Search NASA⌕ Search

SEARCH · Search NASA

Results for “conduction cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

The heating of a thermally conducting stratified medium. I - Self-gravitating gas threaded by magnetic fields

Two theoretical problems are presented to illustrate the equilibrium structure of a gravitating gas threaded by magnetic fields. The gas is heated everywhere at a rate proportional to the local density and cooled by thermal conduction channeled along the magnetic field. Emphasis is placed on the influence of anisotropic thermal conduction on the distribution of the gas. In the first problem, the magnetic field has straight field lines that are nearly parallel. The simple field line geometry allows us to calculate, in closed form, the equilibria configurations of a gas slab which is cooled nonuniformly by thermal conduction along field lines which leave the gas slab at varying angles. The problem involves the gas having a free boundary, which is one of the unknowns to be determined. A discussion is given of the set of all possible equilibria so constructed. In the second problem there is no electric current flowing in the gas but there is a potential magnetic field having curved field lines. Exact solutions of equilibriums are presented to illustrate the heating of stellar and galactic coronas.

Lerche, I.↗

Thermal Response of Cooled Silicon Nitride Plate Due to Thermal Conductivity Effects Analyzed

Lightweight, strong, tough high-temperature materials are required to complement efficiency improvements for next-generation gas turbine engines that can operate with minimum cooling. Because of their low density, high-temperature strength, and high thermal conductivity, ceramics are being investigated as materials to replace the nickelbase superalloys that are currently used for engine hot-section components. Ceramic structures can withstand higher operating temperatures and a harsh combustion environment. In addition, their low densities relative to metals help reduce component mass (ref. 1). To complement the effectiveness of the ceramics and their applicability for turbine engine applications, a parametric study using the finite element method is being carried out. The NASA Glenn Research Center remains very active in conducting and supporting a variety of research activities related to ceramic matrix composites through both experimental and analytical efforts (ref. 1). The objectives of this work are to develop manufacturing technology, develop a thermal and environmental barrier coating (TBC/EBC), develop an analytical modeling capability to predict thermomechanical stresses, and perform a minimal burner rig test on silicon nitride (Si3N4) and SiC/SiC turbine nozzle vanes under simulated engine conditions. Moreover, we intend to generate a detailed database of the material s property characteristics and their effects on structural response. We expect to offer a wide range of data since the modeling will account for other variables, such as cooling channel geometry and spacing. Comprehensive analyses have begun on a plate specimen with Si3N4 cooling holes.

Baaklini, George Y.↗

An Analysis of Nuclear-Rocket Nozzle Cooling

A nuclear-rocket regenerative-cooling analysis was conducted over a range of reactor power of 46 to 1600 megawatts and is summarized herein. Although the propellant (hydrogen) is characterized by a large heat-sink capacity, an analysis of the local heat-flux capability of the coolant at the nozzle throat indicated that, for conventional values of system pressure drop, the cooling capability was inadequate to maintain a selected wall temperature of 1440 R. Several techniques for improving the cooling capability were discussed, for example, high pressure drop, high wall temperature, refractory wall coatings, thin highly conductive walls, and film cooling. In any specific design a combination of methods will probably be utilized to achieve successful cooling.

Robbins, William H.↗

Review and status of liquid-cooling technology for gas turbines

A review was conducted of liquid-cooled turbine technology. Selected liquid-cooled systems and methods are presented along with an assessment of the current technology status and requirements. A comprehensive bibliography is presented.

Vanfossen, G. J., Jr.↗

Development of Passive Fuel Cell Thermal Management Technology

The NASA Glenn Research Center is developing advanced passive thermal management technology to reduce the mass and improve the reliability of space fuel cell systems for the NASA exploration program. The passive thermal management system relies on heat conduction within the cooling plate to move the heat from the central portion of the cell stack out to the edges of the fuel cell stack rather than using a pumped loop cooling system to convectively remove the heat. Using the passive approach eliminates the need for a coolant pump and other cooling loop components which reduces fuel cell system mass and improves overall system reliability. Previous analysis had identified that low density, ultra-high thermal conductivity materials would be needed for the cooling plates in order to achieve the desired reductions in mass and the highly uniform thermal heat sink for each cell within a fuel cell stack. A pyrolytic graphite material was identified and fabricated into a thin plate using different methods. Also a development project with Thermacore, Inc. resulted in a planar heat pipe. Thermal conductivity tests were done using these materials. The results indicated that lightweight passive fuel cell cooling is feasible.

Burke, Kenneth A.↗

Testing of a Neon Loop Heat Pipe for Large Area Cryocooling

Cryocooling of large areas such as optics, detector arrays, and cryogenic propellant tanks is required for future NASA missions. A cryogenic loop heat pipe (CLHP) can provide a closed-loop cooling system for this purpose and has many advantages over other devices in terms of reduced mass, reduced vibration, high reliability, and long life. A neon CLHP was tested extensively in a thermal vacuum chamber using a cryopump as the heat sink to characterize its transient and steady performance and verify its ability to cool large areas or components. Tests conducted included loop cool-down from the ambient temperature, startup, power cycle, heat removal capability, loop capillary limit and recovery from a dry-out, low power operation, and long duration steady state operation. The neon CLHP demonstrated robust operation. The loop could be cooled from the ambient temperature to subcritical temperatures very effectively, and could start successfully by applying power to both the pump and evaporator without any pre-conditioning. It could adapt to changes in the pump power andor evaporator power, and reach a new steady state very quickly. The evaporator could remove heat loads between 0.25W and 4W. When the pump capillary limit was exceeded, the loop could resume its normal function by reducing the pump power. Steady state operations were demonstrated for up to 6 hours. The ability of the neon loop to cool large areas was therefore successfully verified.

Cryogenics↗

Mergers, cooling flows, and evaporation

Mergers (the capture of cold gas, especially) can have a profound influence on the hot coronal gas of early-type galaxies and clusters, potentially inducing symptoms hitherto attributed to a cooling flow, if thermal conduction is operative in the coronal plasma. Heat can be conducted from the hot phase into the cold phase, simultaneously ionizing the cold gas to make optical filaments, while locally cooling the coronal gas to mimic a cooling-flow. If there is heat conduction, though, there is no standard cooling-flow since radiative losses are balanced by conduction and not mass deposition. Amongst the strongest observational support for the existence of cooling-flows is the presence of intermediate temperature gas with x-ray emission-line strengths in agreement with cooling-flow models. Here, x-ray line strengths are calculated for this alternative model, in which mergers are responsible for the observed optical and x-ray properties. Since gas around 10(exp 4) K is thermally stable, the cold cloud need not necessarily evaporate and hydrostatic solutions exist. Good agreement with the x-ray data is obtained. The relative strengths of intermediate temperature x-ray emission lines are in significantly better agreement with a simple conduction model than with published cooling-flow models. The good agreement of the conduction model with optical, infrared and x-ray data indicates that significantly more theoretical effort into this type of solution would be profitable.

Sparks, W. B.↗

Cosmic-ray heating of cooling flows - A critical analysis

It is shown that a combination of MHD wave-mediated cosmic ray heating and thermal conduction could balance cooling in intracluster media and substantially reduce the rate of inflow. The appropriate system of steady state equations is solved, including a new self-consistent formulation for the cosmic-ray diffusivity. Models which can produce substantial positive temperature gradients in static configurations are found when conduction is reduced by a factor of 10 or more. These models have too-flat thermal pressure profiles compared with observations. It is found that cosmic-ray heating is unlikely either to stabilize positive density perturbations against condensation or to contribute appreciably to the powering of the optical filaments.

Loewenstein, Michael↗

High precision magnetic field measurement and mapping of the LEReC 180 degree bending magnet using very low field NMR with hall combined probe (140 - 350 gauss)

The Relativistic Heavy Ion Collider (RHIC) at BNL are using the Low Energy RHIC Electron Cooling (LEReC) to conduct experiments that search for the quantum chromodynamic (QCD) critical point. The first ever electron cooling based on the RF acceleration of electron beams was experimentally demonstrated on April 5, 2019 at LEReC at BNL. The first critical step in obtaining successful 3D non-magnetized cooling of the Au ion bunches in the RHIC cooling section was matching the electron beam energy with a relative error less than 5*10 -4 to the ion beam energy. Part of the LEReC beamline is a dipole magnet that bends the electron beam 180 degree. One of the most outstanding measurement challenges is that the dipole field is so low (≈200 G). Most of the existing NMR probes can only measure fields >400 G. Lower signal-to-noise ratio at low fields is requires the use of larger sample volumes. Working with CAYLAR, a NMR probe has been redesigned and optimized for these low field measurements with high resolution. We report the methods, challenges, and results for extensive magnetic field mappings of the 180 dipole magnet. A combination of NMR and Hall sensors has been successfully implemented to measure uniform field regimes inside the magnet center area and non-uniform field regimes at the magnet ends. Detailed measurement and mapping have been performed at five radii and five heights along the beam trajectory. Meanwhile a finite element magnetic modeling simulation of the magnet using Opera software has been performed. The calculated and measured data are compared, and the calculated data is good reference for measured data over long length mapping from magnet edge to center. The measured magnetic measurement data is directly useful for beam instrumentation, diagnostics and operation.

Magnetic Field Measurement↗

Sweeping Jet Film Cooling at High Blowing Ratio on a Turbine Vane

Abstract Experimental and numerical investigations were performed to study the effects of high blowing ratios and high freestream turbulence on sweeping jet film cooling. Experiments were conducted on a nozzle guide vane suction surface in a low-speed linear cascade at a range of blowing ratios of 0.5–3.5 and freestream turbulence of 0.6% and 14.3%. Infrared thermography was used to estimate the adiabatic cooling effectiveness. Thermal field and boundary layer measurements were conducted at a cross-plane at x/D = 12 downstream of the hole exit. Results were compared with a baseline 777-shaped hole and showed that the sweeping jet hole has improved cooling effectiveness at high blowing ratios (M > 1). The thermal field data revealed that the coolant separates from the surface at high blowing ratios for the 777-shaped hole while the coolant remains attached for the sweeping jet hole. Boundary layer measurements further confirmed that due to the sweeping motion of the jet, the effective jet momentum of the sweeping jet hole remains much lower than that of a 777-shaped hole. Thus, the coolant remains closer to the wall even at high blowing ratios. Large Eddy simulations (LES) were performed for both the sweeping jet and 777-shaped hole to evaluate the interaction between the coolant jet and the freestream in the near hole regions. Results showed that 777-shaped hole has a strong jetting at high blowing ratio that originates inside the hole breakout edges thus causing the jet to blow-off from the surface. In contrast, the sweeping jet does not show this behavior due to its internal geometry and flapping motion of the jet.

Engineering↗

Effect of free-stream turbulence on film cooling

Film-cooling experiments were conducted at four levels of free-stream turbulence to test the hypothesis that the film-cooling effectiveness is inversely related to the free-stream turbulence level. The hot-gas operating conditions were held constant at a temperature of 590 K, a pressure of 1 atmosphere, and a velocity of 62 m/sec. The film-cooling air was at ambient inlet temperature, and the film-cooling flow rates were 2.5, 5.0, 7.5, and 10.0 percent of the total airflow. Blockage plates with blockage areas of 0, 52, 72, and 90 percent were placed upstream of the film-cooling slot and produced axial turbulence intensities of 7, 14, 23, and 35 percent, respectively. The film-cooling effectiveness decreased as much as 50 percent as the freestream turbulence intensity was increased from 7 to 35 percent. The value of the turbulent mixing coefficient used in previous work was compared with the axial turbulence intensity. The turbulent mixing coefficient was found to be 10 to 40 percent of the axial turbulence intensity.

Marek, C. J.↗

Mathematical equations for heat conduction in the fins of air-cooled engines

The problem considered in this report is that of reducing actual geometrical area of fin-cooling surface, which is, of course, not uniform in temperature, to equivalent cooling area at one definite temperature, namely, that prevailing on the cylinder wall at the point of attachment of the fin. This makes it possible to treat all the cooling surface as if it were part of the cylinder wall and 100 per cent effective. The quantities involved in the equations are the geometrical dimensions of the fin, thermal conductivity of the material composing it, and the coefficient of surface heat dissipation between the fin and the air streams.

Harper, R R↗

Multiphysics Computational Analysis of a Perforated Plate Cooling Flow

A multiphysics analysis of a film cooling flow was conducted using a computational fluid dynamics (CFD) solver in conjunction with a conjugate heat transfer (CHT) solver. The film cooling problem consisted of a square nozzle producing a heated subsonic jet over a perforated plate with three sections of 45 cooling holes each. Results from the multiphysics analysis were compared to a CFD-only approach and experimental results. Reynolds-averaged Navier-Stokes (RANS) computations were employed first, with and without the CHT solver. The multiphysics approach provided much closer agreement with experimentally measured plate temperatures than the CFD-only approach. Comparisons of computed velocities and temperatures were also made with experimental data. Hybrid RANS-large eddy simulation calculations employing the Delayed Detached Eddy Simulation (DDES) approach were also conducted within the multiphysics framework. The DDES approach was unable to resolve turbulent structures in the near wall regions. Hence, the RANS part of the DDES model was used in near wall regions, and produced surface temperatures along with velocity and temperature profiles close to the wall that were very similar to the RANS results. The DDES approach did resolve structures in the outer portion of the boundary layer especially near the end of the plate where the boundary layer was thicker. The key result was the improved surface temperatures produced by the multiphysics approach employing CHT over the fluid-only approach.

Computational Fluid Dynamics↗

Thermal Performance Testing of EMU and OSS Liquid Cooling Garments

A test was conducted to evaluate three factors influencing the thermal performance of liquid cooling garments (LCG): (1) the comparable thermal performance of an Oceaneering developed engineering evaluation unit (EEU) prototype LDG, (2) the effect of the thermal comfort undergarment (TCU), and (3) the performance of a torso or upper body only LCG configuration. To evaluate the thermal performance of each configuration a metabolic test was conducted, utilizing suited subjects to generate the metabolic heat. For this study three (3) test subjects of similar health and weight produced a metabolic load on the LDG configuration by either resting (300-600 BTU/hr), walking at a slow pace (1200 BRU/hr), and walking at a brisk pace (2200 BTU/hr), as outlined in Figure 1, the metabolic profile. During the test, oxygen consumption, heart rate, relative humidity, air flow, inlet and outlet air pressure, inlet and outlet air temperature, delta air temperature, water flow (100 lb/hr), inlet water temperature (64 F), delta water temperature, water pressure, core body temperature, skin temperature, and sweat loss data was recorded. Four different test configurations were tested, with one configuration tested twice, as outlined in Table 1. The test was conducted with the suit subjects wearing the Demonstrator Suit, pressurized to vent pressure (approximately 0.5 psig). The demonstrator suit has an integrated ventilation duct system and was used to create a relevant environment with a captured ventilation return, an integrated vent tree, and thermal insulation from the environment.

Rhodes, Richard↗

Evaporative cooling of flare plasma

A one-dimensional loop model for the evaporative cooling of the coronal flare plasma was investigated. Conductive losses dominated radiative cooling, and the evaporative velocities were small compared to the sound speed. The profile and evolution of the temperature were calculated. The model was in agreement with soft X-ray observations on the evolution of flare temperatures and emission measures. The effect of evaporation was to greatly reduce the conductive heat flux into the chromosphere and to enhance the EUV emission from the coronal flare plasma.

Antiochos, S. K.↗

Evaluation of water cooled supersonic temperature and pressure probes for application to 2000 F flows

The development of water cooled supersonic probes used to study high temperature jet plumes is addressed. These probes are: total pressure, static pressure, and total temperature. The motivation for these experiments is the determination of high temperature supersonic jet mean flow properties. A 3.54 inch exit diameter water cooled nozzle was used in the tests. It is designed for exit Mach 2 at 2000 F exit total temperature. Tests were conducted using water cooled probes capable of operating in Mach 2 flow, up to 2000 F total temperature. Of the two designs tested, an annular cooling method was chosen as superior. Data at the jet exit planes, and along the jet centerline, were obtained for total temperatures of 900 F, 1500 F, and 2000 F, for each of the probes. The data obtained from the total and static pressure probes are consistent with prior low temperature results. However, the data obtained from the total temperature probe was affected by the water coolant. The total temperature probe was tested up to 2000 F with, and without, the cooling system turned on to better understand the heat transfer process at the thermocouple bead. The rate of heat transfer across the thermocouple bead was greater when the coolant was turned on than when the coolant was turned off. This accounted for the lower temperature measurement by the cooled probe. The velocity and Mach number at the exit plane and centerline locations were determined from the Rayleigh-Pitot tube formula.

Lagen, Nicholas T.↗

A high temperature thermal diffusivity determination procedure for solids and liquids

A new method for measuring the thermal diffusivity of materials at high temperatures is presented. The method is applicable to solids on Earth, and to liquids in the reduced gravity environment of space. It is especially suited to levitated liquid metals at elevated temperatures where thermal diffusivity data is not available. The method is applied in two parts, such that lumped analysis is valid in the first part, and Fourier's law of conduction is valid in the second. In both parts, the spherical specimen is assumed to have been heated to a desired temperature and cooled. An inverse conduction problem is then formulated and solved using Laplace transformation techniques. Using this solution, sample sizes, and experimentally obtained surface temperature history, the thermal diffusivity is determined by minimizing a function that satisifies the heat balance at the surface. Minimization is performed using a modified quasilinearization algorithm. Accuracy is very sensitive to error in the temperature data and increases with better curve fits to the temperature data. An error analysis is also performed, and the effect of errors in the various parameters on the evaluated thermal diffusivity is determined. An experimental study for solids on Earth is suggested, before development for implementation in space.

Bayazitoglu, Yildiz↗