Search NASA⌕ Search

SEARCH · Search NASA

Results for “column”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Design Through Simulation of a Molecular Sieve Column for Treatment of MON-3

The presence of water in propellant-grade MON-3 is a concern in the Aerospace Industry. NASA Johnson Space Center (JSC), White Sands Test Facility (WSTF) Propulsion Department has evaluated many types of molecular sieves for control of iron, the corrosion product of water in Mixed Oxides of Nitrogen (MON-3). In 1995, WSTF initiated laboratory and pilot-scale testing of molecular sieve type 3A for removal of water and iron. These tests showed sufficient promise that a series of continuous recycle tests were conducted at WSTF. Periodic samples of the circulating MON-3 solution were analyzed for water (wt %) and iron (ppm, wt). This test column was modeled as a series of transfer units; i. e., each unit represented the height equivalent of a theoretical plate. Such a model assumes there is equilibrium between the adsorbent material and the effluent stream from the unit. Operational and design parameters were derived based on the simulation results. These parameters were used to predict the design characteristics of a proposed molecular sieve column for removal of water and iron from MON-3 at the NASA Kennedy Space Center (KSC). In addition, these parameters were used to simulate a small, single-pass operation column at KSC currently used for treating MON-3. The results of this work indicated that molecular sieve type 3A in 1/16 in. diameter pellets, in a column 2.5 ft. in diameter, 18 ft. in height, and operated at 25 gpm is adequate for the required removal of water and iron from MON-3.

Swartz, A. Ben↗

Aerosol Effects on Radiation and Climate: Column Closure Experiments with Towers, Aircraft, and Satellites

Many theoretical studies have shown that anthropogenic aerosol particles can change the radiation balance in an atmospheric column and might thereby exert a significant effect on the Earth's climate. In particular, recent calculations have shown that sulfate particles from anthropogenic combustion may already exert a cooling influence on the Earth that partially offsets the warming caused by the greenhouse gases from the same combustion. Despite the potential climatic importance of anthropogenic aerosols, simultaneous measurements of anthropogenic aerosol properties and their effect on atmospheric radiation have been very rare. Successful comparisons of measured radiation fields with those calculated from aerosol measurements - now referred to as column closure comparisons - are required to improve the accuracy and credibility of climate predictions. This paper reviews the column closure experiment performed at the Mt. Sutro Tower in San Francisco in 1975, in which elevated radiometers measured the change in Earth-plus-atmosphere albedo caused by an aerosol layer, while a lidar, sunphotometer, nephelometer, and other radiometers measured properties of the responsible aerosol. The time-dependent albedo calculated from the measured aerosol properties agreed with that measured by the tower radiometers. Also presented are designs for future column closure studies using radiometers and aerosol instruments on the ground, aircraft, and satellites. These designs draw upon algorithms and experience developed in the Sutro Tower study, as well as more recent experience with current measurement and analysis capabilities.

Russell, Philip B.↗

Mars Ozone Absorption Line Shapes from Infrared Heterodyne Spectra Applied to GCM-Predicted Ozone Profiles and to MEX/SPICAM Column Retrievals

We present the application of infrared heterodyne line shapes of ozone on Mars to those produced by radiative transfer modeling of ozone profiles predicted by general circulation models (GCM), and to contemporaneous column abundances measured by Mars Express SPICAM. Ozone is an important tracer of photochemistry Mars' atmosphere, serving as an observable with which to test predictions of photochemistry-coupled GCMs. Infrared heterodyne spectroscopy at 9.5 microns with spectral resolving power >1,000,000 is the only technique that can directly measure fully-resolved line shapes of Martian ozone features from the surface of the Earth. Measurements were made with Goddard Space Flight Center's Heterodyne instrument for Planetary Wind And Composition (HIPWAC) at the NASA Infrared Telescope Facility (IRTF) on Mauna Kea, Hawaii on February 21-24 2008 UT at Ls=35deg on or near the MEX orbital path. The HIPWAC observations were used to test GCM predictions. For example, a GCM-generated ozone profile for 60degN 112degW was scaled so that a radiative transfer calculation of its absorption line shape matched an observed HIPWAC absorption feature at the same areographic position, local time, and season. The RMS deviation of the model from the data was slightly smaller for the GCM-generated profile than for a line shape produced by a constant-with-height profile, even though the total column abundances were the same, showing potential for testing and constraining GCM ozone-profiles. The resulting ozone column abundance from matching the model to the HIPWAC line shape was 60% higher than that observed by SPICAM at the same areographic position one day earlier and 2.5 hours earlier in local time. This could be due to day-to-day, diurnal, or north polar region variability, or to measurement sensitivity to the ozone column and its distribution, and these possibilities will be explored. This work was supported by NASA's Planetary Astronomy Program.

Fast, Kelly E.↗

Miniaturized Laser Heterodyne Radiometer (LHR) for Measurements of Greenhouse Gases in the Atmospheric Column

This passive laser heterodyne radiometer (LHR) instrument simultaneously measures multiple trace gases in the atmospheric column including carbon dioxide (CO2) and methane (CH4), and resolves their concentrations at different altitudes. This instrument has been designed to operate in tandem with the passive aerosol sensor currently used in AERONET (an established network of more than 450 ground aerosol monitoring instruments worldwide). Because aerosols induce a radiative effect that influences terrestrial carbon exchange, simultaneous detection of aerosols with these key carbon cycle gases offers a uniquely comprehensive measurement approach. Laser heterodyne radiometry is a technique for detecting weak signals that was adapted from radio receiver technology. In a radio receiver, a weak input signal from a radio antenna is mixed with a stronger local oscillator signal. The mixed signal (beat note, or intermediate frequency) has a frequency equal to the difference between the input signal and the local oscillator. The intermediate frequency is amplified and sent to a detector that extracts the audio from the signal. In the LHR instrument described here, sunlight that has undergone absorption by the trace gas is mixed with laser light at a frequency matched to a trace gas absorption feature in the infrared (IR). Mixing results in a beat signal in the RF (radio frequency) region that can be related to the atmospheric concentration. For a one-second integration, the estimated column sensitivities are 0.1 ppmv for CO2, and <1 ppbv for CH4. In addition to producing a standalone ground measurement product, this instrument could be used to calibrate/validate four Earth observing missions: ASCENDS (Active Sensing of CO2 Emissions over Nights, Days, and Seasons), OCO-2 (Orbiting Carbon Observatory), OCO-3, and GOSAT (Greenhouse gases Observational SATellite). The only network that currently measures CO2 and CH4 in the atmospheric column is TCCON (Total Carbon Column Observing Network), and only two of its 16 operational sites are in the United States. TCCON data is used for validation of GOSAT data, and will be used for OCO-2 validation. While these Fourier-transform spectrometers (FTS) can measure the largest range of trace gases, the network is severely limited due to the high cost and extreme size of these instruments (these occupy small buildings and require personnel for operation). The LHR/AERONET instrument offers a significantly smaller (carry-on luggage size) autonomous instrument that can be incorporated into AERONET s much larger (450 instruments) global network.

Steel, Emily↗

A Miniaturized Laser Heterodyne Radiometer for a Global Ground-Based Column Carbon Monitoring Network

We present progress in the development of a passive, miniaturized Laser Heterodyne Radiometer (mini-LHR) that will measure key greenhouse gases (C02, CH4, CO) in the atmospheric column as well as their respective altitude profiles, and O2 for a measure of atmospheric pressure. Laser heterodyne radiometry is a spectroscopic method that borrows from radio receiver technology. In this technique, a weak incoming signal containing information of interest is mixed with a stronger signal (local oscillator) at a nearby frequency. In this case, the weak signal is sunlight that has undergone absorption by a trace gas of interest and the local oscillator is a distributive feedback (DFB) laser that is tuned to a wavelength near the absorption feature of the trace gas. Mixing the sunlight with the laser light, in a fast photoreceiver, results in a beat signal in the RF. The amplitude of the beat signal tracks the concentration of the trace gas in the atmospheric column. The mini-LHR operates in tandem with AERONET, a global network of more than 450 aerosol sensing instruments. This partnership simplifies the instrument design and provides an established global network into which the mini-LHR can rapidly expand. This network offers coverage in key arctic regions (not covered by OCO-2) where accelerated warming due to the release of CO2 and CH4 from thawing tundra and permafrost is a concern as well as an uninterrupted data record that will both bridge gaps in data sets and offer validation for key flight missions such as OCO-2, OCO-3, and ASCENDS. Currently, the only ground global network that routinely measures multiple greenhouse gases in the atmospheric column is TCCON (Total Column Carbon Observing Network) with 18 operational sites worldwide and two in the US. Cost and size of TCCON installations will limit the potential for expansion, We offer a low-cost $30Klunit) solution to supplement these measurements with the added benefit of an established aerosol optical depth measurement. Aerosols induce a radiative effect that is an important modulator of regional carbon cycles. Changes in the diffuse radiative flux fraction (DRF) due to aerosol loading have the potential to alter the terrestrial carbon exchange.

Wilson, Emily L.↗

Airborne 2-Micron Double-Pulsed Integrated Path Differential Absorption Lidar for Column CO2 Measurement

Double-pulse 2-micron lasers have been demonstrated with energy as high as 600 millijouls and up to 10 Hz repetition rate. The two laser pulses are separated by 200 microseconds and can be tuned and locked separately. Applying double-pulse laser in DIAL system enhances the CO2 measurement capability by increasing the overlap of the sampled volume between the on-line and off-line. To avoid detection complicity, integrated path differential absorption (IPDA) lidar provides higher signal-to-noise ratio measurement compared to conventional range-resolved DIAL. Rather than weak atmospheric scattering returns, IPDA rely on the much stronger hard target returns that is best suited for airborne platforms. In addition, the IPDA technique measures the total integrated column content from the instrument to the hard target but with weighting that can be tuned by the transmitter. Therefore, the transmitter could be tuned to weight the column measurement to the surface for optimum CO2 interaction studies or up to the free troposphere for optimum transport studies. Currently, NASA LaRC is developing and integrating a double-Pulsed 2-micron direct detection IPDA lidar for CO2 column measurement from an airborne platform. The presentation will describe the development of the 2-micron IPDA lidar system and present the airborne measurement of column CO2 and will compare to in-situ measurement for various ground target of different reflectivity.

Singh, Upendra N.↗

Airborne Measurements of CO2 Column Concentration and Range Using a Pulsed Direct-Detection IPDA Lidar

We have previously demonstrated a pulsed direct detection IPDA lidar to measure range and the column concentration of atmospheric CO2. The lidar measures the atmospheric backscatter profiles and samples the shape of the 1,572.33 nm CO2 absorption line. We participated in the ASCENDS science flights on the NASA DC-8 aircraft during August 2011 and report here lidar measurements made on four flights over a variety of surface and cloud conditions near the US. These included over a stratus cloud deck over the Pacific Ocean, to a dry lake bed surrounded by mountains in Nevada, to a desert area with a coal-fired power plant, and from the Rocky Mountains to Iowa, with segments with both cumulus and cirrus clouds. Most flights were to altitudes >12 km and had 5-6 altitude steps. Analyses show the retrievals of lidar range, CO2 column absorption, and CO2 mixing ratio worked well when measuring over topography with rapidly changing height and reflectivity, through thin clouds, between cumulus clouds, and to stratus cloud tops. The retrievals shows the decrease in column CO2 due to growing vegetation when flying over Iowa cropland as well as a sudden increase in CO2 concentration near a coal-fired power plant. For regions where the CO2 concentration was relatively constant, the measured CO2 absorption lineshape (averaged for 50 s) matched the predicted shapes to better than 1% RMS error. For 10 s averaging, the scatter in the retrievals was typically 2-3 ppm and was limited by the received signal photon count. Retrievals were made using atmospheric parameters from both an atmospheric model and from in situ temperature and pressure from the aircraft. The retrievals had no free parameters and did not use empirical adjustments, and >70% of the measurements passed screening and were used in analysis. The differences between the lidar-measured retrievals and in situ measured average CO2 column concentrations were <1.4 ppm for flight measurement altitudes >6 km.

Lidar↗

Modeling a Miniaturized Scanning Electron Microscope Focusing Column - Lessons Learned in Electron Optics Simulation

This presentation discusses work done to assess the design of a focusing column in a miniaturized Scanning Electron Microscope (SEM) developed at the NASA Marshall Space Flight Center (MSFC) for use in-situ on the Moon-in particular for mineralogical analysis. The MSFC beam column design uses purely electrostatic fields for focusing, because of the severe constraints on mass and electrical power consumption imposed by the goals of lunar exploration and of spaceflight in general. The resolution of an SEM ultimately depends on the size of the focused spot of the scanning beam probe, for which the stated goal here is a diameter of 10 nanometers. Optical aberrations are the main challenge to this performance goal, because they blur the ideal geometrical optical image of the electron source, effectively widening the ideal spot size of the beam probe. In the present work the optical aberrations of the mini SEM focusing column were assessed using direct tracing of non-paraxial rays, as opposed to mathematical estimates of aberrations based on paraxial ray-traces. The geometrical ray-tracing employed here is completely analogous to ray-tracing as conventionally understood in the realm of photon optics, with the major difference being that in electron optics the lens is simply a smoothly varying electric field in vacuum, formed by precisely machined electrodes. Ray-tracing in this context, therefore, relies upon a model of the electrostatic field inside the focusing column to provide the mathematical description of the "lens" being traced. This work relied fundamentally on the boundary element method (BEM) for this electric field model. In carrying out this research the authors discovered that higher accuracy in the field model was essential if aberrations were to be reliably assessed using direct ray-tracing. This led to some work in testing alternative techniques for modeling the electrostatic field. Ultimately, the necessary accuracy was attained using a BEM/Fourier series hybrid approach. The presentation will give background remarks about the MSFC mini Lunar SEM concept and electron optics modeling, followed by a description of the alternate field modeling techniques that were tried, along with their incorporation into a ray-trace simulation. Next, the validation of this simulation against commercially available software will be discussed using an example lens as a test case. Then, the efficacy of aberration assessment using direct ray-tracing will be demonstrated, using this same validation case. The discussion will include practical error checks of the field solution. Finally, the ray-trace assessment of the MSFC mini Lunar SEM concept will be shown and discussed. The authors believe this presentation will be of general interest to practitioners of modeling and simulation, as well as those with a general optics background. Because electron optics and photon optics share many basic concepts (e.g., lenses, images, aberrations, etc.), the appeal of this presentation need not be restricted to just those interested in charged particle optics.

Modeling Miniaturizing Scanning↗

Seasonal Clear-Sky Flux and Cloud Radiative Effect Anomalies in the Arctic Atmospheric Column Associated with the Arctic Oscillation and Arctic Dipole

The impact of the Arctic Oscillation (AO) and Arctic Dipole (AD) on the radiative flux into the Arctic mean atmospheric column is quantified. 3-month-averaged AO and AD indices are regressed with corresponding surface and top-of-atmosphere (TOA) fluxes from the CERES-SFC and CERES-TOA EBAF datasets over the period 2000-2014. An increase in clear-sky fluxes into the Arctic mean atmospheric column during fall is the largest net flux anomaly associated with AO, primarily driven by a positive net longwave flux anomaly (i.e. increase of net flux into the atmospheric column) at the surface. A decrease in the Arctic mean atmospheric column cloud radiative effect during winter and spring is the largest flux anomaly associated with AD, primarily driven by a change in the longwave cloud radiative effect at the surface. These prominent responses to AO and AD are widely distributed across the ice-covered Arctic, suggesting that the physical process or processes that bring about the flux change associated with AO and AD are distributed throughout the Arctic.

Hegyi, Bradley M.↗

Measurement of Atmospheric CO2 Column Concentrations to Cloud Tops With a Pulsed Multi-Wavelength Airborne Lidar

We have measured the column-averaged atmospheric CO2 mixing ratio to a variety of cloud tops by using an airborne pulsed multi-wavelength integrated-path differential absorption (IPDA) lidar. Airborne measurements were made at altitudes up to 13 km during the 2011, 2013 and 2014 NASA Active Sensing of CO2 Emissions over Nights, Days, and Seasons (ASCENDS) science campaigns flown in the United States West and Midwest and were compared to those from an in situ sensor. Analysis of the lidar backscatter profiles shows the average cloud top reflectance was approx. 5% for the CO2 measurement at 1572.335 nm except to cirrus clouds, which had lower reflectance. The energies for 1 micro-s wide laser pulses reflected from cloud tops were sufficient to allow clear identification of CO2 absorption line shape and then to allow retrievals of atmospheric column CO2 from the aircraft to cloud tops more than 90% of the time. Retrievals from the CO2 measurements to cloud tops had minimal bias but larger standard deviations when compared to those made to the ground, depending on cloud top roughness and reflectance. The measurements show this new capability helps resolve CO2 horizontal and vertical gradients in the atmosphere. When used with nearby full-column measurements to ground, the CO2 measurements to cloud tops can be used to estimate the partial-column CO2 concentration below clouds, which should lead to better estimates of surface carbon sources and sinks. This additional capability of the range-resolved CO2 IPDA lidar technique provides a new benefit for studying the carbon cycle in future airborne and space-based CO2 missions.

atmospheric↗

Investigation of Transient Gas Phase Column Density Due to Droplet Evaporation

A NASA robotic refueling mission experiment on board the International Space Station (ISS) was designed to repeatedly transfer simulated cryogenic propellant between two dewars. After each metered transfer, the cryogen was to be vented overboard via sublimation or evaporation. ISS payload providers must conduct analyses to demonstrate that any planned gaseous venting generate no more than a certain level of material that may interfere with optical measurements from other payloads that may be located nearby. This requirement is expressed in terms of a maximum column number density (CND). For the experiment under consideration, fluid droplets likely would accompany any such vapor. Earlier related studies led to development of analytical expressions for column density along general paths for a number of practical cases under steady conditions, including droplet evaporation. These expressions are not appropriate for rapid evaporation of small droplets however, since the droplets cannot sustain mass flow rates consistent with steady conditions. In this work, analytical expressions are developed for estimating column density near a rapidly evaporating droplet along general paths. The influence for instantaneous evaporation is created first as a limiting case, where it is found the peak value occurs at the time it takes a wave of vapor to reach the closest point along the optical path traveling at its most probable thermal speed. Next, the case for finite-period evaporation is evaluated for constant conditions. Compared to the instantaneous case, peak column density occurs shortly after droplet extinction, but at a lower intensity. A new mathematical function is discovered that solves the integrals associated with this case. Finally, ways to account for droplet motion and changes in evaporation rate with size and temperature are discussed in this framework.

Woronowicz, M. S.↗

Evaluation of the Stratospheric and Tropospheric Bromine Burden over Fairbanks, Alaska Based on Column Retrievals of Bromine Monoxide

In spring 2011, columns of bromine monoxide (BrO) were retrieved over Fairbanks, Alaska using a ground-based multifunction differential optical absorption spectroscopy (MFDOAS) instrument. MFDOAS vertical column BrO is consistently lower than retrievals from the satellite-based Ozone Monitoring Instrument (OMI), with a relative bias of 20 ± 14%. Numerous tropical-based studies suggest that 5 ± 2 ppt of bromine from very short-lived substances (VSLS) reaches the stratosphere. We evaluate upper limits on the contribution of VSLS to stratospheric bromine by treating the column retrievals of BrO as purely stratospheric and modeling the ratio of BrO to total inorganic bromine. The OMI and MFDOAS retrievals respectively present 8 and 5 ppt upper limits on the stratospheric injection of VSLS, and kinetic uncertainties in the daytime partitioning of bromine species decrease both values by ~1.6 ppt. The OMI-based estimate is in agreement with the 5 ppt tropical-based value for stratospheric injection of VSLS if the tropospheric column of BrO is 1.5 × 10(exp 13) molecules/cu. cm over Fairbanks, which is within the range of uncertainty of a second ground-based instrument that monitored tropospheric BrO during the campaign. Because our ground-based instruments detected no BrO near the surface, this value for tropospheric BrO would originate from the free troposphere and is in agreement with previous retrievals of background tropospheric BrO. Our calculations of tropospheric BrO over Fairbanks are most sensitive to uncertainties in the stratospheric loading of VSLS, followed by the difference between the OMI and MFDOAS retrievals of BrO.

Pamela A. Wales↗

Ground-based retrievals of aerosol column absorption in the UV spectral region and their implications for GEMS measurements

Quantifying the spectral variation of column aerosol absorption in the ultraviolet (UV) and visible (Vis) wavelengths is required for accurate satellite-based aerosol and trace-gas retrievals. Retrievals of the column-averaged imaginary part of refractive index and single scattering albedo (SSA) in the UV–Vis range have been performed at Yonsei University, Seoul, Korea, since 2016 by combining co-located measurements from the NASA Aerosol Robotic Network (AERONET) Cimel sun-sky photometer, the Ultraviolet Multifilter Rotating Shadowband Radiometer (UV-MFRSR), the SKYNET Prede sky radiometer, and the NASA Pandora sun spectrometer. We investigated the spectral variation of column-averaged imaginary part of refractive index for UV–Vis wavelengths to refine models used in our aerosol retrieval algorithm to process measurements from the upcoming Geostationary Environment Monitoring Satellite (GEMS). The retrieved imaginary part of refractive index for highly absorbing fine pollution particles (BC), dust (DS), and non-absorbing (NA) particles in the selected UV–Vis range (380–440 nm) showed 0–20%, 30%, and 0–40% of spectral dependence, respectively. Retrievals of Ozone Monitoring Instrument (OMI) measurement data using the improved aerosol model showed improved correlation with AERONET data compared to the old algorithm that did not properly account for aerosol absorption effects. These results corroborate the advantage of using local climatology derived from ground-based UV–Vis spectral aerosol absorption measurements for satellite GEMS aerosol retrievals over East Asia. Moreover, this study reveals that spectral variations in the UV column aerosol absorption in East Asia differ from those in other regions.

ultraviolet (UV) and visible (Vis) wavelengths↗

Formaldehyde Column Density as an Indicator for Elevated Surface Ozone

Efforts to observe near-surface ozone directly from space are hindered by the limited sensitivity of ozone satellite retrievals to the lower troposphere. Formaldehyde (HCHO) column observations from the NASA DISCOVER-AQ campaign showed a strong relationship with surface ozone, particularly when biogenic volatile organic compounds (VOCs) were the dominant ozone precursor due to their strong temperature-driven variability. Both tropospheric ozone and HCHO are secondarily produced through the oxidation of VOCs and in regions where the main fate of RO2 is reaction with NO, thus formaldehyde and ozone are generally co-produced. This work explores the relationship between column formaldehyde and surface ozone using data from two air quality research campaigns, the Long Island Sound Tropospheric Ozone Study (LISTOS) in 2018 and the Korea U.S. - Air Quality (KORUS-AQ) campaign in 2016. These campaigns included HCHO column information from airborne in-situ profiling and remote sensing and ground-based Pandora spectrometers in combination with surface ozone monitors in each region. These data are used to further explore the HCHO-ozone relationship and its potential for identifying areas of elevated ozone using remote sensing or satellite observations of column HCHO alone. These two regions offer a valuable comparison given their different VOC mixtures and the higher NOx levels in Seoul that result in ozone titration effects. This work will also address the potential for this application with future geostationary satellite observations.

Laura Margaret Judd↗

Small-Column Ion Exchange Testing of Spherical Resorcinol-Formaldehyde

Ion exchange using the Spherical Resorcinol-Formaldehyde (SRF) resin has been selected by the U.S. Department of Energy’s Office of River Protection (DOE-ORP) for use in the Pretreatment Facility (PTF) of the Hanford Tank Waste Treatment and Immobilization Plant (WTP) and for potential application in an at-tank deployment. Numerous studies have shown the SRF resin to be effective for removing Cs-137 from a wide variety of actual and simulated tank waste supernatants. Prior work focused primarily on the loading behavior for 5 M sodium (Na) solutions at 25°C and the eluting behavior of the loaded SRF resin with virgin 0.5 M HNO3. Recent proposed changes to the process baseline indicate that loading may include a broader range of sodium molarities (2 to 8 M) and higher temperatures (50°C) to alleviate post-filtration precipitation issues. In addition, elution will likely utilize variable-strength recycled nitric acid containing trace amounts of Cs-137. Cesium ion exchange loading and elution curves were generated for a 5 M Na, 2.4E-05 M Cs loading solution traced with Cs-134 followed by elution with variable HNO3 (0.02, 0.07, 0.15, 0.23, and 0.28 M) containing variable CsNO3 (5.0E-09, 5.0E-08, and 5.0E-07 M) and traced with Cs-137. The ion exchange system consisted of a pump, tubing, process solutions, and a single, small (~15 mL) bed of SRF resin with a water-jacketed column for temperature-control. The columns were loaded with approximately 250 bed volumes (BVs) of feed solution at 45°C and at 1.5 to 12 BV per hour (0.15 to 1.2 cm/min). The columns were then eluted with approximately 25 BVs of HNO3 processed at 25°C and at 1.4 BV/hr. The two independent tracers allowed analysis of the on-column cesium interaction between the loading and elution solutions. The objective of these tests was to improve the correlation between the spent resin cesium content and cesium leached out of the resin in subsequent loading cycles (cesium bleed), to help establish acid strength and purity requirements.

Brown, Garrett N.↗

Space Charge Compensation Using Electron Columns and Electron Lenses at IOTA

The ability to transport a high current proton beam in a ring is ultimately limited by space charge effects. Two novel ways to overcome this limit in a proton ring are by adding low energy, externally matched electron beams (electron lens, e-lens), and by taking advantage of residual gas ionization induced neutralization to create an electron column (e-column). Theory predicts that an appropriately confined electrons can completely compensate the space charge through neutralization, both transversely and longitudinally. In this report, we will discuss the current status of the Fermilab’s e-lens experiment for the space charge compensation. In addition, we will show how the IOTA e-column compensates space charge with theWARP simulations. The dynamics of proton beams inside of the e-column is understood by changing the magnetic field of a solenoid, the voltage on the electrodes, and the vacuum pressure, and by looking for electron accumulation, as well as by considering various beam dynamics in the IOTA ring.

43 PARTICLE ACCELERATORS↗

Full-Column Greenhouse Gas Sampling Field Campaign Report

The AirCore is a balloon-borne sampler patented and developed at the National Oceanic and Atmospheric Administration (NOAA) Earth System Research Laboratory (ESRL) Global Monitoring Division (GMD) (Tans 2009) that has the capability to provide full-column measurements of greenhouse gases and other trace gas species (Karion et al. 2010). It consists of a long, coated stainless steel tube that is filled with a known trace gas mixture prior to balloon launch (Figure 1). The AirCore is opened at one end prior to balloon launch and, as the balloon ascends, it evacuates to ambient pressure. At 30 km, the balloon is cut away and the AirCore descends via parachute, now capturing an atmospheric air sample or “core” of air from 30 km to the surface due to the pressure gradient between the evacuated AirCore and the environment. Upon landing, the AirCore is closed, preserving the air sample collected in-flight. Because diffusion acts slowly on the AirCore sample in the four hours that it typically takes to launch, retrieve, and analyze the sample, it is possible to capture more than 100 discrete samples in the atmospheric profile collected by the AirCore. Currently, the AirCore is analyzed for carbon dioxide (CO2), methane (CH4), and carbon monoxide (CO) at NOAA/ESRL GMD, but the sample collected can be measured on a variety of other analyzers to obtain full-column profiles of other trace gas species. Unlike routine aircraft measurements, the AirCore provides a low-cost alternative to atmospheric profiling and captures >95% of the atmospheric column. It has a variety of applications, including to full-column greenhouse and trace gas sampling and monitoring, to satellite and remote-sensing instrumentation evaluation, and to tropospheric and stratospheric model evaluation.

Greenhouse gases, Southern Great Plains, balloon-b↗

Simulation of In Situ Bioremediation of Chromium (VI) Using Consortium Cultures and Column Studies - 19357

Chromium contaminated soil and ground water has become a serious problem caused by the rapid expansion of industries, leading to direct or indirect discharge of Cr(VI). The conventional methods that include pump and treat result into toxic byproducts and residual. Cr(VI) reducing bacteria in the contrary have been envisioned as an economically and ecologically friendly method to treat contaminated sites. Biological Cr(VI) reduction processes include biotransformation, biosorption which involve detoxification/ removal of hazardous substances and bioaccumulation. A continuous flow column system for Cr(VI) reduction was investigated in three different treatments and the control, using dried sludge and soil from target site. Cultures identified using effluent samples in the 16S rRNA sequencing showed a prominent of Exiguobacterium aestuarii species as it was identified from all column systems. Other cultures that showed 100% query cover included; Enterobacter aerogenes, Enterobacter kobei and Pseudomonas aeruginosa. More than 90% of Cr(VI) reduction was observed in all columns over a 60 day period at 40 mgL{sup -1}. Cr(VI) was reduced from 38.12 mgL{sup -1} to 0.39 mgL{sup -1}. A more unstable profile was observed at 60 mgL{sup -1} over 60 days. Subsequently, there was near complete reduction from System 1 and 3 of 1.152 mgL{sup -1} and 1.215 mgL{sup -1} Cr(VI) concentration, respectively. A Cr(VI) reduction profile along the column proved to be uniform at assumed quasi-steady state from the influent to the effluent for both 40 and 60 mgL{sup -1} Cr(VI) concentration. Biological remediation strategies for Cr(VI) contaminated soil and groundwater is an emerging field that has been proposed to successfully treat Cr(VI) contaminated sites using Cr(VI) reduction species of bacteria. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗