High Performance Computing Innovation Center Open Source Developer Tools

The High Performance Computing Innovation Center (HPCIC) aims to ease the transition for developers to use open source software provided by the lab. HPCIC Developer Tools is a collection of software, containers, cloud configurations, and associated documentation that make it easy to deploy tutorials or small apps to demonstrate lab-developed software. For example, building a tutorial container that includes lab software and interactive interfaces; a command line or web-based tool that accepts user preferences for the tutorial; supporting tools and software development kits (SDKs) for developer interactions or productivity in different languages embraced by the larger developer community such as Go, Rust, and Python; and automation in version control to support continued update of software and associated resources. These tools are best developed in an open source environment such as GitHub, not only to champion the lab's open source software, but for purposes of branding and demonstrating the lab's leadership in open source. Such an effort that brings in more developers to use and contribute to lab software can further improve the quality of the software, and developer experience at the lab.

Beckingsale, DavidA↗

NSTAR Smart Grid Pilot

NSTAR Electric & Gas Corporation (“the Company”, or “NSTAR”) developed and implemented a Smart Grid pilot program beginning in 2010 to demonstrate the viability of leveraging existing automated meter reading (“AMR”) deployments to provide much of the Smart Grid functionality of advanced metering infrastructure (“AMI”), but without the large capital investment that AMI rollouts typically entail. In particular, a central objective of the Smart Energy Pilot was to enable residential dynamic pricing (time-of-use “TOU” and critical peak rates and rebates) and two-way direct load control (“DLC”) by continually capturing AMR meter data transmissions and communicating through customer-sited broadband connections in conjunction with a standards-based home area network (“HAN”). The pilot was supported by the U.S. Department of Energy’s (“DOE”) through the Smart Grid Demonstration program. NSTAR was very pleased to not only receive the funding support from DOE, but the guidance and support of the DOE throughout the pilot. NSTAR is also pleased to report to the DOE that it was able to execute and deliver a successful pilot on time and on budget. NSTAR looks for future opportunities to work with the DOE and others in future smart grid projects.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Biofuel Micro-Refineries for Local Sustainability (Final Report)

This project demonstrated the adaptability of commercial off-the-shelf instrumentation and controls designed for continuous flow large-scale refineries to a transportable micro-scale refinery that will enable production of fuel from bio-feedstock by small groups such as a municipality or farmer cooperative.

09 BIOMASS FUELS↗

Program Management Plan EnCore ® Accident Tolerant Fuel (ATF) Program

This Program Management Plan (PMP) is developed to support Westinghouse’s vision of developing and commercializing the Accident Tolerant Fuel. The near term goal of this Program is to deliver 2 fuel assemblies that consists of LTRs for Exelon Byron Unit 2 in spring of 2019. The longer term goal of this program is deployment of LTAs in 2022 of a mixture of coated zirconium cladding and SiC cladding with ADOPT and U3Si2 fuels. This is a high complexity program and is one of the largest research and development programs in Westinghouse and as such, the project scope is expected to change continuously. Integrated change control will be invoked as necessary. The Program consists of multiple funding streams (internal through Westinghouse innovation funding), external (through the DOE). The DOE funding consists of two phases: 1. Phase 2 – funded by DOE award number DE-NE0008222. 2. Phase 2B – funded by DOE – Westinghouse proposal reference # LTR-AMER-MKG-18-826, Rev. 1, August 23, 2018 (10/18 to 2/21), Award No. DE-NE0008824. 3. Cost share contributions from Westinghouse and program partners.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Science Validation for Dark Energy Research with Optical Imaging Surveys

The Universe has been expanding at an accelerating rate over the past several billion years, as though an unknown form of dark energy permeates all of space. The ultimate scientific goal of the proposed research is to distinguish between different physical mechanisms that could account for this observed accelerated expansion, for example, the zero-point energy of the vacuum, a dynamical form of energy that varies in time and/or space, or a modification to our theory of gravity. Wide- field optical imaging surveys of the night sky can test these competing models by measuring both the cosmic expansion history and the growth of large-scale structure. To this end, the Dark Energy Survey (DES) has cataloged several hundred million galaxies and thousands of supernovae. The Vera C. Rubin Observatory Legacy Survey of Space and Time (LSST), will enlarge the census to billions of galaxies and hundreds of thousands of supernovae. A critical question for these dark energy experiments is whether systematic uncertainties can continue to be controlled at a level to keep pace with the statistical precision offered by such enormous datasets. The immediate research objectives of this project were (1) to prepare and validate input datasets that are the foundation of cosmological analyses with DES, and (2) to prepare for value-added characterization of Rubin Observatory commissioning data to inform early operations and accelerate the realization of dark energy science from LSST data products. For DES, we assembled and curated cosmology-ready data releases that include value-added components such as enhanced photometric and astrometric calibrations, alternative source extraction algorithms, maps of the survey coverage and survey conditions, object classifications, object quality selections, galaxy shapes, and photometric redshifts. We used the galaxy clustering technique to validate the photometric redshift distributions of various galaxy samples to be used as lenses in combined studies of galaxy clustering and weak gravitational lensing. The galaxy clustering redshift analysis was enhanced by use of a larger sample of reference galaxies from the eBOSS spectroscopic survey that extends to higher redshifts. For LSST, we prepared for science validation studies of commissioning data aimed at dark energy science capability that extend beyond the normative system-level tests to be done by the Rubin Observatory Construction Project. We identified a set of proposed survey strategies and candidate target fields that could be observed during the commissioning period to enhance science validation activities related to studies of dark energy.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Porous Organic Cage Membranes for Molecular Gas Separations (Final Technical Report for DE-SC0021357)

This proposal aims at demonstrating the development of a novel family of membranes, composed of porous organic cages (POC) which offer the possibility of displaying high separation performance for challenging molecular gas separations relevant to natural gas purification, and olefin/paraffin separation. The proposed POCs synthesized in membrane form will display the most desirable properties of polymers (facile processability and flexibility) and inorganic materials (hierarchically ordered pores with molecular sieving properties) leading to highly selective and permeable membranes. POCs should display distinctive structural, compositional, adsorption and transport properties than those of conventional porous materials, opening the doors for a new research direction in membrane science, and gas separations. Our preliminary results demonstrate the feasibility of preparing POC crystals with controlled size, and continuous POC membranes with remarkable high permeances, and separation ability for CO 2 /CH 4 , N 2 /CH 4 and C 3 H 6 /C 3 H 8 separations serving as a solid foundation for our proposed work. Fundamentally, this proposal aims at elucidating separation mechanisms of different gas mixtures related to natural gas composition, and olefin/paraffin separation over porous organic cage membranes. The proposed research will result in fundamental understanding of adsorption and transport properties of industrially relevant gas molecules through novel microporous membranes, and may lead to the development of a cost effective membrane technology for natural gas purification, and olefin/paraffin separation surpassing the conventional benchmark technology distillation. Furthermore, we aim at demonstrating selective water transport through POC membranes, which can be positively impactful in numerous industrial applications in which water is present. The ability to fabricate thin, chemically and mechanically stable POC membranes for societal relevant gas separations constitute a new and distinctive direction in membrane science. Our proposed work aims at addressing some of the challenges recognized in the Research Agenda for Transforming Separation Science . Specifically: (a) advancing understanding of complex mixtures on separation performance; (b) exploring thermodynamic and kinetic mechanisms through the elucidation of separation mechanisms, and (c) study potential stability issues of the membranes to be assessed by evaluating the long term membrane stability and performance at various temperatures and pressures. The team is uniquely qualified to execute the proposed work. The PI has solid expertise in the rational molecular engineering design of porous crystalline membranes for molecular gas separations. The PNNL collaborator has extensive experience in the synthesis, characterization, and functional applications of microporous crystals, with particular emphasis on gas adsorption.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measuring OutdoorAir Intake Rates Using Electronic Velocity Sensors at Louvers and Downstream of Airflow Straighteners

Practical and accurate technologies are needed for continuously measuring and controlling outdoor air (OA) intake rates in commercial building heating, ventilating, and air conditioning (HVAC) systems. This project evaluated two new measurement approaches. Laboratory experiments determined that OA flow rates were measurable with errors generally less than 10percent using electronic air velocity probes installed between OA intake louver blades or at the outlet face of louvers. High accuracy was maintained with OA flow rates as low as 15percent of the maximum for the louvers. Thus, with this measurement approach HVAC systems do not need separate OA intakes for minimum OA supply. System calibration parameters are required for each unique combination of louver type and velocity sensor location but calibrations are not necessary for each system installation. The research also determined that the accuracy of measuring OA flow rates with velocity probes located in the duct downstream of the intake louver was not improved by installing honeycomb airflow straighteners upstream of the probes. Errors varied with type of upstream louver, were as high as 100percent, and were often greater than 25percent. In conclusion, use of electronic air velocity probes between the blades of OA intake louvers or at the outlet face of louvers is a highly promising means of accurately measuring rates of OA flow into HVAC systems. The use of electronic velocity probes downstream of airflow straighteners is less promising, at least with the relatively small OA HVAC inlet systems employed in this research.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Evaluation for Modular, Scalable Overhead Cooling Systems In Data Centers

Scientific and enterprise data centers, IT equipment product development, and research data center laboratories typically require continuous cooling to control inlet air temperatures within recommended operating levels for the IT equipment. The consolidation and higher density aggregation of slim computing, storage and networking hardware has resulted in higher power density than what the raised-floor system design, coupled with commonly used computer rack air conditioning (CRAC) units, was originally conceived to handle. Many existing data centers and newly constructed data centers adopt CRAC units, which inherently handle heat transfer within data centers via air as the heat transfer media. This results in energy performance of the ventilation and cooling systems being less than optimal. Understanding the current trends toward higher power density in IT computing, more and more IT equipment manufacturers are designing their equipment to operate in 'conventional' data center environments, while considering provisions of alternative cooling solutions to either their equipment or supplemental cooling in rack or row systems. Naturally, the trend toward higher power density resulting from current and future generations of servers has, in the meanwhile, created significant opportunities for precision cooling suppliers to engineer and manufacture packaged modular and scalable systems. The modular and scalable cooling systems aim at significantly improving efficiency while addressing the thermal challenges, improving reliability, and allowing for future needs and growth. Such pre-engineered and manufactured systems may be a significant improvement over current design; however, without an energy efficiency focus, their applications could also lead to even lower energy efficiencies in the overall data center infrastructure. The overall goal of the project supported by California Energy Commission was to characterize four commercially available, modular cooling systems installed in a data center. Such modular cooling systems are all scalable localized units, and will be evaluated in terms of their operating energy efficiency in a real data center, respectively, as compared to the energy efficiency of traditional legacy data center cooling systems. The technical objective of this project was to evaluate the energy performance of one of the four commercially available modular cooling systems installed in a data center in Sun Microsystems, Inc. This report is the result of a test plan that was developed with the industrial participants' input, including specific design and operating characteristics of the selected modular localized cooling solution provided by vendor 1. The technical evaluation included monitoring and measurement of selected parameters, and establishing and calculating energy efficiency metrics for the selected cooling product, which is a modular, scalable overhead cooling system. The system was tested in a hot/cold aisle environment without separation, or containment or the hot or cold aisles. The scope of this report is to quantify energy performance of the modular cooling unit in operation as it corresponds to a combination of varied server loads and inlet air temperatures. The information generated from this testing when combined with a concurrent research study to document the energy efficiency of the host data center's central chilled water cooling plant can be used to estimate potential energy savings from implementing modular cooling compared to conventional cooling in data centers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Evaluation for Modular, Scalable Cooling Systems with Hot Aisle Containment in Data Centers

Scientific and enterprise data centers, IT equipment product development, and research data center laboratories typically require continuous cooling to control inlet air temperatures within recommended operating levels for the IT equipment. The consolidation and higher density aggregation of slim computing, storage and networking hardware has resulted in higher power density than what the raised-floor system design, coupled with commonly used computer rack air conditioning (CRAC) units, was originally conceived to handle. Many existing data centers and newly constructed data centers adopt CRAC units, which inherently handle heat transfer within data centers via air as the heat transfer media. This results in energy performance of the ventilation and cooling systems being less than optimal. Understanding the current trends toward higher power density in IT computing, more and more IT equipment manufacturers are designing their equipment to operate in 'conventional' data center environments, while considering provisions of alternative cooling solutions to either their equipment or supplemental cooling in rack or row systems. Naturally, the trend toward higher power density resulting from current and future generations of servers has, in the meanwhile, created significant opportunities for precision cooling suppliers to engineer and manufacture packaged modular and scalable systems. The modular and scalable cooling systems aim at significantly improving efficiency while addressing the thermal challenges, improving reliability, and allowing for future needs and growth. Such pre-engineered and manufactured systems may be a significant improvement over current design; however, without an energy efficiency focus, their applications could also lead to even lower energy efficiencies in the overall data center infrastructure. The overall goal of the project supported by California Energy Commission was to characterize four commercially available, modular cooling systems installed in a data center. Such modular cooling systems are all scalable localized units, and will be evaluated in terms of their operating energy efficiency in a real data center, respectively, as compared to the energy efficiency of traditional legacy data center cooling systems. The technical objective of this project was to evaluate the energy performance of one of the four commercially available modular cooling systems installed in a data center in Sun Microsystems, Inc. This report is the result of a test plan that was developed with the industrial participants input, including specific design and operating characteristics of the selected modular localized cooling solution provided by vendor 2. The technical evaluation included monitoring and measurement of selected parameters, and establishing and calculating energy efficiency metrics for the selected cooling product, which is a modular, scalable pair of chilled water cooling modules that were tested in a hot/cold aisle environment with hot aisle containment. The scope of this report is to quantify energy performance of the modular cooling unit in operation as it corresponds to a combination of varied server loads and inlet air temperatures. The information generated from this testing when combined with a concurrent research study to document the energy efficiency of the host data center's central chilled water cooling plant can be used to estimate potential energy savings from implementing modular cooling compared to conventional cooling in data centers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Evaluation for Modular, Scalable Liquid-Rack Cooling Systems in Data Centers

Scientific and enterprise data centers, IT equipment product development, and research data center laboratories typically require continuous cooling to control inlet air temperatures within recommended operating levels for the IT equipment. The consolidation and higher density aggregation of slim computing, storage and networking hardware has resulted in higher power density than what the raised-floor system design, coupled with commonly used computer rack air conditioning (CRAC) units, was originally conceived to handle. Many existing data centers and newly constructed data centers adopt CRAC units, which inherently handle heat transfer within data centers via air as the heat transfer media. This results in energy performance of the ventilation and cooling systems being less than optimal. Understanding the current trends toward higher power density in IT computing, more and more IT equipment manufacturers are designing their equipment to operate in 'conventional' data center environments, while considering provisions of alternative cooling solutions to either their equipment or supplemental cooling in rack or row systems. In the meanwhile, the trend toward higher power density resulting from current and future generations of servers has created significant opportunities for precision cooling suppliers to engineer and manufacture packaged modular and scalable systems. The modular and scalable cooling systems aim at significantly improving efficiency while addressing the thermal challenges, improving reliability, and allowing for future needs and growth. Such pre-engineered and manufactured systems may be a significant improvement over current design; however, without an energy efficiency focus, their applications could also lead to even lower energy efficiencies in the overall data center infrastructure. The overall goal of the project supported by California Energy Commission was to characterize four commercially available, modular cooling systems installed in a data center. Such modular cooling systems are all scalable localized units, and will be evaluated in terms of their operating energy efficiency in a real data center, respectively, as compared to the energy efficiency of traditional legacy data center cooling systems. The technical objective of this project was to evaluate the energy performance of one of the four commercially available modular cooling systems installed in a data center in Sun Microsystems, Inc. This report is the result of a test plan that was developed with the industrial participants input, including specific design and operating characteristics of the selected modular localized cooling solution provided by vendor 3. The technical evaluation included monitoring and measurement of selected parameters, and establishing and calculating energy efficiency metrics for the selected cooling product, which is a modular, scalable liquid-rack cooling system in this study. The scope is to quantify energy performance of the modular cooling unit in operation as it corresponds to a combination of varied server loads and inlet air temperatures, under various chilled-water supply temperatures. The information generated from this testing when combined with documented energy efficiency of the host data center's central chilled water cooling plant can be used to estimate potential energy savings from implementing modular cooling compared to conventional cooling in data centers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Evaluation for a Modular, Scalable Passive Cooling System in Data Centers

Scientific and enterprise data centers, IT equipment product development, and research data center laboratories typically require continuous cooling to control inlet air temperatures within recommended operating levels for the IT equipment. The consolidation and higher density aggregation of slim computing, storage and networking hardware has resulted in higher power density than what the raised-floor system design, coupled with commonly used computer rack air conditioning (CRAC) units, was originally conceived to handle. Many existing data centers and newly constructed data centers adopt CRAC units, which inherently handle heat transfer within data centers via air as the heat transfer media. This results in energy performance of the ventilation and cooling systems being less than optimal. Understanding the current trends toward higher power density in IT computing, more and more IT equipment manufacturers are designing their equipment to operate in 'conventional' data center environments, while considering provisions of alternative cooling solutions to either their equipment or supplemental cooling in rack or row systems. In the meanwhile, the trend toward higher power density resulting from current and future generations of servers has created significant opportunities for precision cooling to engineer and manufacture packaged modular and scalable systems. The modular and scalable cooling systems aim at significantly improving efficiency while addressing the thermal challenges, improving reliability, and allowing for future needs and growth. Such pre-engineered and manufactured systems may be a significant improvement over current design; however, without an energy efficiency focus, their applications could also lead to even lower energy efficiencies in the overall data center infrastructure. The overall goal of the project supported by California Energy Commission was to characterize four commercially available, modular cooling systems installed in a data center. Such modular cooling systems are all scalable localized units, and will be evaluated in terms of their operating energy efficiency in a real data center, respectively, as compared to the energy efficiency of traditional legacy data center cooling systems. The technical objective of this project was to evaluate the energy performance of one of the four commercially available modular cooling systems installed in a data center in Sun Microsystems, Inc. This report is the result of a test plan that was developed with the industrial participants input, including specific design and operating characteristics of the selected passive, modular localized cooling solution provided by vendor 4. The technical evaluation included monitoring and measurement of selected parameters, and establishing and calculating energy efficiency metrics for the selected cooling product, which is a passive, modular, scalable liquid cooling system in this study. The scope is to quantify energy performance of the modular cooling unit corresponding to various server loads and inlet air temperatures, under various chilled-water supply temperatures. The information generated from this testing when combined with documented energy efficiency of the host data center's central chilled water cooling plant can be used to estimate potential energy savings from implementing modular cooling compared to conventional cooling in data centers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measuring Outdoor Air Intake Rates into Existing Building

Practical and accurate technologies are needed for continuously measuring and controlling outdoor air (OA) intake rates in commercial building heating, ventilating, and air conditioning (HVAC) systems. This project evaluated two new measurement approaches. Laboratory experiments determined that OA flow rates were measurable with errors generally less than 10 percent using electronic air velocity probes installed between OA intake louver blades or at the outlet face of louvers. High accuracy was maintained with OA flow rates as low as 15 percent of the maximum for the louvers. Thus, with this measurement approach HVAC systems do not need separate OA intakes for minimum OA supply. System calibration parameters are required for each unique combination of louver type and velocity sensor location but calibrations are not necessary for each system installation. The research also determined that the accuracy of measuring OA flow rates with velocity probes located in the duct downstream of the intake louver was not improved by installing honeycomb airflow straighteners upstream of the probes. Errors varied with type of upstream louver, were as high as 100 percent, and were often greater than 25 percent. In conclusion, use of electronic air velocity probes between the blades of OA intake louvers or at the outlet face of louvers is a highly promising means of accurately measuring rates of OA flow into HVAC systems. The use of electronic velocity probes downstream of airflow straighteners is less promising, at least with the relatively small OA HVAC inlet systems employed in this research.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Sorghum bicolor BTx623 Nitrogen Grown Conditions Gene Expression Profiling

Dhurrin, a cyanogenic glucoside, plays an important role in Sorghum bicolor physiology and defense. The concentration of dhurrin in sorghum is influenced by both nitrogen status and stage of plant organ development. While nitrogen resupply activates the expression of genes for dhurrin biosynthesis, the molecular mechanisms underlying this regulation remain unclear. In this study, we investigated the transcriptional response of sorghum to nitrogen resupply following growth under nitrogen-limiting conditions. Using a time-course design, we measured hydrogen cyanide potential (HCNp), growth, and nitrate content at 0-, 2-, 6-, 12-, 24-, 36-, 48-, and 60-h after resupply and collected tissue for RNAseq analysis in parallel for analysis of gene expression and construction of gene regulatory networks (GRNs). HCNp (mg g−1 DW) increased significantly in leaf and stem tissues following nitrogen resupply, with increases in the leaf partially driven by continued declines in controls under ongoing nitrogen stress. Expression of the dhurrin pathway genes was upregulated in leaves from 24 h after nitrogen resupply, with diel expression patterns observable over the remaining time points. No upregulation was observed in roots or stems, suggesting that developmental context overrides environmental cues. GRN analysis identified candidate transcription factors regulating dhurrin biosynthesis genes, including members of the MYB, bZIP, and GARP-type transcription factor families. Some of these candidate transcription factors may be involved in relieving senescence-associated suppression of dhurrin biosynthesis and link nitrogen signaling to pathway activation. These findings provide new insight into the nitrogen-responsive regulation of dhurrin in sorghum, highlighting candidate regulators for future functional characterization.

cyanogenic glucoside↗

Sorghum bicolor BTx623 Nitrogen Grown Conditions Set2 Gene Expression Profiling

Dhurrin, a cyanogenic glucoside, plays an important role in Sorghum bicolor physiology and defense. The concentration of dhurrin in sorghum is influenced by both nitrogen status and stage of plant organ development. While nitrogen resupply activates the expression of genes for dhurrin biosynthesis, the molecular mechanisms underlying this regulation remain unclear. In this study, we investigated the transcriptional response of sorghum to nitrogen resupply following growth under nitrogen-limiting conditions. Using a time-course design, we measured hydrogen cyanide potential (HCNp), growth, and nitrate content at 0-, 2-, 6-, 12-, 24-, 36-, 48-, and 60-h after resupply and collected tissue for RNAseq analysis in parallel for analysis of gene expression and construction of gene regulatory networks (GRNs). HCNp (mg g−1 DW) increased significantly in leaf and stem tissues following nitrogen resupply, with increases in the leaf partially driven by continued declines in controls under ongoing nitrogen stress. Expression of the dhurrin pathway genes was upregulated in leaves from 24 h after nitrogen resupply, with diel expression patterns observable over the remaining time points. No upregulation was observed in roots or stems, suggesting that developmental context overrides environmental cues. GRN analysis identified candidate transcription factors regulating dhurrin biosynthesis genes, including members of the MYB, bZIP, and GARP-type transcription factor families. Some of these candidate transcription factors may be involved in relieving senescence-associated suppression of dhurrin biosynthesis and link nitrogen signaling to pathway activation. These findings provide new insight into the nitrogen-responsive regulation of dhurrin in sorghum, highlighting candidate regulators for future functional characterization.

cyanogenic glucoside↗

Embedding Agile Practices within a Plan-Driven Hierarchical Project Life Cycle

Organizations use structured, plan-driven approaches to provide continuity, direction, and control to large, multi-year programs. Projects within these programs vary greatly in size, complexity, level of maturity, technical risk, and clarity of the development objectives. Organizations that perform exploratory research, evolutionary development, and other R&D activities can obtain the benefits of Agile practices without losing the benefits of their program’s overarching plan-driven structure. This paper describes application of Agile development methods on a large plan-driven sensor integration program. While the client employed plan-driven, requirements flow-down methodologies, tight project schedules and complex interfaces called for frequent end-to-end demonstrations to provide feedback during system development. The development process maintained the many benefits of plan-driven project execution with the rapid prototyping, integration, demonstration, and client feedback possible through Agile development methods. This paper also describes some of the tools and implementing mechanisms used to transition between and take advantage of each methodology, and presents lessons learned from the project management, system engineering, and developer’s perspectives.

Agile Development↗

Optical spectroscopy system and method for monitoring liquid phase chemical reactions

A system for monitoring a chemical reaction in a liquid reactor system includes a sample liquid conduit in communication with the liquid reactor system for receiving sample liquid and directing the sample liquid to an optical spectroscopy device, and a laser beam source. The optical spectroscopy device receives the laser beam from the laser source, and guides the laser beam to the sample liquid to generate an optical spectroscopy signal. A detector detects the optical spectroscopy signal and creates a detection signal responsive to the optical spectroscopy signal. A processor processes the detection signal to determine the identity and amount of at least one chemical species in the liquid. A system for continuously sampling a chemical reaction and a method for continuously monitoring and controlling a chemical reaction are also disclosed.

Morales Rodriguez, Marissa E.↗

Enhancing Lifeline Infrastructure Resilience

Establish operational critical infrastructure research environment with focus on control systems security Continue enhancement of critical infrastructure cyber-physical interdependency analysis and knowledge management capabilities

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗