Search NASA⌕ Search

SEARCH · Search NASA

Results for “collision cross section”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Measurement of the Higgs boson inclusive and differential fiducial production cross sections in the diphoton decay channel with pp collisions at $\sqrt{s}$ = 13 TeV

The measurements of the inclusive and differential fiducial cross sections of the Higgs boson decaying to a pair of photons are presented. The analysis is performed using proton-proton collisions data recorded with the CMS detector at the LHC at a centre-of-mass energy of 13 TeV and corresponding to an integrated luminosity of 137 fb -1 . The inclusive fiducial cross section is measured to be σ fid = 73.4$^{+5.4}_{-5.3}$ (stat)$a^{+2.4}_{-2.2 }$(syst) fb, in agreement with the standard model expectation of 75.4 ± 4.1 fb. The measurements are also performed in fiducial regions targeting different production modes and as function of several observables describing the diphoton system, the number of additional jets present in the event, and other kinematic observables. Two double differential measurements are performed. No significant deviations from the standard model expectations are observed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design of Hypervelocity Flow Generator (HFG) and Its Diagnostics

Ground facilities for hypersonic research are a key element for successful development of aerodynamically proven hypervelocity vehicles. Design concepts and diagnostics of a hypervelocity flow generator (HFG) were made as a test platform for hypersonic/hypervelocity spacecraft models at the NASA Langley Research Center. The HFG is a hypersonic flow field generator using optically heated gas which is blown into an 80 cu m vacuum chamber. The vacuum chamber is kept at a stable vacuum pressure with a combination of three large vacuum pumps, while the HFG is in the test mode. The HFG provides a relatively small test section with approximately a 20 cm window. This facility was designed to generate 2.45 km/sec of flow speed, and potentially generate a continuous flow with the nozzle and vacuum system. The window in test section provides a direct view of the shock wave around a model in order to measure temperature, pressure, and density profile within the shock layer. One of the key test goals under this project is to understand why the emission spectra from the standing shockwave plasma predicted by Lora-Loran codes are significantly different from the measured emission spectra from the Flight Investigation Reentry Environment (FIRE II) Flight. The correct estimate of the thermal loading on the leading edge of hypersonic vehicles greatly affects the aerodynamic design, the material selection for the vehicle, and the cooling requirement and can be obtained by the precise modeling of emission spectra from shockwave plasma. However, the estimation of thermal loading is not an easy task due to complex non-equilibrium radiative process within high temperature shock layers that still falls into a category of cold plasma. Direct flight experiments are the most desirable, but not a cost-effective approach. Analysis by computational fluid dynamics (CFD) offers many test flexibilities. However, the CFD codes must be fully tested and validated with experimental data before the codes are effectively used for practical design. Large discrepancies between experiments and codes appear in hypersonic/hypervelocity flow regimes at high altitudes of 60 km ~ 90 km. This HFG facility offers some important parameters for CFD code validation, such as collision cross-sections, relaxation times, reaction rate coefficients and transportation coefficients. The HFG test facility is based on the ejection flow of high temperature gas heated over to 3500 K through a nozzle. The tungsten gas chamber of the HFG is heated up to a desired temperature by a 60 kW optical power beam source. This system consists of an optical power source, a thermal chamber, an expansion nozzle, a test section, and an 80 cu m vacuum tank. 60 kW optical input power is obtained from the 150 kW Vortek arc lamp system (by Vortek Industries, Vancouver, Canada). This optical beam is focused to heat the gas chamber within which a flow media is heated. The maximum achievable temperature of the flow medium reached approximately 3500 K or even higher but is limited by the melting point of the chamber material used. The exhaust velocity through the nozzle was determined by the stagnation temperature and the molecular weight of the working medium at the test section. To provide design parameters, a NASA Chemical Equilibrium with Application (CEA) computer program is used for the simulation of aerothermal data. This CEA program can calculate chemical equilibrium and properties of complex mixtures using shock tube parameters. For nitrogen gas at 2666 K stagnation temperature, the maximum achievable velocity at the test section is approximately 2.45 km/sec which is within the range of the thermal velocity of 8000 K shock layer. Based on the calculation through the CEA program, the design parameters of a HFG were determined and implemented for the test section that includes an expansion nozzle. The installed test section of the experimental facility can sustain a condition of a re-entry vehicle from the Space at an altitude of 60-90 km. After installation of the HFG, the system was fully tested and its operational parameters were measured. An 80 cu m vacuum chamber of HFG was set at 1 torr level to keep a stable downstream condition. The pumping time to reach the minimum vacuum pressure (~ 1 torr) at the test chamber from atmospheric pressure was approximately an hour using Kinney (MBV-14000/MB -1600/KT-300) and Stokes (Model 1772 and 412) pumps. Such a setup condition allowed a continued stable operation of the HFG experiment with flowrates through 1-, 3-, or 5-mm diameters of nozzle throat. The flow characteristics of the HFG for various operating conditions were performed using a focused Schlieren method. At 0.8 torr chamber pressure, a barrel shock was observed at the test section. With a sphere obstacle of 12 mm diameter in the flow, a bow shock (~ 2-mm thickness) was observed by a focused Schlieren visualization method.

Hypervelocity flow↗

Study of exclusive photoproduction of charmonium in ultra-peripheral lead-lead collisions

The cross-sections of exclusive (coherent) photoproduction J/ψ and ψ(2S) mesons in ultra-peripheral PbPb collisions at a nucleon-nucleon centre-of-mass energy of 5.02 TeV are measured using a data sample corresponding to an integrated luminosity of 228 ± 10 µb -1 , collected by the LHCb experiment in 2018. The differential cross-sections are measured separately as a function of transverse momentum and rapidity in the nucleus-nucleus centre-of-mass frame for J/ψ and ψ(2S) mesons. The integrated cross-sections are measured to be $σ^{coh}_{J/ψ}$ = 5.965 ± 0.059 ± 0.232 ± 0.262 mb and $σ^{coh}_{ψ(2S)}$ = 0.923 ± 0.086 ± 0.028 ± 0.040 mb, where the first listed uncertainty is statistical, the second systematic and the third due to the luminosity determination. The cross-section ratio is measured to be $σ^{coh}_{ψ(2S)}$/$σ^{coh}_{J/ψ}$ = 0.155 ± 0.014 ± 0.003, where the first uncertainty is statistical and the second is systematic. These results are compatible with theoretical predictions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Positron collisions with alkali-metal atoms

The total cross sections for positron and electron collisions with potassium, sodium, lithium and rubidium are calculated, employing the modified Glauber approximation. The Modified Glauber cross sections for positron collision with potassium and sodium at low intermediate energies are found to agree reasonably well with existing experimental data.

Gien, T. T.↗

Computational tools and algorithms for ion mobility spectrometry-mass spectrometry

Ion mobility spectrometry-mass spectrometry (IMS-MS or IM-MS) is a powerful analytical technique that combines the gas-phase separation capabilities of IM with the identification and quantification capabilities of MS. IM-MS can differentiate molecules with indistinguishable masses but different structures (e.g., isomers, isobars, molecular classes, and contaminant ions). The importance of this analytical technique is reflected by a staged increase in the number of applications for molecular characterization across a variety of fields, from different MS-based omics (proteomics, metabolomics, lipidomics, etc.) to the structural characterization of glycans, organic matter, proteins, and macromolecular complexes. With the increasing application of IM-MS there is a pressing need for effective and accessible computational tools. This article presents an overview of the most recent free and open-source software tools specifically tailored for the analysis and interpretation of data derived from IM-MS instrumentation. This review enumerates these tools and outlines their main algorithmic approaches, while highlighting representative applications across different fields. Finally, a discussion of current limitations and expectable improvements is presented.

59 BASIC BIOLOGICAL SCIENCES↗

Discovery of a Ferromagnetic Nickel Chalcogenide Nanocluster Ni 3 S 3 H(PEt 3 ) 5

Atomically precise ligated nanoclusters (NC) are promising cluster-based materials with novel molecular architectures and tunable magnetic properties. Herein, the synthesis and characterization of a nickel sulfide NC Ni 3 S 3 H(PEt 3 ) 5 (PEt 3 = triethylphosphine) with distinct magnetic properties are reported. Magnetization measurements reveal its magnetic moment of 1.5 µ B in the solid phase, consistent with the existence of one unpaired electron predicted by density functional theory (DFT) calculations. Additionally, experimental measurements indicate the presence of ferromagnetic ordering within each Ni 3 S 3 H(PEt 3 ) 5 NC and strong coercivity at temperatures below 20 K. Ion mobility-mass spectrometry is employed in conjunction with DFT calculations and collision cross-section simulations to investigate the structure of the isolated Ni 3 S 3 H(PEt 3 ) 5 . Theoretical studies show that [Ni 3 S 3 H(PEt 3 ) 5 ] + has a planar Ni 3 S 3 core where three Ni atoms are arranged in a triangle with three bridging S atoms residing in the same plane. This structure is preserved in both solution and solid phases, which is confirmed by spectroscopic studies of Ni 3 S 3 H(PEt 3 ) 5 . Additionally, DFT calculations indicate that all spins at the Ni sites are aligned parallel, confirming the presence of ferromagnetic coupling. Overall, this study provides key insights into the structure and magnetic properties of Ni 3 S 3 H(PEt 3 ) 5 , which will facilitate the design of new NC-based magnetic materials.

Nickel sulfide nanocluster↗

Collision operator for electron runaway in cold weakly ionised plasmas

In cold weakly ionised plasmas, the Dreicer generation mechanism can be non-diffusive as demonstrated in a recent study. By expanding the previous letter, we present the detailed description of a proper collision operator to precisely account for the non-diffusive electron kinetics. The operator appropriately combines the Fokker–Planck operator and Boltzmann operator where free-bound collision cross-sections are valid in the low-energy region. The proposed operator is envisaged to predict runaway electron generation in cold weakly ionised plasmas, particularly to design a runaway-free reactor tokamak start-up.

fusion plasma↗

Cyclable Variable Path Length Multilevel Structures for Lossless Ion Manipulations (SLIM) Platform for Enhanced Ion Mobility Separations

Ion mobility-mass spectrometry (IMS-MS) is increasingly used to analyze complex samples and provide structural information of unknown compounds. As the complexity of samples increases, there is a need to improve the resolution of IMS-MS instruments to increase the rate of molecular identification. In this work, we evaluated a cyclable and variable-pathlength multilevel Structures for Lossless Ion Manipulations (SLIM) platform to achieve a higher resolving power than previously possible. This new multilevel SLIM platform has eight separation levels connected by ion escalators and a path length of ~88 meters (~11 meters per level). Our new multilevel SLIM can also be operated in an ‘ion cycling’ mode where a set of return ion escalators transport ions from the eighth back to the first level, allowing even longer path lengths (and higher IMS resolution). The platform has been improved to enhance the ion transmission and IMS separation quality by reducing the spacing between SLIM boards as well as board thickness, reducing the ions’ escalator residence time. Compared to the previous generation, the new multilevel SLIM demonstrated a better transmission for a set of phosphazene ions, especially for the low-mobility ions. The new multilevel SLIM achieved better resolving powers than our previous 4-level SLIM. The collision cross-section-based resolving power of the SLIM platform was tested using a pair of singly-charged reverse sequence peptides (SDGRG 1+ , GRGDS 1+ ). We achieved 1100 resolving power using 88 meters of path length (i.e., 8 levels) and 1400 following an additional pass through the eight levels (i.e., 16 levels or 173.5 m). The multilevel SLIM was further evaluated to demonstrate the enhanced separation for a positively and negatively charged brain total lipid extract sample. Finally, the new multilevel SLIM enables much higher resolving powers for a wide range of ion mobilities, improved transmission for low-mobility ions, and the ability to perform even higher resolving power for ions of interest.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Plasma diagnostics and modeling of lithium-containing plasmas

Thin-film deposition from chemically reactive multi-component plasmas is complex, and the lack of electron collision cross-sections for even the most common metalorganic precursors and their fragments complicates their modeling based on fundamental plasma physics. This study focuses on understanding the plasma physics and chemistry in argon (Ar) plasmas containing lithium bis (trimethylsilyl) amide used to deposit Li x Si y thin films. These films are emerging as potential solid electrolytes for lithium-ion batteries, and the Li-to-Si ratio is a crucial parameter to enhance their ionic conductivity. We deposited Li x Si y films in an axial flow-through plasma reactor and studied the factors that determine the variation of the Li-to-Si ratio in films deposited at various points on a substrate spanning the entire reactor axis. While the Li-to-Si ratio is 1:2 in the precursor, the Li-to-Si ratio is as high as 3:1 in films deposited near the plasma entrance and decreases to 1:1 for films deposited downstream. Optical emission from the plasma is dominated by Li emission near the entrance, but Li emission disappears downstream, which we attribute to the complete consumption of the precursor. We hypothesized that the axially decreasing precursor concentration affects the electron energy distribution function in a way that causes different dissociation efficiencies for the production of Li and Si. We used Li line intensities to estimate the local precursor concentration and Ar line ratios to estimate the local reduced electric field to test this hypothesis. This analysis suggests that the mean electron energy increases along the reactor axis with decreasing precursor concentration. As a result, the decreasing Li-to-Si ratio with axially decreasing precursor concentration may be explained by Li release from the precursor having lower threshold energy than Si release.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Investigation of SF6 Alternatives in Spark Gap Switches for GWP Reduction

This primary purpose of this project was to evaluate alternative gas mixtures to sulfur hexafluoride (SF6) developed for high voltage power delivery applications for use in high voltage spark gap switches. These SF6 alternatives lower global warming potential emissions and enable improvements to the pressure-voltage design space. A combined experimental, computational, and theoretical study was used to quantify the impact of persistent breakdown products on the breakdown distribution of SF6-replacement gas mixtures. Viable SF6 replacements suitable for use in spark gap switches were studied to enable performance and agility improvements for next-generation pulsed power research relevant to national security missions. Experimental campaign included establishing parameters of switch gases as function of concentration. Various concentrations and pressures were tested for trends in breakdown voltage, repeatability, and durability, and breakdown constituents. A zero-dimensional plasma global model was used to simulate the plasma arc decay and recombination process in spark-gap switches relevant to the Z machine. Finally, a complete and consistent set of electron-neutral collision cross-sections for the novel insulating gas C4F7N is reported.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development and implementation of high-throughput proteomic and metabolomics assays by using advanced chromatographic and mass spectrometric systems (CRADA Final Report)

The mission of this CRADA with Agilent was to couple powerful MS platforms (QQQ, IM-QTOFMS) with Agilent’s novel Ultra-High-Performance Liquid Chromatography (UHPLC) fast metabolomic workflows and perform ABF Machine Learning (ML) to generated datasets. Agilent transferred UHPLC methods to PNNL and LBNL and methods were implemented and demonstrated in both labs, achieving total acquisition times of < 10 min. Metabolites analyzed using Agilent’s shared methods included metabolites from central carbon metabolism, common across hosts, and metabolites unique to engineered strains. Standards were acquired in an UHPLC-Drift Tube Ion Mobility Mass Spectrometer (DTIMS) system for the first time within the context of ABF and methods were optimized based on Agilent’s protocols. Samples from ABF hosts Pseudomonas putida, Aspergillus pseudoterreus, Aspergillus niger and Rhodosporidium toruloides were analyzed using the UHPLC-DTIMS platform for a total of 276 runs. A data analysis workflow compatible with the Experimental Data Depot (EDD) and completely shareable was developed for the acquired UHPLC-DTIMS data. Samples were analyzed using a Data Independent Acquisition Approach (DIA), which for most of the standards provided more transitions therefore increasing detection confidence. Using the data acquired by PNNL, LBNL, and Agilent’s specifications from previous ML projects, SNL applied an ensemble ML strategy to pick the best performing model for automated LC-method selection. Finally, with the contribution of the participant labs and Agilent, SNL developed an Automated Method Selection (AMS) software tool to predict the best liquid chromatography method for analysis of any new molecules of interest. Samples with novel pathways and new metabolite targets of interest are generated at a high pace in the ABF. Overall, the project advanced rapid metabolomics by combining liquid chromatography, ion mobility spectrometry, and data-independent mass spectrometry with machine learning. This multidimensional approach uses retention time, collision cross-section, precursor mass, and fragment-ion information to distinguish chemically similar metabolites that can be difficult to resolve using conventional liquid- or gas-chromatography methods. The resulting workflow also provided automated metabolite-identification error estimates, addressing a recognized need for statistical confidence measures in metabolomics.

Petzold, Christopher [Lawrence Berkeley National L↗