At least 253 records · Page 14

Garvin-King Well - Ohio

CT Data that compliments the Technical Report Series Document: Pohl, M.; Paronish, T.; Mitchell, N.; Jarvis, K.; Sharma, M.; Moore, J.; Crandall, D.; Danielsen, E. M.; McDonald, J. Computed Tomography Scanning and Petrophysical Measurements of Oriskany Cores Across Eastern Ohio, US Department of Energy, National Energy Technology Laboratory: Morgantown, WV, 2024

Computed Tomography↗

NY Central System 1 Well - Ohio

CT Data that compliments the Technical Report Series document: Pohl, M.; Paronish, T.; Mitchell, N.; Jarvis, K.; Sharma, M.; Moore, J.; Crandall, D.; Danielsen, E. M.; McDonald, J. Computed Tomography Scanning and Petrophysical Measurements of Oriskany Core Across Eastern Ohio, U.S. Department of Energy, National Energy Technology Laboratory: Morgantown, WV, 2024

Computed Tomography↗

Thermal Inspection for the Assessment of Adhesively Bonded Metal Adherends

Certification of adhesively bonded structures is currently a challenge for aircraft manufacturers. The ability to certify bonds in primary structure can reduce dependence on fasteners and this will enable more efficient manufacturing. For example, drilling holes and installing fasteners in bonded joints can be a potentially significant bottleneck in airframe manufacturing. In addition, fasteners increase the airframe weight and can add stress concentration areas. Reducing fastener count can accelerate manufacturing and improve aircraft performance. NASA is currently investigating nondestructive evaluation (NDE) techniques to assess bond integrity. For example, bond thickness influences bond strength and therefore NDE techniques are being investigated to determine bond thickness. For bonded metal structures, there is a large difference in the thermal diffusivity between the 7075 aluminum alloy metal adherends and aircraft grade adhesive. Multi-layered thermal models show a large variation in the thermal response for bondline adhesive thicknesses that vary from 100 to 300 microns for adherend thicknesses of 0.163 cm. Experimental through-transmission thermal measurements reveal promise to quantitatively characterize the bondline thickness. Results were validated with X-ray computed tomography and optical microscopy measurements, and influence of porosity on the thermal model and measurements are investigated.

X-ray computed tomography↗

Survey of Deep Learning and Physics-Based Approaches in Computational Wave Imaging

Computational wave imaging (CWI) extracts hidden structure and physical properties of a volume of material by analyzing wave signals that traverse that volume. Applications include seismic exploration of the Earth’s subsurface, acoustic imaging and nondestructive testing (NDT) in material science, and ultrasound computed tomography (USCT) in medicine. Current approaches for solving CWI problems can be divided into two categories: those rooted in traditional physics and those based on deep learning. Physics-based methods stand out for their ability to provide high-resolution and quantitatively accurate estimates of acoustic properties within the medium. However, they can be computationally intensive and are susceptible to ill-posedness and nonconvexity typical of CWI problems. Machine learning (ML)-based computational methods have recently emerged, offering a different perspective to address these challenges. Diverse scientific communities have independently pursued the integration of deep learning in CWI. This review discusses how contemporary scientific ML techniques, and deep neural networks in particular, have been developed to enhance and integrate with traditional physics-based methods for solving CWI problems. We present a structured framework that consolidates existing research spanning multiple domains, including computational imaging, wave physics, and data science. This study concludes with important lessons learned from existing ML-based methods and identifies technical hurdles and emerging trends through a systematic analysis of the extensive literature on this topic.

42 ENGINEERING↗

Baroreflex regulation of blood pressure during dynamic exercise

From the work of Potts et al. Papelier et al. and Shi et al. it is readily apparent that the arterial (aortic and carotid) baroreflexes are reset to function at the prevailing ABP of exercise. The blood pressure of exercise is the result of the hemodynamic (cardiac output and TPR) responses, which appear to be regulated by two redundant neural control systems, "Central Command" and the "exercise pressor reflex". Central Command is a feed-forward neural control system that operates in parallel with the neural regulation of the locomotor system and appears to establish the hemodynamic response to exercise. Within the central nervous system it appears that the HLR may be the operational site for Central Command. Specific neural sites within the HLR have been demonstrated in animals to be active during exercise. With the advent of positron emission tomography (PET) and single-photon emission computed tomography (SPECT), the anatomical areas of the human brain related to Central Command are being mapped. It also appears that the Nucleus Tractus Solitarius and the ventrolateral medulla may serve as an integrating site as they receive neural information from the working muscles via the group III/IV muscle afferents as well as from higher brain centers. This anatomical site within the CNS is now the focus of many investigations in which arterial baroreflex function, Central Command and the "exercise pressor reflex" appear to demonstrate inhibitory or facilitatory interaction. The concept of whether Central Command is the prime mover in the resetting of the arterial baroreceptors to function at the exercising ABP or whether the resetting is an integration of the "exercise pressor reflex" information with that of Central Command is now under intense investigation. However, it would be justified to conclude, from the data of Bevegard and Shepherd, Dicarlo and Bishop, Potts et al., and Papelier et al. that the act of exercise results in the resetting of the arterial baroreflex. In addition, if, as we have proposed, the cardiopulmonary baroreceptors primarily monitors and reflexly regulates cardiac filling volume, it would seem from the data of Mack et al. and Potts et al. that the cardiopulmonary baroreceptor is also reset at the beginning of exercise. Therefore, investigations of the neural mechanisms of regulation involving Central Command and cardiopulmonary afferents, similar to those being undertaken for the arterial baroreflex, need to be established.

NASA Discipline Cardiopulmonary↗

Thermal Inspection for the Assessment of Adhesively Bonded Metal Adherents

Certification of adhesively bonded structures is currently a challenge for aircraft manufacturers. The ability to certify bonds in primary structure can reduce dependence on fasteners and this will enable more efficient manufacturing. For example, drilling holes and installing fasteners in bonded joints can be a potentially significant bottleneck in airframe manufacturing. In addition, fasteners increase the airframe weight and can add stress concentration areas. Reducing fastener count can accelerate manufacturing and improve aircraft performance. NASA is currently investigating nondestructive evaluation (NDE) techniques to assess bond integrity. For example, bond thickness influences bond strength and therefore NDE techniques are being investigated to determine bond thickness. For bonded metal structures, there is a large difference in the thermal diffusivity between the 7075 aluminum alloy metal adherends and aircraft grade adhesive. Multi-layered thermal models show a large variation in the thermal response for bondline adhesive thicknesses that vary from 100 to 300 microns for adherend thicknesses of 0.163 cm. Experimental through-transmission thermal measurements reveal promise to quantitatively characterize the bondline thickness. Results were validated with X-ray computed tomography and optical microscopy measurements, and influence of porosity on the thermal model and measurements are investigated.

bondline thickness↗

Closed-Form Approximation of the Total Variation Proximal Operator

Total variation (TV) is a widely used function for regularizing imaging inverse problems that is particularly appropriate for images whose underlying structure is piecewise constant. TV regularized optimization problems are typically solved using proximal methods, but the way in which they are applied is constrained by the absence of a closed-form expression for the proximal operator of the TV function. A closed-form approximation of the TV proximal operator has previously been proposed, but its accuracy was not theoretically explored in detail. Here, we address this gap by making several new theoretical contributions, proving that the approximation leads to a proximal operator of some convex function, it is equivalent to a gradient descent step on a smoothed version of TV, and that its error can be fully characterized and controlled with its scaling parameter. We experimentally validate our theoretical results on image denoising and sparse-view computed tomography (CT) image reconstruction.

97 MATHEMATICS AND COMPUTING↗

In-Space Inspection Needs: Opportunities for advanced NDE tools such as x-ray CT for additively manufactured parts, in-situ resource utilization, geological applications, and more

It is now 50 years since the first human presence on the surface of the Moon and as we strive to return with women and men in the next few years, we embrace new technical challenges, goals, and innovative solutions to address 21st century objectives. These new ambitions carry fresh challenges and risks, with the field of NDE playing an increasingly more relevant role towards meeting these essential goals. In recent years, more advanced NDE tools have triggered a rapid expansion of applications for the space industry. In particular, x-ray Computed Tomography (CT) has proven to be a trusted and powerful asset for spaceflight hardware inspection, as well as applied geotechnical analysis for natural materials (e.g., rocks, soils) for NASA and across industry. However, such methods have yet to be extended to “deep space” applications such as those that are now part of the US National Space Policy Directive (SPD-1) and the accelerated push to return humans to the Moon (i.e., Artemis). For this reason, advancing these powerful Earth-based laboratory methods via new technologies, integrated computational solutions, and creative engineering approaches is directly aligned with national space policies, as well as with multiple NASA Strategic Plan priorities. The use of x-ray CT at scales as fine as a few microns or smaller can identify spacecraft part failure modes relevant to quality assurance for flight hardware and AM parts such as those recently developed for ISS. This technology could also identify valuable metallic phases within geological materials (i.e., rocks or drill cores), enabling resource-relevant triage of samples for In-Situ Resource Utilization (ISRU) and high science value sample return to Earth laboratories. There is also significant application for 3D imaging tools for medical use such as inspecting protective gear as well as bone density degradation studies which are critical in establishing a sustained presence in space. Timing for development of these tools for space use is advantageous as we prepare for new opportunities in the next few years and recognize recent commercial technology advancements which make it feasible. Moreover, as NASA strives to take full advantage of developments in AM technologies, including In-Space Manufacturing (ISM), it is widely recognized that NDE tools such as CT will play an essential role in acceptance of these parts for widespread use. New in-space 3D inspection tools with complimentary technology such as AI-based automated feature recognition (accelerated by machine learning), rapid compositional analysis, and advanced sample manipulation, would be a game-changing step toward a new class of crew-based laboratory sensors once human outposts on the Moon are established.

In-Space Non-Destructive Evaluation↗

Mt. Simon Sandstone - High Resolution CT

High resolution micro-computed tomography images of sandstone from the Mt. Simon formation at different depths. These images provide an insight into the pore structure of the Mt. Simon sandstone (e.g. for potential CO2 storage). This data set can be used to further study the formation as a whole..

CCS,CO2 Sequestration,Carbon Sequestration,Compute↗

Spatiotemporally Registered In-Situ and Ex-Situ Datasets for Laser-based Blown Powder Directed Energy Deposition

This dataset is comprised of in situ sensing data collected during laser-based, blown powder directed energy deposition (DED) of Inconel 718 representing eight different printing conditions: (1) nominal, (2) +15% scan speed, (3) +12% laser power, (4) +42% powder feed rate, (5) +100% jerk limit, (6) +10% layer height, (7) +20% hatch spacing, (8) +20% carrier gas flow. All eight DED builds constructed an identical test coupon geometry consisting of geometric features representative of industrial print requirements (e.g., bulk deposition, thin walls, overhangs). In situ data consists of xyz-coordinates (100 Hz) and on-axis melt pool camera video (60 Hz), both of which have been temporally synchronized to spatially map the melt pool camera data. In addition, post-build X-ray computed tomography (XCT) data for each of the eight test geometries have been spatially registered to the recorded xyz-coordinates, allowing for comparisons between melt pool camera data and flaws identified in the XCT data.

additive manufacturing↗

Flash Thermal Diffusivity Measurements and Inspection of Additively Manufactured Ti-6Al-4V Specimens with Varying Process Parameters

Flash thermal diffusivity measurements were obtained on additively manufactured Ti-6Al-4V disk shaped specimens with various process parameters. For additively manufactured metal parts, processing parameters such as laser power and scanning speed are critical to ensure the desired microstructure. For this study, the laser powder bed fusion process parameters were changed at various angular sections on a 21 mm diameter and 3.0 mm thick disk. The measurement of thermal diffusivity was performed by fitting a 1-dimensional thermal model to the data pixel by pixel to produce an inspection image. The image revealed the detection of defects such as lack of fusion porosity and areas of aggregated porosity. The thermal diffusivity imagery was compared to immersion scan ultrasonic and X-ray computed tomography (CT) measurements for validation. Based on these results, additional samples were investigated using a single side thermal inspection technique to detect lack of fusion porosity and near surface voids.

thermal nondestructive evaluation↗

Flash Thermal Diffusivity Measurements and Inspection of Additively Manufactured Ti-6Al-4V Specimens with Varying Process Parameters

Flash thermal diffusivity measurements were obtained on additively manufactured Ti-6Al-4V disk shaped specimens with various process parameters. For additively manufactured metal parts, processing parameters such as laser power and scanning speed are critical to ensure the desired microstructure. For this study, the laser powder bed fusion process parameters were changed at various angular sections on a 21 mm diameter and 3.0 mm thick disk. The measurement of thermal diffusivity was performed by fitting a 1-dimensional thermal model to the data pixel by pixel to produce an inspection image. The image revealed the detection of defects such as lack of fusion porosity and areas of aggregated porosity. The thermal diffusivity imagery was compared to immersion scan ultrasonic and X-ray computed tomography (CT) measurements for validation. Based on these results, additional samples were investigated using a single side thermal inspection technique to detect lack of fusion porosity and near surface voids.

thermal nondestructive evaluation↗

The Effect of Experimental Variables on Industrial X-Ray Micro-Computed Sensitivity

A study was performed on the effect of experimental variables on radiographic sensitivity (image quality) in x-ray micro-computed tomography images for a high density thin wall metallic cylinder containing micro-EDM holes. Image quality was evaluated in terms of signal-to-noise ratio, flaw detectability, and feature sharpness. The variables included: day-to-day reproducibility, current, integration time, voltage, filtering, number of frame averages, number of projection views, beam width, effective object radius, binning, orientation of sample, acquisition angle range (180deg to 360deg), and directional versus transmission tube.

X-ray Computed Tomography↗

Damage progression and failure of SiC/SiC composite tubes under hard-contact radial expansion

The response of silicon carbide (SiC) fiber-reinforced SiC matrix (SiC/SiC) composite cladding to mechanical interaction with fissile fuel is a knowledge gap that must be overcome to design and assess SiC-based cladding systems for advanced nuclear applications. This study developed the relevant mechanical testing capability and identified the failure behavior and the critical microstructural features and processing defects. Sections of SiC composite tube were subjected to a modified expansion-due-to-compression (EDC) test in an X-ray computed tomography microscope: a polyurethane plug pressed surrogate Al 2 O 3 into the inner walls of the SiC/SiC composite tubes to achieve hard contact. A pure EDC test with just a polyurethane plug was also performed as a reference. Through the use of displacement fields, digital volume correlation revealed inhomogeneous deformation fields in the tubes, even for pure EDC, which was related to the inherent defects in the structure. Deep learning–aided segmentation and systematic data analysis revealed that the presence of inhomogeneous deformation applied by the hard contact was exaggerated by the presence of inner surface imperfections left behind from the matrix densification process. In conclusion, the findings provide insights into the applications, highlighting the necessity for improvements in inner surface roughness and the incorporation of localized contacts in pellet–cladding mechanical interaction computational models.

Composites↗

Boron-Based Neutron Scintillator Screen Characterization with X-Rays and Neutrons

Recent work on boron-based neutron scintillator screens suggests these screens can offer superior performance when compared to commonly used screens. Borated neutron scintillator screens perform well in terms of light output (5-6 times greater than a standard Gadox screen) and detection effi-ciency (larger than standard LiF+ZnS screens). However, previously manu-factured boron-based screens have exhibited non-uniform surface coating and a poor mixture between phosphor and converter particles. The objective of this work was to evaluate newly fabricated scintillator screens to deter-mine if enhanced fabrication methods produced a more homogeneous distribution between neutron converter and scintillation phosphor particles. Uniformity of scintillator material deposition was also inspected. This new iteration of screens appeared more uniform than previous generations with the new coating method improving surface chemistry and scintillator material homogeneity. Additionally, a new methodology for screen characterization, involving the correlation of a neutron image taken with a borated scintillator screen to X-ray computed tomography of that same screen, was demonstrated to elucidate a relationship between scintillator screen thickness and relative light output of the screen under neutron exposure. This method suggested that the ideal thickness of scintillator material was ~150 µm to maximize light output of the screen.

36 - MATERIALS SCIENCE↗

Biaxial Braided Flared Cone Structural Analysis

Computed Tomography (CT) is a useful tool for performing structural analysis on polymer based materials due to its high precision and accuracy. CT data was taken of two flared cones made from carbon fiber and fiberglass. One of the flared cones is pictured below. The variation in braid angle throughout the part was measured using Avizo 3D modelling software while the variation in thickness throughout the part was determined using MATLAB. Samples of pictures from the process of each of these analyses are shown below. The overall goal of this analysis was to collect structural data relevant to future testing of the parts.

Computed Tomography↗

Understanding Fracture Aperture and Permeability Evolution due to Carbonate Mineralization Utilizing 3D Printing

Caprock formations are a crucial part of subsurface-engineered systems. Composed largely of shale, caprocks act as natural barriers that prevent the upward migration of fluids, thereby ensuring the containment of stored substances in subsurface formations. Fractures in these formations are potential leakage pathways for stored fluids. Mineral precipitation reactions in these fractures, particularly calcite, can significantly restrict the fluid permeability, reducing leakage potential. However, predictive capabilities of mineral precipitation in fractures and associated permeability evolution are limited due to a lack of fundamental understanding of such reactions in natural samples, complicated by mineral heterogeneity and the complexity of the fracture structure. In this study, 3D-printed fracture samples are used to understand the impact of carbonate mineralization on fracture aperture and permeability evolution. Samples were printed using a digital light processing (DLP) 3D printer and commercial liquid resin. Calcite precipitation was first tested on printed 2D films before conducting plug flow column experiments aimed to understand fracture permeability changes due to mineral precipitation. Contact angle measurement and Fourier transform infrared (FTIR) spectroscopy on printed 2D films show evidence of a substantial amount of surface energy for calcite nucleation and precipitation. Surface topography analysis of printed fractured surfaces reveals comparable values, highlighting the high replicability of the printed samples. During the column experiments, the permeability reduces exponentially due to a decrease in fracture aperture. Reductions in fracture aperture estimated from effluent concentration and 3D X-ray computed tomography (CT) show comparable results. Moreover, 3D X-ray CT images suggest the impact of local flow velocities on precipitation. The insights gained from this research contribute to a deeper understanding of the permeability evolution due to carbonate mineralization in caprock formations.

3D printing↗