Search NASA⌕ Search

SEARCH · Search NASA

Results for “cold temperatures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Consolidation of A Sodium Heat Pipe and Stirling Engine for Fission Surface Power

The Consolidated Heat Pipe (CHP) is a new design in which a sodium heat pipe is welded directly to the hot end of the Stirling engine to deliver thermal power more efficiently. The new integrated interface aims to reduce the large temperature drop (about 120 °C) that was measured across the bolted clamp joint between the Stirling engine and the heat pipes during the Kilopower Reactor Using Stirling TechnologY (KRUSTY) test from 20181. Initial testing and characterization of the CHP was performed in ambient air at the NASA Glenn Research Center (GRC). In the test, the heat pipe evaporator section was heated with a tube furnace. The thermal power was then transported to the Stirling engine integrated with a linear alternator that produced electrical power. The CHP has been tested at a hot end temperature ranging from 600 °C - 800 °C and a variety of other Stirling engine parameters (cold end temperature, piston amplitude and pressure). The results show that the temperature drop between the Stirling engine and the heat pipe has been reduced to 2°C - 4 °C. An overall temperature drop of 20 °C – 60 °C was also noted within the heat pipe depending on the combination of parameters mentioned above. Overall, it has been shown that the new Consolidated Heat Pipe design significantly improved the thermal interface to the Stirling engine.

Consolidated↗

An Experimental Study on Low Pressure Frost Formation for Lunar Polar Water Capture

In-situ resource utilization (ISRU) is a vital component of NASA’s mission to the Moon and beyond, as the extraction of resources from the environment can reduce payload weight and the frequency of resupply missions. Since the discovery of water in the regolith of the permanently shadowed regions (PSR) of the Moon, its extraction and transport has become an area of increasing interest for NASA. One proposed method is heating icy regolith to free the water before desublimating and transporting it as ice in a tanker. However, little is known regarding the dynamics of frost growth at low pressures, and an understanding of the heat transfer process is required to properly size the heat exchanger for the tanker. To investigate this phenomenon, a cold plate was placed in a vacuum chamber with water vapor directed at its surface. The chamber pressure (300 and 500 Pa) and cold plate temperature (–18 to –5 °C) were kept below the triple point and varied throughout the experiment to examine their impact on frost layer heat transfer. As water flowed into the chamber and deposited on the cold plate surface, the heat flux and temperature were measured along with the frost layer thickness and/or mass. Density calculated at the conclusion of each test suggests the frost layer is denser than that of frost grown at atmospheric pressure. The results demonstrate unexpected density and heat transfer characteristics and require development of a new model of frost growth for lunar conditions.

In situ Resource Utiliztion↗

An Experimental Study on Low Pressure Frost Formation for Lunar Polar Water Capture

In-situ resource utilization (ISRU) is a vital component of NASA’s mission to the Moon and beyond, as the extraction of resources from the environment can reduce payload weight and the frequency of resupply missions. Since the discovery of water in the regolith of the permanently shadowed regions (PSR) of the Moon, its extraction and transport has become an area of increasing interest for NASA. One proposed method is heating icy regolith to free the water before de-sublimating and transporting it as ice in a tanker. However, little is known regarding the dynamics of frost growth at low pressures, and an understanding of the heat transfer process is required to properly size the heat exchanger for the tanker. To investigate this phenomenon, a cold plate was placed in a vacuum chamber with water vapor directed at its surface. The chamber pressure (300 and 500 Pa) and cold plate temperature (–18 to –5 °C) were kept below the triple point and varied throughout the experiment to examine their impact on frost layer heat transfer. As water flowed into the chamber and deposited on the cold plate surface, the heat flux and temperature were measured along with the frost layer thickness and/or mass. Density calculated at the conclusion of each test suggests the frost layer is denser than that of frost grown at atmospheric pressure. The results demonstrate unexpected density and heat transfer characteristics and require development of a new model of frost growth for lunar conditions

Lunar polar↗

Covariation of Mesoscale Ocean Color and Sea-Surface Temperature Patterns in the Sargasso Sea

During the lifetime of the Coastal Zone Color Scanner, there were 21 instances in which both satellite-derived ocean color and sea-surface temperature are simultaneously available over large areas of the Sargasso Sea. These images reveal close correspondence between mesoscale structures observed in temperature and pigment fields. In general, higher (lower) pigment biomass occurs in mesoscale features consisting of cold (warm) temperature anomalies. This relationship is consistent with the idea that upward displacement of isopycnals at the base of the euphotic zone by mesoscale eddies is an important mechanism of nutrient supply in the region.

McGillicuddy, Dennis J., Jr.↗

Covariation of Mesoscale Ocean Color and Sea-Surface Temperature Patterns in the Sargasso Sea

During the lifetime of the Coastal Zone Color Scanner, there were 21 instances in which both satellite-derived ocean color and sea-surface temperature are simultaneously available over large areas of the Sargasso Sea. These images reveal close correspondence between mesoscale structures observed in temperature and pigment fields. In general, higher (lower) pigment biomass occurs in mesoscale features consisting of cold (warm) temperature anomalies. This relationship is consistent with the idea that upward displacement of isopycnals at the base of the euphotic zone by mesoscale eddies is an important mechanism of nutrient supply in the region.

McGillicuddy, D. J.↗

A parametric study of electron multiharmonic instabilities in the magnetosphere

This paper presents numerical calculations of spatial growth rates of multiharmonic electron-cyclotron instabilities driven by a loss-cone energetic distribution, in the presence of colder electrons. When the cold electron density is comparable to the hot, nonconvective instability is possible in harmonic bands below or including the cold upper-hybrid frequency. When the cold electron density is larger than the hot, nonconvective instability is possible only in that band containing the cold upper-hybrid frequency. Increasing the cold electron temperature in relation to the hot eventually removes all nonconvective behavior. Convective instability is still possible above the cold upper-hybrid frequency.

Ashour-Abdalla, M.↗

Inductively-Coupled RF Powered O2 Plasma as a Sterilization Source

Low-temperature or cold plasmas have been shown to be effective for the sterilization of sensitive medical devices and electronic equipment. Low-temperature plasma sterilization procedures possess certain advantages over other protocols such as ethylene oxide, gamma radiation, and heat due to the use of inexpensive reagents, the insignificant environmental impacts and the low energy requirements. In addition, plasmas may also be more efficacious in the removal of robust microorganisms due to their higher chemical reactivity. Together, these attributes render cold plasma sterilization as ideal for the surface decontamination requirements for NASA Planetary Protection. Hence, the work described in this study involves the construction, characterization, and application of an inductively-coupled, RF powered oxygen (O2) plasma.

Sharma, S. P.↗

The Effect of Transfer Line Length and Heat Rejection Temperature Distribution on the Thales Linear Pulse Tube (LPT) Cryocoolers

Four Thales LPT9310 and four Thales LPT9510 commercial off-the-shelf (COTS) cryocoolers were parametrically performance tested. The LPT9310 coolers had transfer lines of various lengths while the LPT9510 coolers all had the same transfer line geometry. The LPT9510 test results revealed unit-tounit thermodynamic performance variation, quantified the effect of compressor temperature on thermodynamic performance and quantified the heat flow distribution between the compressor and expander as a function of their temperature distribution. The LPT9310 test results revealed the optimal drive frequency as a function of transfer line length, quantified the effect of heat rejection temperature distribution on thermodynamic performance and enabled the development and verification of a thermodynamic performance prediction tool that accounted for cold tip temperature, heat lift, heat rejection temperature and transfer line length.

Rodriguez, J.I.↗

Planar temperature measurement in compressible flows using laser-induced iodine fluorescence

A laser-induced iodine fluorescence technique that is suitable for the planar measurement of temperature in cold nonreacting compressible air flows is investigated analytically and demonstrated in a known flow field. The technique is based on the temperature dependence of the broadband fluorescence from iodine excited by the 514-nm line of an argon-ion laser. Temperatures ranging from 165 to 245 K were measured in the calibration flow field. This technique makes complete, spatially resolved surveys of temperature practical in highly three-dimensional, low-temperature compressible flows.

Hartfield, Roy J., Jr.↗

Subscale Injector Testing to Support Ares Engines Development

The J-2X and RS-68B rocket engines are being developed for NASA's Ares I and Ares V launch vehicles. In support of the development of these engines, hot-fire testing on subscale coaxial injectors has been performed at NASA s Marshall Space Flight Center (MSFC) to evaluate performance data relative to injector type, liquid oxygen (LOX) post tip design features, element density and various operating conditions. Shear coaxial injectors with element densities of 1.1, 1.6, and 2.3 elements/in2 and a swirl coaxial injector with element density of 1.6 elements/in2 were evaluated at conditions relevant to the Ares applications. Chamber pressures with oxygen/hydrogen propellants ranged from 815-1630 psig with mixture ratios ranging from 4.7-6.9. Fuel manifold inlet temperatures were varied from 90 to 270 R. Shear coaxial LOX post tip thicknesses ranged from 0.006 in. to 0.0175 in. Modular, water cooled, calorimeter chamber assemblies were used to provide heating rate data and evaluate the effects of characteristic length (L*). Performance was evaluated relative to the resulting characteristic velocity (C*) efficiency. Testing with both the 2.3 and 1.1 elements/in2 shear coaxial injectors demonstrated no improvement in performance of the "thin" tip configuration versus the "thick" tip configuration. The loss in chamber pressure and associated performance loss seen in previous testing at low fuel temperatures could not be reliably repeated, indicating that this loss is not the result of a fluidic process in the injector elements. Further, no performance loss could be demonstrated once a faceplate seal specifically designed for operation with low temperature hydrogen was implemented in the 1.1 elements/sq in shear coaxial injector. Results for the 1.6 elements/sq in swirl injector at cold fuel temperatures showed performance higher than both the 1.6 elements/in2 shear coaxial injector and the 2.3 elements/in2 shear coaxial injector.

Protz, Christopher↗

Adavanced RTG and thermoelectric materials study

A comprehensive, generalized two-dimensional RTG analysis computer program was developed. This program is capable of analyzing any specified RTG design under a wide range of transient as well as steady-state operating conditions. The feasibility of a new concept for the design of segmented (or single-phase) thermoelectric couples was demonstrated. A SiGe-PbTe segmented couple involving pressure contacted junctions at the intermediate- and hot-junction temperatures was successfully encapsulated in a hermetically sealed bellows enclosure. This bellows-encapsulated couple was operated between a hot- and cold-junction temperature of 1200 K and 450 K, respectively, with a measured energy conversion efficiency of 7.6 + or - .5 per cent. An experimental study of selected sublimation barrier schemes revealed that a significant reduction in the sublimation rate of p-type PbTe could be achieved by using multiple layers of SiO2 fibers. A comparison of the barrier effectiveness is given for three different barrier designs.

Eggers, P. E.↗

Applications of a Venus thermospheric circulation model

A variety of Pioneer Venus observations suggest a global scale, day-to-night Venus thermospheric circulation. Model studies of the dynamics and energetics of the Venus thermosphere are presented in order to address new driving, mixing and cooling mechanisms for an improved model simulation. The adopted approach was to reexamine the circulation by first using a previous two dimensional code to quantify those physical processes which can be inferred from the Pioneer Venus observations. Specifically, the model was used to perform sensitivity studies to determine the degree to which eddy cooling, eddy or wave drag, eddy diffusion and 15 micrometer radiational cooling are necessary to bring the model temperature and composition fields into agreement with observations. Three EUV heating cases were isolated for study. Global temperature and composition fields in good agreement with Pioneer data were obtained. Large scale horizontal winds 220 m/s were found to be consistent with the observed cold nightside temperatures and dayside bulges of O, CO and CO2. Observed dayside temperatures were obtained by using a 7 to 19% EUV heating efficiency profile. The enhanced 15 micrometer cooling needed for thermal balance is obtained using the best rate coefficient available for atomic O collisional excitation of CO2(0,1,0). Eddy conduction was not found to be a viable cooling mechanism due to the weakened global circulation. The strong 15 micrometer damping and low EUV efficiency imply a very weak dependence of the general circulation to solar cycle variability. The NCAR terrestrial thermospheric general circulation model was adapted for Venus inputs using the above two dimensional model parameters, to give a three dimensional benchmark for future Venus modelling work.

Bougher, S. W.↗

Mesoscale analysis of VAS 6.7 micron image data for several case studies

Several case studies are examined in an attempt to relate Visible infrared spin scan radiometers Atmospheric Sounder (VAS) water vapor channel radiance data to atmospheric moisture. Since the 6.7 micrometer channel detects radiation emitted by atmospheric water vapor from a rather thick layer, a scheme is developed which weighted rawinsonde observations of relative humidity in a similar manner. A comparison of the two fields (weighted relative humidity values from gridded rawinsonde observations and the VAS water vapor image) indicates that even when mesoscale data are used, the technique only presented a smooth representation of the radiance field. This weighting function is dependent on both the temperature and moisture distribution of the atmosphere. Cross sections of relative humidity from the mesoscale rawinsondes are produced which sliced the water vapor imagery in particularly interesting regions (areas of high and low blackbody temperatures). Comparisons are then made between the cross sections and the variations in the VAS radiance data along the cross section line. Bright regions in the water vapor imagery (cold blackbody temperatures) are often associated with thin layers of high relative humidity or thick layers of only moderately moist air. The reverse also applies, i.e., dark regions (warm blackbody temperatures) in the imagery corresponded well with very dry regions in the cross sections.

Jedlovec, G. J.↗

Mesoscale analysis of 6.7 micron image data from the VISSR Atmospheric Sounder (VAS) for several case studies

Several case studies are examined in an attempt to relate Visible infrared spin scan radiometers Atmospheric Sounder (VAS) water vapor channel radiance data to atmospheric moisture. Since the 6.7 micrometer channel detects radiation emitted by atmospheric water vapor from a rather thick layer, a scheme is developed which weighted rawinsonde observations of relative humidity in a similar manner. A comparison of the two fields (weighted relative humidity values from gridded rawinsonde observations and the VAS water vapor image) indicates that even when mesoscale data are used, the technique only presented a smooth representation of the radiance field. This weighting function is dependent on both the temperature and moisture distribution of the atmosphere. Cross sections of relative humidity from the mesoscale rawinsondes are produced which sliced the water vapor imagery in particularly interesting regions (areas of high and low blackbody temperatures). Comparisons are then made between the cross sections and the variations in the VAS radiance data along the cross section line. Bright regions in the water vapor imagery (cold blackbody temperatures) are often associated with thin layers of high relative humidity or thick layers of only moderately moist air. The reverse also applies, i.e., dark regions (warm blackbody temperatures) in the imagery corresponded well with very dry regions in the cross sections.

Jedlovec, G. J.↗

Silicon-On-Insulator (SOI) Devices and Mixed-Signal Circuits for Extreme Temperature Applications

Electronic systems in planetary exploration missions and in aerospace applications are expected to encounter extreme temperatures and wide thermal swings in their operational environments. Electronics designed for such applications must, therefore, be able to withstand exposure to extreme temperatures and to perform properly for the duration of the missions. Electronic parts based on silicon-on-insulator (SOI) technology are known, based on device structure, to provide faster switching, consume less power, and offer better radiation-tolerance compared to their silicon counterparts. They also exhibit reduced current leakage and are often tailored for high temperature operation. However, little is known about their performance at low temperature. The performance of several SOI devices and mixed-signal circuits was determined under extreme temperatures, cold-restart, and thermal cycling. The investigations were carried out to establish a baseline on the functionality and to determine suitability of these devices for use in space exploration missions under extreme temperatures. The experimental results obtained on selected SOI devices are presented and discussed in this paper.

Patterson, Richard↗

The lower hybrid density drift instability with cold plasma

The linear Vlasov dispersion relation for the lower hybrid density drift instability is studied in a four component (hot electrons and protons, cold electrons and protons) plasma. The introduction of a cold ion population monotonically reduces the maximum growth rate of the instability. Reduction of the ratio of temperatures of the cold and hot plasmas reduces both the real frequency and the growth rate of the instability. Near a ratio of the cold and hot plasma temperatures of 0.01 a higher frequency branch of this instability emerges and for a fixed ratio of cold and hot electron density exhibits an increasing maximum growth rate as the ratio of the cold and hot plasma temperatures decreases further. The ratio of the cold and hot plasma temperatures for the ions is the crucial parameter and deserves detailed magnetospheric studies.

Gary, S. P.↗

Dynamics of the Cold Water Event off the Southeast Coast of the United States in the Summer of 2003: An Application of NASA's Remote Sensing Data to Coastal Studies

The Moderate Resolution Imaging Spectroradiometer (MODIS) instruments onboard of Terra and Aqua satellites provide, for the first time, concurrent measurements of sea surface temperature (SST) and ocean color, which are suitable for coastal upwelling studies. The accuracy, the 1-km spatial resolution, and the almost complete daily coverage of the MODIS data compared with historical measurements make it advantageous for resolving important coastal fronts of chlorophyll concentration and temperature. The cold SST anomaly during summer 2003 off the coast of the South Atlantic Bight is an event that is comprehensively covered by NASA's MODIS and SeaWinds satellite observations. These data combined with in situ tide gauge, mooring, and ship measurements can be used to identify important dynamics responsible for the anomalous cold water event. The analysis of the data suggests that coastal upwelling occurs in the climatological summer forced by the climatological southerlies over the South Atlantic Bight area in summer. However, the strong buoyancy barrier in summer prevents the cold water below the thermocline from reaching the ocean surface. In summer 2003, the southwesterlies in July through August were extraordinarily strong and persistent, which generated the upwelling currents strong enough to overcome the buoyancy resistance. The results of this analysis demonstrate the possibility of monitoring and forecasting the event using combination of the satellite and in situ observations. The MODIS data are archived and distributed by the NASA's Goddard Earth Science (GES) Distributed Active Archive Center (DAAC). The data can be accessed via the URL http://wwv.daac.gsfc.nasa.gov/MODIS.

Yuan, Dongliang↗