Search NASA⌕ Search

SEARCH · Search NASA

Results for “computer systems organization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Acquisition of quantitative physiological data and computerized image reconstruction using a single scan TV system

A single-scan radiography system has been interfaced to a minicomputer, and the combined system has been used with a variety of fluoroscopic systems and image intensifiers available in clinical facilities. The system's response range is analyzed, and several applications are described. These include determination of the gray scale for typical X-ray-fluoroscopic-television chains, measurement of gallstone volume in patients, localization of markers or other small anatomical features, determinations of organ areas and volumes, computer reconstruction of tomographic sections of organs in motion, and computer reconstruction of transverse axial body sections from fluoroscopic images. It is concluded that this type of system combined with a minimum of statistical processing shows excellent capabilities for delineating small changes in differential X-ray attenuation.

Baily, N. A.↗

Design of testbed and emulation tools

The research summarized was concerned with the design of testbed and emulation tools suitable to assist in projecting, with reasonable accuracy, the expected performance of highly concurrent computing systems on large, complete applications. Such testbed and emulation tools are intended for the eventual use of those exploring new concurrent system architectures and organizations, either as users or as designers of such systems. While a range of alternatives was considered, a software based set of hierarchical tools was chosen to provide maximum flexibility, to ease in moving to new computers as technology improves and to take advantage of the inherent reliability and availability of commercially available computing systems.

Lundstrom, S. F.↗

A systems concept of the vestibular organs

A comprehensive model of vestibular organ function is presented. The model is based on an analogy with the inertial guidance systems used in navigation. Three distinct operations are investigated: angular motion sensing, linear motion sensing, and computation. These operations correspond to the semicircular canals, the otoliths, and central processing respectively. It is especially important for both an inertial guidance system and the vestibular organs to distinguish between attitude with respect to the vertical on the one hand, and linear velocity and displacement on the other. The model is applied to various experimental situations and found to be corroborated by them.

Mayne, R.↗

Homogenizing OSG and XSEDE: Providing Access to XSEDE Allocations through OSG Infrastructure

We present a system that allows individual researchers and virtual organizations (VOs) to access allocations on Stampede2 and Bridges through the Open Science Grid (OSG), a national grid infrastructure for running high throughput computing (HTC) tasks. Using this system, VOs and researchers are able to run larger workflows than can be done with OSG resources alone. This system allows a VO or user to run on XSEDE resources (with their allocation) using the same framework used with OSG resources. The system consists of two parts: the compute element (CE) that routes workloads to the appropriate user accounts and allocation on XSEDE resources, and simulated access to the CernVM Filesystem (CVMFS) servers used by OSG and VOs to distribute software and data. This allows jobs submitted through this system to work on a homogeneous environment regardless of whether they run on XSEDE HPC resources (like Stampede2 and Bridges) or OSG.

Thapa, Thapa,Suchandra↗

A Pilot Trial of Serial 18F-Fluorodeoxyglucose Positron Emission Tomography in Patients With Medically Inoperable Stage I Non-Small-Cell Lung Cancer Treated With Hypofractionated Stereotactic Body Radiotherapy

Purpose: Routine assessment was made of tumor metabolic activity as measured by 18F-fluorodeoxyglucose (FDG) positron emission tomography (PET) in Stage I non-small-cell lung cancer (NSCLC). This report describes PET correlates prospectively collected after stereotactic body radiotherapy (SBRT) for patients with medically inoperable NSCLC. Methods and Materials: 14 consecutive patients with medically inoperable Stage I NSCLC were enrolled. All patients received SBRT to 60-66 Gy in three fractions. Patients underwent serial planned FDG-PET/computed tomography fusion imaging before SBRT and at 2, 26, and 52 weeks after SBRT. Results: With median follow-up of 30.2 months, no patients experienced local failure. One patient developed regional failure, 1 developed distant failure, and 1 developed a second primary. The median tumor maximum standardized uptake value (SUV{sub max}) before SBRT was 8.70. The median SUV{sub max} values at 2, 26, and 52 weeks after SBRT were 6.04, 2.80, and 3.58, respectively. Patients with low pre-SBRT SUV were more likely to experience initial 2-week rises in SUV, whereas patients with high pre-SBRT SUV commonly had SUV declines 2 weeks after treatment (p = 0.036). Six of 13 patients had primary tumor SUV{sub max} >3.5 at 12 months after SBRT but remained without evidence of local disease failure on further follow-up. Conclusions: A substantial proportion of patients may have moderately elevated FDG-PET SUV{sub max} at 12 months without evidence of local failure on further follow-up. Thus, slightly elevated PET SUV{sub max} should not be considered a surrogate for local treatment failure. Our data do not support routine serial FDG-PET/computed tomography for follow-up of patients receiving SBRT for Stage I NSCLC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

{sup 18}F-FDG PET-CT Simulation for Non-Small-Cell Lung Cancer: Effect in Patients Already Staged by PET-CT

Purpose: Positron emission tomography (PET), in addition to computed tomography (CT), has an effect in target volume definition for radical radiotherapy (RT) for non-small-cell lung cancer (NSCLC). In previously PET-CT staged patients with NSCLC, we assessed the effect of using an additional planning PET-CT scan for gross tumor volume (GTV) definition. Methods and Materials: A total of 28 patients with Stage IA-IIIB NSCLC were enrolled. All patients had undergone staging PET-CT to ensure suitability for radical RT. Of the 28 patients, 14 received induction chemotherapy. In place of a RT planning CT scan, patients underwent scanning on a PET-CT scanner. In a virtual planning study, four oncologists independently delineated the GTV on the CT scan alone and then on the PET-CT scan. Intraobserver and interobserver variability were assessed using the concordance index (CI), and the results were compared using the Wilcoxon signed ranks test. Results: PET-CT improved the CI between observers when defining the GTV using the PET-CT images compared with using CT alone for matched cases (median CI, 0.57 for CT and 0.64 for PET-CT, p = .032). The median of the mean percentage of volume change from GTV{sub CT} to GTV{sub FUSED} was -5.21% for the induction chemotherapy group and 18.88% for the RT-alone group. Using the Mann-Whitney U test, this was significantly different (p = .001). Conclusion: PET-CT RT planning scan, in addition to a staging PET-CT scan, reduces interobserver variability in GTV definition for NSCLC. The GTV size with PET-CT compared with CT in the RT-alone group increased and was reduced in the induction chemotherapy group.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Maximum Standardized Uptake Value From Staging FDG-PET/CT Does not Predict Treatment Outcome for Early-Stage Non-Small-Cell Lung Cancer Treated With Stereotactic Body Radiotherapy

Purpose: To perform a retrospective review to determine whether maximum standardized uptake values (SUV{sub max}) from staging 2-deoxy-2- [{sup 18}F] fluoro-D-glucose (FDG) positron emission tomography/computed tomography (PET/CT) studies are associated with outcomes for early-stage non-small-cell lung cancer (NSCLC) treated with stereotactic body radiotherapy (SBRT). Methods and Materials: Seventy-two medically inoperable patients were treated between October 17, 2003 and August 17, 2007 with SBRT for T1-2N0M0 NSCLC. SBRT was administered as 60 Gy in 3 fractions, 50 Gy in 5 fractions, or 50 Gy in 10 fractions using abdominal compression and image-guided SBRT. Cox proportional hazards regression was performed to determine whether PET SUV{sub max} and other variables influenced outcomes: mediastinal failure (MF), distant metastases (DM), and overall survival (OS). Results: Biopsy was feasible in 49 patients (68.1%). Forty-nine patients had T1N0 disease, and 23 had T2N0 disease. Median SUV{sub max} was 6.55 (range, 1.5-21). Median follow-up was 16.9 months (range, 0.1-37.9 months). There were 3 local failures, 8 MF, 19 DM, and 30 deaths. Two-year local control, MF, DM, and OS rates were 94.0%, 10.4%, 30.1%, and 61.3%, respectively. In univariate analysis, PET/CT SUV{sub max}, defined either as a continuous or dichotomous variable, did not predict for MF, DM, or OS. On multivariable analysis, the only predictors for overall survival were T1 stage (hazard ratio = 0.331 [95% confidence interval, 0.156-0.701], p = 0.0039) and smoking pack-year history (hazard ratio = 1.015 [95% confidence interval, 1.004-1.026], p = 0.0084). Conclusions: Pretreatment PET SUV{sub max} did not predict for MF, DM, or OS in patients treated with SBRT for early-stage NSCLC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Artifacts in Conventional Computed Tomography (CT) and Free Breathing Four-Dimensional CT Induce Uncertainty in Gross Tumor Volume Determination

Purpose: Artifacts impacting the imaged tumor volume can be seen in conventional three-dimensional CT (3DCT) scans for planning of lung cancer radiotherapy but can be reduced with the use of respiration-correlated imaging, i.e., 4DCT or breathhold CT (BHCT) scans. The aim of this study was to compare delineated gross tumor volume (GTV) sizes in 3DCT, 4DCT, and BHCT scans of patients with lung tumors. Methods and Materials: A total of 36 patients with 46 tumors referred for stereotactic radiotherapy of lung tumors were included. All patients underwent positron emission tomography (PET)/CT, 4DCT, and BHCT scans. GTVs in all CT scans of individual patients were delineated during one session by a single physician to minimize systematic delineation uncertainty. The GTV size from the BHCT was considered the closest to true tumor volume and was chosen as the reference. The reference GTV size was compared to GTV sizes in 3DCT, at midventilation (MidV), at end-inspiration (Insp), and at end-expiration (Exp) bins from the 4DCT scan. Results: The median BHCT GTV size was 4.9 cm{sup 3} (0.1-53.3 cm{sup 3}). Median deviation between 3DCT and BHCT GTV size was 0.3 cm{sup 3} (-3.3 to 30.0 cm{sup 3}), between MidV and BHCT size was 0.2 cm{sup 3} (-5.7 to 19.7 cm{sup 3}), between Insp and BHCT size was 0.3 cm{sup 3} (-4.7 to 24.8 cm{sup 3}), and between Exp and BHCT size was 0.3 cm{sup 3} (-4.8 to 25.5 cm{sup 3}). The 3DCT, MidV, Insp, and Exp median GTV sizes were all significantly larger than the BHCT median GTV size. Conclusions: In the present study, the choice of CT method significantly influenced the delineated GTV size, on average, leading to an increase in GTV size compared to the reference BHCT. The uncertainty caused by artifacts is estimated to be in the same magnitude as delineation uncertainty and should be considered in the design of margins for radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Diabatization with Electrostatic Embedding for Studying Photophysics in Organic Molecular Crystals

Highly emissive organic molecular crystals find applications in several areas, such as organic electronics, solar cells, and sensors. Understanding the excited-state mechanisms underlying these applications is essential for optimizing and controlling them effectively. Exciton models coupled with nonadiabatic dynamics, particularly quantum dynamics, provide crucial insights into photochemical and photophysical processes in molecular crystals. Nevertheless, there remains a lack of general tools and automated workflows to facilitate such simulations. In this paper, we present a computational strategy to investigate the photoactivated dynamics of organic molecular crystals, bridging methodologies traditionally used for molecular systems and materials science, with a particular focus on the interplay between local excitations and charge transfer (CT) processes. We have implemented an interface between the fromage and Overdia programs, enabling the construction of vibronic Hamiltonians for molecular crystals within an excited-state ONIOM(QM:QM′) framework, incorporating long-range electrostatics through a RESP-based Ewald summation. Fragment-based diabatization provides a route to quantum dynamics simulations in weak-to-intermediate coupling regimes. The method was applied to the photophysics of dibenzo[g,p]chrysene (DBC) crystals using time-dependent DFT. The fromage/ Overdia interface was employed to compute the couplings of local excitations and CT states for 18 unique DBC dimers in the crystal and to quantify the influence of electrostatic embedding, which was found to be modest (10−20%). Simulations on π-stacked dimers reproduced the small red shift observed experimentally from solution to crystal, attributed to electronic interactions among fixed monomers rather than crystal electrostatics. Quantum dynamics simulations revealed ultrafast population transfer from bright local excitations to CT states. This approach establishes a robust framework linking molecular and solid-state excited-state dynamics, with potential applications for studying excitations, defects, and impurities in molecular crystals.

Crystals↗

Cryptographic Key Management and Critical Risk Assessment

The Department of Energy Office of Electricity Delivery and Energy Reliability (DOE-OE) CyberSecurity for Energy Delivery Systems (CSEDS) industry led program (DE-FOA-0000359) entitled "Innovation for Increasing CyberSecurity for Energy Delivery Systems (12CSEDS)," awarded a contract to Sypris Electronics LLC to develop a Cryptographic Key Management System for the smart grid (Scalable Key Management Solutions for Critical Infrastructure Protection). Oak Ridge National Laboratory (ORNL) and Sypris Electronics, LLC as a result of that award entered into a CRADA (NFE-11-03562) between ORNL and Sypris Electronics, LLC. ORNL provided its Cyber Security Econometrics System (CSES) as a tool to be modified and used as a metric to address risks and vulnerabilities in the management of cryptographic keys within the Advanced Metering Infrastructure (AMI) domain of the electric sector. ORNL concentrated our analysis on the AMI domain of which the National Electric Sector Cyber security Organization Resource (NESCOR) Working Group 1 (WG1) has documented 29 failure scenarios. The computational infrastructure of this metric involves system stakeholders, security requirements, system components and security threats. To compute this metric, we estimated the stakes that each stakeholder associates with each security requirement, as well as stochastic matrices that represent the probability of a threat to cause a component failure and the probability of a component failure to cause a security requirement violation. We applied this model to estimate the security of the AMI, by leveraging the recently established National Institute of Standards and Technology Interagency Report (NISTIR) 7628 guidelines for smart grid security and the International Electrotechnical Commission (IEC) 63351, Part 9 to identify the life cycle for cryptographic key management, resulting in a vector that assigned to each stakeholder an estimate of their average loss in terms of dollars per day of system operation. To further address probabilities of threats, information security analysis can be performed using game theory implemented in dynamic Agent Based Game Theoretic (ABGT) simulations. Such simulations can be verified with the results from game theory analysis and further used to explore larger scale, real world scenarios involving multiple attackers, defenders, and information assets. The strategy for the game was developed by analyzing five electric sector representative failure scenarios contained in the AMI functional domain from NESCOR WG1. From these five selected scenarios, we characterized them into three specific threat categories affecting confidentiality, integrity and availability (CIA). The analysis using our ABGT simulation demonstrated how to model the AMI functional domain using a set of rationalized game theoretic rules decomposed from the failure scenarios in terms of how those scenarios might impact the AMI network with respect to CIA.

Advanced Metering Infrastructure↗

Centralized Cryptographic Key Management and Critical Risk Assessment - (CRADA Final Report)

The Department of Energy Office of Electricity Delivery and Energy Reliability (DOE-OE) Cyber Security for Energy Delivery Systems (CSEDS) industry led program (DE-FOA-0000359) entitled "Innovation for Increasing Cyber Security for Energy Delivery Systems (12CSEDS)," awarded a contract to Sypris Electronics LLC to develop a Cryptographic Key Management System for the smart grid (Scalable Key Management Solutions for Critical Infrastructure Protection). Oak Ridge National Laboratory (ORNL) and Sypris Electronics, LLC as a result of that award entered into a CRADA (NFE-11-03562) between ORNL and Sypris Electronics, LLC. ORNL provided its Cyber Security Econometrics System (CSES) as a tool to be modified and used as a metric to address risks and vulnerabilities in the management of cryptographic keys within the Advanced Metering Infrastructure (AMI) domain of the electric sector. ORNL concentrated our analysis on the AMI domain of which the National Electric Sector Cyber security Organization Resource (NESCOR) Working Group 1 (WG1) has documented 29 failure scenarios. The computational infrastructure of this metric involves system stakeholders, security requirements, system components and security threats. To compute this metric, we estimated the stakes that each stakeholder associates with each security requirement, as well as stochastic matrices that represent the probability of a threat to cause a component failure and the probability of a component failure to cause a security requirement violation. We applied this model to estimate the security of the AMI, by leveraging the recently established National Institute of Standards and Technology Interagency Report (NISTIR) 7628 guidelines for smart grid security and the International Electrotechnical Commission (IEC) 63351, Part 9 to identify the life cycle for cryptographic key management, resulting in a vector that assigned to each stakeholder an estimate of their average loss in terms of dollars per day of system operation. To further address probabilities of threats, information security analysis can be performed using game theory implemented in dynamic Agent Based Game Theoretic (ABGT) simulations. Such simulations can be verified with the results from game theory analysis and further used to explore larger scale, real world scenarios involving multiple attackers, defenders, and information assets. The strategy for the game was developed by analyzing five electric sector representative failure scenarios contained in the AMI functional domain from NESCOR WG1. From these five selected scenarios, we characterized them into three specific threat categories affecting confidentiality, integrity and availability (CIA). The analysis using our ABGT simulation demonstrated how to model the AMI functional domain using a set of rationalized game theoretic rules decomposed from the failure scenarios in terms of how those scenarios might impact the AMI network with respect to CIA.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Research and technology

The NASA Lewis Research Center's research and technology accomplishments for fiscal year 1987 are summarized. It comprises approximately 100 short articles submitted by staff members of the technical directorates and is organized into four sections: aeronautics, aerospace technology (which includes space communications), space station systems, and computational support. A table of contents by subject was developed to assist the reader in finding articles of special interest.

Source record↗

Cumulative index to NASA Tech Briefs, 1986-1990, volumes 10-14

Tech Briefs are short announcements of new technology derived from the R&D activities of the National Aeronautics and Space Administration. These briefs emphasize information considered likely to be transferrable across industrial, regional, or disciplinary lines and are issued to encourage commercial application. This cumulative index of Tech Briefs contains abstracts and four indexes (subject, personal author, originating center, and Tech Brief number) and covers the period 1986 to 1990. The abstract section is organized by the following subject categories: electronic components and circuits, electronic systems, physical sciences, materials, computer programs, life sciences, mechanics, machinery, fabrication technology, and mathematics and information sciences.

Source record↗

Energy 101: Energy Efficient Data Centers

Data centers provide mission-critical computing functions vital to the daily operation of top U.S. economic, scientific, and technological organizations. These data centers consume large amounts of energy to run and maintain their computer systems, servers, and associated high-performance components—up to 3% of all U.S. electricity powers data centers. And as more information comes online, data centers will consume even more energy. Data centers can become more energy efficient by incorporating features like power-saving "stand-by" modes, energy monitoring software, and efficient cooling systems instead of energy-intensive air conditioners. These and other efficiency improvements to data centers can produce significant energy savings, reduce the load on the electric grid, and help protect the nation by increasing the reliability of critical computer operations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Understanding climate-induced migration through computational modeling: A critical overview with guidance for future efforts

Climate change has the potential to displace large populations in many parts of the developed and developing world. Understanding why, how, and when environmental migrants decide to move is critical to successful strategic planning within organizations tasked with helping the affected groups, and mitigating their systemic impacts. One way to support planning is through the employment of computational modeling techniques. Models can provide a window into possible futures, allowing planners and decision makers to test different scenarios in order to understand what might happen. While modeling is a powerful tool, it presents both opportunities and challenges. This paper builds a foundation for the broader community of model consumers and developers by: providing an overview of pertinent climate-induced migration research, describing some different types of models and how to select the most relevant one(s), highlighting three perspectives on obtaining data to use in said model(s), and the consequences associated with each. It concludes with two case studies based on recent research that illustrate what can happen when ambitious modeling efforts are undertaken without sufficient planning, oversight, and interdisciplinary collaboration. Lastly, we hope that the broader community can learn from our experiences and apply this knowledge to their own modeling research efforts.

54 ENVIRONMENTAL SCIENCES↗

STREAM: A Scalable Federated HPC Telemetry Platform

Obtaining and analyzing high performance computing (HPC) telemetry in real time is a complex task that can impact algo- rithmic performance, operating costs, and ultimately scientific outcomes. If your organization operates multiple HPC systems, filesystems, and clusters, telemetry streams can be synthesized in order to ease operational and analytics burden. In order to collect this telemetry, the Oak Ridge Leadership Computing Facility (OLCF) has deployed STREAM (Streaming Telemetry for Resource Events, Analytics, and Monitoring), which is a distributed and high-performance message bus based on Apache Kafka. STREAM collects center-wide performance information and must interface with many sources, including five HPE deployed supercomputers, each with their own Kafka cluster which is managed by HPCM. OLCF Supercomputers and their attached scratch filesystems currently send more than 300 million messages to over 200 topics producing around 1.3 Terabytes per day of telemetry data to STREAM. This paper describes the architectural principles that enable STREAM to be both resilient and highly performant while supporting multiple upstream Kafka clusters and other data sources. It also discusses the design challenges and decisions faced in adapting our existing system- monitoring infrastructure to support the first Exascale computing platform.

Adamson, Ryan↗

Spin Dynamics of SCRPs in ZnO Quantum Dot–Organic Molecule Conjugates Studied with Pulsed EPR

Photogenerated spin-correlated radical pairs (SCRPs) are emerging as promising new candidates for Quantum Information Science applications, where they act as electron spin qubit pairs (SQPs). Historically, these pairs have been mostly investigated in natural photosynthesis and in molecular organic donor–(linker)–acceptor systems. Recently, we have shown that these spin pairs can also be observed by time-resolved electron-paramagnetic resonance (EPR) spectroscopy in hybrid inorganic–organic conjugates. The current study builds on recent work (ACS Nano, 2025, 19, 12194–12207), in which we systematically prepared hybrid inorganic–organic molecule systems with tunable geometries that can host SCRPs/SQPs. Here, we demonstrate using pulsed EPR spectroscopy that we can generate, study, and manipulate the spins in these photogenerated SCRPs hosted on highly tailorable inorganic–organic hybrid systems. Microwave pulse-based spin manipulation is the first step toward developing quantum computing and quantum sensing applications with these promising spin-based qubit materials, which can be reversibly photogenerated in highly spin-polarized states at moderate temperatures. An attractive feature of this new class of hybrid materials is that the g-factor of the unpaired electron spin in the ZnO QD (as part of the SCRP/SQP) can be adjusted using the quantum size effect in these QDs, which allows for the selective addressability of each spin in the SCRP using microwave pulses. Additionally, we also observed a difference between the g-values of the unpaired electron in the ZnO QD in the transient SCRP state and stable photoreduced state. We hypothesize that the unpaired electron in the SCRP is delocalized as a band-like conduction electron, while in the stable photoreduced state, the electron is delocalized in a shallow electron trap state.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Impact of [{sup 18}F]Fluorodeoxyglucose PET-CT Staging on Treatment Planning in Radiotherapy Incorporating Elective Nodal Irradiation for Non-Small-Cell Lung Cancer: A Prospective Study;Non-small-cell lung cancer; PET; Radiotherapy; Elective nodal irradiation

Purpose: To evaluate prospectively how positron emission tomography (PET) information changes treatment plans for non-small-cell lung cancer (NSCLC) patients receiving or not receiving elective nodal irradiation (ENI). Methods and Materials: One hundred consecutive patients referred for curative radiotherapy were included in the study. Treatment plans were carried out with CT data sets only. For stage III patients, mediastinal ENI was planned. Then, patients underwent PET-CT for diagnostic/planning purposes. PET/CT was fused with the CT data for final planning. New targets were delineated. For stage III patients with minimal N disease (N0-N1, single N2), the ENI was omitted in the new plans. Patients were treated according to the PET-based volumes and plans. The gross tumor volume (GTV)/planning tumor volume (PTV) and doses for critical structures were compared for both data sets. The doses for areas of potential geographical misses derived with the CT data set alone were compared in patients with and without initially planned ENI. Results: In the 75 patients for whom the decision about curative radiotherapy was maintained after PET/CT, there would have been 20 cases (27%) with potential geographical misses by using the CT data set alone. Among them, 13 patients would receive ENI; of those patients, only 2 patients had the PET-based PTV covered by 90% isodose by using the plans based on CT alone, and the mean of the minimum dose within the missed GTV was 55% of the prescribed dose, while for 7 patients without ENI, it was 10% (p = 0.006). The lung, heart, and esophageal doses were significantly lower for plans with ENI omission than for plans with ENI use based on CT alone. Conclusions: PET/CT should be incorporated in the planning of radiotherapy for NSCLC, even in the setting of ENI. However, if PET/CT is unavailable, ENI may to some extent compensate for an inadequate dose coverage resulting from diagnostic uncertainties.

62 RADIOLOGY AND NUCLEAR MEDICINE↗