarity and persistence of the UB (rather than its amplitude) and then leads to more widespread Eurasian cold events and further enhances the BKS warming.

54 ENVIRONMENTAL SCIENCES↗

HFIR Cold Source Upgrade Options

Several cold source configurations that provide 40% to 90% higher brightness than the reference cold source in broad ranges of wavelengths longer than ~ 2 Å were identified. These CS configurations use hydrogen volumes 2.5 to 4 times larger than the reference source, require a nearly pure para-hydrogen for operation (99% para-hydrogen was assumed in the calculations), and impose heating 1.9 to 2.7 times higher than the reference cold source. Implementation would require adding an ortho-para hydrogen converter and increasing the refrigeration capacity. The brightness increase varies considerably with energy through the cold and thermal neutron range; however, the shapes of the curves of the brightness-increase-versus-energy are very similar for all the configurations analyzed. Up to 2.3 times higher brightness is observed around 3 Å wavelength. The even higher gains of 3.1 at 35 Å are practically of lower interest. Meanwhile, around 1.5 Å a brightness decrease of up to 50% is seen for all but one configuration. The configurations with connected HB-1 and HB-4 beamtubes allow the extraction of neutron beams from both sides of the cold source, therefore effectively doubling the potential number of instruments served, while providing brightness increases in the 40 % to 90 % range. A higher intensity neutron source, which would deliver ~2 times more neutrons down the beamtube, at brightness increased up to 45 %, can be obtained by increasing the radius of the HB-4 and the cold source by ~ 1 cm; which can be realized within the restrictions imposed by the reactor vessel flanges.

47 OTHER INSTRUMENTATION↗

Characterization of oceanic post-cold frontal clouds and their model representation. Final report

Low-level clouds are ubiquitous over the oceans, and their impact on the Earth’ radiative budget is important. However, general circulation models (GCMs) that are used to represent our climate and its evolution still experience problems to represent their correct amount and radiative impact. In the extratropical latitudes (~30-60 N/S), cloud properties are strongly modulated by the occurrence of anti-cyclones (high pressure systems) and cyclones (low pressure systems). While deep clouds dominate in cyclones near the center and along the cold and warm fronts, low-level clouds populate the colder regions of the cyclones, and more specifically the region in the wake of the cold fronts, the post-cold frontal region (PCF). The GCMs mentioned above were found to underestimate the amount of these PCF clouds, and this caused errors in their representation of the amount of solar radiation at the surface of the southern hemisphere oceans, causing an excess in absorption and errors in long-term predictions. To better understand which processes are ill-represented in the GCMs to cause such issues, we used ground-based observations from the Eastern North Atlantic (ENA) ARM site and a high resolution regional model (called WRF) to examine the properties of PCF clouds. With the WRF model, we simulated the passage of a cold front at the ENA site using theoretically distinct representations of convection and the physics of the boundary layer. While these physical representations had little impact on the timing, structure and circulation of the cold front, we found a high sensitivity to how the large scale information was fed into the model. Errors rapidly developed if the incoming flow information was injected too far from the site, but 1000 km was found to be an optimal distance between the outer boundary and the ENA site for a realistic cold front passage. With this model, we then conducted a series of experiment where convection and boundary layer schemes were changed, and revealed that 1) the clouds were more sensitive to the convection than boundary layer schemes and 2) the interaction between the two has a large impact. Furthermore, changing the representation of the physics in the model had greater impacts on PCF clouds than changing the initial conditions. As large-scale models increase their spatial resolution, convection will eventually be resolved but it remains that their representation of the physics of the boundary layer will matter for the correct representation of shallow (low-level) clouds. Observations were used to find which large-scale information had a clear relationship with PCF cloud and precipitation properties, in view of helping with GCM parameterizations and evaluation. Both lower troposphere stability and surface forcing were found to be important for PCF clouds that experience more vigorous dynamics than their tropical or subtropical counterparts. For cloud base and top heights, a simple measure of the change in potential temperature between the surface and the 800 hPa was found to be a good predictor. This relationship was found to hold as well when using data from campaigns recently conducted in the southern ocean south of Tasmania. A recent GCM was found to succeed in representing similar relations. For cloud depth, water content, and different characteristics of precipitation both the temperature contrast between the surface and near-air and the near-surface wind speed had a strong relationship. To summarize, through observational constraints and regional model experiments, the project has provided guidance to evaluate GCMs and tools to improve their representation of low-level clouds in the extratropics. It has also highlighted differences in behavior between these clouds and those typically found in the subtropics, thus opening new avenues of research for shallow clouds in general.

54 ENVIRONMENTAL SCIENCES↗

FY2022 Status Report: Cold Spray for Canister SCC Mitigation and Repair

This progress report describes work performed during FY22 at Sandia National Laboratories (SNL) to assess the corrosion performance of cold spray coatings to enable optimization of cold spray for the purposes of mitigation and/or repair of potentially susceptible regions, corrosion, or stress corrosion cracking (SCC) in austenitic stainless steel for spent nuclear fuel (SNF) storage. Of particular concern is SCC, by which a through-wall crack could potentially form in a canister outer wall over time intervals that may be shorter than possible dry storage times. In FY21, initial corrosion explorations of cold spray coating were evaluated and in FY22, an expanded set of cold spray coatings with in-depth analysis of post-exposure accelerated testing was explored. Additionally, relevant atmospheric exposure testing was carried out and initial results are presented herein. The corrosion attack from the accelerated testing and more realistic atmospheric exposures environments were compared to identify potentially deleterious factors for corrosion as well as help to understand the applicability of accelerated testing for cold spray optimization. This initial analysis will help to enable optimization of the corrosion resistance cold spray, one of the more promising coating and repair techniques, for potential application in an SNF environment. Learnings from both are summarized, and implications and future work are presented in this report.

36 MATERIALS SCIENCE↗

Field Validation of Innovative Air-Source Heat Pumps for Cold-Climate Heating Applications

Air-source heat pumps (ASHPs) have historically found application in milder climates in the United States (US). Their application in cold climates has been hindered by reduced performance as outdoor temperatures fall below freezing and the need for backup or auxiliary electric resistance heaters to meet peak heating loads. Recent advances in cold-climate air-source heat pumps (ccASHPs) with features such as variable-speed compressors, multistage systems, and highly optimized thermal design have improved performance by increasing the coefficient of performance (COP), low-ambient-temperature capacity, and heating seasonal performance factor (HSPF) dramatically. Despite their benefits, ccASHPs are still not widely prescribed for cold climate conditions. This is due in part to a lack of verified, demonstrated performance and analysis in cold climates. Ultimately, high-efficiency ccASHPs play a key role in emerging energy/grid renovation efforts in addition to their potential energy savings and avoided carbon emissions, but their actual performance in various cold climate field settings must be better understood. The primary objective of this project was to measure the in-field performance of variable-capacity air-source heat pumps in cold climates with the goal of enabling the development of field-based performance maps. Specifically, the study looked at how the heat pumps operated in the field, the frequency of cycling, the frequency of defrost events, and the time spent in each mode of operation. The results are intended to be used by DOE to inform research and development of energy-efficient equipment and to develop guidelines for optimizing primary energy savings when using air-source heat pumps in heating-dominated regions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of a Cold Start Fuel Penalty Metric for Evaluating the Impact of Fuel Composition Changes on SI Engine Emissions Control

The U.S. Department of Energy’s Co-Optimization of Fuels and Engines initiative (Co-Optima) aims to simultaneously transform both transportation fuels and engines to maximize performance and energy efficiency. Researchers from across the DOE national laboratories are working within Co-Optima to develop merit functions for evaluating the impact of fuel formulations on the performance of advanced engines. The merit functions relate overall engine efficiency to specific measurable fuel properties and will serve as key tools in the fuel/engine co-optimization process. This work focused on developing a term for the Co-Optima light-duty boosted spark ignition (SI) engine merit function that captures the effects of fuel composition on emissions control system performance. For stoichiometric light-duty SI engines, the majority of NOx, NMOG, and CO emissions occur during cold start, before the three-way catalyst (TWC) has reached its “light-off” temperature. This light-off temperature depends on the exhaust composition, which changes with fuel formulation. Thus, the time to achieve light-off, and therefore the cold start emissions, depends on fuel composition. Since the time to reach light-off must be minimized to meet emissions regulations, modern vehicles employ cold start strategies that intentionally release fuel energy into the engine exhaust to heat the TWC above the light-off temperature as quickly as possible. The fuel penalty associated with catalyst heating during cold start provides a link between fuel properties, emissions performance, and engine efficiency. This paper describes the derivation of the Co-Optima SI engine merit function term for emissions control, which is based on the cold start fuel penalty for catalyst heating and the catalytic light-off temperature for a particular fuel composition. It also discusses the process used for extracting cold start fuel penalties from chassis dynamometer data sets previously collected at ORNL. The form of the merit function term is simple, but it is only intended as a starting point for comparing the potential impacts of changes in fuel formulation on emissions control system performance.

Pihl, Josh↗

The measurement of cold ion densities in the plasma trough

The cold ion density in the plasma trough region is an important fundamental parameter in the currently proposed mechanisms to describe magnetospheric dynamics. Direct in situ measurements of the cold ion density are generally difficult owing to uncertainties in vehicle potentials and ion temperatures. It is shown that the light ion mass spectrometer from Ogo 5 was very successful in acquiring these data and that vehicle potentials appear not to have been a prohibitive factor. The cold ion plasma trough data show a great deal of variability, indicating a strong dependence on the state of the convection electric field; consequently, average values of cold ion densities in the plasma trough may be significantly different from the actual time-dependent values. The local time plot of plasma trough densities at L = 7 for data acquired over a 1-year period shows the anticipated increase in cold ion density during the daytime and the expected decrease in cold ion density during dusk and early nighttime.

Harris, K. K.↗

Evaluation of scramjet combustor performance using cold nonreactive mixing tests

Results of cold supersonic ducted mixing tests are presented and compared with results of hot mixing and combustion tests obtained using the same apparatus. Two strut injectors are evaluated, one with injectors parallel to the free-stream direction and one with perpendicular injectors. Detailed flow surveys are used to determine the degree of mixing accomplished in the cold flow tests. In the hot flow tests, the amount of mixing and reaction is inferred from survey data and comparison of wall static pressures with one-dimensional flow calculations. These comparisons show that cold mixing results can be used to predict combustion results. In some cases, such as the normal injection strut tested, cold mixing efficiency and combustion efficiency are identical. In other cases, transport models developed from cold flow results can be applied to predict the effects of higher temperature mixing and reaction. Cold flow surveys are also used to determine detailed flow characteristics not readily measured in hot flows.

Mcclinton, C. R.↗

Interactions between gravity waves and cold air outflows in a stably stratified uniform flow

Interactions between gravity waves and cold air outflows in a stably stratified uniform flow forced by various combinations of prescribed heat sinks and sources are studied using a hydrostatic two-dimensional nonlinear numerical model. The formation time for the development of a stagnation point or reversed flow at the surface is not always directly proportional to the Froude number when wave reflections exist from upper levels. A density current is able to form by the wave-otuflow interaction, even though the Froude number is greater than a critical value. This is the result of the wave-outflow interaction shifting the flow response to a different location in the characteristic parameter space. A density current is able to form or be destroyed due to the wave-outflow interaction between a traveling gravity wave and cold air outflow. This is proved by performing experiments with a steady-state heat sink and an additional transient heat source. In a quiescent fluid, a region of cold air, convergence, and upward motion is formed after the collision between two outflows produced by two prescribed heat sinks. After the collision, the individual cold air outflows lose their own identity and merge into a single, stationary, cold air outflow region. Gravity waves tend to suppress this new stationary cold air outflow after the collision. The region of upward motion associated with the collision is confined to a very shallow layer. In a moving airstream, a density current produced by a heat sink may be suppressed or enhanced nonlinearly by an adjacent heat sink due to the wave-outflow interaction.

Lin, Yuh-Lang↗

Modeling the Stability of Volatile Deposits in Lunar Cold Traps

There are several mechanisms acting at the cold traps that can alter the inventory of volatiles there. Primarily, the lunar surface is bombarded by meteoroids which impact, melt, process, and redistribute the regolith. Further, solar wind and magnetospheric ion fluxes are allowed limited access onto the regions in permanent shadow. Also, although cold traps are in the permanent shadow of the Sun, there is a small flux of radiation incident on the regions from interstellar sources. We investigate the effects of these space weathering processes on a deposit of volatiles in a lunar cold trap through simulations. We simulate the development of a column of material near the surface of the Moon resulting from space weathering. This simulation treats a column of material at a lunar cold trap and focuses on the hydrogen content of the column. We model space weathering processes on several time and spatial scales to simulate the constant rain of micrometeoroids as well as sporadic larger impactors occurring near the cold traps to determine the retention efficiency of the cold traps. We perform the Monte Carlo simulation over many columns of material to determine the expectation value for hydrogen content of the top few meters of soil for comparison with Lunar Prospector neutron data.

Crider, D. H.↗

Detection of Intergranular Corrosion in Cold Plate Face Sheets

Cold plates are critical for cooling electronic systems in the shuttle. As a result of the environmental conditions in which they operate, water can condense between them and a support shelf. In some cases, this water results in intergranular corrosion in the face sheet. If the intergranular corrosion sufficiently penetrates the face sheet, a coolant leak could occur and jeopardize cold plate operation. This paper examines techniques for detecting and characterizing the intergranular corrosion, to enable recertification of cold plates that have been in operation for 15 plus years. Intergranular corrosion was artificially induced in the face sheets of a series of cold plate specimens using an electrochemical process. Some of the cold plate specimens were separated for destructive characterization of the extent of corrosion produced by the electrochemical process and to insure the induced corrosion was intergranular. The rest of the specimens were characterized nondestructively using several techniques. X-ray tomography and ultrasonic techniques provided the best indication of corrosion in these specimens and will be the focus of this paper. An x-ray tomography technique was shown to be the most effective technique for characterizing depth of the intergranular corrosion. From these measurements, corrosion profile maps were developed that were consistent with subsequent destructive evaluations of the specimens. This enabled the assessment of NDE (ondestructive evaluation) standards to evaluate the viability of other NDE techniques. Due to system constraints, a different technique must be used to inspect an entire cold plate. An ultrasonic technique was shown to be very reliable for detection of corrosion in the unbacked regions of the face sheet. The ultrasonic technique was performed in an alcohol bath to avoid additional corrosion during the NDE evaluation. A pulse echo technique that focuses on the RMS value of the signal is shown to be very sensitive to the presence of intergranular corrosion.

Winfree, William P.↗

Low-Level Cloud Variability over the Equatorial Cold Tongue in Observations and Models

A fourth paper now in press is, Low-level cloud variability over the equatorial cold tongue in observations and models, by D. K. Mansbach and J. R. Norris (2007, J. Climate). This study examined cloud and meteorological observations from satellite, surface, and reanalysis datasets and fount that monthly anomalies in low-level cloud amount and near-surface temperature advection are strongly negatively correlated on the southern side of the equatorial Pacific cold tongue. This inverse correlation occurs independently of relationships between cloud amount and sea surface temperature (SST) or lower tropospheric static stability (LTS) and the combination of advection plus SST or LTS explains significantly more interannual cloud variability in a multilinear regression than does SST or LTS alone. Warm anomalous advection occurs when the equatorial cold tongue is well defined and the southeastern Pacific trade winds bring relatively warm air over colder water. Ship meteorological reports and soundings show that the atmospheric surface layer becomes stratified under these conditions, thus inhibiting the upward mixing of moisture needed to sustain cloudiness against subsidence and entrainment drying. Cold anomalous advection primarily occurs when the equatorial cold tongue is weak or absent and the air-sea temperature difference is substantially negative. These conditions favor a more convective atmospheric boundary layer, greater cloud amount, and less frequent occurrence of clear sky. Examination of output from global climate models developed by the Geophysical Fluid Dynamics Laboratory (GFDL) and the National Center for Atmospheric Research (NCAR) indicates that both models generally fail to simulate the cloud-advection relationships observed on the northern and southern sides of the equatorial cold tongue. Although the GFDL atmosphere model does reproduce the expected signs of cloud-advection correlations when forced with prescribed historical SST variations, it does not consistently do so when coupled to an ocean model. The NCAR model has difficulty reproducing the observed correlations in both atmosphere-only and coupled versions. This suggests that boundary layer cloud parameterizations could be improved through better representation of the effects of advection over varying SST.

Mansbach, David K.↗

Avionics Box Cold Plate Damage Prevention

Problem Introduction: 1. Prevent Cold Plate Damage in Space Shuttle. 1a. The number of cold plate problems had increased from an average of 16.5 per/year between 1990 through 2000, to an average of 39.6 per year between 2001through 2005. 1b. Each complete set of 80 cold plates cost approximately $29 million, an average of $362,500 per cold plate. 1c It takes four months to produce a single cold plate. 2. Prevent Cold Plate Damage in Future Space Vehicles.

Stambolian, Damon B.↗

Cold Ion Demagnetization near the X-line of Magnetic Reconnection

Although the effects of magnetic reconnection in magnetospheres can be observed at planetary scales, reconnection is initiated at electron scales in a plasma. Surrounding the electron diffusion region, there is an Ion-Decoupling Region (IDR) of the size of the ion length scales (inertial length and gyroradius). Reconnection at the Earths magnetopause often includes cold magnetospheric (few tens of eV), hot magnetospheric (10 keV), and magnetosheath (1 keV) ions, with different gyroradius length scales. We report observations of a subregion inside the IDR of the size of the cold ion population gyroradius (approx. 15 km) where the cold ions are demagnetized and accelerated parallel to the Hall electric field. Outside the subregion, cold ions follow the E x B motion together with electrons, while hot ions are demagnetized. We observe a sharp cold ion density gradient separating the two regions, which we identify as the cold and hot IDRs.

Toledo-Redondo, Serio↗

Actively controlling coolant-cooled cold plate configuration

A method is provided to facilitate active control of thermal and fluid dynamic performance of a coolant-cooled cold plate. The method includes: monitoring a variable associated with at least one of the coolant-cooled cold plate or one or more electronic components being cooled by the cold plate; and dynamically varying, based on the monitored variable, a physical configuration of the cold plate. By dynamically varying the physical configuration, the thermal and fluid dynamic performance of the cold plate are adjusted to, for example, optimally cool the one or more electronic components, and at the same time, reduce cooling power consumption used in cooling the electronic component(s). The physical configuration can be adjusted by providing one or more adjustable plates within the coolant-cooled cold plate, the positioning of which may be adjusted based on the monitored variable.

42 ENGINEERING↗

Heat Transfer Model of a Small-Scale Waste Glass Melter with Cold Cap Layer

At the Hanford site in the state of Washington, more than 56 million gallons of radioactive waste is stored in underground tanks. The cleanup plan for this waste is vitrification at the Waste Treatment Plant (WTP), currently under construction. At the WTP, the waste will be blended with glass-forming materials and heated to 1423K, then poured into stainless steel canisters to cool and solidify. A fundamental understanding of the glass batch melting process is needed to optimize the process to reduce cost and decrease the life cycle of the cleanup effort. The cold cap layer that floats on the surface of the glass melt is the primary reaction zone for the feed-to-glass conversion. The conversion reactions include water release, melting of salts, evolution of batch gases, dissolution of quartz and the formation of molten glass. Obtaining efficient heat transfer to this region is crucial to achieving high rates of glass conversion. Computational fluid dynamics (CFD) modeling is being used to understand the heat transfer dynamics of the system and provide insight to optimize the process. A CFD model was developed to simulate the DM1200, a pilot-scale melter that has been extensively tested by the Vitreous State Laboratory (VSL). Electrodes are built into the melter to provide Joule heating to the molten glass. To promote heat transfer from the molten glass into the reactive cold cap layer, bubbling of the molten glass is used to stimulate forced convection within the melt pool. A three-phase volume of fluid approach is utilized to model the system, wherein the molten glass and cold cap regions are modeled as separate liquid phases, and the bubbling gas and plenum regions are modeled as one lumped gas phase. The modeling of the entire system with a volume of fluid model allows for the prescription of physical properties on a per-phase basis. The molten glass phase and the gas phase physical properties are obtained from previous experimental work. Finding representative properties for the cold cap region is more difficult, as this region is not a true liquid, but rather a multilayer region consisting of a porous and a foamy layer. Physical properties affecting heat transfer, namely the thermal conductivity and heat capacity, have been fit to closely match data and observations from laboratory experiments. Data from xray tomography and quenching of laboratory-scale cold caps provide insight into the topology of bubble distribution within the cold cap at various temperatures. Heat transfer within the melter was validated by comparison with VSL data for the pilot-scale melter.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cold plate

A cold plate, an electronic assembly including a cold plate, and a method for forming a cold plate are provided. The cold plate includes an interface plate and an opposing plate that form a plenum. The cold plate includes a plurality of active areas arranged for alignment over respective heat generating portions of an electronic assembly, and non-active areas between the active areas. A cooling fluid flows through the plenum. The plenum, at the non-active areas, has a reduced width and/or reduced height relative to the plenum at the active areas. The reduced width and/or height of the plenum, and exterior dimensions of cold plate, at the non-active areas allow the non-active areas to flex to accommodate surface variations of the electronics assembly. The reduced width and/or height non-active areas can be specifically shaped to fit between physical features of the electronics assembly.

42 ENGINEERING↗